Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

CREATE A CHINESE ELECTRIC DRIVE

AND CONTROL VERY COST-EFFECTIVE BRAND

Company: Shenzhen M-driver Technology Co., Ltd.


Add: Building D2, Hengli Industrial Park,Longgang District ,Shenzhen
City,Guangdong Province , China.
Telephone: 86-0755-86389291
Website: www.m-driver.com
Shenzhen M-driver Technology Co.,Ltd
COMPANY PROFILE
Shenzhen M-driver Technology Co., Ltd. is located in Shenzhen, which is the capital of national
innovative city. Since its inception, the company has always focused on motor drive and control
technology, adhered to the growth of the company and staff growth as a whole, and adhering
to provide customers with professional customized solutions and import substitution
marketing strategy and the existence of a considerable number of high-tech enterprises.
At present, the company's main products are general vector low-voltage frequency converters,
and in the follow-up development will gradually increase PLC, man-machine interface, servo
and other motor drive and auxiliary programs, to help customers create better equipment
supporting services in the basic needs. Our products are widely used in machine tools, plastics,
printing and packaging, textile, electronic equipment, building materials, metallurgy, coal
mines, municipal and other industries. Its voltage range covers 180 Vac to 480 Vac.
The company now has a single office building, covering an area of more than 5000 square
meters. There are many modern production lines with annual output of more than 100,000
units. Quality, technology and manufacturing capability are the company's outstanding
advantages. More than 16 years of experience in frequency converter design and
manufacturing have enabled the company to have good quality management and
manufacturing capabilities. We always adhere to the quality as the center, committed to
providing customers with stable and efficient products and unremitting efforts.

SMT workshop Component welding Low power assembly PCBA testing Overload testing Super storage warehouse
workshop production line
启动 编程
停止 确认

PRODUCT INTRODUCTION
General frequency inverter Solar water pump inverter Pump controller Inverter cabinet
Constant pressure water supply Permanent magnet synchronous frequency inverter Inverter controller
INDUSTRY APPLICATION

Metallurgical Transfer machine Wind energy Modern manufacturing Water supply Construction Heavy load
industry industry industry industry machinery

Protective functions

MPa

Over Overheat Over Under Over load Phase loss Energy Soft start Speed Constant Precise Stable
current voltage voltage saving and stop control pressure brake running
General vector frequency inverter ( M550 series) Shape and size

W D
W1 D1

H1 H

External size(mm) Mounting size(mm)


NO Item/Power Diameter
H W D H1 W1
A05 30-37KW 348.5 227 171.5 323 208.5 8.5mm

950-45 45-55KW* 344 228 223 324 206 8.5mm

A06 45-55KW 490 327.5 238 459 202.5 10mm

A075S 75-93KW 526 300 304 504 200 9mm

A08 110-132KW 690 370 360 636.5 232 10mm


M-driver mainly focus on products of universal vector frequency inverter from
A160S 160-220KW 720 410 360 690 330 10mm
0.75-630KW.The products are widely used in machine tools, plastics, printing and
packaging, textiles, electronic equipment, building materials, metallurgy, coal,
A280 250-315KW 963 600 380 933 400 12mm

municipal, solar energy and other industries, the voltage widely covers A400 355-500kw 1180 680 390 1145 440 16mm
180vac-480vac. A600 560-630KW 1330 786 410 1295 500 16mm

*We will not give additional notice of the size change due to product upgrade.
Item Specifications
Wiring diagram Over load G type:150% rated current 60s;180% rated current 3s
capability P type:120% rated current 60s;150% rated current 3s
Torque boost Auto torque boost function; Manual torque boost 0.1%~30.0%
V/F curve Linear V/F, multi-point V/F and square V/F curve(power of 1.2,1.4,1.6,1.8,2)
Wiring diagram for single phase Wiring diagram for three phases V/F separation 2 ways: separation and semi-separation
220V frequency inverter 380V frequency inverter Straight line or S curve acceleration and deceleration mode,
Acc./dec curve Four kinds of acceleration and deceleration time. Acceleration and
deceleration time range from 0.0s to 6500.0s

DC braking frequency:0.00Hz to maximum frequency. Braking time:0.0s


DC braking to 36.0s
Brake current value:0%-100%
Basic Jog frequency range: 0.00Hz~50.00Hz;
Jog control
function Jog acceleration/deceleration:
0.0s~6500.0s.
Simple PLC It can realize at maximum of 16 segments speed
Three phases
Single phase Multiple segment
Ground 380V intput Ground Running via the built-in PLC or control terminal.
220V input speed running
Built-in PID It is easy to realize process-controlled closed loop control system.
Auto voltage It can keep constant output voltage automatically in the case of change
regulation (AVR) of network voltage.

Over-voltage/current It can limit the running voltage/current automatically and prevent


stall control frequent over-voltage/current tripping during the running process.
Quick current limit Minimize the over-current fault, protect normal operation of the AC Drive.
"Excavators" characteristics, automatically limit torque during operation,
Torque limit &
prevent frequent over-current tripping. Closed loop vector mode can
Braking resistor Three phases 380V output control
Braking resistor Three phases 380V output realize the torque control.
When instantaneous power off, voltage reduction is compensated
Instantaneous stop
through load feedback energy, which could make AC Drive keep running
non-stop
Personalized in a short period of time.
function
Diagram of control circuit terminal layout
Rapid current limit To avoid AC Drive frequent over-current fault.
Timing control Timing control function:
set time range 0Min~6500.0Min.
Operation panel reference, control terminal reference and serial communication
Command source
port reference. These channels can be switched in various modes.
T/A1 T/B1 DI1 DI2 D13 D14 D15 S+ S- AI1 AM There are totally eleven types of frequency sources, such as digital reference,
Frequency source analog voltage reference , analog current reference, pulse reference, MS speed,
PLC, PID and serial port reference.
TA TB TC A01 COM A02 24V FM GND AI2 10V Running
5 digital input terminals;2 analog input terminals;1 supporting 0-10V voltage
Input terminal
input or 0~20mA current input terminal.

2 digital output terminals;


2 relay output terminals;
2 analog output terminals,
Output terminal
supporting 0~10V voltage output or 0~20mA current output.
900 Series multi-function VFD

Compact size,easy installation,double CPU,much lower failure rate TB TA 24V COM DI1 DI2 D13
380V(R/S/T)
D14 GND AO 15V S+ S-

R S T UVW

380V (U/V/W)

D W W1
Wide Applications

H H1

Blowers Farm Ventilation Kitchen Fans


External size(mm) Mounting size(mm) Diameter
NO Item/Power
H W D H1 W1

900E E1:0.2-1.5KW(220V) 153 86 96.5 144.8 76 4.5mm


E2:0.75-2.2KW(380V)

M1:0.75-1.5KW(220V)
900M 153 86 123 145 76 4.5mm
M2:0.75-2.2KW(380V)

A00 0.75-2.2KW(220V)
170 86 141 157 75 5mm
0.75-2.2KW(380V)
A01 4-5.5KW(380V) 188 96 171 176 83.6 5mm
950-11 7.5-11KW 228 114 192 214.5 98.7 5mm
950-15 15-18.5KW 290 160 182 269 143 6.5mm Domestic Water Supply Assembly Line Logistics Sorting
950-22 22KW 328 193 217 305 172 8.5mm
Solar water pump inverter (PV500 series)
Built in MPPT / Built in Protection Function
DC circuit breaker
DC AC Switch / Run Without Battery
Automatic Start Function / Easy Operation
Barren hills
Product specifications governance

Model G1 G2 G3
(high water level),(low water level) Ecological
governance
220(-15%)~240 220(-15%)~240 380(-15%)~440
AC Input Voltage (V)
(+10%)(1PH) (+10%)(3PH) (+10%)(3PH)

U V W
Max.DC Voltage (V) 400 400 800
+ - Farmland
irrigation
Start-up Voltage (V) 200 200 300 Float switch

Lowest Working 150 150 300-750 Soil erosion


Voltage (V) protection
Recommended DC
Input Voltage Range(V) 200-400 200-400 300-750

Recommended MPPT
Voltage(V) 330 330 550 Domestic water
Constant pressure water supply system (510 series) terminals
TA1 TB1 DI1 DI2 D13 D14 D15 S+ S- AI1 AM

TA TB TC A01 COM A02 24V FM GND AI2 10V

Single phase pressure transmitter


220V input
TA1 TB1 DI1 DI2 D13 D14 D15 S+ S- AI1 AM
N L
TA TB TC A01 COM A02 24V FM GND AI2 10V

R T UV W

connection diagram for


single phase 220V VFD Remote pressure gauge

Multi-inverter constant pressure water supply system

Pressure display
Loop pipe network

Municipal pipe network


Clean water tank
Conventional
Feedback pump
Signal

Production pipe network


Dormant pump

Multiple Pressure tank Pressure sensor Remote pressure Ball valve


centrifugal pump gauge
Inverter cabinet (800 series) Wiring diagram
380V 800H series inverter cabinet

PUMP USE MOTOR USE

380V ac grid

adapted motor rated output


pump use motor use power
KW HP current(A)
800-0007H1 800-0007G1 0.75 1 4
800-0015H1 800-0015G1
220V
single phase 1.5 2 7

pressure transmitter 380V ac pump


800-0022H1 800-0022G1 input 2.2 3 10
800-0007H3 800-0007G3
800-0015H3 800-0015G3
0.75 1 2.5
(1 pcs of pressure transmitter is well
connected before shipping)
1.5 2 3.7
800-0022H3 800-0022G3
2.2 3 5.1
800-0040H3 800-0040G3 DC AI GND DI
4 5 8.5
800-0055H3 800-0055G3
5.5 7.5 13 Green Yellow Red
800-0075H3 800-0075G3
7.5 10 16
800-0110H3 800-0110G3
380V
three phase 11 15 25
800-0150H3 800-0150G3 input
15 20 32
800-0185H3 800-0185G3 pressure gauge (optional)
18.5 25 38
800-0220H3 800-0220G3
22 30 45
800-0300H3 800-0300G3
30 40 60
800-0370H3 800-0370G3
37 50 75 240mm 159mm 210mm (安装孔)
7mm

NO. 0.75-4KW 5.5-7.5KW

W 240 296

275.5mm (安装孔)
Dimension

300mm
D 159 171
(mm)
H 300 380

installation W1 210 353.5


size(mm) H1 275.5 266

holeΦ(mm) 7 7
Smart pump controller

7MM

3MM
266.4MM

234MM
274MM
315.3MM

Y1-R1 380V Y1-R2 380V


250MM

ON

1 2
     
  
170MM
Power supply

Y2S1-R1 220V Y2S3-R1 380V


U1 V1 W1

ON
High level 1 sensor
1 2
Middle level sensor
Water source Low level sensor
     
  
Reservoir

When the water level reaches the high level (terminals 3, 4, 5, and 6 are connected), the single pump stops.
830 Series Permanent Magnet Synchronous Drive

Single-phase power input ouput Three-phase power input ouput

R U R U
启动
停止
编程
确认
启动
停止
编程
确认
启动
停止
编程
确认
S V M S V M
W T W
Grounding
Grounding
protection
protection

220V Wiring diagram 380V Wiring diagram

Quick Commissioning Guide:


Asynchronous motor: 1. Set F3-00 =0 Asynchronous motor 2. Set F3-05 =0 3. Start
Synchronous motor:
1、The customer can provide the motor back EMF according to the following parameter settings.

Parameters Description Parameters Description


F0-00 Motor rated power F0-03 Motor rated frequency
F0-01 Motor rated voltage F0-04 Motor rated speed
F0-02 Motor rated current F0-05 Back EMF coefficient

Start up in keyboard Increase the data or


START operation mode the function code.
STOP Stop in keyboard operation mode.

Menu entry or exit


Enter the menu to confirm the Decrease the data or
PRGM parameter settings.
ENT the function code.
Long press for 3 seconds to enter
the parameter setting.