SCHEDULE 2.

0 OUTLINE SPECIFICATIONS

S.N. Section Description

Building Specifications
1 Building Clear Height 12 m at eaves side of the building
2 Roofing Material “Standing Seam”
3 Skylight Panels Polycarbonate panels approximately 5% of roof area
4 Roof Monitor / Ridge Ventilator Roof monitor for passive ventilation
5 Louvered Panels Both long side of the building
6 Canopy Depth 4.50m from dock wall
7 Building Floor / Loading Dock Height 1.2m (above truck court elevation at the dock wall)
8 Slab Load Building area - 5T/m2 UDL. Only pit provided for dock leveler.
9 Perimeter Hard Wall Height 3.6m (above slab elevation).
10 Perimeter Hard Wall Material Concrete wall (precast waffle wall)
11 Dock Doors Numbers As shown in the layout, manually operated MS rolling shutter
12 Dock Door Width x Height 2.4 m x 3.0 m
13 Drive-In Doors As shown in the layout, manually operated MS rolling shutter
14 Drive-In Ramp As shown in the layout, manually operated MS rolling shutter
15 External Fire Hydrant Line Available
16 Hose Real & Fire Extinguisher Available as per local code
17 Fire Escape Doors Available as per local code
18 Earthing For PEB structure only
19 Truck Apron Area Finish Type Concrete/bitumen
Total population considered 272 persons per day including all shifts (136 x 2
20 Total Population shifts considered)
Male : Female ratio 80 : 20
No cover/ roof shall be allowed for any utility equipment.
21 Utility Space
D.G. Set
22 Parking No cover/ roof shall be allowed for parking. Parking area as shown in layout.

Page 1 of 2
B Building Tenant Improvements
1 Power upto building - 342 KVA Maximum Demand Load
2 Building internal firefighting system which includes K115 type roof sprinkler, fire alarm & fire detection system
3 Building internal electrification & lighting fixture (LED type) to provide average 150 Lux Level in shop floor area
4 Toilet on shop floor - 813 Sq.Ft.

C Lessee scope/ Lessor exclusions


Office internal improvement above and below mezzanine, which includes gypsum partition, screed, flooring, false ceiling,
1 firefighting system, HVAC, electrical distribution & lighting fixture, pantry & toilet for staff, staircase finishes and
enclosures etc.
2 D.G. set & its associated panel, DG Platform, DG cabling earthing & DG commissioning.
Power distribution to lessee’s equipment, which shall include but not limited to electrical panels, cables, earthing’s, utility
3
services, machinery & related equipment.
4 Mechanical Ventilation and air conditioning
5 Racking system & In-Rack sprinklers
6 Floor Drains/trenches/pits
7 Foundation for any kind of lessee utility equipment/machinery
8 Security Deposit towards EB and power connection in case the power is given in the name of Lessee
9 Temporary power and water supply during fit-out works
10 IT infrastructure like data cables, RF towers. routers etc.
11 Floor Drains
12 Any other improvement work which are not outlined in lessor’s scope of work
13 Dock Levelers