Download as pdf
Download as pdf
You are on page 1of 1
‘Sub: Quality Audit of USFD testing of Rail Ref: Railway Board's letters no. Track/ 21/2007/0113/7/5/PCE Conf. dt: 14.10.2014. A) General:- Date of Audit: 06/05/2023 Section: PNT/NTSK Division: TSK ki: 44/6-7 Line: Single Machine used for testing: AT Weld Tester & Single Rail Tester (B-Scan) Machine make: MODSONIC ‘Model: EINSTEIN-It (AT) & RAILSCAN 110 SN No. £5332-9110 & AS0165-2280 ‘Track Structure on test location: PSC, M48, 52 Kg, Weather stretch is having D-mark Rails: YES B) _())Operator Details: SN | Operator Name & Designation _ | Competency certificate details Validity of Certificate | Remarks REGULAR __[_LAST REFRESHER 1_| SANJIB KR. PATAR, SSE/USFD FEB’ 2008 MAY’ 2022 Upto May’2027 Updated 2_ | AMARJYOTI MOHAN, SSE/USFD_| —AUG'2007 FEB’2020 Upto Feb’2025 Updated 3__[ RANJIT KR. BHUYAN, SSE/USFD_ | AUG'2012 FEB'2020 Upto Feb’2025 Updated 4__| KALYAN KR. GOGOI, ‘SSE/USFD. FEB’2008 MAR’2021 Upto June’2023 Updated (ii)Subordinate Staff: ‘Adequate staff for handling /lifting | 15 nos. of Subordinate staffs are available which is sufficient for of machine handling/lifting of machines. C)_USED Machines & Canditions: SN] Machine Make ‘Model Serial No. Service Life | WhetherRDSO | Remarks Approved or not 1_[ MODSONIC EINSTEIN IAT) | E5331-9110 | 4Years3 months | RDSO Approved | No overage 2 =| MODSONIC EINSTEIN (AT) | £5332-9110 _ | _4Years3 months | RDSO Approved | No overage 3__| MODSONIC EINSTEIN IAT) [ €5333-9110 | 4Years3 months | RDSO Approved | No overage 4 | MODSONIC RAILSCAN 130 | ASO163-2280 8 months RDSO Approved No overage 5__| MODSONIC RAILSCAN 110 | ASO164-2280 8 months RDSO Approved No overage 6_| MODSONIC RAILSCAN 110 | ASO165-2280 'S months RDSO Approved | No overage 7_|mopsonic RAILSCAN 110 | AS0266-2280 ‘& months RDSO Approved | No overage D) Availability of Requisite Tools & plant: sn items Observations Remarks 1-_‘| Sensitivity block 7 nos, ‘Sufficient blocks are available but not calibrated by certified Agency 2 [IW block for calibration nos. Not calibrated by certified Agency 3 | Standard Rail test piece 3 nos. Zat NTSK & 1 at MXN 4 [Visual Condition of electronic unit Satisfactory = 5_| Visual condition of Trolley Satisfactory = 6 _| Condition of Probes & shoes Satisfactory — i) _| Single Rail Tester (SRT) (@) | 0 degree ‘Available = (by | 70 degres(r) Available Gauge Face, Non Gauge Face & Central probes are available (¢) | 70 degree (8) ‘Available ‘Gauge Face, Non Gauge Face & Central probes are available Page 1 of 6

You might also like