POWER LIGHTING GENERAL NOTES

1. ALL ELECTRICAL WORKS AND INSTALLATIONS HEREIN SHALL BE DONE


SYMBOL DESCRIPTION SYMBOL DESCRIPTION IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST EDITION OF HTE
ELECTRICAL CODE WITH THE RULES AND REGULATIONS OF THE NATIONAL
POWER PANELBOARD 13 WATTS, LED BULB AND THE LOCAL AUTHORITIES CONCERNED IN THE ENFORCEMENT OF
ELECTRICAL LAWS AND ORDINANCES AND WITH THE RULES AND
ACU AIR CONDITIONING OUTLET S1 1 GANG SWITCH REGULATIONS OF THE UTILITY COMPANIES CONCERNED.
2. POWER SERVICE TO THE BUILDING SHALL BE 230V, 3 PHASE, 3 WIRE,
WM WASHING MACHINE OUTLET S2 2 GANG SWITCH 60 HZ SYSTEM.
3. WIRING METHOD SHALL BE AS SPECIFIED IN THE SPECIFICATIONS.
REF REFRIGERATOR OUTLET S3 3 GANG SWITCH 4. UNLESS OTHERWISE SPECIFIED IN THE PLA, MINIMUM SIZE OF WIRES
AND CONDUIT SHALL BE NO. 1.6MM DIA.TYPE TW AND 15MM DIA.
RESPECTIVELY, WIRES SHALL BE INSULATED FOR RATING SUITED FOR THE
DUPLEX CONVENIENCE OUTLET EQUIPMENT SERVED.
5. GENERAL USED RECEPTACLE SHALL BE RATED 10.0 AMP., 250V WITH
WP WEATHER PROOF CONVENIENCE OUTLET PARALLEL SLOTS, SPECIAL PURPOSED OUTLSCET SHALL BE OF THE TYPE
N AND RATING SUITED FOR THE EQUIPMENT SERVED.
CIRCUIT HOMERUN 6. TYPES OF CONDUIT SHALL BE DONE AS FOLLOWS: A. RIGID STEEL
CONDUIT (RSC) _ _ _ _ _ FOR FEEDER AND SUB-FEEDER RACEWAY. B.
M KWHR METER POYVINYL CHLORIDE (PVC) PIPE _ _ _ _ _ _ _ _ FOR ALL LIGHTINGS AND
POWER BRANCH CIRCUIT RACEWAYS RUNNING IN CONCRETE SLAB AND
SERVICE ENTRANCE WALLS AND ALL OTHER AUXILIARY SYSTEM RACEWAY. C. ELECTRICAL
TUBING (EMT) _ _ _ _ _ _ _ FOR ALL LIGHTINGS AND POWER BRANCH
ALFAMART
CIRCUIT RACEWAYS RUNNING INSIDE CEILINGS AND WOODED WALL
PARTITIONS.
P BURGOS ST. 7. ALL CONDUITS INDICATED HEREIN SHALL BE OF INSIDE DIAMETER.
8. ALL ACCESSORIES, SPLICING DEVICES, TERMINATIONS AND OTHER
APPURTENANCES FOR THE ENTIRE INSTALLATIONS SHALL BE OF THE
SITE APPROVED TYPE AND U.L. LISTED.
9. ALL PANEL BOARDS SHALL BE EQUIPPED WITH GROUNDING KIT
TERMINALS WITH THE NUMBERS OF TERMINALS EQUAL TO NUMBER OF
J CASTRO ST. BRANCH CIRCUITS.
10. ALL ELECTRICAL EQUIPMENTS SHALL BE PROPERLY GROUNDED IN
ACCORDANCE WITH THE REQUIREMENTS OF THE ELECTRICAL CODE.
BUENAFLOR ST.

11. ALL MATERIALS TO BE USED SHALL BE NEW AND OF THE APPROVED


TYPE FOR BOTH LOCATIONS AND PURPOSED INTENDED.
12. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT
SUPERVISION OF A DULY REGISTERED ELECTRICA ENGINEER
N NER ST.

ALFAMART

RIZAL ST.

PROJECT TITLE : OWNED BY: SHEET CONTENT: DESIGNED AND DRAWN BY: CHECKED BY: NAME OF PEE: PRC REG No.
DENISSE DEAN E. OCAMPO
GENERAL NOTE DENISSE DEAN E. OCAMPO ENGR. LYNDON BAGUE
ISSUED AT: E
PROPOSED TWO STORY
ADDRESS: VICINITY MAP PTR No.:
SINGLE FAMILY DWELLING LEGENDS
1 9
CALLEJON 4, SAPA 2,
HOUSE ROSARIO CAVITE TIN No.: