Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Bidder's Response

S.No. Parameters Sub- Parameters DCBL requirements


MMS Table Configuration
1 Bidder Design Mono Rail
(No. of modules per Table)
2 Tilt Fixed Fixed
4 Ground Clearance (Minimum) 500 mm NA
5 Wind Speed (m/s) considered for design 44 36.7
min 2.5 mm with HDG 80
6 Column Post Thickness Min thickness NA
Micron
7 Column Post Length m NA
8 Weight of Column post per Mtr Kg/mtr NA
Min thickness 1.2/1.6 mm NA
9 Bracing and Rafter
Galvalume Galvalume, AZ150 NA
Design Thickness 1.0/1.2 mm NA
10 Purlins
Yield strength Galvalume, AZ150 NA
11 Fasteners for Module Mounting SS 304 As per design
Fasteners for other MMS connections except
12 SS 304 As per design
module mounting
Pile diameter 300mm NA
Pile depth 1800mm NA
13 MMS Pile Foundation
Pile cap height 200 mm NA
Grade of concrete M25 NA
Piles per Table NA
Piles per MW NA
Total piles NA
Pile to pile distance <=3 m NA
Concrete M3 0.1415 cum per pile NA
Per MWp M3 shall to be
considered 70 M3/MWp( based
14 Number of Piles constructed
on Preliminary Pile Design
Assumption, Actual Concrete
Total Concrete NA
will be certified as per Final
Approved Design. ( Add/ Del
Applicable only for MMS Pile
Casting Only)
Incremental cost Rs/M3 NA
15 Codes and Standards As per design
16 Utilization Ratio of MMS design <=0.8 As per design
17 Resulting Weight per MW(DC) MT/ MWp Bidder to Confirm As per design
18 Fencing Length Rmtr Bidder to Confirm NA
19 Peripheral Road Rmtr Bidder to Confirm NA
20 Internal road Rmtr Bidder to Confirm NA
21 Drainage Rmtr Bidder to Confirm NA
22 HT Cable length Rmtr Bidder to Confirm NA
23 Incremental cost per Tonne of MMS Rs/MT Bidder to Confirm As per design
24 Cost per rmtr of peripheral road Rs/Rmtr Bidder to Confirm NA
25 Cost per rmtr of internal road Rs/Rmtr Bidder to Confirm NA
26 Cost per rmtr of drainage Rs/Rmtr Bidder to Confirm NA
27 Cost per rmtr of HT cable Rs/Rmtr Bidder to Confirm NA
28 Cost per rmtr Fencing Rs/Rmtr Bidder to Confirm NA