MODEL

ERU280HSP

ENGINEERING CODE COOLING CAPACITY

513305574 97 W (LBP)

APPROVED REFRIGERANT EFFICIENCY

R-134a 1.2 W/W (LBP)

POWER SUPPLY MOTOR TYPE

220 V 50 Hz RSCR

STANDARD CONDITIONS STARTING TORQUE


EN12900 LST
APPROVALS
APPLICATION

LBP

DATA

General Data
Type Hermetic reciprocating

Technology Type On-Off

Displacement 6.36 cm³

Compressor Cooling Static/NotControled/220

Expansion Device Capillary Tube

Horse Power 1/4 hp

Power Supply 220 V 50 Hz

Evaporating Temperature Range -35 °C to -10 °C

Electrical Data
Motor type RSCR

Starting Torque LST

Start Winding Resistance 12.13 at 25° C

Run Winding Resistance 19.45 at 25° C

Rated Load Amperage (RLA) at 50 Hz 1.35 A


Mechanical Data
Oil Charge 150 ml

Oil Type Configuration ESTER

Oil Type Viscosity ISO10

Weight 7.53 Kg

Electrical Components
Description

Run Capacitor 5

Motor Protection 4TM232KFBYY-53

PTC | 8EA17C3 8EA17E61 8EA17E62 8EA17E63


Starting Device
8M220MD3 QPS2-A22MD3 QPS2-A22MD3 091

External Characteristics
Tray Holder No

Connector Internal Diameter Shape

Suction 6.5 mm Slanted 42? up + 45? to Back/Copper

Discharge 4.94 mm Slanted parallet BP+24?to Back/Copper

Process 6.5 mm Slanted parallel BP+45?to Back/Copper

PERFORMANCE

Rated Points
Condensing Evaporating Cooling Power Gas Flow
Efficiency
Temperature Temperature Capacity Consumption Rate

40.00°C -35.00°C 97 W 80 W 2.11 kg/h 1.2 W/W

Test Condition: EN12900LBP, Static/NotControled/220, Return Gas 20°C, Evaporation -35.00°C, Condensing 40.00°C, Ambient 35°C , Liquid 40°C, Subcooling 0K. Data are an indication of

performance based simulation.


Performance Curve Data

Condensing Temperature 35°C

Evaporating Cooling Gas Flow Efficiency


Power W
Temperature °C Capacity W Rate kg/h W/W

-35 108 79 2.27 1.36

-30 150 92 3.15 1.62

-25 201 106 4.24 1.9

-20 263 120 5.56 2.19

-15 338 135 7.14 2.51

-10 424 148 9.01 2.87

Test Condition: EN12900LBP, Static/NotControled/220, Return Gas 20°C, Ambient 35°C , Subcooling 0K. Data are an indication of performance based simulation.

Condensing Temperature 45°C

Evaporating Cooling Gas Flow Efficiency


Power W
Temperature °C Capacity W Rate kg/h W/W

-35 85 81 1.96 1.06

-30 122 95 2.80 1.29

-25 167 110 3.86 1.52

-20 223 127 5.15 1.75

-15 289 145 6.71 1.99

-10 367 164 8.56 2.24

Test Condition: EN12900LBP, Static/NotControled/220, Return Gas 20°C, Ambient 35°C , Subcooling 0K. Data are an indication of performance based simulation.

Condensing Temperature 55°C

Evaporating Cooling Gas Flow Efficiency


Power W
Temperature °C Capacity W Rate kg/h W/W

-35 64 82 1.64 0.78

-30 95 96 2.43 1

-25 135 112 3.43 1.2

-20 183 131 4.68 1.39

-15 241 153 6.21 1.58

-10 310 175 8.03 1.77

Test Condition: EN12900LBP, Static/NotControled/220, Return Gas 20°C, Ambient 35°C , Subcooling 0K. Data are an indication of performance based simulation.
Operating Envelope

External Dimensions