PROJECT DESCRIPTION
Detailed Version
23-NOV-2020
KAM - H.W. Dietz
All information in this document is confidential and should not be made accessible
to third parties without permission!
German company based in Lahnau, 60 km north of Products developed and produced in Germany
Frankfurt/Main, about 200 employees approx. 125,000 measurement devices annually
Scope: Development, production and distribution of Janitza measurement devices are used in more
solutions for energy management and for monitoring than 60 countries worldwide
power quality
Building Automation
ZDF, Frankfurt Trade Fairs, European Central Bank, University hospital Basel, …
Utilities
Netze BW, RWE, Sedas, Endesa, Amprion, SMA, Enercon, …
Data Center
KPN, T-Systems, Ericsson, DFS, Telecity Group, Ministry of Finance NL, …
Transport Infrastructure
Netze BW, RWE, Sedas, Endesa, Amprion, SMA, Enercon, …
A wide range of meters and analyzers enables the design of customized measuring systems across all levels.
Supply reliability
GridVis Energy:
Web-based visualization for
GridVis Desktop: convenient display and
GridVis Service:
Engineering tool for setting up evaluation of measured values.
Background program for the
cyclical reading of measured the system, for commissioning
values and storage in an MS SQL and parameterizing meters and
database. for creating reports.
Ethernet network
UMG meters with Ethernet interface will UMG meter with Ethernet interface
be connected directly to the network.
Modbus (RS485)
Modbus (RS485)
UMG meters with Modbus interface E+H Flowmeters with Modbus interface
will be connected via a Janitza meter will be connected via a Janitza meter
with gateway functionality. with gateway functionality.
Infeed Level
Optional Solution: (needs permission by local power utility!)
Metering on medium voltage level (e.g. 11 kV)
1x UMG 512 (attention: voltage transformes needed for medium voltage!)
Distribution Level
1x Power Analyzer UMG 96RM-E
Feeder Level
… … Feeders or
individual consumers
1x Power Meter UMG 96RM-CBM (or UMG103-CBM, UMG96PA-MID, B21 or B23) per feeder (optional)
Live-Demo: https://www.janitza.us/gridvis-energy-demo.html
Smart Energy & Power Quality Solutions
© by Janitza electronics GmbH, 2018 Seite: 15
Plant Entrance Metering Standard | Project Description
Software GridVis Ultimate | Functional Overview I
The customer-specific edition “GridVis Ultimate SE” created for this project consists of the following
components:
GridVis Desktop:
Engineering tool for setting up the system, for commissioning and parameterizing meters and for
creating reports. The SE-license allows a maximum of 2 installations of the GridVis Desktop-Software.
Can be extended with GridVis Professional licence(s), if more than 2 Desktop installations required.
GridVis Service:
Background program for the cyclical reading of measured values and storage in an MS SQL database.
(Note: The database is not included with the software.) The SE-license allows one installation of the
GridVis Service-Software.
GridVis Energy:
Web-based visualization for convenient display and evaluation of measured values.
OPC UA:
Higher-level systems can be connected via an optionally available OPC UA server.
The OPC UA Server is not part of this edition and must be purchased additionally.
MS SQL:
A MS SQL database is needed to store the measured values. This Database is not included in the
delivery of Janitza and must be installed and set up by ZF.
Smart Energy & Power Quality Solutions
© by Janitza electronics GmbH, 2018 Seite: 23
Plant Entrance Metering Standard | Project Description
Software GridVis Ultimate | Standard-Dashboards for ZF
Several standard dashboards for this project
were prepared by Janitza. They should be used
as standard overview pages for each location.
Currently, these dashboards are available in the
following languages:
English
German
French
Spanish
Portuguese
Chinese (in preparation)
Additional dashboards can be easily created
with the integrated graphical editor by the ZF
team. Alternatively they can be created by
Janitza as a paid service.
The GridVis Service Software alternatively can be installed and serviced by the central IT department on virtualized servers
located in a ZF Data Center. In this case the system requirements described on the next page must be strictly observed!
• GridVis Desktop:
The GridVis desktop software will be needed for configuration of the system and can be installed locally or in the Datacenter
depending on the necessary access rights. One GridVis Ultimate SE licence includes two Desktop installations, if more than two
licences are needed they can be bought separately.
Memory (MB)
calculation tool is available from Janitza. 1500
1000
To minimize space requirements,
GridVis database compression 500
capabilities can be used. 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
Number of devices
UMG 96RM-CBM Monitoring single consumers or feeders Front door Modbus Slave
52.22.066 PQ capacity: low 3-line display No Gateway
Communication Interfaces
Ethernet (RJ45)
Modbus RTU (RS485)
Integrated Modbus-Ethernet gateway functionality
Measuring Accuracy
Energy: Class 0.2S (... / 5 A)
Current: 0.2 %, Voltage: 0.1 %
Certified accuracy according IEC 61000-4-30 Class A
Power Networks
IT, TN, TT networks, 3 and 4-phase
Power quality Monitoring
Harmonics up to the 63rd harmonic, odd / even
Flicker measurement, Short term interruptions (from 10 ms)
Transient recorder (> 39 μs), Start-up currents (> 10 ms)
Imbalance, Half wave RMS recordings (up to 11 min.)
Class A-Power Quality Analyser
Typ: UMG 512-PRO Memory
256 MByte Flash
Art.-Nr.: 52.17.011
Downloads: https://www.janitza.com/umg-512-pro-downloads.html I/O
2 digital inputs, 2 digital outputs
1 Thermistor input (PT100, PT1000, KTY83, KTY84)
2 RCM (residual current monitoring) inputs
Smart Energy & Power Quality Solutions
© by Janitza electronics GmbH, 2018 Seite: 31
Plant Entrance Metering Standard | Project Description
UMG 512-PRO | Connection Plan
Communication Interfaces
Ethernet (RJ45)
Modbus RTU (RS485)
Integrated Modbus-Ethernet gateway functionality
Measuring Accuracy
Energy: Class 0.5S (... / 5 A)
Current: 0.5 %, Voltage: 0.2 %
Power Networks
IT, TN, TT networks, 3 and 4-phase
Basic Power Quality Monitoring
Harmonics up to 40th harmonic
Rotary field components
Distortion factorTHD-U /THD-I
Memory
Multifunctional Power Analyser 256 MByte Flash
Typ: UMG 96RM-E I/O
Art.-Nr.: 52.22.062 2 digital inputs, 3 digital in/outputs
Downloads: https://www.janitza.com/umg-96rm-e-downloads.html 2 analogoe inputs, for temperature or RCM (residual current monitoring)
Communication Interfaces
Modbus RTU (RS 485)
Measuring Accuracy
Energy: Class 0.5 (... / 5 A)
Current: 0.5 %, Voltage: 0.2 %
Power Networks
IT, TN, TT networks, 3 and 4-phase
Basic Power Quality Monitoring
Harmonics up to 40th harmonic
Rotary field components
Distortion factor THD-U /THD-I
Memory
256 MByte Flash
I/O
Multifunctional Power Analyser 4 digital inputs, 6 digital outputs
Typ: UMG 96RM-CBM
Art.-Nr.: 52.22.066
Downloads: https://www.janitza.com/umg-96rm-cbm-downloads.html
Communication Interfaces
Modbus RTU (RS 485)
Measuring Accuracy
Energy: Class 0.5 (... / 5 A)
Current: 0.5 %, Voltage: 0.2 %
Power Networks
TN, TT networks, 3-phase
Basic Power Quality Monitoring
Harmonics up to 25th harmonic
Rotary field components
Distortion factor THD-U /THD-I
Memory
4 MByte Flash
Energy Meter
Typ: UMG 103-CBM
Art.-Nr.: 52.18.001
Downloads: https://www.janitza.com/umg-103-cbm-downloads.html
Main Features
Ideal for retrofitting as the primary current circuit need not be disconnected
Ideally suited for energy and power quality measurement devices
Ideal for use in very compact installation spaces
Especially fast installation
Including colour-coded secondary lines
Fastening of the transformer with the two UV-resistant cable ties provided
Transformation ratio: 60/1 A to 1000/5 A
Rated power: 0.2 to 0.5 VA
Precision class: 0.5, 1 and 3
Round conductor: Ø 18 / 28 / 42 or 42 x 84 mm
Dimensions: 48 x 50.4 to 66.2 x 139 mm
Current transformer per IEC 61869-2
All dimensions in mm
Smart Energy & Power Quality Solutions
© by Janitza electronics GmbH, 2018 Seite: 43
Plant Entrance Metering Standard | Project Description
Split Core Current Transformers for Retrofitting | Details KUW 1/40
All dimensions in mm
Smart Energy & Power Quality Solutions
© by Janitza electronics GmbH, 2018 Seite: 44
Plant Entrance Metering Standard | Project Description
Split Core Current Transformers for Retrofitting | Details KUW 2/40
All dimensions in mm
Smart Energy & Power Quality Solutions
© by Janitza electronics GmbH, 2018 Seite: 45
Plant Entrance Metering Standard | Project Description
Split Core Current Transformers for Retrofitting | Details KUW 4/60
All dimensions in mm
Smart Energy & Power Quality Solutions
© by Janitza electronics GmbH, 2018 Seite: 46
Plant Entrance Metering Standard | Project Description
Split Core Current Transformers for Retrofitting | Details KUW 4.2/60
All dimensions in mm
Smart Energy & Power Quality Solutions
© by Janitza electronics GmbH, 2018 Seite: 47
Plant Entrance Metering Standard | Project Description
Rogowski coil – thinner, lighter flexible converter for simple installation | Technical Data
The Rogowski coil is used for current measurement of AC currents and is primarily employed for retrospective
installation in existing systems - optionally on power rails or power cables.
Accuracy per class 0.5, in accordance with IEC 61869
Operating temperature –40°C bis +80°C
Rated insulation voltage 1 kV CAT III
Rogowski coil from 10 to up to 4000 ARMS
Retrospective clip-on system without disconnecting the phase conductor
Device for fixing to the primary conductor with a cable tie
High linearity, no saturation, no current upper limit of the Rogowski coil
Separate Janitza Rogowski Transducer needed,
provides a standardised output signal 0…1 A for the UMG meters
Communication Interfaces
Modbus RTU (RS485)
Measuring Accuracy
Effective energy: B (class 1)
Reactive energy: class 2
Others
- Type B21 and B23: Direct connection up to 65 A
- Typ B24: Connection with CT…/1A or …/5A
- With measured values and alarm function
- Width: 2 DIN modules
- Tested and approved according to MID and IEC
- Pulse output included
Communication Interfaces
Modbus RTU (RS484)
Ethernet (RJ45) with optional module 52.32.010
Measuring Accuracy
Voltage and Current: 0,2%
Effective Energy (kWh, .../5 A) class 0,5S
Basic Power Quality Monitoring
Harmonics up to 25th harmonic
Distortion factors THD-U and THD-I
Memory
4 MByte Flash
Others
- Colour Graphics Display
- Tested and approved according to MID
MID-compliant Power Analyzer
Typ: UMG 96-PA-MID UMG 96-PA-MID+
A special version with the functionality "Secure load profile" is
Art.-Nr.: 52.32.003
planned to be available 01/2010.
Downloads: https://www.janitza.com/umg-96-pa-downloads.html
Type:
Thermal Mass Flowmeter for industrial gases and compressed air
Endress+Hauser Proline t-mass 65F and 65I
Measuring principle:
Thermal dispersion principle, operates by monitoring the cooling
effect of a gas stream as it passes over a heated transducer.
Application
For measuring the mass flowrate of a wide range of gas types e.g.
• Compressed air
• Natural gas flow to boilers/dryers
• Carbon Dioxide flow in breweries
• Biogas and aeration air in waste water plants
• Gas production (e. g. Ar, N2, CO2, He, O2)
• Leakage detection
Data sheet:
https://portal.endress.com/wa001/dla/5000009/2467/000/02/TI069DEN_0610.pdf
Type:
Electromagnetic flowmeter for water
Modbus RTU (RS485, max. 31 Slaves) Endress+Hauser Promag P 100 und Promag P 300
Variants:
Proline Promag P300: variant with on-site operating unit
Proline Promag P100: variant without on-site operating unit
Modbus RTU (RS485, max. 31 Slaves) The required variant is selected via the E + H data entry form
Interface:
Modbus-RTU-Interface (RS485). These devices can be integrated
using one of the following Janitza meters as Modbus-Ethernet-
Gateway:
- Janitza UMGs 512, 604, 96RM-E, Datalogger ProData
Alternatively, the integration can take place via one of the
following E + H evaluation units:
- RSG 45 oder RH 33
Software:
A Modbus template for integration into the GridVis software is
in preparation
Type:
Electromagnetic flowmeter for water
Endress+Hauser Promag P 100 und Promag P 300
Measuring principle:
Following Faraday's law of magnetic induction, a voltage is
induced in a conductor moving through a magnetic field.
In the electromagnetic measuring principle, the flowing medium
is the moving conductor. The voltage induced (Ue) is
proportional to the flow velocity (v) and is supplied to the
amplifier by means of two measuring electrodes. The flow
volume (Q) is calculated via the pipe cross-section (A). The DC
magnetic field is created through a switched direct current of
alternating polarity.
Ethernet TCP/IP
Type:
Verifiable BTU meter for recording and billing heat and cold
quantities of water, water/glycol mixtures or other fluids
Endress+Hauser EngyCal RH33
The EngyCal RH33 is used together with a flowmeter Promag P100 or
P300 and 2 temperature sensors TST90, the connection is made via a
4...20mA interface.
Variants:
The required variant is selected via the E + H data entry form
Interface:
Modbus-TCP-Interface (Ethernet). These devices can be integrated
directely in the ethernet network.
Software:
A Modbus template for integration into the GridVis software is
available.
Type:
Verifiable BTU meter for recording and billing heat and cold quantities
of water, water/glycol mixtures or other fluids
Endress+Hauser EngyCal RH33
Measuring system:
The EngyCal RH33 BTU meter is used to measure heat and cold in
systems with liquid heat carriers. It is easy to install and read. Thanks to
its proven longterm stability and high-precision measurements, the
device helps to optimize processes and control costs within the process.
Energy calculation :
The EngyCal RH33 calculates the thermal energy of water, glycol/water
mixtures or other liquids such as thermal oils, in accordance with
EN1434. Basis for calculation: IAWPS-IF97
Calculated values:
• Power
• Volume
• Density
Data sheet: • Enthalpy and enthalpy differential
https://portal.endress.com/wa001/dla/5000557/8084/000/04/TI00151KEN_0318.pdf • DP flow compensation
• Mass
• Temperature differential
Smart Energy & Power Quality Solutions
© by Janitza electronics GmbH, 2018 Seite: 63
Plant Entrance Metering Standard | Project Description
Schneider Electric circuit breaker NSX 160F not specified NSX160F.xml circuit breaker
Schneider Electric circuit breaker NS 1000N not specified NS1000N.xml circuit breaker
For Schneider electric not included in this list Janitza can generate Modbus templates on request:
Janitza can develop templates for specific devices on request as a paid service. This requires the running of a compatibility
test in our laboratory in Lahnau/Germany. Please ask for an individual offer.
Mounting:
The front of the UMG 96RM-E measures 96 x 96mm and requires a cut-out size of 92+0,8 x 92+0,8 mm.
This is the most common standard size for energy meters and the UMG can usually be snaped in
directly into the existing cutout.
Power suppy:
The UMG96RM-E needs a fused power supply of 90…277 V AC 10%. Normally the existing
power supply connetiction can be used, if necessary the fuse has to be adjusted (6 - 16A).
Communication interface:
The UMG96RM-E has an ethernet interface and can be directelyc onnected to ethernet, no
external gateway is needed.
Alternatively, the RS485 interface of the UMG 96RM-E can be used integrate it via Modbus
RS485 ETH
RTU.
Note: The RS485 interface is the easiest way to connect up to 31 devices in the same
cabinet over a twisted pair cable. This reduces the cabeling costs and saves IP addresses.
Communication Interfaces
Modbus RTU (RS 485) and Ethernet (RJ45)
Modbus-Ethernet gateway functionality
Memory
32 MByte Flash
I/O
15 digital / pulse inputs, 1Temperature measurement input
3 digital outputs, switchable via Modbus, weekly timer, threshold
value and temperature monitoring
Connection plan:
Data Logger
Typ: ProData®
Art.-Nr.: 52.24.011
Downloads: https://www.janitza.com/prodata-downloads.html
8. Project Handling
The process of project execution described below has been bindingly agreed between these companies:
Janitza takes over the entire project handling, including the delivery of the required E+H-components to ZF,
on agreed, globally valid terms.
E+H is available in the background for clarification of technical questions or, if necessary, technical support.
Service and support for the E+H components can be obtained from Janitza or directly from ZF at E+H. The
local terms of service and prices of E+H apply here.
1. Janitza (or the responsible Janitza sales partner) contacts the respective ZF location and identifies the need
for components and services (Janitza and E+H) using a prepared questionnaire.
2. Janitza Lahnau provides a complete offer including the E+H components for the respective ZF location.
3. Based on this offer, the ZF location orders centrally from Janitza in Lahnau.
4. Janitza Lahnau delivers all components (Janitza and E + H) directly to the ZF location.
5. The installation and commissioning of all components (mechanical, electrical and communication-
technical) must be carried out by ZF or a service provider commissioned by ZF.
6. The installation of the GridVis software, commissioning/parameterization of the Janitza measuring
instruments, the software integration of the E+H measuring instruments and the training/instruction are
carried out by Janitza or a contracted partner, if they have been ordered as a paid service.
Janitza is mandated by ZF as supplier for these applications and offers suitable solutions.
Binding are solely the prices and conditions fixed with ZF in the valid condition agreement.
* Note:
The GridVis Ultimate SE 51.00.195 differs from the catalog article GridVis Ultimate 51.00.190 as follows:
- 1 instead of 2 GridVis Service and GridVis Energy installations
- 2 instead of 5 GridVis desktop installations
The price has been adjusted accordingly.
The basis for the commissioning is in any case our "Condition and Confirmation for Commissioning
Smart(VBI)"
Energy & Power Quality Solutions
in the currently valid version, online at: https://www.janitza.de/inbetriebnahme.html
© by Janitza electronics GmbH, 2018 Seite: 104
Plant Entrance Metering Standard | Project Description
Ordering Information | Individual inhouse and online trainings
Art.-Nr. Name and Description ZF Special Price
Note:
*Travel time, mileage, expenses and overnight stays will be charged additionally at cost.
© All rights reserved. Duplication may be carried out after expressed written permission of Janitza electronics GmbH
only. No liability can be assumed for correctness and completeness. In no case, there is a reliability for damage,
which can occur using the retrieved information.
Holger W. Dietz
Senior Key Account Manager
Janitza electronics GmbH
Vor dem Polstück 6 | D-35633 Lahnau
Tel. +49 6441 9642-535
Mobil: +49 151 46730090
Fax: +49 6441 9642-30
Mail: holger.dietz@janitza.de
Web: www.janitza.de