Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

Radiation survey meter

Radiation survey meter

Sensitivity: : <± 30% (50KeV-1.3MeV).


rm response time: ≤ 3 seconds
Weight: 130g (without batteries)
Dimensions: 150mm x 73mm x 31mm
the relative basic error: <± 10%

Mainly used to detect the radiation measurement of rays.

Radiation survey meter radiation monitor Usage

Mainly used to detect the radiation measurement of χ rays, γ rays and β rays.It is widely used in the field of
non-destructive testing, nuclear submarines, isotope applications, and hospitals cobalt treatment, nuclear p
ower plants around the residents of the background radiation level monitoring.

Radiation survey meter radiation monitor Features

1, high sensitivity, stable and reliable.

2, large LCD, and the Chinese characters display functions, state display at a glance.

3, the measurement of radiation dose rate, display dose rate, the cumulative dose and storage accumulated
dose, multiple dose rate alarm threshold to choose the level select measurement time according to the size
of the dose rate and accuracy requirements, generally measuring the time to choose the 02s, measured dose
select small background dose 10,20 seconds.

4, specialized design background test, testing instruments are in working order, to facilitate the self-
inspection and metrology department examination.

5, with a cumulative dose of memory function, can be permanently stored data after power is not lost.

6, low power consumption, small size, easy to carry.

7, the instrument is simple, easy to use.

8.Within the measuring range can be fixed or preset alarm thresholds, audible and visual alarm exceeds the
threshold or blocked to prevent excessive dose, to protect the safety of staff

9, the instrument has a storage function of cumulative dose. Memory data after power permanent preservat
ion is not lost, 1,000,000 storage erase.

Radiation survey meter radiation monitor Parameters

applicable radiation occasion γ, χ, β-ray.


the measuring range: dose rate: 0.000usv/h-5msv/h
Cumulative dose: 6 LCD 000.000-999.999msv
Sensitivity: <± 30% (50KeV-1.3MeV).
the relative basic error: <± 10% (137Cs Yuen 662 KeVγ, of radiation 1msv / h).
Alarm response time: ≤ 3 seconds
The threshold dose rate alarm: alarm threshold is 0.5,1.0,2.5,10,30,50 usv / h.
low battery voltage indication: Power marked the full three cell battery power is about 2.8V-3.2V
Power marked the two cell battery power is about 2.5V-2.8V
Power marked the one-cell battery is about 2.1V-2.5V,
The power label-free cell battery below 2.1V in less power status.
work environment requirements: Temperature: -10 - +50 °C
Humidity: 90% (non-condensing)
Weight: 130g (without batteries)
Dimensions: 150mm x 73mm x 31mm

Radiation survey meter