Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Optional Probes

HST & Super High Density series

・STERRAD is a registered trademark of JOHNSON & JOHNSON CORPORATION


・The probes are multifrequency in design. Selectable frequencies depend on the
ultrasound system and the display mode. We strive to provide quality
・The standard components and optional items depend on the country. products and services for our customers.
・Connectable probe depends on the ultrasound system.
・Specifications and appearance may be subject to change for improvement without notice. We operate with regard
・For proper use of the system, be sure to read the operating manual prior to placing it into service. for the environment.

2-16-1, Higashi-Ueno, Taito-ku, Tokyo, 110-0015, Japan www.hitachi.com/healthcare


BU-E025 Printed in Japan 2016-04-0.85K-(D)
HST (Hemispheric Sound Technology) and HST+ probes

Convex Sector Probes


HST+ HST+

UST-9147 UST-9130 UST-9135P UST-9132! UST-9132T UST-9146!


Abdomen,OB/GYN Abdomen,OB/GYN Abdominal biopsy Intraoperative Intraoperative Intraoperative
1-6 MHz 1-6 MHz 1-6 MHz Includes puncture 3-10 MHz 3-10 MHz 1-6 MHz
adapter as standard
71 deg./51 mmR 60 deg./60 mmR Puncture adapter 60 deg./60 mmR 65 deg./20 mmR Waterproof 65 deg./20 mmR Waterproof 82 deg./20 mmR Waterproof
MP-2473 connector connector connector
cover: MP-2790 cover: MP-2790 cover: MP-2790

UST-9126* UST-9115-5 UST-9118 UST-9146T


Abdomen,OB/GYN Abdomen,OB/GYN Endo-cavitary Intraoperative
2-6 MHz 3-8 MHz 2-9 MHz 1-6 MHz
60 deg./60 mmR Puncture adapter 60 deg./60 mmR Puncture adapter 180 deg./9 mmR Puncture adapter 82 deg./20 mmR Waterproof
MP-2473 MP-2473 MP-2748 connector
cover: MP-2790

Waterproof
UST-675P UST-9120 connector UST-9133
cover: MP-2790
Endo-cavitary Intraoperative Intraoperative, Biopsy
Small parts Explanatory notes:
2-9 MHz Includes puncture 1-6 MHz
180 deg./9 mmR
adapter MP-2452
as standard.
4-10 MHz 82 deg./20 mmR UST-9130 Model number
70 deg./20 mmR Abdomen,OB/GYN Suggested application ★: Sterrad
Puncture Puncture adapter
1-6 MHz Probe frequency range compatible
adapter for central venous
catheterization
MP-2458
MP-2783* 60 deg./60 mmR Scanning angle (degrees)/
radius of curvature NOTE: Scanning angle, width and selectablefrequencies
*Some ultrasound systems are Puncture adapter Puncture adapter Puncture adapter (mmR), or scanning vary depending on the system, operation mode
not compatible with MP-2783. MP-2781 MP-2781-5 MP-2781-25 width (mm)
and other conditions.

*This probe is not sold in Europe.

2 3
HST (Hemispheric Sound Technology) and HST+ probes
Linear Probes

UST-5417 Elasto
coupler UST-5419 Coupler EZU-PA3C1H
EZU-PA3C1 UST-5415 UST-5713T UST-547 UST-533
MP-2809
Peripheral vessels, Peripheral vessels, Peripheral vessels, Intraoperative Intraoperative Microsurgery
Small parts Small parts Small parts 3-13 MHz 4-13 MHz 4-13 MHz
4-14 MHz 3-7 MHz 4-13 MHz Probe stabilizer 60 mm Puncture adapter 25 mm 10 mm T-type handling tool:
38 mm 38 mm 36 mm MP-2804 MP-2448 MP-2749
Needle guide I-type handling tool:
bracket Coupler MP-2750
EZU-PA7L3 EZU-PA3C2

HST+ HST+

Compound Array Probe

UST-5411 UST-567 UST-5412 UST-5418 UST-5550


Peripheral vessels,Small parts Small parts Peripheral vessels, Laparoscopic surgery Laparoscopic surgery
Small parts 4-way Flexible type Flexeible type
4-13 MHz 3-13 MHz
38 mm 50 mm 4-13 MHz Puncture adapter
2-13 MHz 4-13 MHz Waterproof
38 mm ECM-16 36 mm 38 mm connector
cover: MP-2790
Insertion tube:10mm dia. Insertion tube:10mm dia.

Bi-plane Probe

UST-5410*/UST-5410H* UST-5543 UST-5712 Water Path


Puncture
Peripheral vessels, Peripheral vessels, Small parts adapter
Small parts Small parts 3-13 MHz
4-13 MHz 4-13 MHz 60 mm
37 mm
Puncture adapter
ECM-16 35 mm
MP-2463 UST-678
MP-2456 Bi-plane transrectal
●Convex Sector
3-9 MHz, 120 deg./9 mm Puncture adapter
MP-2451
NOTE: Scanning angle, width and selectablefrequencies
●Linear
vary depending on the system, operation mode
4-13 MHz, 60 mm
and other conditions.

*This probe is not sold in Europe.

4 5
W-SHD(Wide-band Super High Density) probes
Phased Array Sector Probes Convex Sector Probes

HST+

UST-52105 UST-52124 UST-52108 UST-9123 UST-9127 UST-9128 UST-9121


Cardiology Pediatric / Neonatal Cardiology Pediatric / Neonatal Cardiology Abdomen,OB/GYN Abdomen,OB/GYN Abdomen (Intercostal Abdomen (Intercostal
1-5 MHz 3-8 MHz 3-8 MHz 1-6 MHz 1-6 MHz scanning) scanning)
90 deg. 90 deg. 60 deg./60 mmR 60 deg./60 mmR 1-6 MHz 2-6 MHz
90 deg. Puncture Puncture Puncture Puncture
adapter adapter 120 deg./14mmR adapter 120 deg./14 mmR adapter
MP-2473 MP-2473 MP-2474 MP-2474

UST-9136U UST-9124 UST-676P Includes


puncture
UST-677P Includes
puncture
UST-5294-5* UST-5296 UST-5293-5 Abdomen Endo-cavitary Endo-cavitary adapter
as standard.
Bi-plane transrectal adapter
as standard.
Pediatric Cardiology Neonatal Cardiology Rotary-plane TEP 4-13 MHz 3-9 MHz 3-9 MHz Biopsy
100 deg./11 mmR 180 deg./9 mmR 180 deg./9 mmR 3-9 MHz
3-10 MHz 2-10 MHz 2-8 MHz Puncture
180 deg./9 mmR
adapter
90 deg. 90 deg. 90 deg. MP-2748

Linear Probes
HST+

UST-52119S UST-52111S UST-52110S


UST-5413 UST-5548 UST-534 UST-536
Pediatric Rotary-plane TEP Bi-plane TEP for pediatrics Neonatal TEP
Small parts & PV Peripheral vessels Intraoperative Intraoperative
3-8 MHz 3-8 MHz 3-8 MHz
90 deg. 90 deg. 90 deg. 4-13 MHz 3-8 MHz 3-13 MHz 4-13 MHz
38 mm Puncture adapter 42 mm 5 mm 19 mm Waterproof
ECM-16 connector
cover: MP-2790

Phased Array Sector Probes

UST-52126*2
Motor-driven TEP
1-10 MHz UST-568 UST-5298 UST-5299
90 deg.
Small parts & PV Pediatric cardiology Cardiology
3-13 MHz 2-8 MHz 1-5 MHz
NOTE: Scanning angle, width and selectable frequencies vary depending on the system, 50mm 90 deg. 90 deg.
operation mode and other conditions.
* This probe is not sold in Europe.
*2 Please be sure to put the following cover on the probe :
Manufacturer : CIVCO,
Product name : CIV-Flex™ TEE Cover
6 Model number: 610-933 7
SHD (Super High Density) probes

Convex Sector Probes

Puncture
UST-979-3.5 UST-990-5 UST-978-3.5 UST-9104-5 adapter UST-995-7.5 UST-MC11-8731
MP-2458
Abdomen,OB/GYN Abdomen,OB/GYN Abdomen(Intercostal Intraoperative Intraoperative Intraoperative
scanning), Pediatrics Small parts
2-6 MHz 3-8 MHz 4-10 MHz 4-10 MHz
60 deg./60 mmR Puncture adapter 60 deg./60 mmR Puncture adapter
2-6 MHz Puncture adapter
3-8 MHz 65 deg./20 mmR Waterproof connector 65 deg./20 mmR Waterproof connector
Waterproof
MP-2473 MP-2473 90 deg./14 mmR MP-2474 65 deg./20 mmR connector cover: MP-2790 cover: MP-2790
cover: MP-2790

UST-9102-3.5 UST-9102U-3.5 UST-9101-7.5 UST-9113P-3.5 Puncture adapter


is fixed as standard.
UST-670P-5 Includes
puncture
Abdomen Abdomen Abdomen Abdominal biopsy Applicable needle
Endo-cavitary adapter
Size:G18 as standard.
(High resolution)
2-6 MHz 2-6 MHz 2-6 MHz 3-8 MHz
90 deg./20 mmR Puncture adapter 90 deg./20 mmR Puncture adapter
4-13 MHz Puncture adapter 60 deg./60 mmR 120 deg./9 mmR
Cable length:2.0m MP-2414C Cable length:3.5m MP-2414C 60 deg./40 mmR MP-2482

Bi-plane Probe

Waterproof
UST-9112-5 UST-984-5 UST-987-7.5 connector
cover: MP-2790
Endo-cavitary Endo-cavitary Intraoperative
Small parts UST-672-5/7.5
3-8 MHz 3-8 MHz
120 deg./14 mmR Puncture adapter 120 deg./14 mmR Puncture adapter
4-10 MHz Bi-plane transrectal
MP-2445-SET MP-2445-SET 65 deg./20 mmR
●Convex Sector
Puncture Puncture adapter 3-8 MHz, 120 deg./9 mmR
adapter for central venous Puncture adapter
MP-2458 catheterization ●Linear MP-2451
MP-2783*
4-13 MHz, 60 mm
*Some ultrasound systems are
not compatible with MP-2783.

NOTE: Scanning angle, width and selectable frequencies vary depending on the system,
operation mode and other conditions.

8 9
Linear Probes 3D Probes
HST+ HST+

UST-5045P-3.5 Includes
puncture UST-579T-7.5 UST-5534T-7.5 UST-5536-7.5 ASU-1010 ASU-1009 ASU-1012 ASU-1003
adapter
Puncture&biopsy MP-2416U Intraoperative Intraoperative Laparoscopic Obstetrics Obstetrics OB/GYN OB/GYN
2-6 MHz as standard.
4-13 MHz (steered linear) (Flexible type) 2-10 MHz 2-10 MHz 2-8MHz 3-9 MHz
Puncture
80 mm 60 mm adapter 4-13 MHz 4-10 MHz Waterproof Scanning angle Scanning angle Scanning angle Scanning angle
MP-2448 42 mm 33,34,or 38 mm connector
Electronic:60 deg. Electronic:60 deg. Electronic:140 deg. Electronic:163 or 120 deg.*
(Scanning width depends on cover: MP-2790
the ultrasound system.) Mechanical:60 deg. Mechanical:60 deg. Mechanical:90 deg. Mechanical:90 deg.
Waterproof *System dependent
connector
cover: MP-2790

HST+

UST-5542 UST-5710-7.5 UST-5524-7.5 ASU-1011 ASU-1013 ASU-1014


Small parts Small parts Steered linear for Cardiology Small Parts 3D Obstetrics
5-13 MHz 4-13 MHz
small vessels 1-5 MHz 4-13 MHz 1 - 7 MHz
Puncture adapter
29 mm 60 mm Water Path 4-13 MHz ECM-15 Scanning angle Electronic:36 mm Scanning angle
MP-2463 42 mm Electronic:90 deg. Mechanical:33 deg. Electronic: 67 deg.
Mechanical:60 deg. Mechanical:75 deg.
Puncture
adapter
MP-2456

Phased Array Sector Probes Mechanical Probes Independent Probes


Intraoperative Probes Annular Array Sector Mechanical Radial

Includes Includes Insertion length


UST-52114P puncture UST-5268P-5 puncture UST-52109 :375 mm, ASU-36WL-10 ASU-67 UST-2265-2 UST-2266-5
adapter adapter Needle guide
Intraoperative as standard. Intraoperative as standard. End-fire laparoscopic groove :for G18 Small parts, Transrectal for Cardiac CW Doppler Peripheral vessels CW Doppler
3-8 MHz 3-8 MHz probe Diameter :12mm Peripheral vessels sphincter and prostate exam 2 MHz 5 MHz
90 deg. 90 deg. 3-8 MHz 10 MHz/40 deg. Puncture
7.5 & 10 MHz/360 deg.
90 deg. adapter
MP-2493

Waterproof
connector
cover: MP-2790

NOTE: Scanning angle, width and selectable frequencies vary depending on the system,
operation mode and other conditions.

10 11