TCD210155AC Safety Considerations


• Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
• ᜸ symbol indicates caution due to special circumstances in which hazards may occur.

᜸ Warning Failure to follow instructions may result in serious injury or death

01. Fail-safe device must be installed when using the unit with machinery that

Bar Graph
may cause serious injury or substantial economic loss.(e.g. nuclear power
control, medical equipment, ships, vehicles, railways, aircraft, combustion
apparatus, safety equipment, crime/disaster prevention devices, etc.)

Temperature Controllers
Failure to follow this instruction may result in personal injury, economic loss or fire.
02. Do not use the unit in the place where flammable/explosive/corrosive gas,
high humidity, direct sunlight, radiant heat, vibration, impact or salinity
may be present.
Failure to follow this instruction may result in explosion or fire.
03. Install on a device panel to use.
Failure to follow this instruction may result in electric shock.
04. Do not connect, repair, or inspect the unit while connected to a power
source.
Failure to follow this instruction may result in fire or electric shock.
05. Check ‘Connections’ before wiring.
Failure to follow this instruction may result in fire.
06. Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire or electric shock.

᜸ Caution Failure to follow instructions may result in injury or product damage

01. When connecting the power input and relay output, use AWG 20 (0.50 mm2)
cable or over, and tighten the terminal screw with a tightening torque of 0.74
to 0.90 N·m.
When connecting the sensor input and communication cable without
dedicated cable, use AWG 27 to 16 cable and tighten the terminal screw with
a tightening torque of 0.74 to 0.90 N m..
Failure to follow this instruction may result in fire or malfunction due to contact
failure.
02. Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or product damage
03. Use a dry cloth to clean the unit, and do not use water or organic solvent.

KPN Series
Failure to follow this instruction may result in fire or electric shock.
04. Keep the product away from metal chip, dust, and wire residue which flow
into the unit.

PRODUCT MANUAL Failure to follow this instruction may result in fire or product damage.

Cautions during Use


For your safety, read and follow the considerations written in the instruction
• Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected
manual, other manuals and Autonics website.
accidents.
The specifications, dimensions, etc are subject to change without notice for product
• Check the polarity of the terminals before wiring the temperature sensor. For RTD
improvement Some models may be discontinued without notice.
temperature sensor, wire it as 3-wire type, using cables in same thickness and length.
For thermocouple (CT) temperature sensor, use the designated compensation wire for
extending wire.
• Keep away from high voltage lines or power lines to prevent inductive noise. In case
Features installing power line and input signal line closely, use line filter or varistor at power line
and shielded wire at input signal line. Do not use near the equipment which generates
• High speed sampling of 50ms and ±0.3% display accuracy strong magnetic force or high frequency noise.

• Enable to check control output operation amount by adopting bar graph


• Simultaneous heating/cooling control and automatic/manual control for high
performance control
• Selection function of current output or SSR drive output
• Parameter setting available via PC (USB and RS485 communication)
- Free device comprehensive management program (DAQMaster)
• Communication converter sold separately:
SCM-US (USB/Serial converter), SCM-38I (RS232C/RS485 converter) SCM-US48I
(USB/RS485 converter)
• Multi-SV (Max. 4) function (select via digital input terminal)
• Heater break alarm
• CT sold separately: CSTC-E80LN, CSTC-E200LN, CSTS-E80PP
• Small size (rear length: 60 mm)
• Multi input/multi range

ᜢ᜽ ᜫ
-|Transparent Guide|-

• Do not apply excessive power when connecting or disconnecting the connectors of the
product.
Specifications
• Install a power switch or circuit breaker in the easily accessible place for supplying or
Series KPN Series
disconnecting the power.
Power supply 100 - 240 VACᜠ 50/60 Hz
• Do not use the unit for other purpose (e.g. voltmeter, ammeter), but temperature
Permissible voltage
controller. 90 to 110 % of rated voltage
range
• When changing the input sensor, turn off the power first before changing. After changing Power consumption ≤ 15 VA
the input sensor, modify the value of the corresponding parameter. Sampling period 50 ms
• Power supply should be insulated and limited voltage/current or Class 2, SELV power Input specification Refer to 'Input Type and Using Range'.
supply device. CT input • 0.0-50.0 A (primary current measurement range) • CT ratio: 1/1,000
• Do not overlapping communication line and power line. Use twisted pair wire for Option Remote SV 1 - 5 VDCᜡ or 4 - 20 mA (Current Input: External resistance 250 Ω)
communication line and connect ferrite bead at each end of line to reduce the effect of input • Contact - ON: ≤ 2 kΩ, OFF: ≥ 90 kΩ
Digital input
external noise. • Non contact - residual voltage ≤ 1.0 V, leakage current ≤ 0.1 mA
• Make a required space around the unit for radiation of heat. For accurate temperature Relay 250 VACᜠ 5 A 1a
Control
measurement, warm up the unit over 20 min after turning on the power. SSR 11 VDCᜡ±2 V, ≤ 20 mA
output
• Make sure that power supply voltage reaches to the rated voltage within 2 sec after Current DC 4-20 mA or DC 0-20 mA (parameter), load resistance: ≤ 500 Ω
supplying power. Alarm
Relay 250 VACᜠ 3 A 1a
• Do not wire to terminals which are not used. output
• This unit may be used in the following environments. DC 4 - 20 mA (load resistance: ≤ 500 Ω,
Option Transmission
output accuracy: ±0.3% F.S. ±1-digit)
- Indoors (in the environment condition rated in ‘Specifications’) output
RS485 Comm. Modbus RTU
- Altitude Max. 2,000 m
Display type 7 segment (red, green), control output bar graph (red, green), LED type
- Pollution degree 2
Heating,
- Installation category II
Control Cooling
ON/OFF, P, PI, PD, PID Control
type Heating &
Cooling
Ordering Information • Thermocouple, RTD: 1 to 100 (0.1 to 100.0) ℃/℉
Hysteresis
• Analog: 1 to 100 digit
This is only for reference, the actual product does not support all combinations.
Proportional band (P) 0.1 to 999.9 ℃/℉ (0.1 to 999.9%)
For selecting the specified model, follow the Autonics website . Integral time (I) 0 to 9,999 sec
Derivative time (D) 0 to 9,999 sec
K P N 5 ❶ ❷ - ❸ ❹ ❺ • 0.1 to 120.0 sec [relay output model]
Control cycle (T)
• 1.0 to 120.0 sec [SSR drive output model]
❶ Size ❸ Option Communication Manual reset 0.0 to 100.0%
2: DIN W 96 × H 48 mm output Relay Mechanical ≥ 10,000,000 operations
3: DIN W 48 × H 96 mm 0: No life
cycle Electrical ≥ 100,000 operations (load resistance: 250 VACᜠ 3 A)
5: DIN W 96 × H 96 mm 2: RS485
Between the charging part and the case: 3,000 VAC ~ 50/60 Hz for 1
Dielectric strength
❷ Control output ❹ Option in/output minute
0: No 0.75 mm amplitude at frequency of 5 to 55 Hz in each X, Y, Z direction
Output Type Vibration
PN 3: Transmission output + for 2 hours
number Heating: OUT1 Cooling: OUT2
Remote SV Insulation resistance ≥ 100 MΩ (500 VDCᜡ megger)
1 (Heating or Relay, selectable current or SSR drive
00 ±2 kV square shaped noise (pulse width 1 ㎲) by noise simulator
Cooling) output Noise immunity
❺ Power supply R-phase, S-phase
11 Selectable current or SSR drive output
Selectable current 0: 100-240 VACᜠ Memory retention ≈ 10 years (non-volatile semiconductor memory type)
13 2 (Heating & or SSR drive output Relay
Ambient temperature -10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
Cooling)
Selectable current Ambient humidity 35 to 85%RH, storage: 35 to 85%RH (no freezing or condensation)
17 Relay
or SSR drive output
Protection structure IP65 (front panel, IEC standards)
19 Relay
Double or reinforced insulation (mark: ▱, dielectric strength between
Insulation type
the measuring input part and the power part: 2 kV)
Certification ᜢ᜽ᜫ
Product Components • KPN52□-□: ≈ 160 g (≈ 230 g) • KPN53□-□: ≈ 160 g (≈ 230 g)
Unit weight
• Product (+ bracket) • Instruction manual (packaged) • KPN55□-□: ≈ 220 g (≈ 316 g)

Manual Communication Interface


For proper use of the product, refer to the manuals and be sure to follow the safety ■ RS485
considerations in the manuals. Comm. protocol Modbus RTU
Download the manuals from the Autonics website. Connection type RS485
Application standard EIA RS485 compliance with
Maximum connection 31 units (address: 01 to 127)
Software Synchronous method
Comm. Method
Asynchronous
Two-wire half duplex
Comm. effective range ≤ 800 m
Download the installation file and the manuals from the Autonics website.
Comm. speed 2,400 / 4,800 / 9,600 (default) / 19,200 / 38,400 bps (parameter)
■ DAQMaster Response time 5 to 99 ms (default: 20 ms)
Start bit 1 bit (fixed)
DAQMaster is comprehensive device management program. It is available for
Data bit 8 bit (fixed)
parameter setting, monitoring. Parity bit None (default), Odd, Even
Stop bit 1 bit, 2 bit (default)
EEPROM life cycle ≈ 1,000,000 operations (Erase / Write)
Sold Separately
• Terminal protection cover: RHA / RLA-COVER • Current transformer (CT)
• Communication Converter: SCM-US / SCM-38I / SCM-US48I / SCM-WF48
-|Transparent Guide|-

Input Type and Using Range Unit Descriptions


The setting range of some parameters is limited when using the decimal point display. 1. PV display part (Red)
Decimal • Run mode: Displays PV (Present value).
Input type Display Using range (℃) Using range (℉)
point • Setting mode: Displays parameter name.
1 -200 to 1,350 -328 to 2,462
K (CA) 1 2. SV display part (Green)
TcK1
0.1 -199.9 to 999.9 -199.9 to 999.9
• Run mode: Displays SV (Setting value).
TcK2
1 -200 to 800 -328 to 1,472 4
J (IC) 4
TcJ1
0.1 -199.9 to 800.0 -199.9 to 999.9 • Setting mode: Displays parameter setting value.
2
TcJ2
1 -200 to 800 -328 to 1,472
E (CR) 3. Input key
TcE1
0.1 -199.9 to 800.0 -199.9 to 999.9
Display Name
TcE2
1 -200 to 400 -328 to 752 5
T (CC) [A/M] Control Switching key
TcT1
0.1 -199.9 to 400.0 -199.9 to 752.0
[MODE] Mode key
TcT2
B (PR) 1 0 to 1,800 32 to 3,272
 hermo
T
[◀], [▼], [▲] Setting value control key
TC-B
R (PR) 1 0 to 1,750 32 to 3,182
-couple TC-R
3
S (PR) 1 TC-S 0 to 1,750 32 to 3,182 4. Indicator
N (NN) 1 TC-N -200 to 1,300 -328 to 2,372 Display Name Description
C (TT) 01) 1 0 to 2,300 32 to 4,172
Manual
MAN Turns ON during manual control
TC-C
G (TT) 02) 1 0 to 2,300 32 to 4,172
TC-G
control
1 -200 to 900 -328 to 1,652
L (IC) %, ℉, ℃ Unit Displays selected unit (parameter)
TcL1
0.1 -199.9 to 900.0 -199.9 to 999.9
Turns ON when the control output is ON
TcL2
1 -200 to 400 -328 to 752
U (CC) Control • Current output
TcU1
0.1 -199.9 to 400.0 -199.9 to 752.0 OUT1/2
output M
 anual control: 0% OFF, over ON
TcU2
Platinel II 1 0 to 1,390 32 to 2,534
Auto control: below 2% OFF, over 3% ON
TC-P
Cu50 Ω 0.1 -199.9 to 200.0 -199.9 to 392.0 6
AT Auto tuning Flashes during auto tuning every 1 sec
Cu50
Cu100 Ω 0.1 -199.9 to 200.0 -199.9 to 392.0
RSV Remote SV Turns ON during remote SV control
Cu10
1 -200 to 650 -328 to 1,202
JPt100 Ω Alarm
JPt1
0.1 -199.9 to 650.0 -199.9 to 999.9 AL1/2/3 Turns ON when the alarm output is ON
RTD output
JPt2
DPt50 Ω 0.1 -199.9 to 600.0 -199.9 to 999.9
The SV indicator is ON which is currently
DPt5
1 -200 to 650 -328 to 1,202 SV1/2/3 Multi SV
DPt100 Ω displayed. (When using multi SV function)
DPt1
0.1 DPt2 -199.9 to 650.0 -199.9 to 999.9
Nickel120 Ω 1 Ni12 -80 to 200 -112 to 392  ar graph: Refer to 'Bar Graph'.
5. B
0 to 10 V - 0~ 10 V
6. PC loader port: F or connecting communication converter
A-V1
0 to 5 V - 0~ 5 V
(sold separately).
A-V2
1 to 5 V - 1~ 5 V
Analog
A-V3
0 to 100 mV - aMV1 0~ 100 mV
0 to 20 mA - 0~ 20 mA
Bar Graph
aMA1
4 to 20 mA - aMA2 4~ 20 mA
01) C (TT): Same as existing W5 (TT) type sensor
02) G (TT): Same as existing W (TT) type sensor MV of control output (OUT1, OUT2) is displayed as the bar graph in real-time. According
• Permissible line resistance per line: ≤ 5 Ω to bar graph setting in parameter 5 group, it displays bar graph by control output or
does not display it.
■ Display accuracy
Input type Using temperature Display accuracy OUT1 (Red LED)
(PV ±0.3% or ±1 ℃ higher one) ±1-digit 50 100
• Thermocouple K, J, T, N, E below -100 ℃ and L, U, PLII, RTD Cu50 Ω, OUT2 (Green LED)
At room temperature DPt50 Ω: (PV ±0.3% or ±2 ℃ higher one) ±1-digit
One LED is 10% (total 10 LEDs: 100%). If control output MV is 0.1 to 10%, one LED turns
(23℃ ±5 ℃) • Thermocouple C, G and R, S below 200 ℃:
Thermo (PV ±0.3% or ±3 ℃ higher one) ±1-digit ON. If MV is 90.1 to 100%, 10 LEDs turn ON.
-couple • Thermocouple B below 400 ℃: There is no accuracy standards The 1 output type (heating or cooling control) model has one OUT1 bar graph (red).
RTD (PV ±0.5% or ±2 ℃ higher one) ±1-digit
• RTD Cu50 Ω, DPt50 Ω: (PV ±0.5% or ±3 ℃ higher one) ±1-digit The 2 output type (heating & cooling control) model has two bar graphs: OUT1 bar
Out of room
temperature range
• Thermocouple R, S, B, C, G: graph (red), OUT2 bar graph (green). OUT1 is for heating MV and OUT2 is for cooling MV.
(PV ±0.5% or ±10 ℃ higher one) ±1-digit
• Other sensors: ≤ ±5 ℃ (≤-100 ℃)
At room temperature
±0.3% F.S. ±1-digit
(23℃ ±5 ℃)
Analog
Out of room
±0.5% F.S. ±1-digit
temperature range
-|Transparent Guide|-

Dimensions Connections
• Unit: mm, For the detailed drawings, follow the Autonics website. • Shaded terminals are standard model. is option specification.
• Below is based on KPN52□-□ Series.

■ Panel cut-out Communication 1 RS485


13 Remote SV
A C D Output
RS485(A+)
Circuit ADC V mA 1-5V
E G RS485
2 14 4-20mA
(Comm. output) RS485(B-)

AL1 OUT Relay 3 15

J
250VAC 3A 1a
Digital
I RESISTIVE LOAD

DI-1
Input
4 16

F
B

H
AL2 OUT Relay Non contact,
Control
250VAC 3A 1a Circuit contact Input

DI-2
RESISTIVE LOAD 5 17
AL3 OUT Relay
Body Panel cut-out 250VAC 3A 1a
A B C D E F G H I J RESISTIVE LOAD 6 18 Analog Output
Output mA
DC4-20mA
KPN52□-□ 96 48 6 64.5 1.5 44.7 ≥ 115 ≥ 65 92+00.8 45+00.6 OUT1 Relay Circuit (Transmission output)/
250VAC 5A 1a 7 19 24VDC(LPS)
KPN53□-□ 48 96 6 64.5 1.5 91.5 ≥ 65 ≥ 115 45+00.6 92+00.8 RESISTIVE LOAD
KPN55□-□ 96 96 6 64.5 1.5 91.5 ≥ 115 ≥ 115 92 +0.8
0 92 +0.8
0 Current SSR 8 20 Current
DC0/4-20mA 11VDC±2V CT Transformer
ADC
■ Bracket
Load 500ΩMax. 20mA Max. Output
0.0-50.0A
9 Circuit 21
mA V
A
3.3

10 22 Analog
0-100mV
B
46 11 23 0-5V
4

mA
SOURCE ADC
1-5V
100-240VAC, Power V
Circuit B' 0-10V
50/60 Hz 12 24 0-20mA
37.5
40.5

RTD TC 4-20mA
KPN5□-□10 Sensor
12
23.9 7 OUT2 Relay
mA V 250VAC 5A 1a
RESISTIVE LOAD
Current SSR 8
Installation Method
DC0/4-20mA 11VDC±2V
Load 500ΩMax. 20mA Max.
9 OUT1 Relay
mA V 250VAC 5A 1a
10 RESISTIVE LOAD

Crimp Terminal Specifications


• Unit: mm, Use the crimp terminal of follow shape.

Flathead screwdriver

Insert the unit into a panel, fasten the bracket by pushing with tools with a flathead
≥3.0
screwdriver. ≥3.0
≤5.8
≤5.8

Fork crimp terminal Round crimp terminal


Errors
Display Input Description Output Troubleshooting Initial Display When Power is ON
Flashes at 0.5 sec interval when 'Sensor error,
Temperature Check input When power is supplied, after all display will flash for 1 sec, model name is displayed
input sensor is disconnected or MV' parameter
sensor sensor status.
sensor is not connected. setting value sequentially. After input sensor type will flash twice, enter into RUN mode.
'Sensor error,
OPEN
Flashes at 0.5 sec interval when Check analog 3. Input
Analog MV' parameter 1. All display 2. Model 4. Run mode
input is over F.S. ±10%. input status. specification
setting value
Flashes at 0.5 sec intervals if the PV display part ***8
Temperature Heating: 0%,
KP53 KP53 OPEN
input value is above the input SV display part ***8
sensor Cooling: 100%
Ii23 TcK1 0
range.01)
Flashes at 0.5 sec intervals if the
HHHH

input value is over 5 to 10% of high Normal output When input is


Analog
limit or low limit value. within the rated Mode Setting
input range,
Flashes at 0.5 sec. intervals if the
Temperature Heating: 100%, this display Key input Entering mode
input value is below the input disappears. Auto before
sensor Cooling: 0% Password Pass Auto Selected mode
range.01) entering to mode

(When using input [◀], [▲], [▼] Password input
Flashes at 0.5 sec intervals if the
LLLL
password) Fail
Analog input value is over 5 to 10% of low Normal output [MODE] Run mode
limit or high limit value.
Move digits: [◀] Save: [MODE]
Temperature
Flashes at 0.5 sec intervals if there [◀], [▲], [▼] → SV setting Change value: or no key input →
sensor Check setting [▲], [▼] over 3 sec
is error for setting and it returns to -
method.
Parameter →
ERR
Analog the error-before screen.
RUN [MODE] → [MODE] over 3 sec
Group
01) Be careful that when HHHH / LLLL error occurs, the control output may occur by recognizing the
maximum or minimum input depending on the control type. [◀] + [▲] + [▼] Parameter
→ Auto → RUN
over 5 sec reset
Auto/Manual
[A/M] → Control [A/M] →
Switching
[▲] + [▼] over 3
→ Digital input Auto →
sec
-|Transparent Guide|-

Parameter Setting Function: Alarm


• Some parameters are activated/deactivated depending on the model or setting of Set both alarm operation and alarm option by combining.
other parameters.
88* 8 Each alarm operates individually in two alarm output models.
Alarm Alarm When the current temperature is out of alarm range, alarm clears
• The 'Parameter mask' feature, which hide unnecessary or inactive parameters, and operation option automatically.
the 'User parameter group' feature, which quickly and easily set up certain parameters
that are frequently used, can be set up in DAQMaster. ■ Operation • H: Alarm output hysteresis
• Refer to the user manual for the details. Name Alarm operation Description
■ Parameter 1 group ■ Parameter 4 group - - No alarm output
OFF H ON OFF H ON If deviation between PV and
Parameter Display Default Parameter Display Default SV as high-limit is higher
Control output Alarm output1 operation Deviation SV PV PV SV than set value of deviation
RUN/STOP mode high limit 100℃ 110℃ 90℃ 100℃
temperature, the alarm
R-S RUN AL-1 DVCC
Multi SV selection SV-N SV-0 Alarm output1 option AL!T AL-A High deviation: Set as 10℃ High deviation: Set as -10℃ output will be ON.
Heater current Alarm output1 ON H OFF ON H OFF If deviation between PV
monitoring Hysteresis and SV as low limit is higher
CT-A )0 A!HY 001
Deviation
Alarm output1 low limit Alarm output1 contact
PV SV SV PV than set value of deviation
low limit 90℃ 100℃ 100℃ 110℃
AL!L 1550
Alarm output1 high limit type
A!N NO temperature, the alarm
Low deviation: Set as 10℃ Low deviation: Set as -10℃ output will be ON.
AL!H 1550
Alarm output2 low limit AL@L 1550 Alarm output1 ON delay
Alarm output2 high limit time
A!ON 0000
ON H OFF H ON If deviation between PV
Deviation and SV as high/low-limit
AL@H 1550
Alarm output3 low limit Alarm output1 OFF delay
high, low PV SV PV is higher than set value of
AL#L 1550
Alarm output3 high limit time
A!OF 0000
90℃ 100℃ 110℃
limit deviation temperature, the
AL#H 1550
Multi SV 0 Alarm output2 operation High, Low deviation: Set as 10℃ alarm output will be ON.
mode
SV-0 0000
Multi SV 1
AL-2 ]]DV
If deviation between PV and
SV-1 0000
OFF H ON H OFF
Multi SV 2 Alarm output2 option
Deviation SV as high/low-limit is lower
SV-2 0000 AL@T AL-A
Multi SV 3 SV-3 0000 Alarm output2 hysteresis A@HY 001 high, low PV SV PV than set value of deviation
90℃ 100℃ 110℃
Alarm output2 contact limit reverse temperature, the alarm
■ Parameter 2 group type
A@N NO
High, Low deviation: Set as 10℃ output will be OFF.
Parameter Display Default Alarm output2 ON delay OFF H ON OFF H ON
time Absolute If PV is higher than the
A@ON 0000
Auto tuning RUN/STOP
Alarm output2 OFF delay value high PV SV SV PV absolute value, the output
AT OFF
Heating proportional limit 90℃ 100℃ 100℃ 110℃
will be ON.
band time
A@OF 0000
Absolute value: Set as 90℃ Absolute value: Set as 110℃
H-P 01)0
Cooling proportional Alarm output3 operation
band mode ON H OFF ON H OFF
AL-3 LBA
Absolute If PV is lower than the
C-P 01)0
Heating integral time Alarm output3 option AL#T AL-A value low PV SV SV PV absolute value, the output
100℃ 110℃
H-1 0000
90℃
Cooling integral time Alarm output3 hysteresis A#HY 001 limit 100℃
will be ON.
Absolute value: Set as 90℃ Absolute value: Set as 110℃
C-1 0000
Heating derivative time Alarm output3 contact
type It will be ON when it detects
H-D 0000
Cooling derivative time Sensor break -
A#N NO

Alarm output3 ON delay sensor disconnection.


C-D 0000
Dead overlap band
time It will be ON when it detects
DB 0000 A#ON 0000
Manual reset Heater break -
Alarm output3 OFF delay heater disconnection.
REST 05)0
Heating hysteresis
time It will be ON when it detects
hHYS 002 A#OF 0000
Heating OFF offset Loop break -
hOST 000
LBA time loop disconnection.
Cooling hysteresis
LBaT 0000
LBA band
■ Option
cHYS 002
Cooling OFF offset
LBaB 002
Analog transmission
cOST 000
MV low limit
output Condition
L-MV `0)0 AoM PV
MV high limit Name Description
H-MV 10)0
PV transmission output of re-apply
RAMP up change rate
low limit Standard If it is an alarm condition, alarm output is ON. If it is a clear alarm
RAMU 000 FS-L -200
RAMP down change rate -
RAMD 000
PV transmission output alarm condition, alarm output is OFF.
RAMP time unit rUNT MIN high limit
FS-H 1350
If it is an alarm condition, alarm output is ON and maintains ON
Alarm latch -
Communication address ADRS status.
■ Parameter 3 group 01
Communication speed First alarm condition is ignored and from second alarm
Parameter Display Default
BPS 96
Comm. parity bit Standby condition, standard alarm operates. When power is supplied
Input specification sequence 1 and it is an alarm condition, this first alarm condition is ignored
PRTY NONE
Comm. stop bit
IN-T KCaH
Temperature unit and from the second alarm condition, standard alarm operates.
STP 2
Response time Power ON
UNIT ><?C
Analog low limit Alarm If it is an alarm condition, it operates both alarm latch and
RSWT 20
Comm. write
L-RG 0)00
Analog high limit
COMW EnA latch and standby sequence. When power is supplied and it is an alarm
standby condition, this first alarm condition is ignored and from the
H-RG 1)00
Scaling decimal point DOT )0 ■ Parameter 5 group sequence 1 second 1alarm condition, alarm latch operates.
Low limit scale
Parameter Display Default First alarm condition is ignored and from second alarm
L-SC 00)0
High limit scale Power ON,
Multi SV number condition, standard alarm operates. When re-applied standby
H-SC 10)0
Display unit Standby change SV,
MtSV 1
Digital input key sequence and if it is alarm condition, alarm output does
dUNT >?/O
Input correction sequence 2 change
not turn ON. After clearing alarm condition, standard alarm
DI-K STOP
Digital input1 Terminal
IN-B 0000
Input digital filter operates. alarm
Function temperature
MAvF 00)1 DI-1 OFF
SV low limit Basic operation is same as alarm latch and standby sequence1.
Digital input2 Terminal Alarm / operation
L-SV -200
SV high limit It operates not only by power ON/OFF, but also alarm set value,
Function latch and or change
H-SV 1350 DI-2 OFF
or alarm option changing. When re-applied standby sequence STOP to RUN
Remote SV standby
HEAT
(Output and if it is alarm condition, alarm output does not turn ON. mode
ReSV OFF
Remote SV low limit sequence 2
Control output mode
number: 1) After clearing alarm condition, alarm latch operates.
correction
O-FT R1nB 0
H-C
(Output Remote SV high limit
number: 2) gradient correction
RSPN !00
PID
(Output
OUT1
(Output
number: 1)
Control type C-MD Bar graph BAR
number: 1)
pP
(Output
ALL
(Output
number: 2)
number: 1)
Auto tuning mode
Manual control, initial
AtT TUN1
MV
RLY ItMV AUTO
(Output
OUT1 control output number: 1) Manual control, preset
selection MV
OUT1 PrMV 00)0

Sensor error, MV
SSR
(Output ErMV 00)0
number: 2) Control stop, MV
OUT1 current output
StMV 00)0
Control stop, alarm
range output
O!MA 4-20 StAL CONT
OUT2 control output User level
selection
OUT2 SSR USER STND
SV setting lock
OUT2 current output
LcSV OFF
range
O@MA 4-20 Parameter 1 group lock LcP1 OFF
Parameter 2 group lock
Heating control cycle
LcP2 OFF
Parameter 3 group lock
02)0
(Relay)
H-T LcP3 OFF
Parameter 4 group lock
Cooling control cycle
00)0 LcP4 OFF
(SSR) Parameter 5 group lock
C-T
LcPS OFF
Password setting PWD 0000
-|Transparent Guide|- -

Sold Separately: Terminal Protection Cover Segment Table


• Unit: mm The segments displayed on the product indicate the following meanings. It may differ
RHA-COVER: DIN W48 × H96 RLA-COVER: DIN W96 × H96 depending on the product.
3.8 47.2 9 3.8 94 10 7 Segment 11 Segment 12 Segment 16 Segment
0 0 I I 0 0 I I 0 0 I I 0 0 I I
UP UP
1 1 J J 1 1 J J 1 1 J J 1 1 J J
2 2 K K 2 2 K K 2 2 K K 2 2 K K
3 L 3 L 3 L 3 L

91.5
91.5

3 L
DOWN

3 L 3 L 3 L

86
86
UP

4 4 M M 4 4 M M 4 4 M M 4 4 M M
5 5 N N 5 5 N N 5 5 N N 5 5 N N
DOWN DOWN 6 6 O O 6 6 O O 6 6 O O 6 6 O O
7 7 P P 7 7 P P 7 7 P P 7 7 P P
8 Q 8 Q 8 Q 8 Q

13
13

8 Q 8 Q 8 Q 8 Q
9 9 R R 9 9 R R 9 9 R R 9 9 R R
A S A S A S A S
Sold Separately: Current Transformer (CT)
A S A S A S A S
B B T T B B T T B B T T B B T T
C U C U C U C U
• Unit: mm
C U C U C U C U
• The current for above CTs is 50A same but inner hole sizes are different. Please use this D D V V D D V V D D V V D D V V
for your environment. E W E E W W E W E W
• Do not supply primary current in case that CT output is open. High voltage will be
E W E W E W
F X F X F X F X
generated in CT output.
F X F X F X F X
G G Y Y G G Y Y G Y G Y
CSTC-E80LN
G Y G Y
H H Z Z H H Z Z H H Z Z H H Z Z
Ø23.3 F=50Hz
Ø7
10
3 Ta=25℃
100Ω
K(Black)
OUTPUT IN VOLTS RMS(V)

1 10Ω
7

L(White)
3.8

26.5 150 0.1


10.5

0.01
• Max. load current: 80A (50/60Hz)
• Current ratio: 1/1000 0.001
• Wire wounded resistance: 31Ω±10% 0.1 1 10 100 1000
SENSED CURRENT IN AMPS RMS(Io)

CSTC-E200LN
Ø37.1 F=50Hz
10
Ø13 3 Ta=25℃ 100Ω

10Ω
K(Black)
OUTPUT IN VOLTS RMS(V)

1
10

L(White)
4.5

0.1
40.8 150

0.01
13.5

• Max. load current: 200A (50/60Hz) 0.001


• Current ratio: 1/1000 0.1 1 10 100 1000
• Wire wounded resistance: 20Ω±10% SENSED CURRENT IN AMPS RMS(Io)

CSTS-E80PP
21.4 F=50Hz
15.4 2.9 10 Ta=25℃ 100Ω
0.5
10Ω
Ø6
OUTPUT IN VOLTS RMS(V)

1
7
25.4

0.1
2.7
10.5

40.2
31 0.01
Ø3.4

0.001
10

0.1 1 10 100 1000


• Max. load current: 80A (50/60Hz) SENSED CURRENT IN AMPS RMS(Io)
• Current ratio: 1/1000
• Wire wounded resistance 31Ω±10%