BROSUR Fixed Cathlab

You might also like

Download as pdf
Download as pdf
You are on page 1of 10
Allengers Passion for excellence Advance Angiography | system for cardiac, neuro and vascular interventions under one roof Fixed per lie Altima Series With New “Synergy” Software Altima F100 Allengers-Altima F100 uses state-of the-art digital technology for superb performance, improved reliability, ease of use to meet the expectations of Cardiologists to give a single solution for Cardiacand VascularImaging. Salient Features : Large displays in Altima series enhances your viewing experience ‘ona single monitor Detector size 20x20 cm/30x30cm. IKX1K/15Kx15K resolution. 55" high resolution, high luminous coloured monitor with multiple display options. Distortion free imaging. Motorized rotation and up / down movement of detector. 1100 KW dual invertor based generator. Liquid metal tube for toughest clinical demands. Online Digital Subtraction Angiography. ASSURE Protocols forradiation protection, Stentview. REAL DOSE * § DOSE" : = Dose management display in real time. = Frame rate settings. 1 Tube heating can be controlled 1 Radiation dose can be controlled. Multiple display 2 x 2 eas Radiation eeraelitiiebn Bar = Multiple display 1x2 Rotational Movement of FPD Anti Collision Proximity Sensor (Ensures all related views) (Ensures safety to patient) Clinical | ee eee eee ee Images with FP.D drivers in the development of our imaging portfolio.” Coronary Images Stent View | Real time enhanced view of stents ‘A deployed stent is sometimes hard to see which makes it dificult for the physician to judge proper outcome of the procedure. Stent view is a processing package that enhances the visibility of the deployed stent. Everything is fully automatic, The resultis available in minimum processing time. Stent view is simple and easy ‘tose that helps to improve the long-term success of the interventional procedure. Altima c1oo Allengers-Altima C100 uses state~ superb performanc the-art technology for y, ease of use to meet proved relat the expectations of Cardiologists to give a single solution for Cardiacand Vascularimaging. Salient Features : 9" image intensifier. Abit 1kx1K CCD camera 55" high resolution, high luminous coloured monitor with multiple display options. Low noise for clear visualization. Motorized up / down movement of mage intensifier, ‘100 KW dual invertor based generator. Liquid metal tube for toughest clinical demands. Digital Subtraction Angiography. ASSURE Protocols forradiation protection Clinical Images with LI C-Arm Movements. RAO. Lao aT L-Arm Movements. Movement of L-Arm (490°) helps in conducting various interventional procedures like Pacemaker Implantation, Radial and Peripheral Interventions. Table Movements. Pivot movement of table top (+90 degrees) with electromagnetic locks to stop at any desired position. This movement provides quick access to the patient in emergency situations for resuscitation. Console | Room NEW SYNERGY SOFTWARE Efficient Digital Imaging Workflow (DICOM 3.0) Imaging Software: 1» Image acquisition up to 30 fps @ 1K x 1K resolution in fluoro and cine. 8 Fluoro store facility. 1» Real time edge enhancement, positive / negative image display, window level adjustment, contrast / brightness, electronic collimator, vertical and horizontal image flip, image rotation, zoom with pan function. 1 Measurements -length, angle, stenosis and area, 1 QCA /QLVA. = DICOM3.0 compatible image communication network. = DICOM patient CD / DVD recorder. DICOM / paper printready. 1 Real time online DSA, road map, pixel shifting, re-masking and peak opacification (optional) Monitors (2 Nos): High resolution and high luminance monitors =1No. 27" Live Monitor =1No.19" Monitor Patient Table | Controls Pause Shifting from live to reference Moon Shatter, Magnification Joy Stick Next Parallel Shutter Reverse Joy Stick Save + Newt 5 peverse Patient Table post tent able Joy Stick ay Joy Stick ¥ Roadmap Long Lever Joy Stick primary beam and scattered radiation and keeps them far below the safe radiation limits ra oN Allengers ASSURE Protocols mechanism ensures minimum radiation dose to the operational « staff and patient in procedure room. ASSURE Protocols uses different devices to control the Upper / Lower Body Protection: Ceiling suspended lead protection screen and lead flaps ensures radiation safety for upperand lower body. Integrated Dose Area Product Meter: Measures the effective dose delivered and keeps the patient dose to the minimum, Radiation Free Preview Collimator Radiation free preview collimator can be applied at any desired location without X-Ray exposure. Ultra Fast Collimator: Ultra fast collimator with fine adjustment of LEAD blades to block extra radiation in REAL TIME. MultiBeam Hardening Filter: Blocks soft radiation at all dose levels and keeps the dose constant at all levels of X-Ray exposure ensuring consistent image quality. Grid Switching: Reduces soft X-Ray dose to the patient by eliminating the TAIL of exposure pulse SID Control: Variable Source to Image Distance reduces X-Ray dose by minimizing the distance between X-Ray source and image receptor. 3° EC E| Collimation ! ty aah ic Tired iter Muli Beam Fier > JO esi Grid Realize the hidden potential with Altima's smart features and other par excellence capabilities to enhance your cathrooms peak performance ‘SMART Features : B__ smart quick collimator : Optimizes the radiation in real time. © Monitor is mounted on boom : Facilitates quick adjustments in any position. GD Accurate dose wise program : Manages the dose very wel MBF maintains the dose and keeps quality at its optimum GB __ Remote service : Facilitates easy system upgrades for improved experience. Things kept simply effective : Same keys / same functions keeps things simple. Other Features : = QCAcanbe performed simultaneously in console room while procedure is going on in the exam room, 1 Mult-tasking is possible to save time. Instantly review the previous image while preparing for the next patient exam. 1 HIS/RiSinterface: Display of checklist and protocols from RIS / HIS saves time. 1 Design based uponuser feedback 1 Real time dose monitoring and dose management. Optional : ® Uninterrupted power supply for complete equipment - Safety of the equipment from erratic power supply lines and poorearthing, ~ Avoid! total blackouts in critical moments during power failures. - Stable power supply adds to equipmentlife. Room Dimensions STANDARD ROOM PLAN FOR FIXED CATHLAB (with ceiling suspended monitors stand) i B® ¢ [eesti some = & coerce Aish £ i i 3 fg) = " dihkep ¢ BYES 0) watt} winrmecen Yd MAJOR TECHNICAL SPECIFICATIONS* | ered Ea ‘Altima F100) ere Output Power 1100 KW with FPD 1100 KW with Image Intensifier () Stabilized 3-phase, 100/125 KW, 400V AC, +10%, 50 Hz. Suitable rated UPS for entire Cathlab equipment Power Requirement * These are broader specifications with highest certifications. The final product will be dispatched as per agreed terms in quotation. ASSURE (Allengers Safety Standard for User from Radiation Emission) ASSURE Protocols: All X-Ray based equipments invlve some potential sk of radiation exposure. We, at Allengers understand your concems. ‘Allengers sully committed tovrardsraciation safety and cre ofits customers ‘Allengers has introduced AS SURE Protocols, whichis a step in the direction of delivering best possible image quality at lowest possible dose. ‘Allengers products with ASSURE Protocols are carefully crafted to protect users and patients from unwantedleakagesin the X-Ray equipment. 3 configurations and may change for desired models. ASS.UR.Eversion mentioned: ALLENGERS MEDICAL SYSTEMS LTD. sased upon ‘SCO. 212-213-214, Sector 34-A, Chandigarh-UT. 160 022 (nda) Follow us on: wwremedicasebonong DOMESTIC SALES | Ginieal 8106) for clinical eases studies Ph: +91 172 6618000-99, 2621913 Fax: +91 172 2621912 E-mail: sales enquiry@allenges net Medi INTERNATIONAL SALES Case JB Ph: +91 172.6618081, 6518082 Fax: +91 172 2621912 E-mail: exports@allengersnet me Please visit wwallengers.com for more information Toll Free No. 1800-266-8800 (India), where opinion and care maters. For detailed technical specifications, please refer to the respective product data sheets / quotation, Due te continuous product impravements, specications and appearance ae subject to change without prior notice. paesvoc ssa

You might also like