SODIUM HYPOCHLORITE GENERATOR A PERFORMANCE TEST RECORD

Purchase Order No. : PO. 86379/PE/POMI/23 Tagging Number : CCL-GEN-510A


Project Name : REPLACE SODIUM HYPOCHLORITE CELL TRAIN A Date of Test : 04 October 2023
Owner/Client : PT. Paiton Operation Maintenance Indonesia Note : Tested by PT. Mandala Setia, conducted with HACH
Contractor : PT. Mandala Setia Standard test procedure
Ambient Temp. : 31 deg. C

Time Each Cell Voltage (V.) Supplied Corrected


DC Output Chlorine Chlorine Faraday
DC Output AC electric Seawater Chlorine
No. Load (%) Voltage Concent Production Production
Current (Amp) Setting Sampling power (kW) 1 2 3 4 Flow Rate Concent ration
(V.) ration (mg/l) (Kg-Cl₂/hr) (%)
(m³/h) (mg/l)
7600,00 100% 1453,00 max. 180 45 45 45 45 155,00 1748,00 1748,00 270,94 74,9

Prepared by, Checked by, Approved by,

Emha Ridwan Arrosyid Bacharuddin Sapto Adi Bambang Sarwoko


PT. Mandala Setia PT. Mandala Setia PT. Paiton Operation Maintenance Indonesia
Corrected Chlorine Concent ration (mg/l)

Rc = Oc-Ic+(Ax10)+(Bx2.2)

Rc : Corrected available chlorine concentration (mg/l)


Oc : Available chlorine concentration at electrolyzer outet (mg/l)
Ic : Available chlorine concentration at electrolyzer inlet (mg/l)
A : Ammonia nitrogen concentration at electrolyzer inet (mg/l)
B : COD concentration at electrolyzer inlet (mg/l)