The document summarizes the results of a performance test of a sodium hypochlorite generator. The test was conducted on October 4, 2023 at PT. Paiton Operation Maintenance Indonesia. Key findings include: the ambient temperature was 31 degrees C, the DC output voltage was a maximum of 180V, and the corrected chlorine concentration was 1748 mg/l, resulting in a chlorine production of 270.94 kg-Cl2/hr and 74.9% of theoretical Faraday efficiency. The test was prepared by Emha Ridwan Arrosyid and approved by Bambang Sarwoko of PT. Paiton Operation Maintenance Indonesia.
The document summarizes the results of a performance test of a sodium hypochlorite generator. The test was conducted on October 4, 2023 at PT. Paiton Operation Maintenance Indonesia. Key findings include: the ambient temperature was 31 degrees C, the DC output voltage was a maximum of 180V, and the corrected chlorine concentration was 1748 mg/l, resulting in a chlorine production of 270.94 kg-Cl2/hr and 74.9% of theoretical Faraday efficiency. The test was prepared by Emha Ridwan Arrosyid and approved by Bambang Sarwoko of PT. Paiton Operation Maintenance Indonesia.
The document summarizes the results of a performance test of a sodium hypochlorite generator. The test was conducted on October 4, 2023 at PT. Paiton Operation Maintenance Indonesia. Key findings include: the ambient temperature was 31 degrees C, the DC output voltage was a maximum of 180V, and the corrected chlorine concentration was 1748 mg/l, resulting in a chlorine production of 270.94 kg-Cl2/hr and 74.9% of theoretical Faraday efficiency. The test was prepared by Emha Ridwan Arrosyid and approved by Bambang Sarwoko of PT. Paiton Operation Maintenance Indonesia.
SODIUM HYPOCHLORITE GENERATOR A PERFORMANCE TEST RECORD
Purchase Order No. : PO. 86379/PE/POMI/23 Tagging Number : CCL-GEN-510A
Project Name : REPLACE SODIUM HYPOCHLORITE CELL TRAIN A Date of Test : 04 October 2023 Owner/Client : PT. Paiton Operation Maintenance Indonesia Note : Tested by PT. Mandala Setia, conducted with HACH Contractor : PT. Mandala Setia Standard test procedure Ambient Temp. : 31 deg. C
Time Each Cell Voltage (V.) Supplied Corrected
DC Output Chlorine Chlorine Faraday DC Output AC electric Seawater Chlorine No. Load (%) Voltage Concent Production Production Current (Amp) Setting Sampling power (kW) 1 2 3 4 Flow Rate Concent ration (V.) ration (mg/l) (Kg-Cl₂/hr) (%) (m³/h) (mg/l) 7600,00 100% 1453,00 max. 180 45 45 45 45 155,00 1748,00 1748,00 270,94 74,9
Prepared by, Checked by, Approved by,
Emha Ridwan Arrosyid Bacharuddin Sapto Adi Bambang Sarwoko
PT. Mandala Setia PT. Mandala Setia PT. Paiton Operation Maintenance Indonesia Corrected Chlorine Concent ration (mg/l)
Rc = Oc-Ic+(Ax10)+(Bx2.2)
Rc : Corrected available chlorine concentration (mg/l)
Oc : Available chlorine concentration at electrolyzer outet (mg/l) Ic : Available chlorine concentration at electrolyzer inlet (mg/l) A : Ammonia nitrogen concentration at electrolyzer inet (mg/l) B : COD concentration at electrolyzer inlet (mg/l)