C-Plan type systems, valve on gravity HW return Switchmaster midi valve systems Drayton

Connections
The numbers printed at the tip of each arrow represent the Wiring Centre Controls All details as for Biflo except:
terminals to which those leads or terminals should be connected.
Room thermostat Cylinder thermostat 1. Remove link 13-14
2. Insert new link 5-14
Wiring Centre basic links
3. Connect valve as shown
LWC1 Wiring Centre
on right
Wiring guide
Wiring centres, designed to literature to hand, the
Cable clamps arrangement simplify wiring installations and
circuit checking, lose some of
elementary mains supply and
switch terminals or leads. The
Programmer
their value if they are not in result is a handy pocket-sized
themselves easy to understand wiring guide which does not
and use. The Drayton LWC1 suffer from superfluous detail
wiring centre has been and which makes the busy
Pump Boiler introduced to meet this installer's job that much easier.
requirement. Although Drayton are not
The LWC1 is suited to all consultants and cannot offer to
popular central heating and hot design systems, they will readily
water systems, with adequate provide advice on the use of the
Mains input Motorised valves
wiring space, terminals and cable LWC1 in any system not covered.
230v. 50HZ

Refer to boiler handbook for wiring details of pump overrun boilers. access points. Its use will save
the installer time and
Invensys Climate Controls Europe
uncertainty, both at the time of
Sales: +44 (0) 845 130 5522 installation or in any subsequent
Helpline: +44 (0) 845 130 7722 checking.
Email: customerservices@invensys.com This wiring guide covers, in a
CONFORMS TO THE ESSENTIAL REQUIREMENTS
superb easy-to-understand
OF THE FOLLOWING DIRECTIVES: manner, the main systems in NB: All wiring must be to latest
89/336/EEC – Electromagnetic compatibility
73/23/EEC – Low voltage Directive 5 016254 100088 popular use. It assumes that the I.E.E. standards and carried out
installer can identify from the by a competent, qualified
boiler, pump and controls installer.
090-675 Iss B
0803
Spring return 2-valve systems 22mm (twinzone, s-plan etc.) Mid-position spring return valve systems (biflo, flowshare, y-plan, etc.)
Connections Connections
The numbers printed at the tip of each arrow represent the Wiring Centre Controls The numbers printed at the tip of each arrow represent the Wiring Centre Controls
terminals to which those leads or terminals should be connected. terminals to which those leads or terminals should be connected.
Room thermostat Cylinder thermostat Room thermostat Cylinder thermostat

Wiring Centre basic links Wiring Centre basic links

Programmer Programmer

Pump Boiler Pump Boiler

Mains input Motorised valves Mains input Motorised valves


230v. 50HZ 230v. 50HZ

Refer to boiler handbook for wiring details of pump overrun boilers. ★
Refer to boiler handbook for wiring details of pump overrun boilers.