Coating Systems SP-1246 V.4 Protected

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 88

Product Cat Product Sub Cat Agent name Manufacturer

External coating for


uninsulated carbon/low
External coating as per SP-1246 No local Agent Hempel
alloy steel structures at
≤ 120oC

External coating for


uninsulated carbon/low
No local Agent Jotun
alloy steel structures at
≤ 120oC

External coating for


uninsulated carbon/low
External coating as per SP-1246 No local Agent Sigma
alloy steel structures at
≤ 120oC

External coating for


uninsulated carbon/low
External coating as per SP-1246 No local Agent Carboline
alloy steel structures at
≤ 120oC
External coating for
uninsulated carbon/low
External coating as per SP-1246 No local Agent SIPCO
alloy steel structures at
≤ 120oC

External coating for


uninsulated carbon/low
External coating as per SP-1246 No local Agent Berger
alloy steel structures at
≤ 120oC

External coating for


uninsulated carbon/low
External coating as per SP-1246 No local Agent International
alloy steel structures at
≤ 120oC

External coating for


uninsulated carbon/low
External coating as per SP-1247 No local Agent Kanat Paints
alloy steel structures at
≤ 120oC
Comments and Quality Alerts Country of Origin

system 1:
primer:Hempadur Primer 15300 (Min DFT 50 microns)
Intermediate coat: Hempadur Hi-build 45200 (Min DFT 100 microns)
Top coat: Hempathane Topcoat 55210 (Min DFT 50 microns)

system 2:
First coat: Hampadur Mastic 45880/1 (Min DFT 150 Microns)

Top coat: Hempathane HS 55610 (Min DFT 50 Microns)

System 1:
primer: Penguard Primer (Min DFT 50 microns)
Intermediate coat: Penguard HB (Min DFT100microns)
Top coat: Durathane (Min DFT 50 microns)

System 2:
Primer:Penguard express (Red) (Min DFT 75 micron)
Intermediate coat: Penguard express (Grey) (Min DFT 75 micron)
Top Coat: Hard top XP (Min DFT50 micron)

system 3:

First coat: Penguard express (Min DFT 150 micron)


Top Coat: Hard top XP (Min DFT50 micron)

system 1:
primer: Sigmacap primer EP 7680 (Min DFT 50 microns)
Intermediate coat: Sigmacap Coating EP 7682 (Min DFT 100 microns)
Top Coat: Sigmacap finish PU 7690 (Min DFT 50 microns)

system 2:
First coat: Sigmacover 410Y - 150 microns DFT

Top coat: Sigmadur 550Y – 50 microns DFT

system 1:
primer: Carboguard 893 (Min DFT 50 microns)
Intermediate coat: Carboguard 190HB (Min DFT 100 microns)
Top Coat: Carbothane 134(Min DFT 50 microns)

system 2:
First coat: Carboguard 890 (min 125 DFT)
Top Coat: Carbothane 134HP (min 75 DFT)
primer: Siprime 215 (Min DFT 50 microns )
Intermediate coat: Sipoxy Sheld 240 (Min DFT 100 Microns)
Top Coat: Sipthane 360 (Min DFT 50 Microne)

system 1:
- primer: Epilux 78 (Min DFT 50 Microns)
- Intermediate coat: Epilux 218 Hb (Min DFT 100 Microns)
- Top Coat: Luxethane 5000 (Min DFT 50 Microns)

system 2:
- First coat: Epimastic 7200 (Min DFT 150 micron)
- Top Coat: Luxethane 5000 (Min DFT 50 Microns)

system 1:
- Primer: Intergard 251 (Min DFT 50 Microns)
- Intermediate coat: Intergard 475 HS(Min DFT 100 Microns)
- Top Coat: Interthane 990SG (Min DFT 50 Microns)

System 2:
- First coat: Interseal 1052 (150 microns DFT)
- Top coat: Interthane 990SG (50 microns DFT)

First coat: 15550 KANEPOX MASTICOAT - 150 microns DFT

Top coat: 37850 KANPOLY ACR ENAMEL DTM – 50 microns DFT

Limitation in application in Summer time as per manufcaturer datasheet


as below:
-Maximum air tempertaure 35C
-Maximum surface temperature 45C
SRM contact

NO Seby Joseph [JOSE@hempel.com]

Ibrahim Al Sukry
NO
ibrahim.al.sukry@jotun.com

Chetan Kosambia
NO
[Chetan.k@sigmapaints.com]

Thomas Pinto
NO
[TPinto@stoncor-me.com]
NO

Anand Xavier
NO
[anand.xavier@asianpaints.com]

Nair, V. (Vinod)
NO
[Vinod.Nair@akzonobel.com]

NO Can KANAT <can@kanatboya.com.tr>


Product Cat Product Sub Cat Agent name Manufacturer

External coating for


uninsulated carbon/low
alloy steel structures
below ≤ 120°C
External coating as per SP-1246 No local Agent Hempel
For harsh atmospheric
environment; when
specified in MSR

External coating for


uninsulated carbon/low
alloy steel structures
below ≤ 120°C
External coating as per SP-1246 No local Agent Jotun
For harsh atmospheric
environment; when
specified in MSR

External coating for


uninsulated carbon/low
alloy steel structures
below ≤ 120°C
External coating as per SP-1246 No local Agent Sigma
For harsh atmospheric
environment; when
specified in MSR

External coating for


uninsulated carbon/low
alloy steel structures
below ≤ 120°C
External coating as per SP-1246 No local Agent Carboline
For harsh atmospheric
environment; when
specified in MSR

External coating for


uninsulated carbon/low
alloy steel structures
below ≤ 120°C
External coating as per SP-1246 No local Agent Berger
For harsh atmospheric
environment; when
specified in MSR
External coating for
uninsulated carbon/low
alloy steel structures
below ≤ 120°C
External coating as per SP-1246 No local Agent International
For harsh atmospheric
environment; when
specified in MSR

External coating for


uninsulated carbon/low
alloy steel structures
below ≤ 120°C
External coating as per SP-1246 No local Agent Humidur
For harsh atmospheric
environment; when
specified in MSR
Comments and Quality Alerts Country of Origin

1.Avantguard 750 - 60μm


2. Hempadur Mastic 45880/1 - 180μm
3. Hempathane HS 55610 - 60μm

1. Barrier; 60 micron.
2. Jotacote univ.; 160 micron
3. Hardtop XP; 60 micron

1. Sigmazinc 68SP; 60 micron.


2. Sigmaprime 200; 180 micron
3. Sigmadur 550; 60 micron

1. Carbozinc 858; 75 micron.


2. Carboguard 893; 160 micron
3. Carbothane 134 HG; 60 micron.

1. Zincanode 620; 70 micron.


2. Epimastic 4100; 160 micron.
3. Luxathane 5160; 70 micron
1. primer: Interzinc 52 (Min DFT 60 Microns)
2. Intermediate coat: Intergard 475HS (Min DFT 180 Microns)
3.Top Coat: Internthane 990SG (Min DFT 60 Microns)

Humidur FP, Min 400 micron DFT


SRM contact

NO Seby Joseph [JOSE@hempel.com]

Ibrahim Al Sukry
NO
ibrahim.al.sukry@jotun.com

Chetan Kosambia
NO
[Chetan.k@sigmapaints.com]

Thomas Pinto
NO
[TPinto@stoncor-me.com]

Anand Xavier
NO
[anand.xavier@asianpaints.com]
Nair, V. (Vinod)
NO
[Vinod.Nair@akzonobel.com]

Frederik Van Haute


NO
<Frederik.Van.Haute@acotec.be>
Product Sub Cat Agent name Manufacturer

External coating for


uninsulated carbon/low
External coating as per SP-1246 No local Agent Hempel
alloy steel structures
> 120 °C to 200 °C

External coating for


uninsulated carbon/low
External coating as per SP-1246 alloy steel structures No local Agent Jotun
> 120 °C to 200 °C
External coating for
uninsulated carbon/low
External coating as per SP-1246 alloy steel structures No local Agent Sigma
> 120 °C to 200 °C

External coating for


uninsulated carbon/low
External coating as per SP-1246 alloy steel structures No local Agent International
> 120 °C to 200 °C

External coating for


uninsulated carbon/low
External coating as per SP-1246 alloy steel structures No local Agent Berger
> 120 °C to 200 °C
Comments and Quality Alerts Country of Origin

system 1:
- primer: Hempel Gavosil 15700 Min DFT 75 microns
- Intermediate coat: Hempel Silicone Aluminium 56914 Min DFT 25
microns
- Top Coat: Hempel Silicone Aluminium 56914 Min DFT 25 microns

system 2:
2 layers of Hempadur 85671
Each layer 100 micron, TDFT 200 microns

system 1:
- first coat: Epoxy HR (DFT100 micron)
- Top coat: Epoxy HR (DFT 100 micron)

system 2:
- primer: Resist 86 AV Min DFT 75 microns
- Intermediate coat: Solvalitt Aluminium Min DFT 20 microns
Top coat : Solvalitt Aluminium Min DFT 20 microns

system 3:

2 layers of Jotatemp 250; Each 150 micron;


TDFT 300 micron DFT
system 1:
- first coat: Sigmatherm 230 Min DFT 100 microns
- Top coat: Sigmatherm 230 Min DFT 100 microns

system 2:
- primer: Sigma Zinc 158 Min DFT 75 microns
- Intermediate coat: Sigma therm 540 Min DFT 25 microns
- Top Coat: Sigma therm 540 Min DFT 25 microns

system 1:
- first coat: Interbond 2340UPC (min DFT 100 micron)
- Top coat: Interbond 2340UPC (min DFT 100 micron)

system 2:
- primer: Interzinc 22 (Min DFT 50 microns)
- Intermediate coat: Intertherm 50 (Min DFT 25 microns)
- Top Coat: Intertherm 50 (Min DFT 25 microns)

First Coat: Apcotherm EPN 200; DFT 125 micron.


Top Coat: Apcotherm EPN 200; DFT 125 micron.
TDFT : 250 micron.
SRM contact comments

NO Seby Joseph [JOSE@hempel.com]

Ibrahim Al Sukry
NO
ibrahim.al.sukry@jotun.com
Chetan Kosambia
NO
[Chetan.k@sigmapaints.com]

Nair, V. (Vinod)
NO
[Vinod.Nair@akzonobel.com]

Anand Xavier
[anand.xavier@asianpaints.com]
Product Cat Product Sub Cat Agent name Manufacturer

External coating for


uninsulated carbon/low
alloy steel structures
External coating as per SP-1246 No local Agent Hempel
>200 °C to 450 °C

External coating for


uninsulated carbon/low
alloy steel structures
External coating as per SP-1246 No local Agent Jotun
>200 °C to 450 °C

External coating for


uninsulated carbon/low
External coating as per SP-1246 alloy steel structures No local Agent Sigma

>200 °C to 450 °C

External coating for


uninsulated carbon/low
alloy steel structures
External coating as per SP-1246 No local Agent International
>200 °C to 450 °C
Comments and Quality Alerts Country of Origin SRM

system 1:
- primer: Hempel Gavosil 15700 Min DFT 60 microns
- Intermediate coat: Hempel Silicone Aluminium 56914 Min DFT 25
microns
NO
- Top Coat: Hempel Silicone Aluminium 56914 Min DFT 25 microns

system 1:
- primer: Resist 86 AV Min DFT 75 microns
- Intermediate coat: Solvalitt Aluminium Min DFT 20 microns
Top coat : Solvalitt Aluminium Min DFT 20 microns NO

system 1:
- primer: Sigma Zinc 158 Min DFT 75 microns
- Intermediate coat: Sigma therm 540 Min DFT 25 microns NO
- Top Coat: Sigma therm 540 Min DFT 25 microns

system 1:
- primer: Interzinc 22 (Min DFT 50 microns)
- Intermediate coat: Intertherm 50 (Min DFT 25 microns) NO
- Top Coat: Intertherm 50 (Min DFT 25 microns)
Approved up to 400 degC
contact commants

Seby Joseph [JOSE@hempel.com]

Ibrahim Al Sukry
ibrahim.al.sukry@jotun.com

Chetan Kosambia
[Chetan.k@sigmapaints.com]

Nair, V. (Vinod)
[Vinod.Nair@akzonobel.com]
Product Cat Product Sub Cat Agent name Manufacturer

Buried CS/SS plant piping, GULF


road crossing and Wadis PETROCHEMICA
External coating as per SP-1246 STOPAQ
L SERVICES &
TRADI

Buried CS/SS plant piping,


Ali Al Aufy
road crossing and Wadis Canusa-CPS
External coating as per SP-1246 Trading Co.
A shawcor company
L.L.C.

Buried CS/SS plant piping,


SAP & KAPS
road crossing and Wadis
External coating as per SP-1246 PETROLEUM Viscotaq
SERVICES LLC
Comments and Quality Alerts Country of Origin SRM
system 1:
STOPAQ WRAPPINGBAND CZH + Stopaq PVC Outerwrap Tape
Approved up to 65 degC
NO
system 2:
STOPAQ WRAPPINGBAND CZHT + STOPAQ OUTERWRAP HTPP
Approved up to 95 degC

Canusa Wrapid Bond™ (visco elastic) + Wrapid coat™ (outer layer)


NO
Approved for max operating temp up to 85 degC

VISCOTAQ HT as an Inner wrap with PE as outer wrap up to maximum


NO
operating temperature 60°C.
contact

Unni Krishnan
[sales@gpsoman.com]

Jorge Pinto [jpinto@alialaufy.com]

Alan D'Souza
[alan.dsouza@shawcor.com]

Ahmed Abdulrazek
<ahmed.abdulrazek@skps.com>
Product Cat Product Sub Cat Agent name Manufacturer

Buried CS/SS vessels,


plant piping, road
crossing and Wadis.
and external tank
External coating as per SP-1246 No local Agent Hempel
bottom (underside) in
contact with soil
>70 °C
CP is mandatory

Buried CS/SS vessels,


plant piping, road
crossing and Wadis.
and external tank
External coating as per SP-1246 No local Agent Goldschmidt
bottom (underside) in
contact with soil
>70 °C
CP is mandatory

Buried CS/SS vessels,


plant piping, road
crossing and Wadis.
and external tank
External coating as per SP-1246 No local Agent International
bottom (underside) in
contact with soil
>70 °C
CP is mandatory

Buried CS/SS vessels,


plant piping, road
crossing and Wadis.
and external tank
External coating as per SP-1246 No local Agent Berger
bottom (underside) in
contact with soil
>70 °C
CP is mandatory
Comments and Quality Alerts Country of Origin

Hempadur XP 87550 (Min DFT 1000 microns)

Approved for 110 degC only

Protegol EP130HT- 1000 MICRONS, (Min DFT 1000 Microns)

Approved for 130 degC only

Interzone 485 (Min DFT 1500 microns)


Approved up to 95 degC only

First layer:Apcodur EHB 500-500 microns DFT


Top layer: Apcodur EHB 500-500 microns DFT
TDFT: 1000 micron
Approved up to 95 degC only
SRM contact comments

NO Seby Joseph [JOSE@hempel.com]

NO Not available

Nair, V. (Vinod)
NO
[Vinod.Nair@akzonobel.com]

Anand Xavier
[anand.xavier@asianpaints.com]
Product Cat Product Sub Cat Agent name Manufacturer

Buried CS/SS vessels,


plant piping, road
crossing and Wadis.
and external tank
External coating as per SP-1246 bottom (underside) in No local Agent Hempel
contact with soil
Below and up to 70 °C
max.
CP is mandatory

Buried CS/SS vessels,


plant piping, road
crossing and Wadis.
and external tank
External coating as per SP-1246 bottom (underside) in No local Agent Jotun
contact with soil
Below and up to 70 °C
max.
CP is mandatory

Buried CS/SS vessels,


plant piping, road
crossing and Wadis.
and external tank
External coating as per SP-1246 bottom (underside) in No local Agent Berger
contact with soil
Below and up to 70 °C
max.
CP is mandatory

Buried CS/SS vessels,


plant piping, road
crossing and Wadis.
and external tank
External coating as per SP-1246 bottom (underside) in No local Agent sigma
contact with soil
Below and up to 70 °C
max.
CP is mandatory

Buried CS/SS vessels,


plant piping, road
crossing and Wadis.
and external tank
External coating as per SP-1246 bottom (underside) in No local Agent International
contact with soil
Below and up to 70 °C
max.
CP is mandatory
Comments and Quality Alerts Country of Origin

system 1:
Hempadur 85531 - one coat 600 microns

system 2:
Hempadur XP 87550 (500 micron)

JOTACOTE 113 one coat 500microns

Epilux 82 (2 layers: Each is 250 microns; TDFT 500 microns)

SigmaLine 2000 - one coat 500microns

Interzone 954 (2 layers: Each is 250 microns; TDFT 500 microns)


SRM contact comments

NO Seby Joseph [JOSE@hempel.com]

Ibrahim Al Sukry
NO
ibrahim.al.sukry@jotun.com

Anand Xavier
NO
[anand.xavier@asianpaints.com]

Chetan Kosambia
NO
[Chetan.k@sigmapaints.com]

Nair, V. (Vinod)
NO
[Vinod.Nair@akzonobel.com]
Product Cat Product Sub Cat Agent name Manufacturer

Tanks, Crude oil


storage tanks & water
Internal coating systems for
tanks Shell Shell Epikote System
carbon steels
≤ 60 °C

Tanks, Crude oil


storage tanks & water
Internal coating systems for
tanks No local Agent Carboline
carbon steels
≤ 60 °C

Tanks, Crude oil


storage tanks & water
Internal coating systems for
tanks No local Agent Jotun
carbon steels
≤ 60 °C

Tanks, Crude oil


storage tanks & water
Internal coating systems for
tanks No local Agent Akzonobel
carbon steels
≤ 60 °C
Comments and Quality Alerts Country of Origin SRM
Approved External Coating System:
- primer: To be specified by the contractor
- Intermediate coat: Epikote DX 816
NO
- Top Coat: Epikure 161

Min TDFT 3000 microns

Approved External Coating System:


- primer: Carboline 193
- Intermediate coat: Carboline 151-2
NO
- Top Coat: Carboline 151-2

Min TDFT 3000 microns

Approved External Coating System:


- primer: Penguard primer(35 micron)
- Intermediate coat: Chemtech GM clear (1200 micron)
NO
- Top Coat: Chemtech GM clear (1200 micron) + Chemtech GM
clear (400 micron)
Min TDFT 2835 microns based on qualification

Approved External Coating System:


- 1st Coat: Interline 982 (25 micron)
- 2nd Coat: Interline 9670 (1200 micron)
- 3rd Coat: Matt Interline 9670 (1200 micron) NO
- 4th Coat: Matt Interline 9670 (400 micron)
- 5th Coat: Veil Interline 925 (200 micron)
Min TDFT: 3025 microns
contact

not available

Thomas Pinto
[TPinto@stoncor-me.com]

Ibrahim Al Sukry
ibrahim.al.sukry@jotun.com

Nair, V. (Vinod)
[Vinod.Nair@akzonobel.com]
Product Cat Product Sub Cat Agent name Manufacturer

Tanks in
water/hydrocarbon
service ≤ 60 °C
Rest of tank above
Internal coating systems for
liquid level (PCS-7A) No local Agent Carboline
carbon steels
and interior of tank roof
where PCS-7A cannot
be applied

Tanks in
water/hydrocarbon
service ≤ 60 °C
Rest of tank above
Internal coating systems for
liquid level (PCS-7A) No local Agent Berger
carbon steels
and interior of tank roof
where PCS-7A cannot
be applied

Tanks in
water/hydrocarbon
service ≤ 60 °C
Rest of tank above
Internal coating systems for
liquid level (PCS-7A) No local Agent Sigma
carbon steels
and interior of tank roof
where PCS-7A cannot
be applied

Tanks in
water/hydrocarbon
service ≤ 60 °C
Rest of tank above
Internal coating systems for
liquid level (PCS-7A) No local Agent Jotun
carbon steels
and interior of tank roof
where PCS-7A cannot
be applied

Tanks in
water/hydrocarbon
service ≤ 60 °C
Rest of tank above
Internal coating systems for
liquid level (PCS-7A) No local Agent Hempel
carbon steels
and interior of tank roof
where PCS-7A cannot
be applied
Tanks in
water/hydrocarbon
service ≤ 60 °C
Rest of tank above
Internal coating systems for
liquid level (PCS-7A) No local Agent Akzonobel
carbon steels
and interior of tank roof
where PCS-7A cannot
be applied
Comments and Quality Alerts Country of Origin

- primer: Carboline193 (50 micron)


- Carboguard C703 (500 micron)

- primer: Epilux 610 (50 micron)


- Intermediate coat: Epilux 518 (225 micron)
- Top Coat: Epilux 518 (225 micron)

Phenguard 930 can be used as primer 50 micron if needed.


Novaguard 840 - 500 microns DFT

- First layer: Tank guard 412 (250 microns DFT)


- Top layer : Tank guard 412 (250 microns DFT)

System 1:
- primer: Hempadur 85671 at min 50 microns DFT
- Hempadur 35900 at min 450 microns DFT

System 2: (up to 3 bars operating pressure)


( Hempaline Defend 630, overall DFT 500 microns)
Interline 984 (Min 500 Microns DFT)
SRM contact

Thomas Pinto
NO
[TPinto@stoncor-me.com]

Anand Xavier
NO
[anand.xavier@asianpaints.com]

Chetan Kosambia
NO
[Chetan.k@sigmapaints.com]

Ibrahim Al Sukry
NO
ibrahim.al.sukry@jotun.com

NO Seby Joseph [JOSE@hempel.com]


Nair, V. (Vinod)
NO
[Vinod.Nair@akzonobel.com]
Product Cat Product Sub Cat Agent name Manufacturer

Vessels, Temperature
below ≤ 93 °C /
For Tanks in
Internal coating systems for water/hydrocarbon
No local Agent Carboline
carbon steels service if temperature >
60°C

In conjunction with CP

Vessels, Temperature
below ≤ 93 °C /
For Tanks in
Internal coating systems for water/hydrocarbon
No local Agent Hempel
carbon steels service if temperature >
60°C

In conjunction with CP

Vessels, Temperature
below ≤ 93 °C /
For Tanks in
Internal coating systems for water/hydrocarbon
No local Agent Berger
carbon steels service if temperature >
60°C

In conjunction with CP

Vessels, Temperature
below ≤ 93 °C /
For Tanks in
Advanced OilField
Internal coating systems for water/hydrocarbon
Technology Belzona
carbon steels service if temperature >
Company LLC
60°C

In conjunction with CP

Vessels, Temperature
below ≤ 93 °C /
For Tanks in
Internal coating systems for water/hydrocarbon
No local Agent Corrocoat UK
carbon steels service if temperature >
60°C

In conjunction with CP
Vessels, Temperature
below ≤ 93 °C /
For Tanks in
Internal coating systems for water/hydrocarbon
No local Agent International
carbon steels service if temperature >
60°C

In conjunction with CP

Vessels, Temperature
below ≤ 93 °C /
For Tanks in
Internal coating systems for water/hydrocarbon
No local Agent Jotun
carbon steels service if temperature >
60°C

In conjunction with CP
Comments and Quality Alerts Country of Origin SRM

First layer: Carbo glass 5301 (500 micron DFT)


NO
Top layer: Carbo glass 5301 (500 micron DFT)

NO
Hempel’s Vinyl Ester GF 35910 (formerly 359QA) TDFT 1500 Microns

First layer: Steelshield VE (450 micron)


Top layer: Steelshield VE (450 micron) NO

Belzona 1391- one coat 1000 microns DFT NO

Corrocoat Polyglass VEF 1500 microns DFT NO


NO
first layer: Interline 955 -750 microns DFT
top layer: Interline 955 -750 microns DFT
TDFT; 1500 microns

First layer: Chemflake Special 750 microns DFT


Top layer: Chemflake Special 750 microns DFT NO
contact COMMENTS

Thomas Pinto
[TPinto@stoncor-me.com]

Seby Joseph [JOSE@hempel.com]

Anand Xavier
[anand.xavier@asianpaints.com]

Yunus Maniyar
[yunus@aotcglobal.com]

Not available
Nair, V. (Vinod)
[Vinod.Nair@akzonobel.com]

Ibrahim Al Sukry
ibrahim.al.sukry@jotun.com
Product Cat Product Sub Cat Agent name Manufacturer

Vessels and Tanks in


hydrocarbon and water
Internal coating systems for
service If Temperature No local Agent Hempel
carbon steels
>93 °C

Vessels and Tanks in


hydrocarbon and water
Internal coating systems for
service If Temperature No local Agent Akzonobel
carbon steels
>93 °C
Comments and Quality Alerts Country of Origin SRM

First layer:Hempadur 85671 (100 micron)


Intermediate layer: Hempadur 85671 (100 micron)
Top layer: Hempadur 85671 (100micron)
NO
Approved for temp up to 95 degC in immersion service.

It can be applied in 2 coats each 150 microns; TDFT 300 microns (as per
latest manufacturer datasheet) and with written approval from Hempel

Enviroline 405 HTR (500 microns DFT)


up to 130 deg.C max. operating temperature and less than 30 bar design NO
pressure
contact Comments

Seby Joseph [JOSE@hempel.com]

Nair, V. (Vinod)
[Vinod.Nair@akzonobel.com]
Product Cat Product Sub Cat Agent name Manufacturer

Internal coating systems for


Potable Water Tanks No local Agent Hempel
carbon steels

Internal coating systems for


Potable Water Tanks No local Agent Berger
carbon steels

Internal coating systems for


Potable Water Tanks No local Agent Jotun
carbon steels

Internal coating systems for


Potable Water Tanks No local Agent Sigma
carbon steels

Internal coating systems for


Potable Water Tanks No local Agent Akzonobel
carbon steels

Internal coating systems for


Potable Water Tanks No local Agent Carboline
carbon steels
Comments and Quality Alerts Country of Origin
system1:
3 coat system of Hempadur 85671 100 +100+ 125 microns =
min 325 DFT (datsheet says up to 23°C only)
System 2:
Hempadur 35560; 2 layers each 200 microns DFT; TDFT is 400 microns

- primer: Epilux 610 T DFT 50 Microns


- Intermediate coat: Epilux155 Sf Min DFT 175 Microns
- Top Coat: Epilux 155 Sf Min DFT 175 Microns
TDFT= 400 microns DFT

First layer: Tank guard DW Min DFT 200 micron


Top layer: Tank guard DW Min DFT 200 micron
TDFT; 400 microns DFT

First layer: Sigmaprime 200; DFT 100 micron.


Second layer: Sigmaguard CSF 585; DFT 300 micron
TDFT = 400 microns DFT

Interline 975 Min DFT 500 microns DFT

first layer: Carboguard 891 VOC; 150 micron DFT.


Top layer: Carboguard 891 VOC; 175 micron DFT.
Min TDFT=325 microns
SRM contact

NO Seby Joseph [JOSE@hempel.com]

Anand Xavier
NO
[anand.xavier@asianpaints.com]

Ibrahim Al Sukry
NO
ibrahim.al.sukry@jotun.com

Chetan Kosambia
[Chetan.k@sigmapaints.com]

Nair, V. (Vinod)
NO
[Vinod.Nair@akzonobel.com]

Thomas Pinto
NO
[TPinto@stoncor-me.com]
Product Cat Product Sub Cat Agent name Manufacturer
Coating under
insulation for Carbon
Corrosion protection of under
steel and alloy steel
insulation carbon steel and No local Agent Hempel
surface in atmospheric
alloy steel surfaces
exposure
≤ 175 °C

Coating under
insulation for Carbon
Corrosion protection of under
steel and alloy steel
insulation carbon steel and No local Agent International
surface in atmospheric
alloy steel surfaces
exposure
≤ 175 °C

Coating under
insulation for Carbon
Corrosion protection of under
steel and alloy steel
insulation carbon steel and No local Agent Berger
surface in atmospheric
alloy steel surfaces
exposure
≤ 175 °C

Coating under
insulation for Carbon
Corrosion protection of under
steel and alloy steel
insulation carbon steel and No local Agent Sigma
surface in atmospheric
alloy steel surfaces
exposure
≤ 175 °C

Coating under
insulation for Carbon
Corrosion protection of under
steel and alloy steel
insulation carbon steel and No local Agent Jotun
surface in atmospheric
alloy steel surfaces
exposure
≤ 175 °C

Coating under
insulation for Carbon
Corrosion protection of under
steel and alloy steel
insulation carbon steel and No local Agent Carboline
surface in atmospheric
alloy steel surfaces
exposure
≤ 175 °C
Comments and Quality Alerts Country of Origin

Hempadur 85671 at 100 microns x 2 layers; TDFT 200 microns

system 1:
Intertherm 228HS, 100 micron DFT X 2 layrs; TDFT 200 microns
system 2:
Interbond 2340UPC, 100 micron DFT X 2 layers; TDFT 200 microns

First layer: Apcotherm EPN 200- 125 microns DFT


Top layer: Apcotherm EPN 200- 125 microns DFT
TDFT; 250 microns DFT

SIGMATHERM 230; 100 micron DFT X 2 layers; TDFT 200 microns

Epoxy HR 100 micron X 2 layers; TDFT 200 microns

Thermaline 450 EP; 100 micron DFT X 2 layers; TDFT 200 microns
SRM contact comments

NO Seby Joseph [JOSE@hempel.com]

Nair, V. (Vinod)
NO
[Vinod.Nair@akzonobel.com]

Anand Xavier
NO
[anand.xavier@asianpaints.com]

Chetan Kosambia
NO
[Chetan.k@sigmapaints.com]

Ibrahim Al Sukry
NO
ibrahim.al.sukry@jotun.com

Thomas Pinto
NO
[TPinto@stoncor-me.com]
Product Cat Product Sub Cat Agent name Manufacturer

Coating under insulation


for Carbon steel and alloy
steel surface
External coating as per SP-1246 No local Agent Hempel
>175 °C to 450 °C

Coating under insulation


for Carbon steel and alloy
External coating as per SP-1246 steel surface No local Agent Jotun
>175 °C to 450 °C

Coating under insulation


for Carbon steel and alloy
steel surface in
External coating as per SP-1246 No local Agent Sigma
atmospheric exposure
>175 °C to 450 °C

Coating under insulation


for Carbon steel and alloy
External coating as per SP-1246 steel surface No local Agent International
>175 °C to 450 °C
Comments and Quality Alerts Country of Origin SRM

Versiline CUI 56990 at 150 microns X 2 layers; TDFT 300 microns NO

JOTATEMP 650; 125 micron X 2 layers; TDFT 250 microns NO

NO
PPG HI-TEMP 1027, 100 micron DFT X 2 layers; TDFT=200 microns

NO
Interbond 1202 UPC 100 micron DFT X 2 layers; TDFT=200 micron
contact comments

Seby Joseph [JOSE@hempel.com]

Ibrahim Al Sukry
ibrahim.al.sukry@jotun.com

Chetan Kosambia
[Chetan.k@sigmapaints.com]

Nair, V. (Vinod)
[Vinod.Nair@akzonobel.com]
Product Cat Product Sub Cat Agent name Manufacturer

This system for field joint


coating of TSA coated
Corrosion protection of under
pipes (Only, when TSA
insulation carbon steel and alloy No local Agent International
cannot be applied after
steel surfaces
girth weld at site)

This system for field joint


coating of TSA coated
Corrosion protection of under
pipes (Only, when TSA
insulation carbon steel and alloy No local Agent Jotun
cannot be applied after
steel surfaces
girth weld at site)

This system for field joint


coating of TSA coated
Corrosion protection of under
pipes (Only, when TSA
insulation carbon steel and alloy No local Agent hempel
cannot be applied after
steel surfaces
girth weld at site)
Country of
Comments and Quality Alerts Origin SRM

System 1:
Interbond 1202 UPC 100 micron DFT X 2 layers; TDFT=200 microns
- Air curing, Interbond 1202UP (titanium modified inorganic
copolymer)– Touch Dry, 30 minutes, Hard dry 3 hours at 25°C
NO
System2: (Heat cured: Used Only if opertaing temperature is >200°C)
Intertherm 751 CSA 100 micron DFT X 2 layers; TDFT=200 microns
-Heat curing, Intertherm 751CSA(cold spray Aluminum) – Touch Dry, 60
minutes, Hard dry 8 hours at 25°C

- The minimum temperature / secondary curing time for Intertherm


751CSA is above 200°C.
Suitable for application over hot substrate up to 150°C

First layer: 125 microns DFT Jotatemp 1000 ceramic


Top layer: 125 mic rons DFT Jotatemp 1000 ceramic NO
TDFT: 250 microns DFT

Mist coat as a first layer (a thin coat of Versiline CUI 56990 on TSA before
applying the full system)
NO
Versiline CUI 56990 at 150 microns X 2 layers; TDFT 300 microns
contact commants

Compatability letter with TSA from


Akzonobel R&D.
Special attention shall be given at
the interface overlapping with TSA
Nair, V. (Vinod)
as per paint manufacturer
[Vinod.Nair@akzonobel.com]
guidelines and shall be supported
by adhesion test for overlapping
with TSA .

Compatability letter with TSA from


R&D jotun.
Special attention shall be given at
Ibrahim Al Sukry the interface overlapping with TSA
ibrahim.al.sukry@jotun.com as per paint manufacturer
guidelines; and shall be supported
by adhesion test for overlapping
with TSA

Compatability letter with the


confirmation from Hempel R&D
regarding the suitability to be
applied with overlapping areas of
TSA.
Seby Joseph [JOSE@hempel.com] Special attention shall be given at
the interface overlapping with TSA
as per paint manufacturer
guidelines and shall be supported
by adhesion test for overlapping
with TSA.
Product Cat Product Sub Cat Agent name Manufacturer

Coating under insulation


for Stainless steel
Corrosion protection of under
−35 °C up to 50 °C No local Agent International
insulation for Stainless steel

Coating under insulation


for Stainless steel
Corrosion protection of under
−35 °C up to 50 °C No local Agent Berger
insulation for Stainless steel
Comments and Quality Alerts Country of Origin SRM contact

system 1:
Intertherm 228HS, 100 micron DFT X 2
layers; TDFT 200 microns Nair, V. (Vinod)
NO
system 2: [Vinod.Nair@akzonobel.com]
Interbond 2340UPC, 100 micron DFT X 2
layers; TDFT 200 microns

First layer: Epilux 219; 100 microns DFT


Top layer: Epimastic 4100; 100 microns Anand Xavier
NO
DFT; TDFT=200 microns [anand.xavier@asianpaints.com]
commants
Product Cat Product Sub Cat Agent name Manufacturer

Coating under insulation


for Stainless steel
Corrosion protection of under
>50 °C to +175 °C No local Agent International
insulation for Stainless steel

Coating under insulation


for Stainless steel
Corrosion protection of under
>50 °C to +175 °C No local Agent Sigma
insulation for Stainless steel

Coating under insulation


for Stainless steel
Corrosion protection of under
>50 °C to +175 °C No local Agent Carboline
insulation for Stainless steel
Comments and Quality Alerts Country of Origin SRM contact

system 1:
Intertherm 228HS, 100 micron DFT X 2
layers; TDFT 200 microns Nair, V. (Vinod)
NO
system 2: [Vinod.Nair@akzonobel.com]
Interbond 2340UPC, 100 micron DFT X 2
layers; TDFT 200 microns

SIGMATHERM 230; 100 microns DFT X 2 Chetan Kosambia


NO
layers; TDFT 200 microns [Chetan.k@sigmapaints.com]

Thermaline 450 EP; 100 microns DFT X 2


Thomas Pinto
layers; TDFT 200 microns NO
[TPinto@stoncor-me.com]
commants
Product Cat Product Sub Cat Agent name Manufacturer

Coating under insulation


for Stainless steel
Corrosion protection of under
>175 °C to 450 °C No local Agent International
insulation for Stainless steel

Coating under insulation


for Stainless steel
Corrosion protection of under
>175 °C to 450 °C No local Agent Sigma
insulation for Stainless steel
Comments and Quality Alerts Country of Origin SRM contact

Interbond 1202 UPC 100 micron DFT X 2 Nair, V. (Vinod)


NO
layers; TDFT=200 microns [Vinod.Nair@akzonobel.com]

PPG HI-TEMP 1027, 100 micron DFT X 2


Chetan Kosambia
layers; TDFT=200 microns NO
[Chetan.k@sigmapaints.com]
commants
Product Cat Product Sub Cat Agent name Manufacturer

Atmospheric exposure
≤ 120 C
External coating systems for un
insulated stainless steels and No local Agent Hempel
Galvanised surfaces

Atmospheric exposure
≤ 120 C
External coating systems for un
insulated stainless steels and No local Agent Jotun
Galvanised surfaces

Atmospheric exposure
≤ 120 C
External coating systems for un
insulated stainless steels and No local Agent Sigma
Galvanised surfaces
Atmospheric exposure
≤ 120 C
External coating systems for un
insulated stainless steels and No local Agent Berger
Galvanised surfaces

Atmospheric exposure
≤ 120 C
External coating systems for un
insulated stainless steels and No local Agent International
Galvanised surfaces

Atmospheric exposure
≤ 120 C
External coating systems for un
insulated stainless steels and No local Agent Sigma
Galvanised surfaces

Atmospheric exposure
≤ 120 C
External coating systems for un
insulated stainless steels and No local Agent Carboline
Galvanised surfaces
Comments and Quality Alerts Country of Origin SRM

- First layer: Hempadur mastic 45880/1 Min DFT 150 microns NO


- Top layer: Hempathane topcoat 55610 Min DFT 50 microns
approved up to 120 degC

45880 is fast curing recommended during Winter

System 1:
First layer: Jotacote Univ 150 microns DFT
NO
Top layer:Hardtop XP 50 microns DFT
System 2:
First layer: Penguard Universal 125 microns DFT
Top layer: Hardtrop XP 75 microns DFT

First layer: SIGMAPRIME 200; 150 microns DFT


Top layer: SIGMADUR 550; 50 microns DFT NO
NO
First layer: Epilux 219; 150 microns DFT
Top layer: Luxathane 5160; 50 microns DFT

First layer: Interseal 670HS; 150 microns DFT

Top layer: Interthame 990; 50 microns DFT NO

First layer: Sigmaprime 200; 150 microns DFT


Top layer: Sigmadur 550; 50 microns DFT

First layer: Carboguard 890; 125 microns DFT


Top layer: Carbothane 134 HP; 75 microns DFT
contact commants

Seby Joseph [JOSE@hempel.com]

Ibrahim Al Sukry
ibrahim.al.sukry@jotun.com

Chetan Kosambia
[Chetan.k@sigmapaints.com]
Anand Xavier
[anand.xavier@asianpaints.com]

Nair, V. (Vinod)
[Vinod.Nair@akzonobel.com]

Chetan Kosambia
[Chetan.k@sigmapaints.com]

Thomas Pinto
[TPinto@stoncor-me.com]
Product Cat Product Sub Cat Agent name Manufacturer

Atmospheric exposure
>120 °C to 200 °C

External coating system for un


No local Agent Hempel
insulated stainless steels

Atmospheric exposure
>120 °C to 200 °C

External coating system for un


No local Agent Jotun
insulated stainless steels

Atmospheric exposure
>120 °C to 200 °C

External coating system for un


No local Agent International
insulated stainless steels

Atmospheric exposure
>120 °C to 200 °C

External coating system for un


No local Agent carboline
insulated stainless steels

Atmospheric exposure
>120 °C to 200 °C

External coating system for un


No local Agent Sigma
insulated stainless steels

Atmospheric exposure
>120 °C to 200 °C

External coating system for un


No local Agent Berger
insulated stainless steels
Comments and Quality Alerts Country of Origin SRM

Hempadur 85671; 100 microns X 2 layers; TDFT 200 microns NO

Epoxy HR; 100 microns X 2 layers; TDFT 200 microns NO

Intertherm 228HS; 100 microns X 2 layers; TDFT 200 microns NO

NO
Thermaline 450 EP; 100 microns X 2 layers; TDFT 200 microns

SigmaTherm 230; 100 microns X 2 layers; TDFT 200 microns

Apcotherm EPN 200; 100 microns X 2 layers; TDFT 200 microns


contact COMMENT

Seby Joseph [JOSE@hempel.com]

Ibrahim Al Sukry
ibrahim.al.sukry@jotun.com

Nair, V. (Vinod)
[Vinod.Nair@akzonobel.com]

Thomas Pinto
[TPinto@stoncor-me.com]

Chetan Kosambia
[Chetan.k@sigmapaints.com]

Anand Xavier
[anand.xavier@asianpaints.com]
Product Cat Product Sub Cat Agent name Manufacturer

Atmospheric exposure
External coating system for un
>200 °C to 450 °C No local Agent HEMPEL
insulated stainless steels

Atmospheric exposure
External coating system for un
>200 °C to 450 °C No local Agent Jotun
insulated stainless steels

Atmospheric exposure
External coating system for un
>200 °C to 450 °C No local Agent International
insulated stainless steels

Atmospheric exposure
External coating system for un
>200 °C to 450 °C No local Agent Sigma
insulated stainless steels
Comments and Quality Alerts Country of Origin SRM

Silicone Aluminium 56914; 25 microns X 2 layers; TDFT 50 microns NO


Or
Versiline CUI 56990; 150 microns X 2 layers; TDFT 300 microns

-Solvalitt; 20 microns X 2 layers; TDFT 40 microns


NO
Or
JOTATEMP 650; 125 microns X 2 layers; TDFT 250 microns

Intertherm 50; 25 microns X 2 layers; TDFT 50 microns


NO
Or
Interbond 1202 UPC; 100 microns X 2 layers; TDFT=200 microns

SigmaTherm 540; 30 microns X 2 layers; TDFT 60 microns


Or
PPG HI-TEMP 1027, 100 microns X 2 layers; TDFT 200 microns
contact COMMENT

Seby Joseph [JOSE@hempel.com]

Ibrahim Al Sukry
ibrahim.al.sukry@jotun.com

Nair, V. (Vinod)
[Vinod.Nair@akzonobel.com]

Chetan Kosambia
[Chetan.k@sigmapaints.com]
Product Cat Product Sub Cat Agent name Manufacturer

Buried CS well casing Buried CS well casing No local Agent International

Buried CS well casing Buried CS well casing No local Agent

Buried CS well casing Buried CS well casing No local Agent Tuboscope


Comments and Quality Alerts Country of Origin SRM

Interzone 485 coating NO

Flint Coating (SOS) NO

TUBO-WRAP NO
contact

Kamyani, Ibrahim UWCM2


<Ibrahim.ISK.Kamyani@pdo.co.om>

Kamyani, Ibrahim UWCM2


<Ibrahim.ISK.Kamyani@pdo.co.om>
Kamyani, Ibrahim UWCM2
<Ibrahim.ISK.Kamyani@pdo.co.om>

You might also like