1) Product overview
Noble-metal catalyst (HNXT-068A) uses Pt and Pd as the active components and
cordierite honeycomb ceramics as the carrier, a small amount of rare earth materials were
added through special process to make the catalyst structure more stable, the surface active
coating has stronger adhesion and is not easy to fall off. Noble-metal catalyst
(HNXT-CAT-V01) has excellent catalytic performance, low ignition temperature, high
purification efficiency, and good temperature resistance, suitable for conventional VOCs gas
treatment, benzene treatment effect is good, and can be widely used in CO and RCO devices.
2) Product picture
Page 1 of 4
3) Product parameter
Dealing with VOCs Alcohols, ketones, esters, ethers, aldehydes, alkane, benzene and
other conventional VOCs
Page 2 of 4
4) Conventional VOCs T50 and T98 conversion temperature
5) Remark
- The waste gas shall not contain sulfur, phosphorus, arsenic, lead, mercury, halogens (fluorine,
chlorine, bromine, iodine, astatine), heavy metals, resins, high-boiling point, high-viscosity
polymers and other toxic chemical elements or substances.
- Before entering VOCs gas, it is necessary to enter flowing fresh air to fully preheat the
catalyst (preheat to 240℃~350℃, set according to the highest temperature required by the
most difficult gas in the exhaust gas component).
- The catalyst should be handled gently, and the direction of the catalyst hole should be
consistent with the direction of the air flow when filling, and placed closely, without gaps.
- The optimal operating temperature of the catalyst is 250~500 ℃ , the exhaust gas
concentration is 500~4000mg/m3, and GHSV is 10000~20000h-1. It should be avoided as
far as possible to avoid the sudden increase of exhaust gas concentration or the long-term
high temperature of catalyst above 600℃.
- The dust content of exhaust gas should not be exceed 10mg/m3, otherwise it is easy to
cause the blockage of catalyst channel. If it is difficult to reduce the dust to the ideal state
Page 3 of 4
before treatment, it is recommended to regularly remove the catalyst and blow it with an air
gun before use, without washing it with water or any liquid.
- At the end of the operation, firstly cut off the VOCs gas source, use fresh air to continue
heating for 20 minutes and then shut down the catalytic combustion equipment. Avoiding
catalyst in low temperature contact with VOCs gas, can effectively prolong the service life of
catalyst.
- When the catalyst is used for a long time, there is a certain decrease in activity, the catalytic
bed can be switched before and after or up and down, or the operating temperature of the
catalytic chamber can be appropriately increased.
- When the temperature of the catalytic furnace is higher than 450℃, it is recommended to
start the supplementary cooling fan and fill cold air to cool the catalytic furnace to protect
the catalyst.
- The catalyst should be moisture proof, do not soak or rinse with water.