PosiChek3™

Test your SCBA performance


with the industry standard,
from Honeywell Analytics
PosiChek3

Features and Benefits PosiChek3 is the industry standard NFPA-


Full Readiness Testing compliant SCBA test equipment, with
• Face piece leak check
• Exhalation check valve
enhanced precision high pressure
opening pressure transducer and sound detection system.
• Static face piece pressure
• Bypass flow rate
PosiChek3’s computerized SCBA test Easy And Automatic Testing
• Pressure gauge accuracy
bench has been the industry standard PosiChek3 has taken automation a
• Low pressure alarm activation
for thousands of fire departments, step further, making it even easier to
• Visual inspection
refineries, chemical plants and nuclear use than before. All PosiChek3 units are
• First stage regulator
power stations worldwide since it was equipped with an Enhanced Precision
performance
first introduced in 1988. Since then, High Pressure Transducer that
• Breathing resistance at
there have been a number of upgrades provides more precise measurement
standard (40 LPM) work rate
to keep pace with increasingly rigorous of pressure within the high-pressure
• Breathing resistance at
testing criteria. manifold. Upgrades are also available.
maximum (100 LPM) work rate
In addition, a Sound Detection System
The Industry’s leading NFPA- (SDS) automates the primary audible
Simplified Recording Compliant SCBA Test Bench alarm test, eliminating human error. As
• PosiChek3 uses your own Firefighters and other first responders always, PosiChek3 offers a full range of
Windows-compatible PC or can only work as well as the equipment test and data storage options, making
laptop to run tests and they use. That’s why NFPA 1852 record keeping a breeze.
store results. mandates that all compliant SCBA
• Results can be printed or be tested on a calibrated breathing
stored for retrieval in a user- machine before being put into service,
specified database. and at least once per year thereafter.
PosiChek3 is the only test bench that
Test Software Compatibility meets stringent NFPA standards.
• Windows XP or Vista PosiChek3 can fully evaluate the
• Pentium 4 processor 2.0 GHz operational readiness of an SCBA in
or higher with 512 MB RAM less than 2 minutes, and consumes
• A minimum of 50 MB of less than 1% of its air supply.
available space on hard drive
• Parallel port
• CD-ROM Drive

Find out more Contact Honeywell Analytics: Asia Pacific


www.honeywellanalytics.com Honeywell Analytics, Asia Pacific
Americas #508, Kolon Science Valley (1)
Technical Services Honeywell Analytics, Inc. 187-10 Guro-Dong, Guro-Gu
ha.service@honeywell.com 405 Barclay Blvd. Seoul, 152-050
Lincolnshire, IL 60069 Korea
www.honeywell.com USA Tel: +82 (0)2.2025.0307
Tel: 847.955.8200 Fax: +82 (0)2.2025.0329
Toll-free: 800.538.0363 analytics.ap@honeywell.com
Fax: 847.955.8210
detectgas@honeywell.com
Please Note:
While every effort has been made to ensure accuracy in this publication, no Sperian’s Biosystems is now part of Honeywell Analytics. As we begin to fully
responsibility can be accepted for errors or omissions. Data may change, as integrate our companies, you might notice some small changes. This integration
well as legislation, and you are strongly advised to obtain copies of the most is about bringing together two of the best in gas detection. We are focused on
recently issued regulations, standards, and guidelines. This publication is not putting our customers first and making the right decisions to guarantee Honeywell
intended to form the basis of a contract. Analytics continues to remain the experts in gas detection.
DS01150_v1 6/12
© 2012 Honeywell Analytics

You might also like