Professional Documents
Culture Documents
DSRV Report 84655 20191211213001
DSRV Report 84655 20191211213001
DSRV Report 84655 20191211213001
/home/hitrax/log/dsrvReports/dsrv_report_84655_20191211213001.txt
---------------------------------------------------------------------
Number of procedure errors: 0
---------------------------------------------------------------------
GENERAL 12/11/2019 21:29:39
---------------------------------------------------------------------
KEYBOARD STATUS 12/11/2019 21:29:39
Keyboard status OK
---------------------------------------------------------------------
HARDWARE 12/11/2019 21:29:39
---------------------------------------------------------------------
LIGHT BARRIER 12/11/2019 21:29:39
---------------------------------------------------------------------
POWER SUPPLY 12/11/2019 21:29:39
PI Version 3
Voltages 1: pi voltage 11.98 V
2: lif voltage 5.91 V
---------------------------------------------------------------------
LINE SCOPE 12/11/2019 21:29:39
---------------------------------------------------------------------
DETECTOR LINES 12/11/2019 21:29:39
---------------------------------------------------------------------
XRAY GENERATOR 12/11/2019 21:29:39
---------------------------------------------------------------------
STATISTICS 12/11/2019 21:29:39
---------------------------------------------------------------------
LINE INTERFACE 12/11/2019 21:29:39
LIF 0 - status OK
LIF 0 - lin slot 0
LIF 0 - lex slot 0
LIF 0 - # detectors 2304
---------------------------------------------------------------------
CALIBRATION DATA 12/11/2019 21:29:39
Calibration data
cal threat lut: semtex.lut,
{4095/4095, 3233/3072, 2019/1746, 1258/0999},
{2737/2057, 2162/1570, 1353/0919, 0848/0540},
{1974/0801, 1572/0624, 0996/0382, 0630/0233}
cal hard lut: hard.lut,
{4095/4095, 2737/2057, 1974/0801}
---------------------------------------------------------------------
I/O CONTROL 12/11/2019 21:29:39
IOC state OK
Config state OK
External default config ENABLED
External config DISABLED
Custom config DISABLED
---------------------------------------------------------------------
TEMPERATURES 12/11/2019 21:29:39
Internal 0 C
External 0 C
---------------------------------------------------------------------
UPS 12/11/2019 21:29:39
UPS Installed NO
---------------------------------------------------------------------
RADIOACTIVITY DETECTOR SUBSYSTEM 12/11/2019 21:29:39
Installed NO
D I A G N O S T I C R E P O R T E N D
---------------------------------------------------------------------