Control Panels

VISTA-128BPT SERIES
VISTA® Partitioned Commercial Burglary Alarm
Control Panels
The VISTA-128BPT is a powerful member of the Honeywell Home family of
commercial alarm panels, integrating burglary, CCTV and access control
functions. Many features are available that extend the applications of the
VISTA-128BPT while simplifying end-user operation.

The VISTA-128BPT and VISTA-128BPTSIA are listed for residential burglary,


residential fire and commercial burglary applications (see agency listings
in this document for more details). They are compatible with a wide range
of AlarmNet communications products for alarm reporting, uploading /
downloading and remote services.

F E AT U R E S A N D B E N E F I T S

Standard features • S
 upports up to 16 compatible two-wire • Quick exit
(VISTA-128BPT and VISTA-128BPTSIA): smoke detectors on zone 1
• Group bypass
• Z
 one 7 may be used for keyswitch
• Provides nine style-B hardwired zones • Arm faulted
arming/disarming
• S
 upports up to 119 additional zones • Event arming
• I ntegrates with WIN-PAK ® access
using a built-in polling (V-Plex ®, • C
 arbon monoxide (CO) zone type
control systems to provide increased
multiplex) loop interface support
users, event log and scheduling
• S
 upports up to 127 wireless zones using • E
 xpanded high-speed RS-232
• S
 upports V-Plex addressable VISTAKEY
up to two 5800 series wireless receivers capability for third party interface
access control (up to eight doors and
(fewer if using hardwire and automation
250 cards)
and/or polling loop zones)
• E
 asily programmed and maintained by • I nternet upload/download over
• P
 rovides one power-limited bell circuit AlarmNet GSM and/or IP
Compass Windows-based downloader
delivering 1.7Amp (max) at 12VDC communicators over the panel’s keypad
• S
 upports up to 96 programmable
• P
 rovides the ability to control eight (ECP) bus
outputs
separate partitions independently, • R
 ingback support for AlarmNet
each functioning as if it had its own • P
 rogrammable to meet SIA false alarm
communicators (confirmation of
separate control prevention specifications. To meet UL
closing report)
approval for ANSI/SIA CP-01-2010,
• A
 ccommodates 150 user codes with • 2
 4-hour dialer test support for
order part number V128BPTSIA
seven authority levels AlarmNet devices
• S
 upports up to six touchscreen
• A
 ccommodates 32 keypad macro • S
 upports V-Plex Smart Contact feature
Advanced User Interface (AUI) devices
commands per system for improved responsiveness on
(6272 or later)
• Keeps a log of up to 512 events systems with many V-Plex zones
• Smoke detector reset at keypad
• Telco line cut detection
VISTA-128BPT SERIES Additional Features
BASIC HARDWIRED ZONES WIRELESS EXPANSION EIGHT PARTITIONS
Provides nine style-B hardwired zones Supports up to 127 wireless zones using Provides the ability to control eight
with the following characteristics: up to two 5800 Series wireless receivers separate areas independently, each
• EOLR supervision (optional for zones (fewer if using hardwire and/or polling functioning as if it had its own separate
2-8) supporting N.O. or N.C. sensors loop zones). control. Partitioning features include:
(EOLR supervision required for fire and Wireless zones have the following • A Common Lobby partition (1-8),
UL burglary installations) characteristics: which can be programmed to arm
• Individually assignable to one of • Supervised by control panel for automatically when the last partition
eight partitions check-in signals (except certain non- that shares the common lobby is
supervised transmitters) armed, and to disarm when the first
• Up to 16 two-wire smoke detectors
partition that shares the common lobby
on zone 1 • Tamper protection for supervised
is disarmed
• Four-wire smoke or heat detectors transmitters
• A Master partition (9), used strictly
on zones 1-8 (power to four-wire smoke • Individually assignable to one of
to assign keypads for the purpose of
detectors must be supervised with an eight partitions
viewing the status of all eight partitions
EOL device). Listed for residential
SCHEDULING at the same time (master keypads)
fire only.
Provides the following scheduling • All zones assignable to one of
POLLING LOOP EXPANSION capabilities: eight partitions
Supports up to 119 additional zones • Open/close schedules (for control of • Keypads assignable to one of eight
using a built-in polling (V-Plex, multiplex) arming/disarming and reporting) partitions or to Master partition 9 to
loop interface. Current draw can total up view system status
• Holiday schedules (allows different
to 128mA. Polling loop zones have the
time windows for open/close • Ability to assign relays to one or all
following characteristics:
schedules) eight partitions
• Must use V-Plex devices
• Timed events (for activation of relays, • Ability to display fire and/or burglary
• Supervised by control panel auto-bypassing and unbypassing, and panic and/or trouble conditions at
• Individually assignable to one of auto-arming and disarming, etc.) all other partitions’ keypads (selectable
eight partitions option)
• Access schedules (for limiting system
• Supports VSI Module access to users by time) • Individually programmable account
number, entry delay and exit delay
• Supports 4297 Expander Module • End user output programming mode
by partition
• Maximum wiring distance = (provides 20 timers for output control)
12,000 feet

V-Plex Loop

5193
4101SN DT7500SN FG1625SN Glassbreak 4208EX Eight-zone 4293SN Adapters Series Smoke Detectors
Relay Module V-Plex DUAL TEC V-Plex Expander and
Motion Sensor 4208SN Serialized Eight-
zone Remote Point Module 5881
ECP Bus Wireless
Receiver

6160
Console
710
Strobe
Light VISTA-128BPT
4204
Notification Relay
Appliances Keyswitch Module
Option
4146

Serial Printer PC Connection Phone Line to Central Station


748
Horn
RS-232

NOTE: Please refer to the website (security.honeywellhome.com/hsc) for the latest product information.
VISTA-128BPT SERIES Accessories
AUXILIARY DEVICES PASSIVE INFRARED DETECTORS • 5827BD - Bidirectional Keypad
• 4204 - Relay Module, four form • IS2500SN • 5853 - Glassbreak Detector
C contacts
• DT7500SN • 5898 - Wireless DUAL TEC
• 5881 Series - RF Receiver supporting Motion Sensor
V-Plex (Addressable) Contacts
5800 wireless detectors
• 4939SN-WH • 5800PIR-OD - Outdoor Motion Sensor
• 6160 - Alpha Keypad/Annunciator
• 4944SN-WH • 5870API - Asset Protection Device
• 6220S - System Printer
• 4959SN • 5800PIR/5800PIR-RES/5800PIR-COM
Manual Pull Stations - Wireless Motion Detectors
V-Plex Glassbreak Detectors
• 5140MPS-1 • 5800CO (5800COA - Canada) -
• FG1625SN
• 5140MPS-2 Wireless Carbon Monoxide Detector
VISTA Interactive Phone Module
V-Plex (addressable) Devices • 5800RP - Wireless Repeater
• 4286 VIP Module
• 4101SN Single Relay/Zone Module • 5808W3 (5808W3A - Canada) -
Optional Communicators Wireless Smoke Detector
• 4190SN Remote Point Module -
two zones • AlarmNet Internet/Intranet • 5809 - Wireless Heat Detector
communicators and digital cellular
• 4193SN Two-zone Serial Interface COMMERCIAL LISTED
communicators
Module WIRELESS DEVICES
• 4208EX - Eight-zone expander for ULC ACCESS CONTROL • 5817CB - Commercial UL Burglary,
commercial installations • VISTAKEY V-Plex (addressable) Universal Contact Monitoring
Access Control Transmitter*
• 4208SN Loop Expansion Module -
eight zones • VISTAKEY-SK Starter Kit • 5869 - Commercial UL Wireless
Hold-up Button*
• 4209U Group Zoning Module - two/ • VISTAKEY-EX Expansion Kit
four zones • 5881ENHC and 5883H Receivers
Wireless Devices
• 4293SN One-zone Serial *When used with 5881ENHC and/or
• 5804 - Wireless Key
Interface Module 5883H receiver.
• 5804BD - Bidirectional Key
• 4297 Isolation/Extender Module
• 5804BDV - Bidirectional Key
• VSI Short/Overload Isolation Module
with voice
• 5193SD
• 5816 - Door/Window Transmitter
• 5193SDT
• 5819 - Shock Sensor

4193SN 4190SN 4959SN


IS2500SN 4208U Two-zone Serial Interface Remote Point Overhead Door 4944SN
V-Plex PIR Eight-zone Module Module Contact Contact
Motion Sensor Expansion Module VISTAKEY
5808W3
5881ENHC (5808W3A - Canada) Glassbreak Detectors V-Plex
Commercial Wireless Wireless Access Control
ECP Bus Receiver Smoke Detector 5800
Module
(Max Two) Series
Wireless 5800PIR Series
6160 5816 Devices Wireless PIRs
Console Door/Window
Transmitter 4209U
Group Zoning
Module
5869
Commercial UL Supports Up To
Wireless Hold-up  5817CB Universal 16 Conventional
4204 Two-Wire
Relay Button Contact Monitoring Smoke Detectors
Module Transmitter
VISTA-128BPT SERIES Technical Specifications
AGENCY LISTED TO THE ELECTRICAL • Standby Time: Four hours min. with
FOLLOWING STANDARDS: • Voltage Input: From Honeywell 750mA aux. load using 7AH battery
• UL609 Grade A Local Mercantile Home No. 1361 Plug-In Transformer • Circuit Protectors: PTC circuit breakers
Premises and Mercantile Safe or 1361X10 transformer (for X-10 are used on battery input to protect
and Vault installations) rated 16.5VAC, 40 VA against reverse battery connections
• UL1610 Grades A, AA • Use 1361CN plug-in transformer for and on alarm sounder output to protect
Central Station Canada against wiring faults (shorts). A solid
state circuit breaker is used on auxiliary
• UL365 Grades A, AA Police Connect • Alarm Sounder Output:
power output to protect against wiring
• UL985 Household Fire 10VDC-13.8VDC, 1.7 amps max.,
faults (shorts).
(UL1023, UL609 installations);
•U
 L1023 Household Burglar Alarm
750mA less aux. current draw (UL985 MAIN DIALER
California State Fire Marshall (CSFM)
installations)
•U
 L1635 - Digital Alarm Communicator • Formats Supported: ADEMCO Contact
• Auxiliary Power Output: 9.6VDC- ID with support for four-digit and ten-
System Units
13.8VDC, 750mA max. For UL digit accounts and ADEMCO 4 + 2
• CAN/ULC - S303 installations, the accessories Express
• CAN/ULC - S304 connected to the output must be UL
• Line Seize: Double Pole
• CAN/ULC - S545 Listed, and rated to operate in the
above voltage range • Ringer Equivalence: 0.7B
• CAN/ULC - S1023
• Backup Battery: 12VDC, 4AH or 7AH CABINET DIMENSIONS
• For commercial burglary attack sealed-lead acid. YUASA NP4-12
proof requirements, use N5873V4BE 12-1/2" W X 14 1/2" H X 3" D
(12V, 4AH) or NP7-12 (12V, 7AH)
attack proof enclosure provided in recommended
VISTA-ULKT kit

ORDERING
VISTA-128BPT Commercial Burglary Alarm Control Panel (UL Listed)
V128BPTSIA SIA Approved Enhanced Commercial Burglary Alarm Control Panel (UL Listed)
V128BPTCNKT VISTA-128BPT Commercial Burglary Alarm Control Panel with 1361CN Transformer (Canada only)

For more information


security.honeywellhome.com

Resideo Technologies, Inc.


2 Corporate Center Drive, Suite 100 L/VSTA128BPTD/D | 08/19
© 2019 Resideo Technologies, Inc.
P.O. Box 9040 This product is manufactured
Melville, NY 11747 by Resideo and its affiliates. The
Honeywell Home trademark is
1-800-645-7492 used under license from Honeywell
resideo.com International Inc. All rights reserved.

You might also like