CAHO Microprocessor Controller Instruction Manual ooooe CEEER” | AIL Id _ i ® ) 088 i To I, Panel Description Code name Description PV Display: process value sv Display: setting value Cl Led: light on when output 1 action C2 Led: light on when output 2 action Al Led: light on when alarm 1 or time-signal action A2 Led: light on when alarm 2 or time-end action AT Led: light on when auto-tuning to start MA Led: light on when manual to start Key: change mode or enter y: changing set value Key: changing the value Key: shift Level Description ( Table 6 ) Character Description _ [Setting range] unit] initial Note Su.2 _| The 2nd pattern setting | LOLT-HILT cr ]o To select and make purchase for this function AE PID auot-tuning YES/NO NO P=0 failure Level 1] ALSP | Alarm 1 setpoint HILT-LOLT “olt | 10 (usER)| AZSP | Alarm 2 setpoint HILT-LOLT cr] o @ | OVUEL | Output indication 0%~100% % Press Ssees to become output in hand| OUEE | Time of output in hand 00.00~99.59 [HMM] 0. Tt appears when output is in hand] Pp The 1* proportional band | 0.0~200.0 % 3.0 P=0, the action becomes on/ot i ‘The I" integral time 03600 SEC [240 | P=0 10 conceal d | The I differential time | 0-900 sec_| 60 P=0 to conceal Level 2] CE__[ The Moye time 0-100 sec 110 FO coneal Relay ow, SOR eg (ew) |_£- P| The 2" proportional band_| 0.1~200.0 % 3.0 To selret and make purchase © C- CE | The 2* cycle time 0~100 SEC_] 10 Relay10 sees , SSR 2 secs HYSE | hysteresis (0-50%FS or [a It appears when P= 0 Pres ST db | Dead Bana ~50%-50%FS [or | o Atul | Auto-tuning in advance wr] o P=0 to conceal PuoF | Process value offset ‘cit | 0. SPoF_| Set value offset ~50%-50% cir fo Tt appears when the action on/of| LoLt! | Function Lock 0001111 0000 | See table 1 EYPE | Type mode TKTEBRSNCL| TP-K_| See table 2 Unie [anit “CIEIENG c dP__| Decimal point oven/00.000.00.000 0000) Lo.L& | Setpoint lowest limiter | LO.LT~HILT cr] O Hy. LE | Setpoint highest limiter [LOLT-HiT [corr | 400 Fil _| Filter setting 0.0-100.0 3.0 ACE | Control action HEAT/COOL HERE Level 3/77 FY | Alarm 1 mode setting -4-0 (OPHON 2 FU Alarm 2 mode setting none @ O-AISP ori o (O-A2SP or [1 , CH-{ |The 1” curent output highest setting] 0~S00 500 Itappears when CT=0 Press SELL [he curent output fowestseting] 0500 0 Ttappears when CT=0 CH=c_| The? caren ouput highest seting| 0-500 300___| Tt appears when C-CT-0 CL =e | The?” curent ouput lowest setting 0 Ttappears when C-CT=0 TES. H [transmition highest setting 500 [To select and make purchase TES. L | tansmition lowest setting 0 To select and make purchase AdeS [address 1-255 1 To select and make purchase bAUG [Baud rate feaooissouso0.92k| BPS [9600 _ | To select and make purchase FUnC | Operation function lock | 0000~1111 0000, Correct by original factory 2 PARAMETER PROCESS e ' —» PV Press@) for Ssecs Press QB for Ssecs 1@ 4 sv 1 1 Sue : p : A2HY a ‘a EYPE Jet ,@etaie@ (ij @.a Ae Unle i ,;@ta oe ,@ra@ ¢. ,@eta”" AISP 1,@t(a@ oP Je! Aikh ce ,@ra 2. tera @ ta lot 2 CHT e: ooP.. ,@t fesP {@ tea || Ota acs Aeka.: eC-Ce Hele pee eta |@ta |@ra!®@ ‘ “HYSE. Fle tS.H oUel : + @'a oUkt L | Press @® for 10 secs Enter if controller got the optional function. SP-IL 1/10) ete 1etaje'a l@ta;eta }@ta,o'ta 1@taleta 1@1a;e'a 1@ tai @ta ;@1a/eta SP-3L fetal eta Noted :1. It is unique setting parameter inside of dotted line. 2. ALSP becomes AtEm ; ACSP becomes A2EA when Al. FU or A2.FU be set to Time model. 3. Al or A2 light on / off alterrately when Time were counted. want to adjust Time that "Time" must be not counted and PV < SV 4. A 1A at press ED will show remainder time when time were counted. 5. There are two way to re-start Time when Time finished actions: 1.SetA LEA to 0000 then re-set new time. 2. Turn off power then re-start. xPV < SV The dispaly shows "End " of steps. to indicate finished when SP>H 1 LE , Please set from final pattern if want to release or set. Press 9) for 10 secs to enter Setting of program auto-tuning | oe gotthe function (Table 4 ) Character Description Setting range SP.IL 1" Auto-tuning set value LOLt~SP.2L P-l "Pp 0.1~200 i-] at 1~3600 d-} im) 1~900 SP.2L 2" Auto-tuning set value SP.1L~SP.3L P-2 2™P 0.1~200 l-2 2" 1~3600 d-2 2"D 1~900 SP.3L 3" Auto-tuning set value SP.2L~SP.4L P-3 3"P 0.1~200 1-3 31 1~3600 d-3 3"D 1~900 SP.YL 4" Auto-tuning set value SP.3L~SP.SL P-4 4°P 0.1~200 1-4 4°T 1~3600 a-4 4"°D 1~900 SP.5L 5" Auto-tuning set value SP.4L~SP.6L P-5 s°P 0.1~200 1-5 s"1 1~3600 Jd-5 S"D 1~900 SP.6L 6" Auto-tuning set value SP.SL~HILT P-6 oP 0.1~200 1-6 ol 1~3600 J-6 oD 1~900 Note: When SP>H+LE then the other auto-tuning set is disable 5 AlFu A2FU Alarm mode ( Table 3 ) (Characer Description Description nonE | Notfitted 1] ---C | Process alarm (high limit) TiSP = 2| 3--- | Process alarm (low limit) = AISP. 3] -4-C | Deviation alarm (high limit) rt 4| 3-+- | Deviation alarm (low limit) —— 5| 3--€ | Band alarm (outside) 6| -€J3-_ | Band alarm (inside) aise sy ohisp 7| ---E | Same 1 but 1° time will not on + 8| 3--- | Same 2 but 1” time will not on a 9| -4-E | Same 3 but 1" time will not on hee 10} Z-#- | Same 4 but 1" time will not on = Sviatse M1] F--E | Same 5 but 1" time will not on =o 12] -E3-_ | Same 6 but 1" time will not on -Aish_sy_*AISP on.-E | Same 7 but on be latch Isr. 3-.07 | Same 8 but on be latch < The PROG function of program controller only (Table 1) t¥PE Mode INPUT Character c Fr J tP-d 0~1000 32~1832 K EP- 0~1300 32~2372 T EP-E -199~400 -199~752 E tP-E 0~850 32~1562 B tP-b 0~1800 32~3272 R bP-r 0~1600 32~2912 s tP-S 0~1600 32~2912 N tP-n 0~1300 32~2372 c eP-C 0~1800 32~3272 RTD(DIN) d-PE -199~850 -199~1562 RTDGJIS) J-PE -199~600 -199~1112 Linear LinE -1999~9999 -1999~9999 ( Table 2 ) Unusual code description yuu Input Signal >H1. LE over 5% AtEEr Auto-tuning failue cause :time too long nanan Input Signal < Lo.LE under 59% oPEn Input do not connect or open CSEr Memory Broken Unique function 1. Output in manual + Time control , Set GULL press @ 5 secs then MA light on/off alternately. Adjust the input value is by manual. in this time. It will return auto after OUE.E's finished. % After setting "Output in manual " , Turn on power the output in manual firstly until release output in manual or UE.t's time is up. There is a way to release output in manual is setting set oUE.L press @ for 5 secs then MA light don't on and return auto contral. example | oUt P K- oUEE PID auot-tuning (Time) ae VEL 30% Lee oUEE unit HH.mm turn on power firstly Time 3X Set CT=0 , the faction with SSR of SCR or DC toAC the current will be limited. 2. SV2 could start by external connected (options) example 2 PV sv2 sv - | Alea | — Time % Could set 2 segment of temperature with A LEA 9 3. Design 6 PID auto-tuning function example 3 SP.6L spt SS | sv [<7 HALE SP.2L SPL ey | a0t-t00 | 201-300 >€ Detail parameter see table 4 . press @S 10 secs to enter 4. One controller control many others. (Mater and pupil called also) One could change other controllers's SV. 5. 3rd level parameter that 4~20mA output correct. The electric current output when set CH-/ (span correct). To increase the value to ada to output. To decrease the value to reduce output. [L-/ (zero correct) the same above method. Retransmisson correct the same above method Parameter "-&5.H " span correct Retransmisson correct the same above method Parameter " rE5.L " zero correct

You might also like