ELECTRICAL DATA SHEET

AC GENERATOR
H-XN-081101 & H-XN-081201

PAGE 1 OF 4

0 09/06/11 ISSUED FOR DESIGN AR APS MRS AS / PCK


A 10/05/11 ISSUED FOR REVIEW AR APS MRS AS / PCK IN SALAH GAS SOUTHERN FIELDS DEVELOPMENT PROJECT
CLIENT
REV DATE DESCRIPTION PRPD CKD APPD APPD APPD PIUL JOB NO : JI-2008 JI-2008 ISG JOB NO : 100045/ISG/CON
AREA: IN SALAH

SUB AREA : IS CPF


PREFIX DOC ISSUE DISC/DOC SYS SEQ TR REV
DRAWING TYPE : DATA SHEET DOC
NO ASSET SOURCE TYPE NO NO IDENTIFIER NO
DESCRIPTION :
AC GENERATOR
HB09 P NNFE 081 0501 0
H-XN-081101 & H-XN-081201
ELECTRICAL DATA SHEET AC GENERATOR H-XN-081101 & H-XN-081201

1 APPLICABLE TO PROPOSAL PURCHASE l AS BUILT


2 FOR ISG MANUFACTURER
3 SITE IN SALAH SERIAL NO.
4 SERVICE MAIN GENERATION NO. REQUIRED TWO
PURCHASER'S DATA

5 Design Output (MW) (NOTE 1) Max/Min 2.52 MW @ 45 ºC Primary Coolant AIR


6 Rated Power Factor (cos Phi) 0.8 Secondary Coolant AIR
7 Service Voltage (V) 5500 Cooling Classification CACA
8 Rated Frequency (Hz) 50 Cooling Temperature - Max + 55 ºC
9 No. of Phases 3 - Min + 1 ºC
10 Duty Type S1 Area Classififcation NOTE 2
11 Generator Neutral Earthing NOTE 3A Generator Enclosure Classification INDUSTRIAL
12 Earth Fault Current (A) 50A Generator Ingress protection IP 54 in Enclosure
13 Neutral Earth Resistor Rating (A,secs) 50A / 10 SECS Current Transformers NOTE 3B
14 Generator Excitation BRUSHLESS - In Phase : Line End YES
15 Direct Axis Sub-Transient Reactance (%) STA - In Phase : Neutral End YES
16 Direct Axis Transient Reactance (%) STA - In Neutral Connection YES
17 Parallel Operation YES Insulation Class F
18 Unbalanced Load YES Temperature Rise Class B
19 Surge Over Voltage Protection YES Vibration Detection YES
20 Main Terminals - Cable YES 0 Winding Temp. Detection YES
21 - Cable Size 2 x 3C x 240 mm2 Bearing Temp. Detection YES
22 - Cable Type XLPE/PVC/SWA/PVC Mounting FOOT
23 Neutral Terminals - Cable Size 1C x 240 mm2 Space Heater Voltage 400 / 230V AC
24 - Cable Type XLPE/PVC/AWA/PVC Environmental Conditions NOTE 2
25 NOTES
26 NOTE 1 : - AC GENERATORS SHALL BE CONTINUOUSLY RATED (S1 / IEC 60034) FOR THE MAXIMUM POTENTIAL POWER DEVELOPED BY THE GAS TURBINE DRIVER
0
27 WHEN OPERATING AT THE MINIMUM SITE AMBIENT TEMPERATURE AND DESIGNED TO FUNCTION SAFELY AT THE EXTREME AMBIENT OF 55°C.
28 NOTE 2 : - REFER TO GAS TURBINE DATASHEET (HB09-P-MUFM-081-0518) FOR SITE CONDITIONS, UTILITIES, AREA CLASSIFICATION, NOISE LIMITS AND GENERAL REQUIREMENTS.
29 NOTE 3A : - NEUTRAL EARTHING RESISTOR BY GENERATOR SUPPLIER ( REFER TO SKETCH ON PAGE 4)
30 NOTE 3B : - FOR CT DETAILS REFER TO SINGLE LINE DIAGRAM HB00-P-NNDO-081-1002 / 1003.
31 NOTE 4 : - SUPPLIER TO ADVISE
32 NOTE 5 : - REFER TO GENERATOR SPECIFICATION No. UU00-P-NNSG-000-0512 FOR FULL DETAILS .
33 NOTE 6 : - ROGOWSKI COIL TO BE SUPPLIED AND FITTED WITH ACCESS TO TERMINALS FOR 'ONLINE' INSULATION CHECK
34 NOTE 7 : - ALL OUTDOOR ELECTRICAL EQUIPMENT SHALL BE ATEX CERTIFIED FOR ZONE 2, IIB, T3 AS A MINIMUM.
SUPPLIER'S DATA

35 Generator Generator Parameters (All)


36 Type Positive Sequence Resistance (R1) %, Tol ± %, + 15%
37 Frame Designation Zero Sequence Resistance (R0) %, Tol ± %, + 15%
38 Degree of Protection Negative Sequence Resistance (R2) %, Tol ± %, + 15%
39 Synchronous Speed rpm 1500 Zero Sequence Reactance (X0) %, Tol ± %, + 15%
40 1st Critical Speed rpm Negative Sequence Reactance (X2) %, Tol ± %, + 15%
41 Direction of Rotation seen Towards Drive CW / CCW Direct Axis Synchronous Reactance (Xd) %, Tol ± unsat/sat / +15 %
42 Rated Voltage V 5500 Direct Axis Transient Reactance (X’d) %, Tol ± unsat/sat / +15 %
43 Rated Frequency Hz 50 Direct Axis Sub-Transient Reactance (X’’d) %, Tol ± unsat/sat / +15 %
44 Rated Output at 40 ºC base kVA MW Short Circuit Ratio
45 Rated Output at DE Side Max Power 10 ºC MW Generator Parameters (>1MVA only)
46 Power Factor cos Phi 0.8 Quadrature Axis Synchronous Reactance (Xq) %, Tol ± unsat/sat / +15 %
47 Duty Type Quadrature Axis Transient Reactance (X’q) %, Tol ± N/A
48 Rated Current A Quadrature Axis Sub-Transient Reactance (X’’q) %, Tol ± unsat/sat / +15 %
49 Thermal Rating Direct Axis O.C. Transient Time Constant (T’do) secs
50 Max. Allowable Neg. Phase Seq. Current % Direct Axis S.C. Transient Time Constant (T’ds) secs
51 Max. Allowable Content of Overharmonics % Direct Axis O.C. Sub-Transient Time Constant (T’’do) secs
52 Efficiency - 100% base kVA % Direct Axis S.C. Sub-Transient Time Constant (T’’ds) secs
53 - 75% base kVA % Quad. Axis O.C. Transient Time Constant (T’qo) secs N/A
54 - 50% base kVA % Quad. Axis S.C. Transient Time Constant (T’qs) secs N/A
55 Field Current No Load A Quad. Axis O.C. Transient Time Constant (T’’qo) secs
56 Field Current Full Load A Quad. Axis S.C. Transient Time Constant (T’’qs) secs
57 Insulation Class - Stator / Rotor Potier Reactance (Xp) %, Tol ± %, + 15%
58 Temperature Rise Class - Stator / Rotor Damping Factor
59 Overload Capability %, hrs Saturation Factor
60 Overload Capability %, secs Basic Impulse Level kV
61 Sustained Short Circuit %, secs Dimensions & Weights
62 Moment of Inertia Rotor kg m2 Overall Dimensions - LxWxH (in meters)
63 Cooling Method Weight of Machine kg
64 Cooling Water Flow Rate m3/h N/A Weight of Stator kg
65 Cooling Water Design Pressure Barg N/A Weight of Heat Exhanger - (Dry) kg
66 Leak Detection System N/A Weight of Coolant kg N/A
67 REMARKS:
68
69
70
71

EQUIPMENT TAG NO. H-XN-081101 & H-XN-081201 DOCUMENT NO. HB09-P-NNFE-081-0501


ELECTRICAL DATASHEET AC
DESCRIPTION REVISION 0 PAGE 2 OF 4
GENERATOR
ELECTRICAL DATA SHEET AC GENERATOR H-XN-081101 & H-XN-081201

SUPPLIER'S DATA

1 System Response Bearings


2 Voltage Constant Speed Radial - Drive End Sleeve Diameter
3 - Load Change from 50 To 0% %, secs Radial - Non Drive End Sleeve Diameter
4 - Load Change from 100 To 50% %, secs Thrust Bearing N/A
5 - Load Change from 0 To 50% %, secs Bearing Vibration Detector Type / Manufacturer 3300 / Bently Nevada
6 - Load Change from 50 To 100% %, secs Number in Each Bearing 2
7 Frequency Response: Bearing Temperature Detector Type PT100, 4 WIRE
8 - Sudden Load Change From 50 To 0% %, secs Number In Each Bearing 1
9 - Sudden Load Change From 100 To 50% %, secs Method of Bearing Lubrication Forced
10 - Sudden Load Change From 0 To 50% %, secs Lubrication Oil Flow Rate m3/h
11 - Sudden Load Change From 50 To 100% %, secs Lubrication Oil Pressure Barg
12 Exciter Windings
13 Type Stator Connection Y
14 Full Load Current (45°C) A Number of Stator Winding Terminals 12
15 Full Load Voltage V Winding Temperature Detector Type PT100, 4 WIRE
16 Ceiling Current (45°C) A Number In Each Phase 2
17 Ceiling Voltage V Heater Ratings
18 Nominal Exciter Response ratio 1/S Alternator kW
19 Current at Alternator base kVA A Exciter kW
20 Insulation Class Stator / Rotor F/F Aux. Cooling Fans
21 Temp. Rise Class Stator / Rotor B/B Rating kW
22 AVR Manufacturer
23 Model No. Frame Design
24 Manufacturer Number Off
25 Range of No Load Adjustment +10% Duty %
26 Steady State Accuracy % 0.5 Neutral Earthing Resistor
27 AVR Data (>1MVA only) Type
28 Forward Gain (KA) Resistance Ohms
29 Feedback Gain (KF) Resistor Rating A, secs
30 Regulator Amplifier Time Constant (TA) secs Degree of Protection IP 54
31 Regulator Feedback Time Constant (TF1) secs
32 Maximum Regulator Output (VR MAX)
33 Minimum Regulator Output (VR MIN)
34 Max. Rate of Change of Reg. Output (VR MAX)
35 Input Filter Time Constant (TR) secs
36 Exciter Gain (KE)
37 Exciter Time Constant (TE) secs
38 Exciter Output (E MAX)
39 Exciter Output (E MIN)
40 Exciter Saturation at 75% E MAX (SE75)
41 Exciter Saturation at 100% E MAX (SE100)
42 IEEE Model Type
43 Regulator Feedback Time Constant (TF2) secs
44 REMARKS:
45
46 STA – SUPPLIER TO ADVISE
47 N/A – NOT APPLICABLE
48 SUPPLIER SHALL ADVISE THE MACHINE OUTPUT AT +1 AND 55 ºC.
49 REMOTE CONTROL AND MONITORING SHALL BE IMPLEMENTED BY SERIAL LINK THROUGH MODBUS TCP/IP COMMUNICATION PROTOCOL.
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72

EQUIPMENT TAG NO. H-XN-081101 & H-XN-081201 DOCUMENT NO. HB09-P-NNFE-081-0501

ELECTRICAL DATASHEET AC
DESCRIPTION REVISION 0 PAGE 3 OF 4
GENERATOR
ELECTRICAL DATA SHEET AC GENERATOR H-XN-081101 & H-XN-081201
SYSTEM DATA

CB 1/2

NC

CB1 CB2

SWITCHGEAR

FIELD

G G

N.E.R. N.E.R.
50 A 50 A
10 SECS 10 SECS

1 REMARKS:
2 1) THE REGULATION CAPABILITY OF THE MAIN A.C. GENERATOR AND AVR SYSTEM UNDER STEADY STATE AND TRANSIENT
3 CONDITIONS SHALL BE VOLTAGE REGULATION GRADE 2.33 (VR2.33) AS DEFINED IN BS 4999 PART 140.
4 TRANSIENT PERFORMANCE IS DEFINED WITH RATED kVA AT 0.8 POWER FACTOR.
5
6 2) THIS DATA SHEET IS FOR TWO GENERATORS - TO BE CONNECTED TO THE H-EJ-081001, 5.5kV SWITCHBOARD.
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

EQUIPMENT TAG NO. H-XN-081101 & H-XN-081201 DOCUMENT NO. HB09-P-NNFE-081-0501


ELECTRICAL DATASHEET AC
DESCRIPTION REVISION 0 PAGE 4 OF 4
GENERATOR