This document outlines building permit requirements and types of construction. It discusses how building permits are issued and their validity periods. It also establishes four types of construction based on materials used - Type I is wood, Type II adds fire-resistant materials, Type III allows masonry and wood, and Types IV and V require non-combustible materials. It specifies fire resistance rating requirements for walls, floors, frames and openings that vary based on the type of construction.
This document outlines building permit requirements and types of construction. It discusses how building permits are issued and their validity periods. It also establishes four types of construction based on materials used - Type I is wood, Type II adds fire-resistant materials, Type III allows masonry and wood, and Types IV and V require non-combustible materials. It specifies fire resistance rating requirements for walls, floors, frames and openings that vary based on the type of construction.
This document outlines building permit requirements and types of construction. It discusses how building permits are issued and their validity periods. It also establishes four types of construction based on materials used - Type I is wood, Type II adds fire-resistant materials, Type III allows masonry and wood, and Types IV and V require non-combustible materials. It specifies fire resistance rating requirements for walls, floors, frames and openings that vary based on the type of construction.
⚫ Electronics hundred twenty (120) days. ⚫ Fire Safety Requirements Section 306. Non-issuance, Suspension or Section 304. Issuance of Building Permit Revocation of Building Permits ⚫ Building Official shall within fifteen (15) days from payment of the required Section 307. Appeal fees by the applicant, issue the ⚫ Within fifteen (15) days from the date building permit applied for. of receipt of advice of the non- ⚫ may issue a permit for the issuance, suspension or revocation of construction of only a part or portion permits of a building/structure ⚫ Ground Preparation and Excavation Section 308. Inspection and Supervision of Permit even while the building permit Work application is still being processed Section 309. Certificate of Occupancy *For excavations more than 50.00 cu. meters and more than 2 meters in depth a cash bond of P50,000 for the first 50 cu.m RULE 4 - TYPES OF CONSTRUCTION *P300 for every cu.m in excess of 50 cu.m until the building permit is issued, said Section 401. Types of Construction excavations shall not exceed 100.00 cu. ⚫ Type I - shall be of wood construction meters or 3.00 meters in depth and shall ⚫ Type II - wood construction with not be left open without any work being protective fire-resistant materials and done in the site for more than (120) days. one-hour fire resistive throughout, ⚫ Terms & Conditions of Permits except, that permanent non-bearing -That under Article 1723 of the Civil Code of partitions may use fire-retardant the Philippines, the engineer or architect treated wood within the framing who drew up the plans and specifications assembly with one-hour resistivity. for a building/structure is liable for damages ⚫ Type III - masonry and wood if within fifteen (15) years from the construction completion of the building/structure, the ⚫ Type IV - shall be steel, iron, concrete, same should collapse due to defect in the or masonry construction and walls, plans or specifications or defects in the ceiling and permanent partitions shall ground. be of incombustible fire-resistive construction, except, that permanent Section 305. Validity of Building Permits non-bearing partitions of one-hour ⚫ A building permit issued under the fire-resistive construction may use provisions of the Code shall expire and fire-retardant treated wood within the become null and void if the building or framing assembly. work authorized therein is not ⚫ Type V -four-hour fire-resistive commenced within a period of one (1) throughout and the structural year after the issuance of the building elements shall be of steel, iron, permit, or is suspended or abandoned concrete, or masonry construction. Section 402. Changes in Types to materials which are less than 1.00 ⚫ No change shall be made in the type millimeter in thickness cemented to the of construction of any building which surface of walls or ceilings would place the building in a different -Materials required to be flame-spread sub- type or type of construction proofed shall be treated with a flame- unless such building is made to comply retardant having a flame-spread of fifty (50) or less as determined by the “Tunnel Test” Section 403. Requirements on Type of ⚫ Standards for materials use in Construction structural framework, exterior walls ⚫ Fire Resistive Requirements and openings, floors, exits, stairs & -Exterior bearing and non-bearing walls of roofs shall be governed by the Types II and III Constructions shall have 1 pertinent provision of the Fire Code of hour fire-resistive rating the Philippines -Types IV and V shall have 4 hour fire- resistive rating -Interior bearing walls, permanent partitions, floors, and roofs of Types II, III and IV Construction shall have 1 hour fire-resistive rating. -Type V shall have 3 hour fire-resistive rating for bearing walls and one-hour fire-resistive rating for vertical openings, floors and roofs -Structural frames of Types II and III Construction shall have 1 hour fire-resistive rating -Type IV shall have 2 hour fire-resistive rating and those of Type V shall have 3 hour fire-resistive rating -Exterior doors and windows shall have one hour fire-resistive rating for all Types ⚫ Interior Wall and Ceiling Finishes -Finishes for interior walls and ceilings of any building shall be classified according to their flame-spread characteristic -smoke density shall not be greater than that obtained from burning of untreated wood under similar conditions when tested in accordance with the “Tunnel Test” -products of combustion shall be no more toxic than the burning of untreated wood under similar conditions -Requirements for flame-spread characteristics of finishes shall not apply to frames and trim of doors and windows and