⚫ Sanitary at any time after it has been

⚫ Plumbing commenced for a period of one


⚫ Electronics hundred twenty (120) days.
⚫ Fire Safety Requirements
Section 306. Non-issuance, Suspension or
Section 304. Issuance of Building Permit Revocation of Building Permits
⚫ Building Official shall within fifteen (15)
days from payment of the required Section 307. Appeal
fees by the applicant, issue the ⚫ Within fifteen (15) days from the date
building permit applied for. of receipt of advice of the non-
⚫ may issue a permit for the issuance, suspension or revocation of
construction of only a part or portion permits
of a building/structure
⚫ Ground Preparation and Excavation Section 308. Inspection and Supervision of
Permit even while the building permit Work
application is still being processed Section 309. Certificate of Occupancy
*For excavations more than 50.00 cu.
meters and more than 2 meters in depth a
cash bond of P50,000 for the first 50 cu.m RULE 4 - TYPES OF CONSTRUCTION
*P300 for every cu.m in excess of 50 cu.m
until the building permit is issued, said Section 401. Types of Construction
excavations shall not exceed 100.00 cu. ⚫ Type I - shall be of wood construction
meters or 3.00 meters in depth and shall ⚫ Type II - wood construction with
not be left open without any work being protective fire-resistant materials and
done in the site for more than (120) days. one-hour fire resistive throughout,
⚫ Terms & Conditions of Permits except, that permanent non-bearing
-That under Article 1723 of the Civil Code of partitions may use fire-retardant
the Philippines, the engineer or architect treated wood within the framing
who drew up the plans and specifications assembly with one-hour resistivity.
for a building/structure is liable for damages ⚫ Type III - masonry and wood
if within fifteen (15) years from the construction
completion of the building/structure, the ⚫ Type IV - shall be steel, iron, concrete,
same should collapse due to defect in the or masonry construction and walls,
plans or specifications or defects in the ceiling and permanent partitions shall
ground. be of incombustible fire-resistive
construction, except, that permanent
Section 305. Validity of Building Permits non-bearing partitions of one-hour
⚫ A building permit issued under the fire-resistive construction may use
provisions of the Code shall expire and fire-retardant treated wood within the
become null and void if the building or framing assembly.
work authorized therein is not ⚫ Type V -four-hour fire-resistive
commenced within a period of one (1) throughout and the structural
year after the issuance of the building elements shall be of steel, iron,
permit, or is suspended or abandoned concrete, or masonry construction.
Section 402. Changes in Types to materials which are less than 1.00
⚫ No change shall be made in the type millimeter in thickness cemented to the
of construction of any building which surface of walls or ceilings
would place the building in a different -Materials required to be flame-spread
sub- type or type of construction proofed shall be treated with a flame-
unless such building is made to comply retardant having a flame-spread of fifty (50)
or less as determined by the “Tunnel Test”
Section 403. Requirements on Type of ⚫ Standards for materials use in
Construction structural framework, exterior walls
⚫ Fire Resistive Requirements and openings, floors, exits, stairs &
-Exterior bearing and non-bearing walls of roofs shall be governed by the
Types II and III Constructions shall have 1 pertinent provision of the Fire Code of
hour fire-resistive rating the Philippines
-Types IV and V shall have 4 hour fire-
resistive rating
-Interior bearing walls, permanent partitions,
floors, and roofs of Types II, III and IV
Construction shall have 1 hour fire-resistive
rating.
-Type V shall have 3 hour fire-resistive rating
for bearing walls and one-hour fire-resistive
rating for vertical openings, floors and roofs
-Structural frames of Types II and III
Construction shall have 1 hour fire-resistive
rating
-Type IV shall have 2 hour fire-resistive
rating and those of Type V shall have 3 hour
fire-resistive rating
-Exterior doors and windows shall have one
hour fire-resistive rating for all Types
⚫ Interior Wall and Ceiling Finishes
-Finishes for interior walls and ceilings of
any building shall be classified according to
their flame-spread characteristic
-smoke density shall not be greater than
that obtained from burning of untreated
wood under similar conditions when tested
in accordance with the “Tunnel Test”
-products of combustion shall be no more
toxic than the burning of untreated wood
under similar conditions
-Requirements for flame-spread
characteristics of finishes shall not apply to
frames and trim of doors and windows and