Flowsensor

WP- for hot water up to 130 ºC


DN 40 ... DN 300
Dynamic

Special Features Application

Patented hydrodynamically balanced rotor Measurement of high, relativley constant flow rates

Patented symmetrical calibration adjustment

Hermetically sealed register (IP 68)


Pattern Approval
Register may be rotated through 360º

High overload capability


22.16 Nominal Diameter DN 50 ... 150
Pattern approved removable measuring element
Marking:
Up to 3 pulsers (1 x OD, 2 x RD) may be fitted without 96.01
Metrological class B
breaking the approval seal

Powder coating ensures maximum corrosion protection

Flowsensors Pressure rate PN 40 please see


separate leaflet

UK & Ireland Enquiries International Enquiries


Sensus Metering Systems Sensus Metering Systems GmbH Ludwigshafen
11 The Quadrangle, Abbey Park, Industriestrasse 16,
Romsey, Hampshire SO51 9DL UK 67063 Ludwigshafen Germany
T: +44 (0) 1794 526100 T: +49 (0) 621-6904-0
F: +44 (0) 1794 526101 F: +49 (0) 621-6904-1409
Email: info.gb@sensus.com Email: info.int@sensus.com

www.sensus.com www.sensus.com

L B 4100 INT • Page 1 / 4


Installation

horizontal Installation Requirements


Pipe vertical
inclined - Unrestricted straight pipe in front of the meter 3 x DN
- No abrupt restrictions directly behind the meter
upwards
Meter head
sideways

Technical Data

Performance data WP-Dynamic 130 ºC


Nominal Diameter DN 40 50 65 80 100 125 150 200 250 300
Size of meter (acc. to PTB-A22) Qn 10 15 25 40 60 100 150 250 400 600
Qmax maximum peak flow
once lifetime 24 h Qmax m3/h 20 30 60 90 140 200 300 500 1000 1200
or 5 min. 1.2 x Qmax

Qn continuous flow (±2%) m3/h 10 15 25 45 70 100 150 250 500 600


Qt transitional flow (±2%) m3/h 1.8 1.8 2.0 3.2 4.8 8.0 12 20 45 50
Qmin minimum flow (±5%) m3/h 0.6 0.6 1.0 1.4 2.0 3.5 4.5 8 20 25
starting flow m3/h 0.25 0.25 0.3 0.35 0.6 1.1 1.7 2.0 10 15

Performance data table according to PTB-A22 specification class B


Nominal Diameter DN 50 65 80 100 125 150 200 250 300
Size of meter (acc. to PTB-A22) Qn 15 25 40 60 100 150 250 400 600

Qmax maximum peak flow


short time m3/h 30 50 80 120 200 300 500 800 1200

Qn continuous flow (±3%) m3/h 15 25 40 60 100 150 250 400 600


Qt transitional flow (±3%) m3/h 2.25 3.75 6.0 9.0 15.0 22.5 37.5 60 90
Qmin minimum flow (±5%) m3/h 0.6 1.0 1.6 2.4 4.0 6.0 10.0 16.0 24.0

Typical Accuracy Curve Typical Head Loss Curve


DN 0
5

DN 0
0
DN 80
50

0
65

10

0
12

25
15

20

30
DN
DN

DN

DN
DN

DN
40
DN

Qmax = maximum peak flow


Qn = continuous flow ±2%
Qt = transitional flow ±2%
Qmin = minimum flow ±5%

WP-Dynamic for hot water


L B 4100 INT • Page 2 / 4
Dimensions and Weights

Nominal Diameter DN 40 50 65 80 80 100 125 150 200 250 300


Size of meter (acc. to PTB-A22) Qn 10 15 25 40 40 60 100 150 250 400 600
Dimensions overall length L *) mm 220 200 200 200 225 250 250 300 350 450 500
height H mm 120 120 120 150 150 150 160 177 206 231 256
h mm 69 73 85 95 95 105 118 135 162 194 226
g mm 200 200 200 270 270 270 280 356 441 466 491
Weights meter kg 7.4 7.7 10.0 13.6 14.0 18.0 20.5 35.5 50.5 72.3 99.3
measuring element kg 1.4 1.4 1.4 3.0 3.0 3.0 3.0 5.5 7.5 7.5 7.5
body kg 6.0 6.3 8.6 10.6 11.0 15.0 17.5 30.0 43.0 71.3 91.8

*) Other overall lengths on request

Dimension Picture Materials

Body cast iron

Measuring element plastic

Rotor plastic

We also use brass


the following materials stainless steel

Dials

Nominal Diameter Smallest reading Max. reading


DN m3 m3
m3 x 10 m3

40 ... 125 0.0005 1 000 000

150 ... 300 0.005 10 000 000

DN 40 ... DN 125 DN 150 ... DN 300

WP-Dynamic for hot water


L B 4100 INT • Page 3 / 4
Pulse Values

Pulser Pulse value


DN 40 ... DN 125 DN 150 ... DN 300

0.25 and 0.1 m3 1 and 2.5 m3


RD02 / RD022
or or
0.25 and 0.025 m3 2.5 and 0.25 m3

OD 02 0.001 m3 0.01 m3

OD 04 0.01 m3 0.1 m3

Available Design

Nominal Diameter DN 40 50 65 80 80 100

Size (acc. to PTB-A22) Qn 10 15 25 40 40 60

Overall Length mm 220 200 200 200 225 250

Order-No. PN 16 82 85 94 82 85 96 82 85 98 82 86 00 82 86 02 82 86 04

Nominal Diameter DN 125 150 200 250 300

Size (acc. to PTB-A22) Qn 100 150 250 400 600

Overall Length mm 250 300 350 450 500

Order-No. PN 16 82 86 06 82 86 08 82 87 18 82 87 20 82 87 44

Order Example

Type
Nominal Diameter
Temperature

L B 4100 INT / 004-0804 • Subject to change without notice


Pressure rate
Overall length
3
WP-Dynamic, DN 50, 130/16, L= 200 mm, 0,25/0,1 m Pulse values
drilled acc. to EN 1092 PN 16 Flange drilling
82 85 96 Order-No.