SG-200A _ 100kHz~200MHzDIGITAL RF SIGNAL GENERATOR

FG-1883 _ SWEEP FUNCTION GENERATOR

ED-4770 _ COMBO TESTER

PSA-6000 _6.2GHzSPECTRUM ANALYZER

PSA-3000 _3GHzSPECTRUM ANALYZER

RF SYS-3000 _RF SYSTEM DESIGN KIT

FC-1300B/FC-1130B _UNIVERSAL COUNTER(3GHz/1.3GHz)

PM-3001D _ POWER METER

SWR-3002 _SWR METER

HMP-100A_ STANDBY POWER METER

HMP-300A_ HANDY POWER METER

ED-333T _ 180W 3-MODE TRACKING DC POWER SUPPLY

www.ed.co.kr

Part4 test measurement_��.indd 2 2014-02-25 �� 11:13:22


• Signal Generator

SG-200A 100kHz~200MHz DIGITAL RF SIGNAL GENERATOR


• Built-in High Performance DSP Processor and Direct Digital Synthesizer(DDS)
• 0.5ppm High-stability TCXO and Internal Modulation Signal(20 Hz~15 kHz : 1 Hz Resolution)
• Wide Frequency Range : 100 kHz~200 MHz
• Frequency Resolution : 1 Hz
• Level Flatness : ± 1 dB
• Level Resolution : 0.1 dB
• High Output Power : +13 dBm
• Low Phase Noise : < -110 dBc(@Δf=10 kHz)
• Modulation : FM /AM/PM/FSK/PSK/ASK
• Digital Frequency Sweep Generator

> SPECIFICATION
• Carrier Frequency • Level
» Range : 100kHz to 200MHz » Range : -130 to +13dBm
» Resolution : 1Hz » Resolution : 0.1dB
• Reference Frequency » Accuracy : < ±1dB(@ ≥ -100dBm), < ±2dB(@ <-100dBm)
» Frequency Range : 10.000MHz » Characteristic Impedance : 50Ω
» Frequency Temp Stability : < 0.5ppm » VSWR : ≤ 1.5 : 1 @ ≤ 9dBm
» RT Frequency Stability : <0.5ppm » RF Flatness : ±1dB
» Stability vs. Aging : < 0.5ppm/year • Modulation Source
» Operating Temperature : 0˚C~50˚C » Frequency Range : 20Hz to 15kHz Sine ±0.01%
» Ref Out Frequency : 10.000MHz » Resolution : 1Hz
• Spectral Purity » Ext Input Impedance : 30kΩ
» Harmonics : < -30dBc » Ext Input Voltage : 3Vp-p
» Non-harmonics(Spurious) : < -40dBc • Amplitude Modulation
» Residual FM : < 5Hz(0.3 to 3kHz BW) Typically < 2Hz » Frequency Range : 100kHz~200MHz
» Residual AM : < 0.05% » Level : ≤ +7dBm
» Residual PM : < 0.01Rad(0.3 to 3kHz BW) » Operating Modes : Internal, External
Typically < 0.001Rad » Modulation Depth : 0% to 100%
» Phase Noise : <-110 dBc/Hz(@Δf=10 kHz) » Resolution : 0.1%

149 Part4 Test & Measurement

Part4 test measurement_��.indd 149 2014-02-25 �� 11:13:22


• Signal Generator

SG-200A 100kHz~200MHz DIGITAL RF SIGNAL GENERATOR

Electronics
Embedded

Electricals
> SPECIFICATION

Renewable
» Accuracy • PSK Modulation

energy &
› < ±(indicated value x 2%), Typically < ±(indicated value » Operating Mode : External

LED
x 0.5%), 100kHz~60MHz < ±30%, Typically < ±20%, » Frequency Range : 100kHz to 120MHz
60MHz~200MHz, @ AF=Internal 1kHz » PSK Mode : 2 Level PSK
» Distortion » Phase Shift(PH1 - PH0) : 0 to 6.28rad
› < 0.4% @ AF=Internal 1kHz, 100kHz~60MHz » Resolution : 0.01rad
› < 30% @ AF=Internal 1kHz, 60MHz~200MHz • GATE(ASK) Modulation

Communication
› Demod. BW=50Hz~15kHz » Operating Mode : External
• Frequency Modulation » Frequency Range : 100kHz to 120MHz
» Operating Modes : Internal, External » ON/OFF Ratio : ≥80dB

IT/
» Frequency Deviation : 0 to 200kHz » Rise/Fall Time : > 55μsec
» Resolution : 1Hz » Input Level : TTL : 1 ON, 0 Off
» Accuracy : < ±3% @ AF=Internal 1kHz • Sweep
» Distortion » Start F/Stop F : 100kHz to 120MHz
› < 0.05%, Typically < 0.03% » Resolution : 1Hz
› @ AF=Internal 1kHz » Type : Linear

Measurement
› Demod. BW=50Hz~15kHz » Direction : Up or Up_Down Repeat
› De-emp=50μsec » Step(Delta) Frequency : 1Hz~10MHz

Test&
• Phase Modulation » Step Frequency Resolution : 1Hz
» Operating Modes : Internal, External » Step Duration : 3.33333ms. FIX
» Phase Deviation : 0 rad to 3.14rad » Frequency Flatness : Peak-to-Peak 4 dB
» Resolution : 0.01rad
» Accuracy : < ±3% @ AF=Internal 1kHz GENERAL CHARACTERISTICS
» Distortion • Temperature Condition
› < 0.5% @ AF=Internal 1kHz » 10˚C~35˚C Specification

Automation

Intelligent
› Demod. BW=50Hz~15kHz » 0˚C~40˚C Operation

Robot/
• Memory for Device Settings • AC Power Supply : 90~240 V AC Free Voltage, 50/60Hz
» Storable Settings : 100 • Dimension : 435(W) x 110(H) x 390(D)mm
• FSK Modulation • Weight : 6.6kg
» Operating Mode : External
» Frequency Range : 100kHz to 120MHz
» FSK Mode : 2 Level FSK ACCESSORIES
» Frequency Shift(F1-F0) : 0 to 10MHz

Mechatronics
» Resolution : 1Hz • AC Power Cord : 1ea
» Frequency Flatness : Peak-to-Peak 4dB • BNC Cable : 1ea
• Operating Manual : 1ea

Simulation
Software

Typical Amplitute Flatness Typical Phase Noise Performance 200mHz Phase Noise
Pneumatics
Hydraulics

www.ed.co.kr 150

Part4 test measurement_��.indd 150 2014-02-25 �� 11:13:22


• Signal Generator

FG-1883 SWEEP FUNCTION GENERATOR

• Sweep, Symmetry and DC Offset


• Built-in Digital Frequency Counter
• Diverse Output Waveforms

> SPECIFICATION
• Frequency Range : 0.02Hz~2MHz(in 7Ranges) • External Frequency Counter
• Waveform: , , , Ramp, Pulse » Range : 0.005kHz~1000kHz
• Distortion( ) : Less than 1%(5Hz~20kHz) » Sensitivity : 100mV
• Rise/Fall Time( ) : Less than 100ns(Max. Output) » Input Impedance : 1MΩ, 25pF
• Linearity : 99%(to 100kHz) » Max. Input Voltage : 150Vp-p
• Output Level » Accuracy : 0.01% ±1 Count
» Hi : 20Vp-p(10Vp-p into 50Ω) • Operating Temp. : 0~45˚C, Below 85% R.H.
• Input Power : AC 220V, 50/60Hz
» Lo : 2Vp-p(1Vp-p into 50Ω)
• Dimension : 255(W) x 100(H) x 280(D)mm
• Output Impedance : 50Ω±5%
• Weight : 2.2kg
• DC Offset Control : ±10V(±5V into 50Ω)
• Symmetry Variable : 20:80~80:20 (0.02Hz~100kHz)
• VCF Input : 0~-10V ACCESSORIES
• Sweep Rate : 0.5Hz~50Hz
• Sweep Width • BNC-Clip Cord : 1ea
• AC Power Cord : 1ea
» 100:1
• Operating Manual : 1ea
• Frequency Display : 4 Digits(0.001kHz~2000kHz)

151 Part4 Test & Measurement

Part4 test measurement_��.indd 151 2014-02-25 �� 11:13:23


• Multi Function

ED-4770 COMBO TESTER

Electronics
Embedded

Electricals
• Function Generator : 100mHz~10MHz, 4 Digits LED-display, Internal Sweep Function
• Frequency Counter : 0Hz~100MHz, 8 Digits LED-display
• DMM : 4½digits, AC ±0.5%/DC ±0.05% Basic Accuracy
• DC Power Supply : 0~25V 1A Dual Output, 4 Digits LED-display

Renewable
energy &
LED
Communication
IT/
Measurement
Test&
Automation

Intelligent
Robot/
> SPECIFICATION

Mechatronics
Function Generator <10 MHz Function Generator>
• General Features • Attenuator
» 100mHz~10MHz Function Generator » 2 Steps : 20dB ±0.2dB
» Sine, Triangle, Square Generation Function » Variable : 0 to 20dB
» DC-offset • Square Wave Risetime
» Internal Sweep » typ. 15nS(10 to 90 %)
» 4 Digit LED-display • Frequency Accuracy
• Frequency Range : 100mHz~10MHz » Up to 10Hz ±(1%+3 Digit)
Simulation
Software

• Waveform : Sine, Square, Triangle wave » 10Hz~10MHz ±(10x10E-5+3 Digit)


• Sine Wave Distortion • DC Offset Range
» 100mHz~100kHz : 0.5% » Max ±2.5V(50Ω)
» 100kHz~500kHz : 1.5% • Internal Sweep
» 500kHz~10MHz : 3% » Sweep Speed : 20ms to 5s
• Output Voltage Characteristics » Sweep Range
» Output Voltage : Max 10Vp-p(50Ω) › 1:100
» Max 20Vp-p(Open) • Amplitude Flatness
Pneumatics
Hydraulics

» Impedance : 50Ω ±5% » 100mHz to 2MHz : Max ±0.5dB

www.ed.co.kr 152

Part4 test measurement_��.indd 152 2014-02-25 �� 11:13:23


• Multi Function

ED-4770 COMBO TESTER

> SPECIFICATION
Frequency Counter <100 MHz Frequency Counter>
• General Features • Time Base Stability
» 0 Hz~100 MHz Frequency Counter » Accuracy : ±1ppm
» Time Interval, Period Measurement » Aging Rate : ±2.5ppm/year
» 8 Digit LED-display • Attenuation : x1 , x20(Switch Selectable)
» 3 Selectable Gate Times • Period
• Display : 8 digits » Range : 10000sec to 66.6ns
• Frequency Range » Resolution : ±1 or 2 LSD
» 0Hz~100MHz(DC Coupled) • Gate Time : Range : 10s , 1s , 0.1s(3steps)
» 10Hz~100MHz(AC Coupled) • Time Interval
• Sensitivity : 60mV(1Hz~100MHz Sine Wave) » LSD : 100ns to 100ps
• Input Impedance : 1MΩ(Approx.) » Resolution : 1 or 2 LSD
• Max. Input Voltage : 250V(DC+AC peak)

Digital Multimeter
• General Features
» 4 ½ Digits Digital Multimeter • DC Current Measurement
» Beeper Function
Range Resolution Accuracy Protection
» AC ±0.5% Basic Accuracy
2mA 100nA
» DC ±0.05% Basic Accuracy
20mA 1μV ±(0.2%o.v.+ 0.01%o.r)
• Measurement Function Fuse(2A)
200mA 10μV
» DC : Voltage/Current
2000mA 100μV
» AC : Voltage/Current ±(0.3%o.v.+ 0.01%o.r)
10A 1mA Not
» Resistor Measurement
» Beeper Measurement • AC Current Measurement
Range Resolution Accuracy Protection
• DC Voltage Measurement
2mA 100nA
Range Resolution Accuracy Impedance Form 40Hz to 400Hz1μV
20mA 1μV
2V 100μV 200mA 10μV ±(0.7%o.v.+ 0.07%o.r) Fuse(2A)
20v 1mV ±(0.2%o.v.+ 0.005% o.r) 10MΩ 2000mA 100μV Form 40Hz to 400Hz
200v 10mV (Approx.) ±(1%o.v.+ 0.07%o.r)
10A 1mA Not
1000v 100mV ±(0.5%o.v.+ 0.005% o.r)

• AC Voltage Measurement • Resistor Measurement


Range Resolution Accuracy Impedance Range Resolution Accuracy Max. Input
2V 100μV Form 40Hz to 10kHz 2kΩ 100mΩ
20v 1mV ±(0.5%o.v.+ 0.07%o.r) 10MΩ 20kΩ 1Ω ±(0.1%o.v.+ 0.01%o.r) 500V
Form 40Hz to 100Hz (Approx.) OR
200v 10mV 200kΩ 10Ω +50 mΩ)
±(1%o.v.+ 0.07%o.r) 500V AC
750v 100mV 2MΩ 100Ω Peak
Crest Factor : up to 7 20MΩ 1kΩ ±(0.2%o.v.+ 0.01%o.r)

153 Part4 Test & Measurement

Part4 test measurement_��.indd 153 2014-02-25 �� 11:13:23


• Multi Function

ED-4770 COMBO TESTER

Electronics
Embedded

Electricals
> SPECIFICATION
DC Power Supply <25V,1A(Dual) Output DC Power Supply>

Renewable
energy &
• General Features • Resolution

LED
» 0~25V,1A Dual Output » Voltage : 100mV(Digital Volt-meter)
» High Stability, Low Ripple » Current : 1mA(Digital Ampere-meter)
» Current Limit Function • Transient Recovery Time
• Output Voltage : 0~25V(Dual Variable Output) » Below 80μs
• Output Current : 0~1A(Dual Variable Output) • Indicator
• Ripple And Noise : < 1mV » 4digits Digital Meter

Communication
• Resolution • Current Limit
» Line : 2.5mV below » 10mA to 1000mA

IT/
» Load : 0.05% below

GENERAL HARACTERISTICS ACCESSORIES

Measurement
• Test Lead : 1ea
• Input Voltage : 220V AC ±10%, 50/60Hz • Banana Cord : 2ea

Test&
• Dimensions : 293(w) x 92(H) x 388(D)mm • BNC-BNC Cable : 2ea
• Weight : 5.4kg • AC Power Cord : 1ea
• Instruction Manual : 1ea

Automation

Intelligent
Robot/
Mechatronics
Simulation
Software
Pneumatics
Hydraulics

www.ed.co.kr 154

Part4 test measurement_��.indd 154 2014-02-25 �� 11:13:23


• Spectrum Analyzer

PSA-6000 6.2GHz SPECTRUM ANALYZER

The Model PSA-6000 Spectrum Analyzer is a fully synthesized RF Spectrum Analyzer featuring simple
user controls which allow the novice or the seasoned expert to use the PSA-6000 right out of box. The
PSA-6000 provides you with a powerful RF test and measurement tool for CDMA and WCDMA RF
systems, broadcast RF systems, ISM Band, Wireless LAN applications, EMI/EMC.

The features include 6.4”color display, centronics printer, internal memory, USB host, built in CDMA
measurement(ACP,Channel Power and Occupied Bandwidth). The PSA-6000 Spectrum Analyzer
gives educational institutions, mobile and communication system manufactures and RF product service
centers a quality RF test instrument at an unbelievably affordable price.

> FEATURES
• High-performance Digital Synthesizer Method • Ease-of-use Key Buttons
• Wide Frequency Coverage : 9kHz~6.2GHz • CDMA Measurement : ACPR, ACLR, OCBW, Channel Power
• Superior Resolution : Minimum 1Hz • Various and Convenient Interfaces : USB, LAN
• Compact & Portable Size • 0.5 ppm High Precision Reference
• Wide Input Dynamic Range : -105~20dBm

Various and Convenient Interfaces Auto Set Function

GPIB(Option), LAN(Option), Automatically displays and


RS-232C, Printer, EXT sets maximum signal trace
Trigger REF I/O(10 MHz)

155 Part4 Test & Measurement

Part4 test measurement_��.indd 155 2014-02-25 �� 11:13:23


• Spectrum Analyzer

PSA-6000 6.2GHz SPECTRUM ANALYZER

Electronics
Embedded

Electricals
4. USB Interface
• Can store measured data into the USB Memory
Remote Control Function through its builtin USB Host that supports USB 1.1 and
Remote Controls the Analyzer and USB 2.0(GIF Format).

Renewable
energy &
Manages Fata Thru PC or Internet • Can convert measured data to MS Excel as it also

LED
supports the CSV file format.
• Supports Nearly all types of printers such as
Centronics printer and USB interface printer.
• Firmware can be upgraded through USB by clicking on
Save/Recall Function
Saves and Manages
our website, http://www.ed.co.kr.

Communication
Measurement trace and its
State in the Internal Memory 5. Large Internal Memory Space
• Waveform : Stores Maximum 900 waveforms

IT/
• State : Stores Maximum 3,000 states
• Easily stores/calls waveforms and states of the
equipment based on various types of application and
usage
1 2

Measurement
> SPECIFICATION

Test&
3
• Frequency
» Range : 9kHz to 6.2GHz
» Resolution : Minimum 1Hz
» Span Range
› 100Hz/div to 600MHz/div
› 1,2,5Steps Selection(Automatic), ZERO Span,

Automation

Intelligent
5 4 FULL Span (9kHz to 6.2GHz)

Robot/
» Frequency Selection : Start, Stop, Center Span Setup
1. High Definition 640x480 Color TFT LCD » Span Accuracy : ±3% of the Indicated Span Width
High definition color TFT LCD enables high precision » Readout Accuracy : ≤ ±(Indicated Frequency
measurement and natural data display. x reference Frequency Accuracy+Span x Span
2. Simple and Easy to use KEY Accuracy+50% of RBW)
Keys are allocated for user’s conveniences so that users can be » Phase Noise : ≤ -90dBc/Hz @10 kHz offset
easily familiar with them. And they Provide various functions. • Amplitude

Mechatronics
3. CDMA Measurement » Range : +20dBm~-105dBm
• Channel Power(CHP) Measurement : The PSA-6000 model
» Average Noise Level(1 kHz RBW, 10Hz VBW)
provides power measurement functions for mobile
› ≤ -105dBm : 150kHz~2.7GHz
communication and simple menus. Measured values are
› ≤ -100dBm : 2.7GHz~6.2GHz
automatically displayed at the bottom of trace.
» Amplitude Unit : dBm, dBmV, dBμV, V, mV, μV,
• OBW Measurement : Measures the Occupied Bandwidth(OBW)
of modulation signal in the unit of %. W, mW, μW
• ACP Measurement : Measures the influence of transmitted » Display Scale Linearity
power on the Adjacent Channel, or the ratio of power to the › ≤ ±1.5dB/70dB(10dB/div), ≤ ±1.5dB/40dB(5dB/div)
Simulation

› ≤ ±0.5dB/8dB(1dB/div), ≤ ±0.5dB/16dB(2dB/div)
Software

Adjacent Channel throughout the mobile communication


system using multi-channel. » Frequency Response(based on 0dB Atten)
› -3.5~1.5dB(100kHz~10MHz)
› ±1.5dB(10MHz~6.2GHz)
» Reference Level
› Range : 20dBm~-90dBm
› Resolution : 0.1dB
› Accuracy : ±1.5dB
Pneumatics
Hydraulics

» 2nd Harmonic Distortion : ≤ -60dBc, -40dBm input


» Intermodulation Distortion : ≤ -70dBc, -40dBm Input
» Residual Spurious : ≤ -85dBm(Input terminated, 0dB
attenuation)
» Other Input Spurious : ≤ -60dBc, -30dBm Input

www.ed.co.kr 156

Part4 test measurement_��.indd 156 2014-02-25 �� 11:13:23


• Spectrum Analyzer

PSA-6000 6.2GHz SPECTRUM ANALYZER

> SPECIFICATION
» Resolution Bandwidth GENERAL CHARACTERISTICS
› Selection : 1kHz, 3kHz, 10kHz, 30kHz, 100kHz, 300kHz, » Dimension : 350(W) x 195(H) x 375(D)mm
1MHz, 3MHz, 9kHz, 120kHz » Weight : 10kg
› Accuracy : ±20% » Warming up Time : 20 minutes for the precision
› Selectivity : 60dB/3dB Ratio < 15:1 measurement
60dB/6dB Ratio < 12:1(9kHz, 120kHz) » Power
› Switching Error : ≤ ±1.0dB(1 kHz Reference RBW) › Source Voltage and Frequency : 100~240 VAC at
» Video Bandwidth : 10Hz to 3MHz in 1-3-10 Step 50/60Hz
• Sweep › Power Consumption : 80 Watts maximum without
» Rate : 100 ms to 1000 Sec, 40 ms to 1000 Sec(Zero Span) options
» Accuracy : ≤ ±20% » Operating Temperature : 0˚C to 40˚C
» Trigger Source : External(rear), Video, Freerun, Line » Storage Temperature : -20˚C to 70˚C
» Trigger Modes : Continuous, Single » RF Emissions, Immunity
» Trigger Level : TTL level › RF Emissions : EN 55011, FCC PART15 Section 15.101
• Screen Display › RF Immunity : EN 61326
» Type : 6.4” Color TFT LCD
» Display Resolution : 640(H) x 480(V) active display area
» Marker Mode
› Peak Search, Delta Marker, Marker to Center OPTION
› Marker to Reference(8 Markers Maximum)
• Input • GPIB Interface(IEEE 488 Bus)
» RF Input Connector : N type Female, 50 ohm Nominal • Ethernet Interface : for Internet Remote Control
» VSWR • Soft Carrying Case
› 150kHz~3.0GHz : VSWR <1.5:1(based on 0 dBm Ref Level) • General Kit Set
› 3.0GHz~6.2GHz : VSWR < 2:1(based on 0 dBm Ref • CATV Kit Set
Level), Typical < 1.5:1
» Maximum Input Level : 0 VDC, +20dBm
• Memory
» Trace Storage : Maximum 900 waveforms
» Setup Storage : Maximum 3000 states
• Standard(10MHz, Ref.)
» Temperature Stability : ± 0.5ppm
» Aging : ± 0.5ppm/Year
» Connector : BNC Female
» Input Level : -5dBm to +15dBm
» Output Level : 10MHz, +8dBm Nominal
• Interface
» RS-232C : Null Modem for Remote Control
» Printer
› Driver : PCL Command, HP, EPSON, Laser-Jet, Desk-Jet
› Connector : Standard 25 Pin female D-Sub using
parallel connector
» USB Host
› Printer Drive : PCL Command, HP, EPSON, Laser-Jet,
Desk-Jet
› USB Storage Device : Supports 1.1 and 2.0, image file
for storage, GIF format
» Ethernet(Option)
› 10-Base-T Ethernet : Supports Internet remote control
» GPIB Interface(Option) : IEEE 488 bus

157 Part4 Test & Measurement

Part4 test measurement_��.indd 157 2014-02-25 �� 11:13:24


• Spectrum Analyzer

PSA-3000 3GHz SPECTRUM ANALYZER

Electronics
Embedded

Electricals
PSA-3000 is digital synthesizer method Spectrum Analyzer of wide-band frequency and dynamic range.
It is popular spectrum analyzer widely applicable to the mobile telecommunications(CDMA/WCDMA),
RF system, broadcastings, EMI/EMC and so on.
It provides various state of the art functions like 6.4 inch Color TFT LCD, Centronics Printer, USB

Renewable
energy &
Host for data storage, CDMAmeasuring functions(ACP, Channel Power, Occupied Bandwidth) with its

LED
reasonable prices.
It can be used for education authorities for mobile telecommunications and RF, production lines for
terminal and telecom equipment as well as for maintenance purposes.

Communication
IT/
Measurement
Test&
Automation

Intelligent
Robot/
> FEATURES

Mechatronics
• High-performance Digital Synthesizer Method • Wide Input Dynamic Range : -130~20dBm
• Wide Frequency Coverage : 9kHz~3.0GHz • Ease-of-use Key Buttons
• Superior Resolution : Minimum 1 Hz • CDMA Measurement : ACPR, ACLR, OCBW,
• Compact & Portable Size Channel Power
• Pre Amp as Standard • Various and Convenient Interfaces : USB, LAN
• 0.5 ppm High Precision Reference
Simulation
Software

Various and Convenient Auto Set Function


Interfaces Automatically displays and
sets maximum signal trace
GPIB(Option), LAN(Option),
RS-232C, Printer, EXT
Trigger REF I/O(10 MHz)
Pneumatics

Save/Recall Function
Hydraulics

Remote Control Function


Remote Controls the Analyzer Saves and Manages
And Manages Fata Thru PC or Measurement trace and its
Internet State in the Internal Memory

www.ed.co.kr 158

Part4 test measurement_��.indd 158 2014-02-25 �� 11:13:24


• Spectrum Analyzer

PSA-3000 3GHz SPECTRUM ANALYZER

5. Internal Memory of Large Storage Capacity


1 2
• Storage Capacity for Waveforms : Maximum 900 waveforms
• Storage Capacity for States : Maximum 3,000 states
• Easily stores waveforms and states of equipments according
3
to the various application and use

> SPECIFICATION
5 4 6 • Frequency
» Range : 9kHz to 3.0GHz
1. High Definition 640 x 480 Color TFT LCD » Resolution : Minimum 1Hz
With its high definition color TFT LCD, users rarely feel fatigues
» Span Range
on their eyes even after long-hours of use. It provides high
precision measurement as well as natural data output › 100Hz/div to 300MHz/div
› 1,2,5Steps Selection(Automatic), ZERO Span, FULL
2. Simple and Easy to use KEY Span(9kHz to 3.0GHz)
Keys are allocated for user’s conveniences so that users
» Frequency Selection : Start, Stop, Center Span Setup
can be easily familiar with them. And they provide various
functions. » Span Accuracy : ±3% within a designated Span range
» Readout Accuracy : ≤ ± (Indicated frequency x Reference
3. CDMA Measurement Frequency Accuracy + Span x Span Accuracy + 50% of
• Channel Power(CHP) Measurement : It measures the power RBW)
of mobile telecommunications channel. It screens out the
output data automatically with its simple menu operation. » Phase Noise : ≤ -90dBc/Hz(Based on 10kHz Offset)
• OBW Measurement : It measures the Occupied bandwidth of
modulation signal by %. • Amplitude
» Range : +20dBm~-105dBm, +20dBm~-130dBm(Pre Amp
ON)
» Average Noise Level(1kHz RBW, 10Hz VBW)
› ≤ -105dBm : 150kHz~2.7GHz
› ≤ -127dBm(Pre Amp On) : 20MHz~2.7GHz
› ≤ -100dBm, -123dBm(Pre Amp On) : 2.7GHz~3GHz
› ≤ -130dBm(Pre Amp On) : Typically
» Amplitude Unit : dBm, dBmV, dBμV, V, mV, μV, W, mW,μW
» Display Scale Linearity
› ≤ ±1.5dB/70dB(10dB/div), ≤ ±1.5dB/40dB(5dB/div)
› ≤ ±0.5dB/8dB(1dB/div), ≤ ±0.5dB/16dB(2dB/div)
» Frequency Response(Based on OdB Atten)
• ACP Measurement : It measures the effects on Adjacent › -3.5~1.5dB(100kHz~10MHz)
Channel caused by transmitted power or the power rates with › ±1.5dB(10MHz~3GHz)
Adjacent Channel in Mobile Telecommunication Systems using
» Reference Level
multi channels. It checks all measured values and waveforms
on one screen. › Range : 20dBm~-90dBm
› Resolution : 0.1dB
4. USB Interface › Accuracy : +/-1.5dB
• Stores measured data in USB memory with USB Host » 2nd Harmonic Distortion : ≤ -60dBc, -40dBm Input
supporting USB 1.1, 2.0(GIF Format)
» Intermodulation Distortion : ≤ -70dBc, -40dBm Input
• Converts measured data into MS Excel by supporting CSV
file format » Residual Spurious : ≤ -85dBm(Input Terminated 0 dB
• Supports all types of printer not only Centronics printer but Attenuate)
USB Interface printer » Other Input Spurious : ≤ -60dBc, -30dBm Input
• Upgrade the Firmware of Analyzer through USB by
downloadingthe upgraded firmware provided in ED company’s
Website.

159 Part4 Test & Measurement

Part4 test measurement_��.indd 159 2014-02-25 �� 11:13:24


• Spectrum Analyzer

PSA-3000 3GHz SPECTRUM ANALYZER

Electronics
Embedded

Electricals
> SPECIFICATION
» Resolution Bandwidth GENERAL CHARACTERISTICS

Renewable
› Selections : 1kHz, 3kHz, 10kHz, 30kHz, 100kHz, 300kHz, » Dimensions : 350(W) x 195(H) x 375(D)mm

energy &
» Weight : 10 kg

LED
1MHz, 3MHz, 9kHz, 120kHz
› Accuracy : ±20% » Warming up time : 20 minutes for the precision
› Selectivity measurement
- 60dB/3dB ratio < 15:1 » Power
- 60dB/6dB ratio < 12:1(9kHz, 120kHz) › Source Voltage and Frequency : 100-240 VAC at
› Switching Error : ≤ ±1.0dB(1kHz Reference RBW) 50/60Hz

Communication
» Video Bandwidth : 10Hz to 3MHz in 1-3-10 step › Power Consumption : 80 Watts maximum without
• Sweep option
» Rate : 100 ms to 1000 sec, 40 ms to 1000 sec » Operating Tempcerature : 0˚C to 40˚C

IT/
(Zero Span) » Storage Tempcerature : -20˚C to 70˚C
» Accuracy : ≤ ±20% » RF Emissions, Immunity
» Trigger Source : External(Rear), Video, Freerun, Line › RF Emissions : EN 55011, FCC PART15 Section 15.101
» Trigger Modes : Continuous, Single » RF Immunity : EN 61326
» Trigger Level : TTL Level
• Memory

Measurement
» Trace-Setup Storage OPTION

Test&
› Trace Storage : Maximum 900 waveforms
› Setup Storage : Maximum 3000 states • Tracking Generator
• Screen Display • GPIB Interface(IEEE 488 Bus)
» Type : 6.4”Color TFT LCD • Ethernet Interface : for Internet Remote Control
» Display Resolution : 640(H) x 480(V) active display area • Soft Carrying Case
» Marker Modes • General Kit Set
› Peak search, Delta marker, Marker to Center • CATV Kit Set

Automation
› Marker to Reference(8 Markers Maximum)

Intelligent
Robot/
• Input
» RF Input Connector : N type Fem ale, 50 ohm Nominal
» VSWR
› 150 kHz~3.0 GHz, VSWR<1.5:1(Based on 0 dBm Ref
Level)
» Maximum Input Level : 0 VDC, +20dBm
• Standard Frequency(10MHz, Ref.)

Mechatronics
» Temperature Stability : ±0.5 ppm
» Aging : ±0.5 ppm/Year
» Connector : BNC Female
» Input Level : -5dBm to +15dBm
» Output Level : 10MHz, +8dBm nominal
• Interface
» RS-232C
» Printer
› Driver : PCL Command, HP, EPSON, Laser-Jet, Desk-Jet
Simulation
Software

› Connector : Standard 25 Pin female D-Sub using


Parallel Connector
» USB Host
› Printer Driver : PCL Command, HP, EPSON, Laser-Jet,
Desk-Jet
› USB Storage Device : Supports 1.1 and 2.0, image file
for storage, GIF format
» Ethernet(Option)
Pneumatics
Hydraulics

› 10-Base-T Ethernet : Supports Internet Remote Control


» GPIB Interface(Option) : IEEE 488 bus

www.ed.co.kr 160

Part4 test measurement_��.indd 160 2014-02-25 �� 11:13:24


• Spectrum Analyzer

RF SYS-3000 RF SYSTEM DESIGN KIT

• Signal Generator including Local OSC function


• Active/passive modules comprising the RF System Design kit
• Transmitter/Receiver for mobile communication

> EXPERIMENTS
• How to Use Spectrum Analyzer / Scalar Network Analyzer • Tx DAC, Baseband LPF, IQ Modulator, IQ Demodulator,
» Usage of Spectrum Analyzer / Scalar Network Analyzer Transmitter / Receiver
which is the basis of RF measurement, along with » Conversion of Analog Baseband from the Digital
calibration procedures Baseband, IF or RF conversion at the Baseband, QPSK
• Passive Module (Element) using the Modulator and characteristics of RF
» Attenuator, Monolithic Filter(LPF, HPF, BPF), Microstrip Transmitter in digital communications ; and verification
Filter(BPF, LPF), SAW Filter(RF, IF), Duplexer, Combiner / of each performance through Spectrum Analyzer
Divider, Antenna, Coupler, Detector(Log Amp, Schottky
• Up/Down Converter, Small-size Repeater, Signal Generator
Diode)
• RF MMIC Module (Element) » Basic principles and design applications of Up/Down
» RF Switch, Relay Switch, RF Digital Step Attenuator, Converter, Small-size Repeater and Signal Generator in
Voltage Variable Attenuator the system block
• Frequency Conversion • RF System Parameter
» Understanding of frequency conversion through » System performance testing and verification on Noise
performing experiments on Mixer and MMIC Mixer, Figure, Noise Floor, Harmonic, Inter Modulation, P1dB,
mathematical frequency conversion and actual IP3, Insertion Loss, Isolation, VSWR, S-Parameter,
differences in frequency conversion through the Mixer Frequency Accuracy, Amplitude Accuracy, Linear
element Scale_dB Scale,Phase Noise, Phase Linearity
• Local OSC, PLL Synthesizer • CDMA, WCDMA Modulator / Demodulator
» Design of OSC, VCO and Reference(VCXO, TCXO, » Analog base band at digital signals, CDMA through IQ
VCTCXO, OCXO) PLL Synthesizer modulation and creation processes of WCDMA signal;
• Amplifier
and CDMA and WCDMA demodulation processes and
» Understanding and performance verification of Gain
theories through IQ demodulation
Block Amp, Low Noise Amp and Power Amp
• Direct Digital Synthesizer (DDS) • Waveform Generator
» Various applications of DDS, a precision digital element » Understanding of the Waveform Generator(Function
• Frequency Doubler / Divider Generator) that generates CW Sine, Triangle Wave and
» Verification of the Frequency Doubler / Divider Square Wave
characteristics for RF System and Local OSC expansion

161 Part4 Test & Measurement

Part4 test measurement_��.indd 161 2014-02-25 �� 11:13:24


• Spectrum Analyzer

RF SYS-3000 RF SYSTEM DESIGN KIT

Electronics
Embedded

Electricals
> CONFIGURATION
• RF System Design Kit Test Module/System Module Kit

Renewable
• PSA-3000+Tracking Generator(Option) • Performance Test for Module/System

energy &
• Composed of Module/System used in industrial sites

LED
• Operation Manual
• Accessories • Includes Local OSC, a function of Signal Generator
» SMA(m)~SMA(m), 1meter : 2ea • Active/Passive module to comprise the system
» SMA(m)~SMA(m), 30cm : 4ea • Transmitter/Receiver for mobile communication
» 800MHz ANT : 2ea

Communication
Spectrum Analyzer(PSA-3000)+Tracking Generator
• Performance Test for Module/System
• Capability of Scalar Network Analyzer with Tracking

IT/
Generator
• High Performance Digital Synthesizer mode
» Frequency Rance : 9KHz~3GHz
» Amplitude Rance : -130dBm~20dBm

Measurement
Test&
> SPECIFICATION
3. Direct Digital Synthesizer
• Frequency Range : 1~120MHz
• Frequency Resolution : 1Hz
• Output Power : 5~-10dBm(±2dB)
• Output Type : TTL or CW

Automation

Intelligent
• Modulation : FM, AM, PM, FSK, PSK, ASK

Robot/
4. Frequency Up Converter
• Intermediate Frequency : 70 ±5MHz
• Input Power Level : Below -10dBm
• RF Output Frequency : 880 ± 10MHz
• RF Output Level(-10dBm Input) : 6.8dBm(±1dB)

Mechatronics
• System Gain : 16 ± 1dB

1. PLL Synthesizer
PLL Module
• Frequency Range : 700~1600MHz • Frequency : 800~820MHz
• Output Power : Above 7dBm(Max 17dBm) • Output Power : 3dBm
• Phase Noise : < -90dBc/Hz @ 10kHz Offset
5. Frequency Down Converter
10 MHz Ref TCXO • RF Input Frequency : 880 ± 10MHz
Simulation

• Frequency : 10MHz • RF Input P1dB : -6dBm


Software

• Temperature Stability : ±2ppm • System Gain : 19dB


• Aging : ±2ppm/Year • IF Output Frequency : 70 ± 5MHz

6. Frequency Divider
2. CDMA Transmitter(Including IQ Modulator)
• Input Frequency : 700~1600MHz
• Frequency Range : 870~890MHz(Step 1MHz)
• Input Power : -12~12dBm
• Modulation : CDMA 2000 : Pilot Channel, WCDMA : CPICH
• Output Frequency
Pneumatics
Hydraulics

• Output Power : -12dBm~-27dBm(1dB Step) » Input Frequency/2


• Modulation Quality(Rho, EVM) : > 0.99 » Input Frequency/4

www.ed.co.kr 162

Part4 test measurement_��.indd 162 2014-02-25 �� 11:13:24


• Spectrum Analyzer

RF SYS-3000 RF SYSTEM DESIGN KIT

> CONFIGURATION
7. Detector
• Frequency : DC~440MHz
• Slope : +24mV/dB
• Dynamic Range : 95dB

8. Pin Diode Switch


• Frequency Range : 300kHz~3GHz
• Insertion Loss : 4dB(@ 1GHz)
• Isolation : 20dB or above

9. Mixer
• RMS-30
» LO/RF Frequency : 200MHz~3GHz
» IF Frequency : DC~1GHz
» LO Power : 7dBm or above
» Conversion Loss : Max 9.8dB 16. Passive Attenuator
• Short Key Diode Mixer - HSMS282R • Type : Pi, T Type
» LO/RF Frequency : 700MHz~1.2GHz • Attenuation : 3dB(@ 500MHz), 5dB(@ 500MHz), 10 ± 1dB
» IF Frequency : 10~130MHz
» Conversion Loss : Max 14dB 17. LC Filter
• LPF : Butterworth, Chebyshev
10. Gain Block Amp • HPF : Butterworth, Chebyshev
• Amp 1 • BPF : Butterworth, Chebyshev
» Frequency Range : 250~4000MHz
» Gain : Max 13.5dB(Typical 10dB) 18. SAW Filter
» P1dB : 22dBm, OIP3 : 41dBm, NF : 3dB • Frequency : 70MHz, 836.5MHz, 881.5MHz
• Amp2
» Frequency Range : 700~1000MHz 19. Duplexer
» Gain : Max 14dB(Typical 10dB) • Duplexer 1
» P1dB : 17dBm, OIP3 : 35dBm, NF : 0.9dB » Frequency : RX 836.5 ± 12.5MHz, TX 881.5 ± 12.5MHz
» Insertion Loss : 4dB
• Amp3 • Duplexer 2
» Frequency Range : DC~7GHz, Gain : Max 22dB, » Frequency : RX 1765 ± 12.5MHz, TX 1855 ± 12.5MHz
P1dB : 9dBm, OIP3 : 22 dBm, NF : 4.9dB » Insertion Loss : Typical 4dB(Max 9dB)

11. Waveform Generator 20. DR Filter


• Frequency : 1Hz~1MHz • Frequency : 800MHz, 1100MHz
• Waveform : CW Sine, Triangle Wave, Rectangular Wave
21. Power Combiner/Divider
12. VCO • Wilkinson Combiner/Divider
• Frequency Range : 630~950MHz » Frequency : 2.1~2.7GHz
• Output Power Level : -10~-6dBm » Loss : 4.5dB
» Isolation : 10dB or above
13. Voltage Variable Attenuator • TCP-2-25
• Frequency Range : 100kHz~3MHz » Frequency : 200~2500MHz
• Insertion Loss : Max 4.5dB » Loss : Max 6dB
• Attenuator Range : 30dB Attenuation » Isolation : 15dB
• Control Voltage : 0~2.4V
22. Microstrip Filter
14. CDMA Receiver(Including IQ Demodulator) • Edge Coupled Type BPF
• RF Input Frequency : 880 ± 10MHz » Center Frequency : 1.65GHz
• Input Power : -12~-35dBm » BW : 270MHz
• Output Signal : Baseband Analog I, Q • Hairpin Type BPF
» Center Frequency : 1.7GHz
15. Digital Step Attenuator » BW : 250MHz
• Frequency Range : 9kHz~3GHz • Elliptic Type LPF : -3dB BW ; 2GHz
• Attenuation Step : 1dB(Total 31dB Range) • Stub Type LPF : -3dB BW ; 1.85GHz

163 Part4 Test & Measurement

Part4 test measurement_��.indd 163 2014-02-25 �� 11:13:24


• Spectrum Analyzer

RF SYS-3000 RF SYSTEM DESIGN KIT

Electronics
Embedded

Electricals
> CONFIGURATION > SPECIFICATION
23. Coupler GENERAL CHARACTERISTICS

Renewable
• Coupled Line Coupler • Dimension : 525(W) x 180(H) x 340(D)mm

energy &
LED
» Frequency : 700~900MHz • Weight : 7.4kg
» Insertion Loss : 0.5dB • Power : 100~240VAC at 50/60 Hz
» Coupling Value : Typical 20dB(Min 17dB) • Operating Temperature : 0˚C~35˚C
• Coupled Line Coupler • Storage Temperature : -10˚C~50˚C
» Frequency : 1000~2400MHz
» Insertion Loss : 1.5dB

Communication
ACCESSORIES
» Coupling Value : Typical 18dB
• Branch Line Coupler

IT/
• SMA(m)~SMA(m), 1meter : 2ea
» Frequency : 1600~2000MHz
• SMA(m)~SMA(m), 30cm : 4ea
» Insertion Loss : 5 dB • 800MHz ANT : 2ea
» Coupling Value : Typical 5dB • Experiment Manual : 1ea
» Phase : 90˚

Measurement
Test&
Automation

Intelligent
Robot/
Mechatronics
Simulation
Software
Pneumatics
Hydraulics

www.ed.co.kr 164

Part4 test measurement_��.indd 164 2014-02-25 �� 11:13:24


• Counter & Bridge

UNIVERSAL COUNTER
FC-1300B/FC1130B (3GHz/1.3GHz)
• Frequency : 0.1Hz~3GHz [FC-1300B], 0.1Hz~1.3GHz [FC-1130B]
• High stability built-in TCXO, Microprocessor [FC-1300B]
• High accuracy and sensitivity
• High resolution 8 digit 7 segment LED display
• Multi-functional measurement and self-check

> EXPERIMENTS
• Display : 8 Digits(7 Segment LED) • Input Impedance
• Indicator : MHz, kHz, μs, G.T(Gate Time), Hold Over, Trigger » Input A, B : 1MΩ, <40pF
• Frequency Measurements » Input C : 50Ω
» Input A(Hi) : 10MHz~100MHz • Coupling
» Input B(Lo) : 0.1Hz~10MHz » Input A, B : AC or DC
» Input C : 100MHz~1.3GHz(FC-1130B » Input C : AC
100MHz~3GHz(FC-1300B) • Low Pass Filter : 100kHz(Input A, B)
» Accuracy : ±Time Base Error ±1 Count • Attenuator : x1 or x10(Input A, B)
» Resolution : 0.1/1/10/100Hz(Input A-Low Mode) • Maximum Input
1/10/100/1000Hz(Input A-High Mode) » Input A, B : 250V(DC+AC Peak)
» Gate Time : 10/1/0.1/0.01s » Input C : 3Vrms Sine Wave
• Period Measurement • Self-check
» 200ms~0.5μs(at INPUT A) » 10MHz
» Accuracy : ± Time Base Error ±1 Count ± Input A Trigger Error » Gate Time : 10/1/0.1/0.01s
» Resolution : 100ps/1ns/10ns/100ns • Base Signal Output
• Ratio Measurement
» Open : 1Vp-p Min. at 1MΩ
» Input A : 10MHz~100MHz
» 50Ω : 500mVp-p Min.
» Input B : 0.1MHz~10MHz
• Time Base Stability : 3x10 ⁻⁶ /week
» Accuracy : Input B Trigger Error ÷ (Input BxGate Time) ±1 • Operating Temperature
Count » 0~40˚C , Below 85% R.H.(Accuracy Specified at 25˚C ±5˚C )
» Resolution : ±Input B÷(Input A x Multiplier) • Input Voltage : AC 100/120/220/240V±10%, 50/60Hz
» Multiplier : 1, 10, 100, 1000 • Dimension : 255(W) x 100(H) x 270(D)mm
• Totality Count • Weight : 1.9kg
» DC~10MHz(at Input A)
» Capacity : 0~99999999(Overflow)
» Speed : 10⁷/s Max. ACCESSORIES
• Time Interval Measurement
» 0.5μs~200ms • Input Cord : 1ea • Spare Fuse : 2ea
» Accuracy : ± Time Base Error ± 1 Count ± Input A Trigger
• RS-232C Cable : 1ea • Operation CD : 1ea
Error ± Multiplier
» Resolution : 100ps/1ns/10ns/100ns • AC Power Cord : 1ea • Instruction Manual : 1ea
» Multiplier : 1, 10, 100, 1000
» Min. Pulse Width : 250ns

165 Part4 Test & Measurement

Part4 test measurement_��.indd 165 2014-02-25 �� 11:13:24


• Meter

PM-3001D POWER METER

Electronics
Embedded

Electricals
• Small-size RF Power Meter with power sensor
• Ideal measurement of power transfer characteristics, I/P vs O/P Power
• 8 Character x 1 Line LCD with backlight

Renewable
energy &
LED
Communication
IT/
Measurement
Test&
Power Meter Power Sensor Cable AC Adapter

Automation

Intelligent
Robot/
> SPECIFICATION
• Frequency Range : 0.01~12.4GHz • Input Connector : Type N Male
• Power Sensor : Diode Sensor • Response Time : 0.1s
• Display : 8 Character x 1 Line LCD • Calibration Frequency : 10GHz(7GHz)

Mechatronics
• Power Reading Ranges • Accuracy of Calibration : ±2%
» 0~99.9mW in 3 Ranges [XXX uW , X.XX mW , XX.X mW] • Frequency Flatness : ±0.5dB(Ref 7GHz)
• Max. Safe Input Power : 200mW • Power : 9V Alkaline Battery or AC Adapter
• Peak Power Rating : 1W 1s • Operating Temperature Range : 0˚C~+40˚C
• Input Impedance : 50Ω • Dimension
• Input VSWR(max) » Meter : 70(W) x 45(H) x 140(D)mm
» 1.4 : 1 » Sensor : 30(W) x 25(H) x 85(D)mm
• Weight : 0.75kg(Meter+Sensor+Cable+AC Adapter)
Simulation
Software
Pneumatics
Hydraulics

www.ed.co.kr 166

Part4 test measurement_��.indd 166 2014-02-25 �� 11:13:24


• Meter

SWR-3002 SWR METER

• Accurately, Read SWR directly on the scale


• Operating frequency 1kHz with variable bandwidth 15~130Hz
• Calibration factor of output amplifier is 110dB with the o/p terminal on the rear panel
• Meter scale shows Square Law Characteristics using Crystal Detector

> SPECIFICATION
• Sensitivity : 1V FS • Bandwidth : 15 to 130Hz, Adjustable
• Noise : Below 7.5dB FS at Rated Sensitivity • Amplifier Output : 0~0.3Vrms(NORM), 0~0.8Vrms(EXPAND)
• with input terminated 5000Ω • Meter Scale Tuned for Square-law Detectors
• Range : 70dB(10dB and 2dB step) • Mechanism Taut-band Suspension
• Accuracy : ±0.05dB(10dB step) • Input Voltage : 220V, 50/60Hz
• Input Impedance : 2500 to 1000Ω Optimum Source • Dimension : 325(W) x 285(H) x 220(D)mm
Impedance for Low Noise • Weight : 4kg
• Input Frequency : 1000Hz, Adjustable 7%

167 Part4 Test & Measurement

Part4 test measurement_��.indd 167 2014-02-25 �� 11:13:24


• Meter

HPM-100A Standby Power Meter

Electronics
Embedded

Electricals
IEC KS C 62301 is a standard for measuring consumption power and standby power. This meter is a Plug &
Play type and is considered an innovation in the area of power measurement. You can plug the products for
power measurement into a universal multi socket without using additional cables, so you can use four items
at the same time. This meter is used to measure a variety of items such as AC voltage, current, power factor

Renewable
energy &
correction, frequency, wattage and carbon dioxide emission. It is also widely used by public institutes, mass

LED
retailers, industrial institutes, and consumer authorities. It’s usage as a portable wattmeter for educational
purposes in elementary and junior middle schools is also widespread.
In addition, our products has been certified as a world-class products, an excellent procurement products,
and an innovative products by the Korea Agency for Technology and Standards.

Communication
IT/
Measurement
Test&
Automation

Intelligent
Robot/
Mechatronics
> Features
• Complied with the IEC 62301 Safety standard
• Complied with the EN 61010-1 Safety standard
• Battery & Adaptor are not necessary
• Timely set (1hour / 24hour)
• Measurement standby and consumption power (0.009W ~2,500W)
Simulation

• Voltage, Current, Watt, Frequency (Display 4 values at the same time)


Software

• Wide measurement range (V, A, W, Wh, cosθ, Electric change, Hz, CO2 expelled volume)
• Easy to use with multi-consent (Plug & Play)
• Electric change calculation and expelled volume of CO2 computation available
• GUI Program Gratuitous Supports

> Applications
Pneumatics

Public Institution & Consumption Union


Hydraulics

Energy Saving Educational Program


Home Appliance Store
Electronic Product Line & Service Center

www.ed.co.kr 168

Part4 test measurement_��.indd 168 2014-02-25 �� 11:13:25


• Meter

HPM-100A Standby Power Meter

> SPECIFICATION
• Current Measurement Range
» AC 100uA ~ 15A
› AC: 100uA ~ 5mA ±(0.5%rdg + 3d)
› AC: 5mA ~ 15A ±(0.3%rdg + 3d)
• Voltage Measurement Range
» Voltage: AC 90V ~ 250V ±(0.3%rdg + 3d)
• Wattage Measurement Range
» AC 0.009W ~ 2,500W(PF 1.0)
› Active Power: 0.009W ~ 0.45W ±(0.5%rdg + 3d)
› Active Power: 0.45W ~ 2,500W ±(0.4%rdg + 2d)
• Power Factor: ±0.001 ~ 1, ±(0.5%rdg + 3d)
• Frequency: 40Hz ~ 1,000Hz, ±(0.5%rdg + 3d)
• Dimension & Weight :115(W) x 200(H) x 45(D)mm & 650g

• GUI Program (PC Version)

» Manual Window » Analyzer TAP » Voltage & Current Graph TAP

» Watt & Wh Graph TAP » PF & Frequency Graph TAP » CO & COST Graph TAP

ACCESSORIES

• GUI PROGRAM - CD
• STANDARD LOAD
• BAG
• RS232 TO USB CABLE

169 Part4 Test & Measurement

Part4 test measurement_��.indd 169 2014-02-25 �� 11:13:25


• Power Supply

HPM-300A Handy Power Meter

Electronics
Embedded

Electricals
• Watt Meter for trend of 21 Century and new generation should be able to measure consumption
power, standby power, AC and DC and be easy to use and has reasonable price. HPM-300A shows 4
factors’(Volt, Current, Watt, and Frequency) measurement value on the wide LCD display at the same

Renewable
time and is able to measure 11 factors such as Cosθ, Wh and etc. With Clamp Sensor it is able to

energy &
measure up to 1000A and also able to measure 3 Phases power by using Frondel’s 2P & 3P system

LED
AC Load Wire Measurement

Communication
IT/
Measurement
Test&
Automation

Intelligent
Robot/
Mechatronics
> FEATURES
• Consumption / Standby Power Measurement (AC / DC 1mW ~ 220kW)
• Lithium Ion Rechargeable Battery
• Load Wire Supplied
• Holster Supplied
• GUI Program Gratuitous Supports
Simulation
Software

> SPECIFICATION
• Current Measurement Range • Voltage Measurement Range
» AC 500uA ~ 15A » Voltage: AC 10V ~ 500V ±(0.3%rdg + 2d)
› Current: 500uA ~ 5mA ±(0.5%rdg + 3d) » Voltage: DC 1V ~ 1000V
› Current: 5mA ~ 10A ±(0.3%rdg + 2d) › Voltage: 1V ~ 10V ±(1.0%rdg + 4d)
› Current: 10A ~ 15A ±(0.4%rdg + 2d) › Voltage: 10V ~ 500V ±(0.3%rdg + 2d)
› Clamp Sensor: AC 5A ~ 1,000A ±(3.0%rdg + 4d) › Voltage: 500V ~ 1000V ±(0.5%rdg + 3d)
Pneumatics
Hydraulics

» DC 1mA ~ 15A
› Current: 1mA ~ 20mA ±(1.0%rdg + 4d)
› Current: 20mA ~ 15A ±(0.5%rdg + 3d)
› Clamp Sensor: DC 5A ~ 1,000A ±(3.0%rdg + 4d)

www.ed.co.kr 170

Part4 test measurement_��.indd 170 2014-02-25 �� 11:13:25


• Meter

HPM-300A Handy Power Meter

> SPECIFICATION
• Wattage Measurement Range
» AC 0.005W ~ 7,500W
› Active Power: 0.005W ~ 0.1W ±(1.0%rdg + 4d)
› Active Power: 0.1W ~ 5,000W ±(0.4%rdg + 2d)
› Active Power: 5,000W ~ 7,500W ±(0.5%rdg + 3d)
» DC 0.001W ~ 15kW
› Active Power: 0.002W ~ 0.2W ±(2.0%rdg + 4d)\
› Active Power: 0.2W ~ 5,000W ±(1.0%rdg + 4d)
› Active Power: 5,000W ~ 15kW ±(0.8%rdg + 3d)
• Power Factor : ±0.001 ~ 1, ±(0.5%rdg + 3d)
• Frequency Measurement Range
» Frequency: 20Hz ~ 1,000Hz, ±(0.5%rdg + 3d)
• Dimension & Weight
» HPM-300A: 100(W) x 200(H) x 45(D)mm &600g
» Clamp Sensor (CA-1000D): 100(W) x 244(H) x 40(D)mm &490g

• GUI Program (PC Version)

» Manual Window » Analyzer TAP » Voltage & Current Graph TAP

» Watt & Wh Graph TAP » PF & Frequency Graph TAP » CO & COST Graph TAP

ACCESSORIES OPTIONS

• GUI PROGRAM - CD
• AC Load Wire • CA-1000D(AC/DC 1A ~ 800A) + Test Probe set
• Lead Wire • DC Load Wire
• Adaptor • RS232 TO USB CABLE

171 Part4 Test & Measurement

Part4 test measurement_��.indd 171 2014-02-25 �� 11:13:25


• Power Supply

ED-333T 180W 3-MODE TRACKING DC POWER SUPPLY

Electronics
Embedded

Electricals
• 3-Mode(Independent, Parallel, Series Tracking)
• 0~60V DC(3A), 0~30V DC(6A) & Fixed 5V(3A)
• Adjustable voltage limit

Renewable
• Overload protection & overvoltage protection

energy &
LED
Communication
IT/
Measurement
Test&
Automation

Intelligent
Robot/
Mechatronics
> SPECIFICATION
• Output Mode : Independent, Tracking(Parallel, Series) • Indicator
• Output Voltage/Current » (Voltage) : 2 Digital Voltmeter & L.V(Limiting Voltage)
» (Current) : 2 Digital Ammeter & C.C(Constant Current)
MODE OUTPUTVOLTAGE OUTPUT CURRENT • Protection
Independent 0~30V Dual(Output) 0~3A Dual(Output) » Overload Protection
Tracking 0~±30V 0~±3A » Overvoltage Protection
Parallel 0~30V 0~6A • Operating Temperature : 0~45˚C, Below 85% R.H.
Simulation

0~60V 0~3A • Input Voltage : AC 220V, 50/60Hz


Software

Series
Fixed Output 5V 3A • Dimension : 325(W) x 145(H) x 290(D)mm
• Weight : 12kg

• Ripple Rejection : Not Exceeding 0.02%+1.5mV(Series


Mode : 0.02 %+3mV) ACCESSORIES
• Regulation(Line) : Not Exceeding 0.03%+1.5mV • Output Cord : 1set
(Load) : Not Exceeding 0.03%+3mV • AC Power Cord : 1ea
• Tracking Mode Series Regulation : Below 300mV
Pneumatics

• Instruction Manual : 1ea


Hydraulics

• Tracking Error : Not Exceeding 0.5%+10mV

www.ed.co.kr 172