TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 1 of 12

1. Date of Erection : Date of Energization :

2. Equipment Details :

LOA No :
Make :
Type :
Sl. No. : Rph : Y ph : B ph :
Mfg Year :

3.a. Feeder Name :

3.b. General Checks :

1 Equipment is cleaned and free from Dust / Dirt foreign materials etc.
2 Equipment is free from all visible defects on physical inspection
3 Check CT tank has been provided with earthing (Dead Tank CT’s)
4 Check that CT junction box is earthed
5 All Nuts and Bolts are tightened correctly as per specified torque
6 Check tightness of terminal connector
7 All fittings as per out line general arrangement drawing
8 Check primary polarity of CT’s erected as per relevant drawing
9 Check hermetically sealing is intact
10 Check the oil level and leakage through any joints / sec. terminals
11 Check oil drain valve is properly closed and locked
12 Oil level on top chamber gauge glass
13 Ensure interpole cabling is completed and check the continuity
14 Check the IR value of secondary cable
15 Check external cabling from junction box to relay / control panel completed
16 Ensure unused secondary cores if any has been shorted
17 Check start point has been formed properly and grounded at one end only

4. Rated Data & Duty :

Core Ratio Class Burden KVP I Max (mA) Protection / Metering


Winding – 1
Winding – 2
Winding – 3
Winding – 4
Winding – 5

Test Performed by Witnessed by Witnessed by


Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date
TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 2 of 12

5. Insulation Resistance Measurement : Using _______ Megger

Make : Range : Sl.No. Calib due date :

Core R ph Y ph B ph
Primary to Earth
Primary to Sec. Core – 1
Primary to Sec. Core – 2
Primary to Sec. Core – 3
Primary to Sec. Core – 4
Primary to Sec. Core – 5

5.1. Insulation Resistance Measurement : Using _______ Megger

Make : Range : Sl.No. Calib due date :

Core R ph Y ph B ph
Sec. Core – 1 to Earth
Sec. Core – 2 to Earth
Sec. Core – 3 to Earth
Sec. Core – 4 to Earth
Sec. Core – 5 to Earth
Sec. Core – 1 to Sec. Core-2
Sec. Core – 1 to Sec. Core-3
Sec. Core – 1 to Sec. Core-4
Sec. Core – 1 to Sec. Core-5
Sec. Core – 2 to Sec. Core-3
Sec. Core – 2 to Sec. Core-4
Sec. Core – 2 to Sec. Core-5
Sec. Core – 3 to Sec. Core-4
Sec. Core – 3 to Sec. Core-5
Sec. Core – 4 to Sec. Core-5

Test Performed by Witnessed by Witnessed by


Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date
TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 3 of 12

6. Continuity Test :
Continuity checks between terminal : OK / Not OK

Core Between R ph Y ph B ph
Terminal
Core – 1 1S1-1S2
1S1-1S3
1S1-1S4
Core – 2 2S1-2S2
2S1-2S3
2S1-2S4
Core – 3 3S1-3S2
3S1-3S3
3S1-3S4
Core – 4 4S1-4S2
4S1-4S3
4S1-4S4
Core – 5 5S1-5S2
5S1-5S3
5S1-5S4

Note : incase of terminal are not provided please write “NA” (Not Applicable)

7. Check IR value of primary winding between P1 and Power factor terminal in


secondary terminal box and finally ensure earthing link of power factor
terminal is in position :

Using ______ Megger Make : Range : Sl. No. Calib due date :

R ph Y ph B ph

Test Performed by Witnessed by Witnessed by


Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date
TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 4 of 12

8. Secondary Winding Resistance : ( Values in OHM ) (Used Equipment Details)

Make : Range : Sl. No. Calib due date :


Core Between R ph Y ph B ph
Terminal Factory Site Factory Site Factory Site
Core – 1 1S1-1S2
1S1-1S3
1S1-1S4
Core – 2 2S1-2S2
2S1-2S3
2S1-2S4
Core – 3 3S1-3S2
3S1-3S3
3S1-3S4
Core – 4 4S1-4S2
4S1-4S3
4S1-4S4
Core – 5 5S1-5S2
5S1-5S3
5S1-5S4

Factory Test Report Ref No :


9. Polarity Test : Used with 1.5 Volt DC Supply
(Connect Positive battery Terminal P1 side and Negative battery Terminal P2 side)
Core Check Between R ph Y ph B ph
Terminal
Core – 1 1S1(+ve) - 1S2 (-ve)
1S1(+ve) - 1S3 (-ve)
1S1(+ve) - 1S4 (-ve)
Core – 2 2S1(+ve) - 2S2 (-ve)
2S1(+ve) - 2S3 (-ve)
2S1(+ve) - 2S4 (-ve)
Core – 3 3S1(+ve) - 3S2 (-ve)
3S1(+ve) - 3S3 (-ve)
3S1(+ve) - 3S4 (-ve)
Core – 4 4S1(+ve) - 4S2 (-ve)
4S1(+ve) - 4S3 (-ve)
4S1(+ve) - 4S4 (-ve)
Core – 5 5S1(+ve) - 5S2 (-ve)
5S1(+ve) - 5S3 (-ve)
5S1(+ve) - 5S4 (-ve)
Note : incase of terminal are not provided please write “NA” (Not Applicable)
Test Performed by Witnessed by Witnessed by
Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date
TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 5 of 12

10. Tan Delta and Capacitance Measurement Test :


Used with test Equipment Details :

Make : Range : Sl. No. : Calibration Due Date :

Voltage Capacitance (Measured Value) Remarks


In KV R ph Y ph B ph
Factory Site Factory Site Factory Site
2
10

Voltage Tan Delta (Measured Value) Remarks


In KV R ph Y ph B ph
Factory Site Factory Site Factory Site
2
10

11. Current Ratio Test :


Primary Injection Through Primary Injection Kit at Primary Terminal P1-P2 & Measure Current on the
Secondary Terminals
Primary Side : Make : Range : Sl. No. :
Sec. Side : Make : Range : Sl. No. :
R ph – Ratio Test
Core Primary Current Secondary Theoretical Actual % of
% Actual Current in A Ratio Ratio Error
Core – 1 20%
1S1-1S2 40%
80%
Core – 2 20%
2S1-2S2 40%
80%
Core – 3 20%
3S1-3S2 40%
80%
Core – 4 20%
4S1-4S2 40%
80%
Core – 5 20%
5S1-5S2 40%
80%

Test Performed by Witnessed by Witnessed by


Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date
TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 6 of 12

Core – 1 20%
1S1-1S3 40%
80%
Core – 2 20%
2S1-2S3 40%
80%
Core – 3 20%
3S1-3S3 40%
80%
Core – 4 20%
4S1-4S3 40%
80%
Core – 5 20%
5S1-5S3 40%
80%

Core Primary Current Secondary Theoretical Actual % of


% Actual Current in A Ratio Ratio Error
Core – 1 20%
1S1-1S4 40%
80%
Core – 2 20%
2S1-2S4 40%
80%
Core – 3 20%
3S1-3S4 40%
80%
Core – 4 20%
4S1-4S4 40%
80%
Core – 5 20%
5S1-5S4 40%
80%

Test Performed by Witnessed by Witnessed by


Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date
TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 7 of 12

Y ph – Ratio Test

Core Primary Current Secondary Theoretical Actual % of


% Actual Current in A Ratio Ratio Error
Core – 1 20%
1S1-1S2 40%
80%
Core – 2 20%
2S1-2S2 40%
80%
Core – 3 20%
3S1-3S2 40%
80%
Core – 4 20%
4S1-4S2 40%
80%
Core – 5 20%
5S1-5S2 40%
80%

Core Primary Current Secondary Theoretical Actual % of


% Actual Current in A Ratio Ratio Error
Core – 1 20%
1S1-1S3 40%
80%
Core – 2 20%
2S1-2S3 40%
80%
Core – 3 20%
3S1-3S3 40%
80%
Core – 4 20%
4S1-4S3 40%
80%
Core – 5 20%
5S1-5S3 40%

Test Performed by Witnessed by Witnessed by


Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date
TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 8 of 12

80%

Core – 1 20%
1S1-1S4 40%
80%
Core – 2 20%
2S1-2S4 40%
80%
Core – 3 20%
3S1-3S4 40%
80%
Core – 4 20%
4S1-4S4 40%
80%
Core – 5 20%
5S1-5S4 40%
80%

B ph – Ratio Test

Core Primary Current Secondary Theoretical Actual % of


% Actual Current in A Ratio Ratio Error
Core – 1 20%
1S1-1S2 40%
80%
Core – 2 20%
2S1-2S2 40%
80%
Core – 3 20%
3S1-3S2 40%
80%
Core – 4 20%
4S1-4S2 40%
80%
Core – 5 20%
5S1-5S2 40%
80%

Test Performed by Witnessed by Witnessed by


Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date
TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 9 of 12

Core – 1 20%
1S1-1S3 40%
80%
Core – 2 20%
2S1-2S3 40%
80%
Core – 3 20%
3S1-3S3 40%
80%
Core – 4 20%
4S1-4S3 40%
80%
Core – 5 20%
5S1-5S3 40%
80%

Core Primary Current Secondary Theoretical Actual % of


% Actual Current in A Ratio Ratio Error
Core – 1 20%
1S1-1S4 40%
80%
Core – 2 20%
2S1-2S4 40%
80%
Core – 3 20%
3S1-3S4 40%
80%
Core – 4 20%
4S1-4S4 40%
80%
Core – 5 20%
5S1-5S4 40%
80%

Test Performed by Witnessed by Witnessed by


Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date
TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 10 of 12

12. Magnetising Curves Performance : Knee Point Voltage (KVP) ________ Volts

12.1.a. R Phase – 1S1-1S2


Voltage Measured Current in (mA)
To be Actual Core-1 Core-2 Core-3 Core-4 Core-5
Applied Voltage 1S1-1S2 2S1-2S2 3S1-3S2 4S1-4S2 5S1-5S2
0.25 x Kvp
0.50 x Kvp
0.75 x Kvp
1.00 x Kvp
1.10 x Kvp

12.1.b. R Phase – 1S1-1S3


Voltage Measured Current in (mA)
To be Actual Core-1 Core-2 Core-3 Core-4 Core-5
Applied Voltage 1S1-1S3 2S1-2S3 3S1-3S3 4S1-4S3 5S1-5S3
0.25 x Kvp
0.50 x Kvp
0.75 x Kvp
1.00 x Kvp
1.10 x Kvp

12.1.c. R Phase – 1S1-1S4


Voltage Measured Current in (mA)
To be Actual Core-1 Core-2 Core-3 Core-4 Core-5
Applied Voltage 1S1-1S4 2S1-2S4 3S1-3S4 4S1-4S4 5S1-5S4
0.25 x Kvp
0.50 x Kvp
0.75 x Kvp
1.00 x Kvp
1.10 x Kvp

12.2.a. B Phase – 1S1-1S2


Voltage Measured Current in (mA)
To be Actual Core-1 Core-2 Core-3 Core-4 Core-5
Applied Voltage 1S1-1S2 2S1-2S2 3S1-3S2 4S1-4S2 5S1-5S2
0.25 x Kvp
0.50 x Kvp
0.75 x Kvp
1.00 x Kvp
Test Performed by Witnessed by Witnessed by
Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date
TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 11 of 12

1.10 x Kvp

12.2.b. B Phase – 1S1-1S3


Voltage Measured Current in (mA)
To be Actual Core-1 Core-2 Core-3 Core-4 Core-5
Applied Voltage 1S1-1S3 2S1-2S3 3S1-3S3 4S1-4S3 5S1-5S3
0.25 x Kvp
0.50 x Kvp
0.75 x Kvp
1.00 x Kvp
1.10 x Kvp

12.2.c. B Phase – 1S1-1S4


Voltage Measured Current in (mA)
To be Actual Core-1 Core-2 Core-3 Core-4 Core-5
Applied Voltage 1S1-1S4 2S1-2S4 3S1-3S4 4S1-4S4 5S1-5S4
0.25 x Kvp
0.50 x Kvp
0.75 x Kvp
1.00 x Kvp
1.10 x Kvp

12.3.a. Y Phase – 1S1-1S2


Voltage Measured Current in (mA)
To be Actual Core-1 Core-2 Core-3 Core-4 Core-5
Applied Voltage 1S1-1S2 2S1-2S2 3S1-3S2 4S1-4S2 5S1-5S2
0.25 x Kvp
0.50 x Kvp
0.75 x Kvp
1.00 x Kvp
1.10 x Kvp

12.3.b. Y Phase – 1S1-1S3


Voltage Measured Current in (mA)
To be Actual Core-1 Core-2 Core-3 Core-4 Core-5
Applied Voltage 1S1-1S3 2S1-2S3 3S1-3S3 4S1-4S3 5S1-5S3
0.25 x Kvp
0.50 x Kvp
0.75 x Kvp
1.00 x Kvp
1.10 x Kvp

Test Performed by Witnessed by Witnessed by


Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date
TEST REPORT FOR CURRENT TRANSFORMER

DOC. No. : VEPL/T&CF/CT/003 / Rev : 0


VOLTECH ENGINEERS PVT. JOB REF NO : VEPL/TR/ /
LTD. DATE : Page No.
Excellent Electrical Service

CLIENT : M/s.
PROJECT : Sheet No 12 of 12

12.3.c. Y Phase – 1S1-1S4

Voltage Measured Current in (mA)


To be Actual Core-1 Core-2 Core-3 Core-4 Core-5
Applied Voltage 1S1-1S4 2S1-2S4 3S1-3S4 4S1-4S4 5S1-5S4
0.25 x Kvp
0.50 x Kvp
0.75 x Kvp
1.00 x Kvp
1.10 x Kvp

Note : the following conditions to be checked :

a. Before Commissioning Tan Delta Test Link Should be Earthed : 


b. CT Secondary Spare Terminal Should be Short & Earthed : 
c. CT Secondary All Terminals Tightness Should be Checked : 

13. Remarks :

Test Performed by Witnessed by Witnessed by


Name : Name Name
Designation : Designation Designation
Signature & Signature & Signature &
Date Date Date