Flexacam c5
Microscope Cameras
User Manual
Contents
User manual For information on the Enersight OSD in To maintain the camera in its original condition
The Flexacam camera can be configured in a stand-alone mode, Enersight Desktop and and to ensure safe operation, the user must
variety of ways in the Leica product range. Enersight Mobile, refer to the website Micro- follow the instructions and warnings contained
You can find information on the USB scope Software Platform Enersight or scan the in these user manuals.
stick together with all relevant user manuals QR code to be directed to Enersight web-page:
in additional languages. Keep this USB
stick in a safe place, where it is available
to the user.
Camera safety and EMC The camera meets the requirements of EU If the instrument is being installed in any other
Our camera has been designed, produced and directives environment than an INDUSTRIAL, it cannot be
tested in compliance with O 2014/35/EU Low voltage directive guaranteed that the equipment does not inter-
fere with other electronic devices.
O EN 61010-1: Safety requirements for elec- O 2014/30/EU EMC directive
trical equipment for measurement, control, INDUSTRIAL environments are part of a sepa-
O 2011/65/EU RoHS directive
and laboratory use - Part 1: General require- rate power network, in most cases supplied by
ments (for microscope) O 2009/125/EC + VO EU 2019/1782 a high- or medium-voltage transformer, dedi-
Ecodesign requirements for energy-rela- cated for the supply of installations feeding
O EN 62368-1: Audio / video, information and ted products only applicable for external manufacturing or similar plants.
communication technology equipment - power supply
Strong electromagnetic fields in the immediate
Part 1: Safety requirements (for optional and carries the CE mark. vicinity of the device can lead to a malfunction
external power supply only)
Intended for indoor use only in all EU member of the screen display.
This End User License Agreement is entered When sending or forwarding the camera to
into by and between Leica Microsystems third parties for any reason, or when returning
("Leica") and you, the end user, as the context the camera to Leica for service or maintenance,
requires, either individually or as an authorized the User should always reset the camera to
representative of the company or organization factory settings.
acquiring and / or using this camera ("User").
Use of network and / or other connectivity
This camer can be used in a network and offers functionality provided by or with this camera
functionality such as automated submission of are at the User´s discretion and risk; specifically,
images to an E-Mail recipient defined by the the User assumes full responsibility for network
User, or copying of images to a SMB file server operation and safety. Leica does not guarantee
selected by the User. Therefore, passwords will any particular network safety standard and
need to be chosen by the User which passwords declines all responsibility, without limitation,
will be stored on the camera in a separate pass- for unauthorized access, security breach, data
word file. Direct access to the password file is loss or corruption, or any financial or legal
denied; passwords are stored with an encryp- consequences thereof.
tion which follows the Advanced Encryption
Standard (AES), with a block and key size of
128 bits.
During any firmware update this password file
will be deleted and the User will need to reenter
the passwords.
Introduction
Your Leica Flexacam is a state-of-the-art brightfield camera with 12 megapixel image resolution. The camera can be easily connected to a variety of
compound and stereo microscopes without additional components. There are various ways to connect the camera with your viewing devices:
Network mode
X Use your camera in network mode by
connecting it to the Ethernet (via adapter) or
by connecting a Wi-Fi dongle.
4 5
HD / 4K monitor
HD / 4K monitor enables you to life stream and
acquire images in a higher resolution.
Handswitch / Footswitch
Various functionals can be assigned to the opti-
onal handswitch / footswitch (such as taking
pictures, white balance, video recording).
Barcode scanner
Barcode scanner or Barcode reader enables you
to assign tags for images and videos.
1. ON / OFF button
2. PC / power supply connection (USB Type-C)
3. Status LED
4. HDMI port for monitor (stand-alone mode)
5. 2× USB port for
– USB thumb drive (for data storage),
– mouse,
– keyboard,
– Wi-Fi dongle or
– USB-to-Ethernet adapter (USB Type-A)
1 2 3 4 5 5
1 1 1 2 3 4 5 6
1. Ethernet connection
2. USB SPEED port (insert USB thumb drive for
data storage here) (stand-alone operation)
3. USB port for
1 2
– USB thumb drive (for data storage),
– mouse,
– keyboard,
– Wi-Fi dongle or
– USB-to-Ethernet adapter (USB Type-A)
3
4. HDMI port for monitor (stand-alone mode)
3
3 5. Connection for handswitch / footswitch
(2.5 mm phone jack)
6. PC / power supply connection (USB Type-C)
7. ON / OFF button
7 6 5 4
Leica tube
2
Flexacam i5 1. Slightly unscrew the set screw (2) and 2. Attach the Flexacam i5 Compound (3) to
Compound remove the tube (1). the microscope stand by inserting the
dovetail (see the underside of the camera)
into the stand support (4).
3. Tighten the set screw (2) firmly without
forcing it.
Leica
compound
microscope
stand
6 7
4. Place the tube (1) onto the 5. Connect the camera via HDMI (6) or USB (7)
Flexacam i5 Compound using the set to your viewing device depending on the
screw (5), which is located on the left side operation mode.
of the camera module.
Leica tube 4
1. Loosen the set screw (1). 4. Place the tube (2) back onto the camera.
2. Remove the tube (2). 5. Tighten the set screw (4) firmly without
Flexacam i5 forcing it.
(Stereo)
3
Leica optics
carrier 1
5 6
2 1
2 1 1 2
1. Use the 4K HDMI cable to connect the HDMI 1. Use the 4K HDMI cable to connect the HDMI 1. Use the 4K HDMI cable to connect the HDMI
port (1) of the Flexacam i5 Compound and port (1) of the Flexacam i5 Stereo and the port (1) of the Flexacam c5 and the HD / 4K
the HD / 4K monitor. HD / 4K monitor. monitor.
2. Use the USB-C / USB-A cable to connect the 2. Use the supplied power supply unit to 2. Use the USB-C / USB-A cable to connect
port (2) of the Flexacam i5 Compound to a connect the Flexacam i5 Stereo port (2) to the port (2) of the Flexacam c5 to a suitable
suitable power socket. a suitable power socket. power socket.
The camera detects the monitor automati- The camera detects the monitor automati-
cally and displays a live image. cally and displays a live image.
Saving data on the Flexacam i5 Compound Saving data on the Flexacam i5 Stereo Saving data on the Flexacam c5
1 2
X To ensure the quickest possible way to store X To ensure the quickest possible way to store X To ensure the quickest possible way to store
data, insert the USB thumb drive with suffici- data, insert the USB thumb drive with suffici- data, insert the USB thumb drive with suffici-
ent free memory in one of the USB ports (1). ent free memory in the USB SPEED port (2) at ent free memory in the USB SPEED port (3) at
the rear side of the Flexacam i5 Stereo. the Flexacam c5.
USB Type-A ports on the Flexacam i5 Compound: USB Type-A ports on the Flexacam c5: 1. Plug in the USB transmitter of the USB mouse
in an unused USB Type-A port (1) on the rear
side of the Flexacam.
1
1
2. After downloading the Enersight Desktop 1. Connect the Flexacam to a USB Type-C port
USB Type-C port on the Flexacam i5 Stereo:
software, follow the instructions for instal- (1) of the computer using a USB-C / USB-A
ling the software. cable.
The camera is powered by the computer via
the USB-C / USB-A cable.
Stand-alone mode
ON / OFF button on the Flexacam i5 Compound: ON / OFF button on the Flexacam c5: The camera automatically detects the
HD / 4K monitor and run Enersight OSD.
1
PC mode
1. Set the ON / OFF button (1) to "ON" to
1 switch on the Flexacam.
The camera is ready to use.
ON / OFF button on the Flexacam i5 Stereo: 2. Start the Enersight Desktop software.
Ensure the following points:
1 O The camera can receive light For additional information on Ener-
from the microscope sight Desktop, refer to the website
Microscope Software Platform
O The camera is connected Enersight.
to a HD / 4K monitor and
the power supply or to the Network mode
compound microscope (for
1. Set the ON / OFF button (1) to "ON" to
Flexacam i5 Compound only)
switch on the Flexacam.
X Set the ON / OFF button (1) to "ON" to
2. Refer page 39 to page 41 for more
switch on the Flexacam.
guidance.
For information on setting up and The resolution on the connected HDMI port on the Flexacam i5 Stereo:
switching on the Flexacam in PC HD/4K monitor is always a 16:9
mode, refer to chapters: 1
format and independent of the
O "PC Mode: Connecting a computer resolution.
Computer, Installing Software",
page 31 Additionally the OSD functionality is
turned off on the HDMI monitor.
O "„Switching on the Flexacam“"
subchapter "PC mode",
page 33 Connecting the HD/4K monitor
X Use the HDMI cable to connect the HDMI port on the Flexacam c5:
Additional parallel use of an HD / 4K HDMI port (1) of the Flexacam and the
monitor HD/4K monitor.
HDMI port on the Flexacam i5 Compound:
General notes
When connected to a computer, the 1
1
microscope image is always shown
in the preview window of Ener-
sight Desktop. To display a 4K live
image at up to 60 fps in PC mode,
please connect an optional 4K and
HD-capable monitor to the HDMI
port of the camera.
For information on switching on For using the Enersight Mobile App with your
Flexacam, please download it via Google Play
the Flexacam in network mode,
or App Store.
refer to chapter "„Switching on the
Flexacam“" subchapter "Network
mode", page 33
Connecting to the network USB ports on the Flexacam i5 Compound: USB ports and Ethernet port on the Flexacam c5:
You can connect to the network with the Wi-Fi
dongle or with the USB-to-Ethernet adapter. 2
Connection to the mobile device To connect your mobile device (smartphone Your Flexacam is connected to a network –
First connection: or tablet), you can choose between 2 different client mode:
modes:
1. Run the Flexacam in a stand-alone mode 1. Activate this mode on Enersight OSD as
(page 35). O Flexacam serves as an Access Point (AP).
follows:
O Flexacam is connected to a network – client
2. Go to the network settings in the Enersight mode: Settings Ú Network Ú Client-Mode
OSD software as follows:
Enersight OSD Ú Settings Ú Network Your Flexacam serves as an Access Point 2. Select a network you would like to connect.
(AP):
3. Enter the network password.
3. Activate WebSocket and create the certifi-
1. Activate this mode on Enersight OSD as 4. Connect your mobile device to the same
cate.
follows: network.
4. Restart the Flexacam.
Settings Ú Network Ú AP-Mode In “Settings“ on the Enersight OSD software
Perform step 4. only once during the you will see an IP adress of your camera.
initial setup. You will see the credentials of this AP (SSID,
password, etc.) and the IP address of the
5. Download Enersight Mobile App on your device.
smartphone or tablet from Google Play or
App Store (see page 39). 2. Connect your mobile device to this AP (via
Settings on your smartphone / tablet).
To switch from one mode to another, 4. Click on the latest IP address in the history
the Wi-Fi button on the Enersight list.
OSD must be disabled. The Flexacam is connected.
RECOVERY MODE
RECOVERY MODE
Dimensions in mm
68
51
6
Ø44.5 59
197
132
117
101
Dimensions in mm
49.5
38
9
52
133.1
118.7
Dimensions in mm
54.7 57.3
66
7
~2.6
1-32UN Ø37
Ø30 74
CONNECT
WITH US!
www.leica-microsystems.com