Section C Electrics Section C 50-5 Calibration - LMI System ‘The LED indications described are in addition to the green power-on LED G at the bottom of the display, which remains ‘on whenever power is supplied to the display unit ‘The display unit must be calibrated by setting the "100%" point using a known load and boom extension. A WARNING During the following procedure, do not raise the lond more than 600mm above ground level otherwise the machine may be able to tip forward at a dangerous angle. Keep all personnel clear of the front and rear of the machine. Safe Load Indicator & Load Moment Indicator 50-5 1 Park the machine on firm level ground. 2 Turn the starter key to the OFF position. Press and hold display button A. Start the engine with button A held dow, Hold the button for approximately 30 seconds after the engine has started. All display LEDs will ituminate during this time, Note: i the button is release during this time, the entire process must be repeated. After approximately 30 seconds, the display will show ‘the red LED E only and the alarm will emit short intermittent bleeps. 3 Release botton A. 4 With the boom fully retracted, pick up a load between 1800 kg and 2000 kg. Use either pallet forks loaded with a test weight, or a bucket filed with a high density material 5 Slowly extend the boom. Keep the load close to the ‘ground until the machine is balanced about the front, ‘axle with the rear wheels offthe ground. Note: Ifthe following actions are not completed within ative minute period, the display will automatically leave the calibration mode and the memory will revert to the previous settings. Ifthe transducer signal is out of range, the display will indicate the appropriate error code. Calibration cannot continue unt the fault Is rectified 6 Press and release the display button A. The display will change to show the amber LED D and red LED E only. 7 Lower the load to the ground and measure the distance the boom is extended (in milimetres) B Refer to the correct load chart for the machine (this section). 9 Read up from the extension figure obtained at step 7 (example line X) tothe tipping line AA. 10 Read horizontally (example line Y) to the maximum ‘working lit fine BB, 41. Read down tothe horizontal axis (example ine Z) to gat the dimension for the boom extension (maximum working limi) 12. Draw a mark on the boom at the dimension obtained above. Raise and retract the boom to the mark drawn ‘on the boom. 13 Press and release the display button. The display will revert to normal operation. The setting of the 100% pposition is now complete. ‘9908/8800 issue? Section C Electrics Section C 50-4 Safe Load Indicator & Load Moment Indicator 50-4 LMI Chart - 520-50 1200 1400 1600 0 200 400-600. BOD.-« 1000 1200 1400 1600 1800 B venaraez0 Tevet

You might also like