Cable Type FT-YPV

You might also like

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 3

China Partner Solar Co.

, Ltd
11D,WUHUA BUILDING,XINCHENG, WENZHOU,ZHEJIANG,CHINA
Tel: +86 0577 88952798 Fax: +86 0577 88952908

Date:
Ref.: NO.

SPECIFICATION OF CABLE TYPE:FT-YPV


FOR
PHOTOVOLTAIC POWER SYSTEMS

Please return one copy with


Your signature if you can approve

APPROVED BY:

APPROVED CHECKED ENGINEERING


Specification of cable

1. Scope

This specification applies to TUV approval cable for photovoltaic.

2. Reference Standard

2Pfg1169/10.04

3. Approval NO.

R 50096124

4. Rating

Rated temperature:-40 ~ +85℃

Rated Voltage:DC 1000V


5. Product name

Type: FT-YPV/FT-YPV cable

6. Construction

Items Specifications
Size 2.5m㎡ 4.0m㎡
Material Soft-annealed copper(Tin plated)
Conductor
Composition 50/0.25㎜ 50/0.30㎜
Diameter 2.1㎜ 2.6㎜
Material PE/XLPE
Normal Thickness 0.7㎜ 0.8㎜
Insulation Min. Average Thickness 0.65㎜ 0.72㎜
Min. Thickness 0.6㎜ 0.65㎜
Diameter 3.5 4.2
Material PE/XLPE
Normal Thickness 0.95㎜ 1.0㎜
Sheath Min. Average Thickness 0.86㎜ 0.9㎜
Min. Thickness 0.75㎜ 0.8㎜
Diameter 5.4㎜ 6.2㎜
2Pfg1169 Cable for Photovoltaic System approved by TUV
Marketing
※… Size

Insulation Conductor
Sheath
7. Characteristics
Items Specifications Test methods
Conductor resistance 2.5SQ... Max 8.21Ω/km
4.0SQ... Max 5.09Ω/km
Dielectric Voltage(in water) 3000V/15min
Insulation resistance(20℃) Min 0.01MΩ·km
Mechanical test without ageing (Insulation)
Tensile strength: Min 12.5MPa
Elongation at break: Min 125%
(Sheath)
Tensile strength: Min 12.5MPa
Elongation at break: Min 125%
Mechanical test without ageing (Insulation)
(100±2℃/168hours) Tensile strength: variation Min-30%
Elongation at break: Min 125% and
2Pfg1169/10.04
variation ±30%
Mechanical test without ageing (Sheath)
(110±2℃/168hours) Tensile strength: variation Min-30%
Elongation at break: Min 125% and
variation ±30%
Hot set test for insulation Elongation: Max 175%(after 200℃/15min)
Elongation: Max 15%(after cooling)
Flame resistance Distance between the top support and the
onset of charring is more than 50mm, and less
than 540mm.
Cold bend test(-40±2℃/16h) The cable shall show no sign of cracking
Cold Impact test(-40±2℃/16h) The cable shall show no sign of cracking
Cold Elongation test(-40±2℃/16h) Elongation: Min 30%
UV resistance test ※1 Tensile strength and Elongation at break ISO4892-2
variation ±30%
8、manufacturer:
Qinhuangdao Suole Electron Co. Ltd.

※ 1 Irradiance:550W/㎡(Wavelength 290~800mm)、BP temperature:63±3℃、
Exposure hours:500±5hours、Spray cycle(18min every 102min)