Pub.

EC-0105
"A" SERIES PISTON PUMPS
Variable Displacement-Single,Double,
Variable / Fixed Double
PISTON
PUMPS
A
Up to 28 MPa (4060 PSI), 145 cm3/rev (8.85 CU.IN./rev)

Control Piston
Spool
Drain Port

Pressure Adj. Screw

Pivot
Flow Adj. Screw

Shaft

OUT

IN

Yoke

Port Plate Swash Plate

Cylinder Block Slipper Retainer

Piston Ass'y Spring, Yoke Return

Features

High efficiency Low noise level


Under the conditions of pressure 16 MPa (2320 PSI) and In the "A16" pump, the noise level is as low as 57.3 dB(A)
speed 1800 r/min, the volumetric efficiency is over 98% [at the full cut-off pressure 21 MPa (3050 PSI) with speed
and the overall efficiency is over 90%. 1500 r/min one metre (3.3 ft.) horizontally away from pump
head cover.]

"A16" type performance characteristics


% N=1800 r/min
100
Volumetric Efficiency
"A16" type noise level characteristics
HP kW Overall Efficiency L /min
16 12 80 32 U.S.GPM dB(A) N=1500 r/min
Output Flow 8 80
28
7
12 9 60 24
6 70
Input Power

Output Flow

20
5
Noise Level
Efficiency

8 6 16 4 60
Input Power Full Cut-off
12 3
4 3 8 2 50
4 1
0 0
0 0 40
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21

0 500 1000 1500 2000 2500 3000 PSI 0 500 1000 1500 2000 2500 3000 PSI
Pressure Pressure

Accomplishment of energy-saving Low heat generation


Because the overall efficiency is high and the cut-off Because of small power loss, it is possible to reduce the rise
characteristics is sharp, thus the input power may be saved. in oil temperature. Accordingly, capacity of a reservoir can
be reduced.

No.1
"A" Series Piston Pumps
Single, Double, Variable / Fixed Double PISTON
Instructions
PUMPS

Instructions
1. Hydraulic Fluids 8. Drain Piping
Use petroleum based oils such as anti-wear type hydraulic oils Install drain piping according to the chart and ensure that
or R & O (Rust and Oxidation inhibitor) type hydraulic oils pressure within the pump housing should be maintained at a
equivalent to ISO VG-32 or 46. The recommended viscosity normal pressure of less than 0.1 MPa (14.5 PSI) and surge
range is from 20 to 400 mm2/s (98 to 1800 SSU) and pressure of less than 0.5 MPa (72.5 PSI).
temperature range is from 0 to 60° (32 to 140°F), both of which Length of piping should be less than 1 m (3.3 ft.), and the pipe
have to be satisfied for the use of the above hydraulic oils. end should be submerged in oil.

2. Control of Contamination [Recommended Drain Piping Size]


Due caution must be paid to maintaining control over
contamination of the operating oil which can otherwise lead (Single Pump & Variable/Fixed Double Pump)
to breakdowns and shorten the life of the unit. Please maintain
the degree of contamination within NAS Grade 10. Inside Dia.
Model Fitting Size
of Pipe
The suction port must be equipped with at least a 100 μm (150
mesh) reservoir type filter and the return line must have a line A10,
3/8 [Inside Dia. 8.5 mm
type filter of under 10 μm. A16, A16R1
(.33 in.) or more]
10 mm (.39 in.)
A22, A22R1

3. Mounting 1/2 [Inside Dia. 12 mm


A37, A37R1 12 mm (.47 in.)
(.47 in.) or more]
When installing the pump the filling port should be positioned
A56, A56R1
upwards.
A70, A70R∗ 3/4 [Inside Dia. 16 mm
19 mm (.75 in.)
A90, A90R∗ (.63 in.) or more]
4. Alignment of Shaft A145,A145R∗
Employ a flexible coupling whenever possible, and avoid any
stress from bending or thrust. (Double Pump)
Maximum permissible misalignment is less than 0.1 mm (.004
inches) TIR and maximum permissible misangular is Refer to the suitable single pump as shown below.
less than 0.2°.

5. Suction Pressure Ex. A16 37


Permissible suction pressure at inlet port of the pump is
between -16.7 and +50 kPa (5 in.Hg Vacuum and 7 PSIG). Inboard Pump
For piping to the suction port, use the pipes of the same
Same as "A37"
diametre as that of the specified pipe flange to be used. Make
sure that the height of the pump suction port is within one
metre (3.3 ft) from the oil level in the reservoir. Outboard Pump
Same as "A16"
6. Hints on Piping
When using steel pipes for the suction or discharge ports, Fix drain pipe for each side of the pump.
excessive load from the piping to the pump generates exces-
sive noise.
Whenever there is fear of excessive load, please use rubber 9. Bleeding Air
hoses. It may be necessary to bleed air from pump case and outlet
line to remove causes of vibration. An air bleed valve (Model
7. Suction Piping No. ST1004-∗-10∗, Catalogue No.: Pub. EC-3001) is
In case the pump is installed above the oil level, the suction recommended for this purpose.
piping and suction line filter should be located lower than the
pump position to prevent air in the suction line.

No.2
"A" Series Piston Pumps
Single, Double, Variable / Fixed Double PISTON
PUMPS
A
Instructions

10. Starting 11. Setting Discharge Pressure and Delivery


Before first staring, fill pump case with clean operating oil At the time of shipment, the unit has been preset to maximum
via the fill port. delivery and minimum discharge pressure.
In order to avoid air blockage when first starting, adjust the Adjust the preset delivery and pressure to meet your system
control valves so that the discharged oil from the pump is requirements.
returned direct to the tank or the actuator moves in a free load.
Adjustment of Discharge Pressure
Turning the adjustment screw clockwise, increases pressure.
[Volume of Pre-fill Oil Required] Volume adjusted by each full turn of the pressure
(Single Pump) adjustment screw

Model Volume cm3 (in.3) Adjustment Volume


Model Numbers
MPa (PSI)
A10 370 (22.6)
A10-FR01B 2.9 (420)
A16/A22 600 (36.6)
A10-FR01C/H 5.4 (780)
A37/A56 1200 (73.2)
A16/A22/A37/A56-∗-R-01-B 3.5 (510)
A70 2100 (128)
A16/A22/A37/A56-∗-R-01-C 6.5 (940)
A90 2500 (153)
A16/A37/A56-∗-R-01-H 7.9 (1150)
A145 3300 (201)
A70/A90/A145-∗-R01B 2.3 (330)
(Double Pump)
A70/A90/A145-∗-R01C 3.2 (460)
Volume cm3 (in.3)
Model A70/A90/A145-∗-R01H 4.0 (580)
A70/A90/A145-∗-R01K
Outboard Pump Inboard Pump
4.7 (680)
A∗-∗-R-02
A1616 600 (36.6) 650 (40.0)
5.0 (730)
A1622 600 (36.6)
650 (40.0)
A2222 600 (36.6) Adjustment of Delivery
A1637 600 (36.6) Turning the flow adjustment screw clockwise, decreases
1250 (76.3) delivery.
A2237 600 (36.6)
A1656 600 (36.6) The minimum adjustable flow and adjustable volume of
A2256 600 (36.6) 1250 (76.3) each full turn of the delivery adjustment screw
A3756 1200 (73.2)
Adjustable volumre
A1670 600 (36.6) Model with each full turn Minimum adjustment flow
of the adjustment
A2270 600 (36.6) 2180 (133) Numbers screw cm3/rev (cu.in./rev)
A3770 1200 (73.2) cm3/rev (cu.in./rev)

A1690 600 (36.6) A10 1.1 (.067) 2.0 (.122)


A2290 600 (36.6) A16 1.4 (.085) 4.0 (.244)
2580 (157)
A3790 1200 (73.2) A22 2.0 (.122) 6.0 (.366)
A5690 1200 (73.2) A37 2.9 (.177) 10 (.610)
A16145 600 (36.6) A56 3.9 (.238) 12 (.732)
A22145 600 (36.6) A70 4.4 (.268) 30 (1.83)
3380 (206)
A37145 1200 (73.2) A90 4.8 (.293) 56 (3.42)
A56145 1200 (73.2) A145 7.2 (.439) 83 (5.06)

(Variable/Fixed Double Pump)


Model Volume cm3 (in.3)
A16R1/A22R1 650 (40.0)
A37R1/A56R1 1250 (76.3)
A70R1/A70R2 2180 (133)
A90R1/A90R2 2580 (157)
A145R1/A145R2 3380 (206)

No.3
"A" Series Piston Pumps
Single, Double, Variable / Fixed Double PISTON
Control Type
PUMPS
Control Type
Single Pumps
Control Type Graphic Symbols Performance Characteristics Explanation Page

Output Flow
When the system pressure increases and comes close
Pressure
to the preset cut-off pressure, the pump flow decreases
"01" Compensator automatically while maintaining the set pressure as it
6
M
Type
O is.
Pressure

Output Flow

Solenoid-two PL PH This type of control is ideal for an application where the


Pressure SOL SOL output power of the actuator has to be controlled in two
"02" Control "OFF" "ON" 28
different load pressures while keeping the actuator
Type speed nearly constant.
PL PH
M
O
Pressure

It is suitable for a situation where a long unloading


Pressure
Output Flow

time is required and heat generation and noise have


Compensator
to be kept at their lowest levels.
"03" with SOL SOL 36
"OFF" "ON"
Unloading
The pump can be used in combination with the
Type M
O multistage pressure control valve.
Pressure
(S←Input Current i 2 →L)

i1 This is an energy-saving type control which regulates


Proportional i2
the pump flow and load pressure to be at absolute
Output Flow

Electro-
minimum necessary level to operate the actuator. Pump
Hydraulic
"04" Load
flow rate and cut-off pressure are controlled 37
proportional to the input current to the control device
Sensing
M
Pressure on the pump and the input current is regurated by the
Type O

(S←Input Current i 1 →L) specific amplifier.

This type of control has the pressure sensor and tilt


angle sensor in the pump. The pump is used with the
external amplifier.
Proportional
(S←Input Voltage→L)

Flow and pressure can be controlled in proportion to


Electro-
input voltage by only one control valve.
Output Flow

Hydraulic The features has been greatly improved by electrical


"04E" Pressure & feedback of swash plate tilt angle correspond to flow
47
Flow rate and load pressure to control valve.
Control M
Type O Pressure Linearity of input characteristics is excellent and easy
(S←Input Voltage→L) to set.
Hysteresis is lower, repeatability and reproducibility
are fine.

Two-Pressure QH
Output Flow

PH This type of control is suitable for an application like


Two-Flow
QL "Presses" where the changeover from rapid advance to
"05" Control Type PL feed is required just when the pressing (pressurizing)
by System
starts.
Pres. M PL PH
O
Pressure

SOL"OFF"
Two-Pressure QH
Output Flow

Two-Flow SOL"ON" This pump control is suitable for machining found on


QL machine tool, where machining starts after the
"06" Control Type PL

by Solenoid PH
changeover from rapid advance, to feed has been made.
Valve PL PH
M
O
Pressure

No.4
"A" Series Piston Pumps
Single, Double, Variable / Fixed Double PISTON
PUMPS
A
Control Type

Control Type
Single Pumps
Control Type Graphic Symbols Performance Characteristics Explanation Page

The pump is used in combination with the


pilot relief valve or multistage pressure

Output Flow
Pilot Pressure
Control Type control valve. By controlling the pilot
"07" Pressure pressure, the full cut-off pressure can be 58
Compensator
M
O remote-controlled according to your
Pressure requirements.

Pump input power can be controlled in


accordance with the motor output.
Output Flow When the discharge pressure rise, the
output flow decreases corresponding to
Output Flow

Constant Input Power the preset input power.


"09" Power
Control Type The pump can act for function of 2
M
pumps, low-pressure large-flow and
O
high-pressure small-flow. Therefore, the
Pressure motor capacity can be reduced.

Control type "05", "06" and "09" are not shown in this catalogue. Contact us for the details.

Availability of Control Type


Mark " " in the table below refers to standard model.

Single Pumps
Model Geometric Displacement Control Type
Number cm3/rev (cu.in./rev) 01 02 03 04 04E 05 06 07 09
A10 10.0 (.610)
A16 15.8 (.964)
A22 22.2 (1.355)
A37 36.9 (2.25)
A56 56.2 (3.43)
A70 70.0 (4.27)
A90 91.0 (5.55)
A145 145 (8.85)

Double Pump & Variable/Fixed Double Pump


Control Type Graphic Symbols Explanation Page

These double pump consist of two "A"


"01/01" series single pumps combined in tandem
M
Pressure O
and driven by a common shaft.
Fluid delivered from two separate ports can 67
Compensator M
Type O be either supplied to separate or common
circuit according to the usage.

These double pump consist of "A" series


"01"
pumps and PV2R series vane pumps
Pressure
M combined in tandem and driven by a
Compensator O common shaft. 80
+
Fluid delivered from two separate ports can
Fixed Vane
be either supplied to separate or common
Pump
circuit according to the usage.

No.5
"A" Series Piston Pumps
Variable Displacement-Single Pumps
Pressure Compensator Type PISTON
A10 / A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Specifications

Graphic Symbol

M
O

Specifications
Geometric Minimum Operating Pres. Shaft Speed Range Approx. Mass
Displacement Adj. Flow MPa (PSI) r/min kg (lbs.)
Model Numbers
cm3/rev cm3/rev 2 1 Flange Foot
(cu. in. /rev) (cu. in. /rev) Rated Intermittent Max. Min.
Mtg. Mtg.
A10-FR01B-12∗ 5.1 (11.2)
10.0 (.610) 2 (.122) 16 (2320) 21 (3050) 1800 600
A10-FR01C/H-12∗ 8.5 (18.7)
A16-∗-R-01-∗-∗-K-32∗ 15.8 (.964) 4 (.244) 16 (2320) 21 (3050) 1800 600 16.5 (36.4) 18.7 (41.2)
A22-∗-R-01-∗-∗-K-32∗ 22.2 (1.355) 6 (.366) 16 (2320) 16 (2320) 1800 600 16.5 (36.4) 18.7 (41.2)
A37-∗-R-01-∗-∗-K-32∗ 36.9 (2.25) 10 (.610) 16 (2320) 21 (3050) 1800 600 28.0 (61.7) 32.3 (71.2)
A56-∗-R-01-∗-∗-K-32∗ 56.2 (3.43) 12 (.732) 16 (2320) 21 (3050) 1800 600 35.0 (77.2) 39.3 (86.7)
A70-∗R01∗S-60∗ 70.0 (4.27) 30 (1.83) 25 (3630) 28 (4060) 1800 600 58.5 (129) 70.5 (155)
A90-∗R01∗S-60∗ 91.0 (5.55) 56 (3.42) 25 (3630) 28 (4060) 1800 600 72.5 (160) 93 (205)
A145-∗R01∗S-60∗ 145 (8.85) 83 (5.06) 25 (3630) 28 (4060) 1800 600 92.5 (204) 117.5 (259)
1. Whenever setting pressure, make sure the full cut-off pressure never
exceeds the maximum intermittent pressure.

2. Care should be taken in cases of used at a higher pressure than the


rated pressure, because operating terms may be restricted. For example,
if used as per maximum illustrated operating conditions, intermittent
One Cycle Time
time at maximum flow is restricted to under 1/5 of one cycle time and
under 6 seconds simultaneously. Conditions may vary according to the 1/5 of One Cycle
actual working pressure and delivery (inclination angle of the swash (Max. 5s)
plate). Consult factory or Yuken sales representative for further
Pressure

information.
21 MPa (3050 PSI)
{28 MPa (4060 PSI)} ∗1
Max.
Output
Flow

0
20 MPa (2900)
{27 MPa (3920)} ∗1

∗1. Applicable only for "A70/90/145"

No.6
"A" Series Piston Pumps
Pressure Compensator Type PISTON A
A10 / A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Model Number Designation / Pipe Flange Kit
Model Number Designation
A16 -F -R -01 -B -S -K -32 ∗
Series Direction of Control Pres. Adj. Range Port Shaft Design Design
Mounting
Number Rotation Type MPa (PSI) Position Extension Number Std.

A16 B: 1.2 - 7 (170 - 1020)


C: 1.2 - 16 (170 - 2320) 32
(15.8 cm3/rev) H: 1.2 - 21 (170 - 3050) 2
None:
A22 F: Flange Viewed from B: 1.2 - 7 (170 - 1020) Axial Port
01: Pressure 32
(22.2 cm3/rev) Mtg. Shaft End C: 1.2 - 16 (170 - 2320)
Compensator K: 3
Refer to
1 Type Keyed Shaft
A37 L: Foot R: Clockwise S: 32
(36.9 cm3/rev) Mtg. (Normal) B: 1.2 - 7 (170 - 1020) Side Port
C: 1.2 - 16 (170 - 2320)
A56 H: 1.2 - 21 (170 - 3050)
32
(56.2 cm3/rev)

A70 -F R 01 B S -60 ∗
Series Direction of Control Pres. Adj. Range Port Design Design
Mounting
Number Rotation Type MPa (PSI) Position Number Std.

A10
4 B: 1.2 - 7 (170 - 1020)
F: Flange
C: 2.0 - 16 (290 - 2320) 12
(10.0 cm3/rev) Mtg.
H: 2.0 - 21 (290 - 3050)
A70 Viewed from
01: Pressure 60
(70.0 cm3/rev) Shaft End
F: Flange Compensator Refer to 3
1 Type B: 1.2 - 7 (170 - 1020)
A90 Mtg. R: Clockwise C: 1.5 - 16 (220 - 2320)
S: Side Port 60
(91.0 cm3/rev) (Normal) H: 1.8 - 21 (260 - 3050)
L: Foot K: 2.0 - 28 (290 - 4060)
Mtg.
A145
60
(145 cm3/rev)

1. Available to supply pump with anti-clockwise rotation. Consult 4. When A10 pump is used as the foot Mtg., order the Mtg. Bracket kit
Yuken for details. shown below separately. Refer to page 17 for dimensions of the Mtg.
bracket.
2. The axial port is not available to the N.American Design Standard of Note: The mounting bracket kit consists of a mounting bracket, 2 hex.
A37 and A56. bolts and 2 plain washer.

3. Design Standards: None ........... Japanese Standard "JIS" Mtg. Bracket Approx. Mass
80 ............... European Design Standard Kit Numbers kg (lbs.)
90 ............... N. American Design Standard LP-1A-10 2.2 (4.9)

Pipe Flange Kits


Pipe flange kits are available. When ordering, specify the kit number from the table below.
Pipe Flange Kit Numbers
Threaded Connection Socket Welding Butt Welding
Pump Model Name of
Japanese Std. Japanese Std.
Numbers Port Japanese Std. European N. American "JIS" N. American "JIS" N. American
"JIS" Design Std. Design Std. European Design Std. European Design Std.
Design Std. Design Std.
A16-∗-R-01 Suction F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090
A22-∗-R-01 Discharge F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090
A37-∗-R-01 Suction F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
A56-∗-R-01 Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
Suction F5-12-A-10 F5-12-A-1080 F5-12-A-1090 F5-12-B-10 F5-12-B-1090 F5-12-C-10 F5-12-C-1090
A70-∗R01
Discharge F5-08-A-10 F5-08-A-1080 F5-08-A-1090 F5-08-B-10 F5-08-B-1090 F5-08-C-10 F5-08-C-1090
A90-∗R01 Suction F5-16-A-10 F5-16-A-1080 F5-16-A-1090 F5-16-B-10 F5-16-B-1090 F5-16-C-10 F5-16-C-1090
A145-∗R01 Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of
the flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used.
Details of the pipe flange kits are given in the Catalogue No. Pub. EC-3001

No.7
"A" Series Piston Pumps
Pressure Compensator Type PISTON
A10 / A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Response Characteristics

Response Characteristics Change in Accordance with Circuits and Operating Conditions.

Test Circuit and Conditions


Circuit Conditions
Drive Speed : 1500 r/min
Hydraulic Fluid : ISO VG32 oil
Oil Temperature : A10-A56: 50 °C (122 °F) [Viscosity 20 mm2/s (100 SSU)]
A70-A145: 40 °C (104 °F) [Viscosity 32 mm2/s (150 SSU)]

SOL High Pressure Rubber Hose


Model Ruber Hose Size
A10 1/2" × 800 mm (2.6 ft.)
A16
3/4" × 700 mm (2.3 ft.)
A22
A37
3/4" × 2000 mm (6.6 ft.)
A56
A70 3/4" × 3500 mm (11.5 ft.)
M
M 3/4" × 3000 mm (9.8 ft.)
A90
O +
A145
1-1/4" × 2000 mm (6.6 ft.)

Result of Measurement
t1 t2 Full Cut-off
Pressure

Response Time Overshoot Pressure


Pressure ms
PS Model PS
P1
MPa (PSI)
MPa (PSI) t1 t2
2 MPa(290PSI) 2 MPa(290PSI)
P1 A10 21 (3050) 100 75 2.6 (380)
[3 MPa(440PSI)] [3 MPa(440PSI)]
A16 16 (2320) 38 ∗ 59 ∗ 3.6 (520)
P2 P2 A22 16 (2320) 30 ∗ 72 ∗ 5.9 (860)
40 ∗ 78 ∗
Time
A37 16 (2320) 7.8 (1130)
SOL
OFF ON OFF A56 16 (2320) 38 ∗ 88 ∗ 7.6 (1100)
A70 25 (3630) 80 100 7.8 (1130)
Applicable only for "A90/A145" A90 25 (3630) 90 110 7.9 (1150)
A145 25 (3630) 100 150 8.8 (1280)
∗ Response time except A10, A70, A90 and A145 is measured Yoke travel.

No.8
"A" Series Piston Pumps
A10-FR01 PISTON
PUMPS
A
Typical Pump Characteristics

Typical Performance Characteristics of Type "A10" at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)]

Performance Characteristic Curve


% N=1500 r/min % N=1800 r/min
100 100
Volumetric Efficiency Volumetric Efficiency
Efficiency

Efficiency
L /min L /min
80 Overall Efficiency 20 80 Overall Efficiency 20
Output Flow
60 15 U.S.GPM 60 15 U.S.GPM
Output Flow
HP kW 3 HP kW 3

Output Flow

Output Flow
8 40 10
Input Power

8 40

Input Power
10
8 6 2 8 6 2
wer
4 Powe
r 5 4 t Po 5
4 In pu t 1 4 Inpu 1
2 2
0 0 0 0
0 0
0 4 8 12 16 20 21 MPa 0 4 8 12 16 20 21 MPa
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Pressure 3050 PSI Pressure 3050 PSI

Input Power
HP kW N=1500 r/min HP kW N=1800 r/min
8 8 P=MPa (PSI)
10 10
7 7 P= 20 (2900)
P=MPa (PSI)
P= 18 (2610)
8 6 P= 20 (2900) 8 6 P= 16 (2320)
P= 18 (2610)
P= 16 (2320) P= 14 (2030)
Input Power

Input Power

5 5
6 P= 14 (2030) 6 P= 12 (1740)
4 P= 12 (1740) 4 P= 10 (1450)
P= 10 (1450) P= 8 (1160)
4 3 P= 8 (1160) 4 3 P= 6 (870)
P= 6 (870)
2 P= 4 (580) 2 P= 4 (580)
2 P= 2 (290) 2 P= 2 (290)
1 1
0 0
0 0
0 5 10 15 20 L /min 0 5 10 15 20 L /min

0 1 2 3 4 5 U.S.GPM 0 1 2 3 4 5 U.S.GPM
Output Flow Output Flow

Full Cut-off Power Drain


HP kW in3./min L /min
A10-FR01H
1.4
1.0 1.5
A10-FR01H
Full Cut-off Power

1.2 1800 r/min 80


0.8
1.0
60 1.0
.8 0.6
Drain

A10-FR01C
.6 40 1500 r/min
0.4 A10-FR01C
0.5 1800 r/min
.4 A10-FR01B
1500 r/min
0.2 20
min
.2 800 r/
A10-FR01B 1500,1
0 0
0 0
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21

0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Full Cut-off Pressure 3050 PSI Pressure 3050 PSI

Noise Level [One metre (3.3 ft.) horizontally away from pump head cover]
dB (A) dB (A)
N=1500 r/min N=1800 r/min
70 70
Full Flow
Full Flow
Noise Level

Noise Level

60 60

50 50
Full Cut-off Full Cut-off

40 40
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
3050 PSI 3050 PSI
Pressure Pressure

No.9
"A" Series Piston Pumps
A16-∗-R-01 PISTON
Typical Pump Characteristics
PUMPS

Typical Performance Characteristics of Type "A16" at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)]

Performance Characteristic Curve


% N=1500 r/min % N=1800 r/min
100 100
Volumetric Efficiency Volumetric Efficiency
HP kW L /min
Overall Efficiency Overall Efficiency U.S.GPM
80 16 12 80 32
U.S.GPM Output Flow 8
HP kW L /min 28 7
7
12 9 60 24 12 9 60 24
6 6

Input Power
Output Flow
20 20

Output Flow

Output Flow
5 5
Input Power

Efficiency
Efficiency

8 6 16 4 8 6 16 4
Input Power
12 3 12 3
Input Power
4 3 8 2 4 3 8 2
4 1 4 1
0 0 0 0
0 0 0 0
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21
0 500 1000 1500 2000 2500 3050 PSI 0 500 1000 1500 2000 2500 3050 PSI
Pressure Pressure

Input Power
Example: At a pressure of under 10 MPa (1450 PSI), a flow 20 L /min (5.3 U.S.GPM), and rotation 1500 r/min, the
axial input becomes about 3.7 kW (5 HP) as shown the dotted line in the graph.
HP kW N=1500 r/min HP kW P=MPa(PSI)
N=1800 r/min
16 12 16 12
P=MPa(PSI) P= 20 (2900)
P= 20 (2900) P= 18 (2610)
10 10
P= 18 (2610) P= 16 (2320)
12 12
P= 16 (2320) P= 14 (2030)
8 8
Input Power

Input Power

P= 14 (2030) P= 12 (1740)
P= 12 (1740) P= 10 (1450)
8 6 8 6
P= 10 (1450) P= 8 (1160)
P= 8 (1160) P= 6 (870)
4 4
P= 6 (870) P= 4 (580)
4 4
P= 4 (580) P= 2 (290)
2 2
P= 2 (290) P= 0.7 (100)
0 P= 0.7 (100) 0
0 0
0 5 10 15 20 25 30 L /min 0 5 10 15 20 25 30 L /min

0 1 2 3 4 5 6 7 8 U.S.GPM 0 1 2 3 4 5 6 7 8 U.S.GPM
Output Flow Output Flow

Full Cut-off Power Drain


HP kW L /min
2.0 1.5 3
A16-∗-R-01-H in.3/min Full Cut-off
Full Flow A16-∗-R-01-H
Full Cut-off Power

150
1.5 1800 r/min
1.0 2
1800 r/min 100
1.0
Drain

A16-∗-R-01-C
0.5 1
.5 A16-∗-R-01-C 50
N=1500 r/min
N=1500 r/min
A16-∗-R-01-B
0 A16-∗-R-01-B 0 1500,1800 r/min
0 0
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21
0 500 1000 1500 2000 2500 3050 PSI 0 500 1000 1500 2000 2500 3050 PSI
Full Cut-off Pressure Pressure

Noise Level [One metre (3.3 ft.) horizontally away from pump head cover
dB(A) dB(A) N=1800 r/min
N=1500 r/min
80 80

70 70
Noise Level
Noise Level

Full Flow
Full Flow
60 60

50 50
Full Cut-off Full Cut-off
40 40
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21
0 500 1000 1500 2000 2500 3050 PSI 0 500 1000 1500 2000 2500 3050 PSI
Pressure Pressure

No.10
"A" Series Piston Pumps
A22-∗-R-01 PISTON
PUMPS
A
Typical Pump Characteristics

Typical Performance Characteristics of Type "A22" at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)]

Performance Characteristic Curve

Efficiency
% N=1500 r/min % N=1800 r/min
Efficiency

100 U.S.GPM 100 U.S.GPM


Volumetric Efficiency Volumetric Efficiency
L /min 12 L /min 12
80 Overall Efficiency 40 80 40
Output Flow 10 Output Flow 10
HP kW HP kW
16

Output Flow
16

Output Flow
12 60 30 8 12 60 30 8
Overall Efficiency
10 10
Input Power

Input Power
12 6 12 6
8 20 8 20
8 6 4 8 6 4
Input Power Input Power
4 10 4 10
4 2 4 2
2 2
0 0 0 0 0
0 0 0
0 4 8 12 16 MPa 0 4 8 12 16 MPa

0 500 1000 1500 2000 2320 PSI 0 500 1000 1500 2000 2320 PSI
Pressure Pressure

Input Power
Example: At a pressure of under 10 MPa (1450 PSI), a flow 30 L /min (7.9 U.S.GPM), and rotation 1500 r/min, the
axial input becomes about 5.4 kW (7.2 HP) as shown the dotted line in the graph.
HP HP
14 kW N=1500 r/min 14 kW N=1800 r/min
10 10
P=MPa(PSI) P= 14 (2030)
12 12
P= 14 (2030) P= 12 (1740)
8 8
10 P= 12 (1740) 10 P= 10 (1450)
P= 10 (1450)
P= 8 (1160)
Input Power

Input Power

8 6 8 6
P= 8 (1160)
P= 6 (870)
6 P= 6 (870) 6
4 4 P= 4 (580)
P= 4 (580)
4 4
P= 2 (290) P= 2 (290)
2 2
2 P= 1 (145) 2 P= 1 (145)

0 0 P=MPa(PSI)
0 0
0 10 20 30 40 50 L /min 0 10 20 30 40 50 L /min

0 2 4 6 8 10 12 13 U.S.GPM 0 2 4 6 8 10 12 13 U.S.GPM
Output Flow Output Flow

Full Cut-off Power Drain


HP kW L /min
2.0 1.5 3
in.3/min 1800 r/min
A22-∗-R-01-C 150 Full Cut-off
Full Cut-off Power

1.5 A22-∗-R-01-C
1.0 2
Drain

100
1.0 1800 r/min
N=1500 r/min
0.5 1
50 A22-∗-R-01-B
.5
N=1500 r/min 1500,1800 r/min

0 A22-∗-R-01-B 0
Full Flow
0 0
0 4 8 12 16 MPa 0 4 8 12 16 MPa

0 500 1000 1500 2000 PSI 0 500 1000 1500 2000 PSI
Full Cut-off Pressure 2320 Pressure 2320

Noise Level [One metre (3.3 ft.) horizontally away from pump head cover]
dB(A) N=1500 r/min dB(A) N=1800 r/min
80 80
Noise Level

Noise Level

70 70
Full Flow Full Flow
60 60

Full Cut-off Full Cut-off


50 50
0 2 4 6 8 10 12 14 MPa 0 2 4 6 8 10 12 14 MPa

0 500 1000 1500 2030 PSI 0 500 1000 1500 2030 PSI
Pressure Pressure

No.11
"A" Series Piston Pumps
A37-∗-R-01 PISTON
Typical Pump Characteristics
PUMPS

Typical Performance Characteristics of Type "A37" at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)]

Performance Characteristic Curve


% N=1500 r/min % N=1800 r/min
100 100

Efficiency
Efficiency

Volumetric Efficiency Volumetric Efficiency


L /min
Overall Efficiency Overall Efficiency U.S.GPM
80 80 80 20
U.S.GPM
HP kW L /min HP kW
40 30 60 Output Flow 60 16 40 30 60 Output Flow 60 16

Output Flow

Output Flow
30 12 30 12
Input Power

Input Power
20 40 20 40
20 8 20 8
Input Power Input Power
10 20 10 20
10 4 10 4
0 0 0 0
0 0 0 0
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21
0 500 1000 1500 2000 2500 3050 PSI 0 500 1000 1500 2000 2500 3050 PSI
Pressure Pressure

Input Power
Example: At a pressure of under 16 MPa (2320 PSI), a flow 45 L /min (11.9 U.S.GPM), and rotation 1500 r/min, the
axial input becomes about 12.6 kW (16.9 HP) as shown the dotted line in the graph.
HP P=MPa(PSI) HP P=MPa(PSI)
35 kW N=1500 r/min 35 kW N=1800 r/min
25 P= 20 (2900) 25 P= 20 (2900)
30 P= 18 (2610) 30 P= 18 (2610)
20 P= 16 (2320) 20 P= 16 (2320)
25 P= 14 (2030) 25 P= 14 (2030)
Input Power

Input Power

P= 12 (1740) P= 12 (1740)
20 15 20 15
P= 10 (1450) P= 10 (1450)
15 P= 8 (1160) 15 P= 8 (1160)
10 P= 6 (870) 10
P= 6 (870)
10 P= 4 (580) 10 P= 4 (580)
5 P= 2 (290) 5 P= 2 (290)
5 5
P= 1 (150) P= 1 (150)
0 0
0 0
0 10 20 30 40 50 60 70 L /min 0 10 20 30 40 50 60 70 L /min

0 2 4 6 8 10 12 14 16 18 U.S.GPM 0 2 4 6 8 10 12 14 16 18 U.S.GPM
Output Flow Output Flow

Full Cut-off Power Drain


HP kW in.3/min L /min
4 3 180 3
A37-∗-R-01-H Full Cut-off
150 N=1800 r/min
Full Cut-off Power

A37-∗-R-01-C
3 A37-∗-R-01-H
2 120 2 N=1500 r/min
N=1800 r/min
Drain

2 90
A37-∗-R-01-C
1 60 1
1 A37-∗-R-01-B
N=1500 r/min 30 1500,1800 r/min
0 A37-∗-R-01-B 0 Full Flow
0 0
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21
0 500 1000 1500 2000 2500 3050 PSI 0 500 1000 1500 2000 2500 3050 PSI
Full Cut-off Pressure Pressure

Noise Level [One metre (3.3 ft.) horizontally away from pump head cover]
dB(A) N=1500 r/min dB(A) N=1800 r/min
80 80

70 70
Noise Level

Noise Level

Full Flow
Full Flow
60 60
Full Cut-off Full Cut-off
50 50

40 40
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21
0 500 1000 1500 2000 2500 3050 PSI 0 500 1000 1500 2000 2500 3050 PSI
Pressure Pressure

No.12
"A" Series Piston Pumps
A56-∗-R-01 PISTON
PUMPS
A
Typical Pump Characteristics

Typical Performance Characteristics of Type "A56" at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)]

Performance Characteristic Curve


% N=1500 r/min % N=1800 r/min
100 100
Volumetric Efficiency Volumetric Efficiency

Efficiency
Efficiency

Overall Efficiency 80
80
Overall Efficiency
L /min
U.S.GPM
60 60 120
L /min Output Flow 30
HP U.S.GPM HP
100 100
60 kW Output Flow 25 60 kW 25

Output Flow
40 80 20 40 80 20

Output Flow
Input Power

Input Power
40 60 15 40 60 15
Input Power
20 40 10 20 40 10
20 Input Power 20
20 5 20 5
0 0 0 0
0 0 0 0
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21
0 500 1000 1500 2000 2500 3050 PSI 0 500 1000 1500 2000 2500 3050 PSI
Pressure Pressure

Input Power
Example: At a pressure of under 16 MPa (2320 PSI), a flow 70 L /min (18.5 U.S.GPM), and rotation 1500 r/min, the
axial input becomes about 20.8 kW (27.9 HP) as shown the dotted line in the graph.
kW N=1500 r/min kW N=1800 r/min
HP 40 P= 20 (2900) HP 40 P= 20 (2900)
50 50
P= 18 (2610) P= 18 (2610)
35 35
P= 16 (2320) P= 16 (2320)
40 30 40 30 P= 14 (2030)
P= 14 (2030)
Input Power

P= 12 (1740)
Input Power

25 P= 12 (1740) 25
30 30 P= 10 (1450)
20 P= 10 (1450) 20
P= 8 (1160)
P= 8 (1160)
20 15 20 15 P= 6 (870)
P= 6 (870)
P= 4 (580)
10 P= 4 (580) 10
10 10 P= 2 (290)
5 P= 2 (290) 5 P=MPa(PSI)
0 P=MPa(PSI) 0
0 0
0 20 40 60 80 100 120 L /min 0 20 40 60 80 100 120 L /min

0 5 10 15 20 25 30 U.S.GPM 0 5 10 15 20 25 30 U.S.GPM
Output Flow Output Flow

Full Cut-off Power Drain


HP kW L /min
4 4
5
in.3/min Full Cut-off N=1800 r/min
200
4 3
Full Cut-off Power

N=1800 r/min 150 A56-∗-R-01-H


3
Drain

2 2 A56-∗-R-01-C
2 100
N=1500 r/min
Full Flow
1 1 A56-∗-R-01-B
1 50 1500,1800 r/min
N=1500 r/min
0 0
0 0
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21

0 500 1000 1500 2000 2500 3050 PSI 0 500 1000 1500 2000 2500 3050 PSI
Full Cut-off Pressure Pressure

Noise Level [One metre (3.3 ft.) horizontally away from pump head cover]
dB(A) N=1500 r/min dB(A) N=1800 r/min
80 80
Noise Level

Noise Level

70 70
Full Flow Full Flow

60 60
Full Cut-off Full Cut-off
50 50
0 4 8 12 16 20 MPa 0 4 8 12 16 20 MPa
21 21
0 500 1000 1500 2000 2500 3050 PSI 0 500 1000 1500 2000 2500 3050 PSI
Pressure Pressure

No.13
"A" Series Piston Pumps
A70-∗R01 PISTON
Typical Pump Characteristics
PUMPS

Typical Performance Characteristics of Type "A70" at Viscosity 32 mm2/s (150 SSU) [ISO VG32 Oils, 40°C (104°F)]

Performance Characteristics Curve


% N=1500 r/min % N=1800 r/min
100 100
Efficiency

Efficiency
Overall Efficiency L /min
Overall Efficiency
80 80 140 U.S.GPM
L /min 35

Output Flow
Volumetric Efficiency
60 120 U.S.GPM 60 Output Flow 120
30 30
HP kW HP kW

Output Flow
80 60 Output Flow 100 80 60 100
25 Volumetric Efficiency 25
Input Power

Input Power
60 60
40 80 40
20 Input Power
40 Input Power 40
20 20
20 20
0 0
0 0
0 5 10 15 20 25 MPa 0 5 10 15 20 25 MPa

0 1000 2000 3000 3500 PSI 0 1000 2000 3000 3500 PSI
Pressure 3630 Pressure 3630

Input Power
Example: At a pressure of under 20 MPa (2900 PSI), a flow 70 L /min (18.5 U.S.GPM), and rotation 1500 r/min, the
axial input becomes about 26 kW (35 HP) as shown the dotted line in the graph.
HP kW N=1500 r/min HP kW N=1800 r/min P=MPa(PSI)
80 60 80 60 P= 24 (3480)
P=MPa(PSI) P= 22 (3190)
50 P= 24 (3480) 50 P= 20 (2900)
60 P= 22 (3190) 60 P= 18 (2610)
40 P= 20 (2900) 40 P= 16 (2320)
Input Power

Input Power

P= 18 (2610) P= 14 (2030)
P= 16 (2320) P= 12 (1740)
40 30 P= 14 (2030) 40 30
P= 12 (1740) P= 10 (1450)
P= 10 (1450) P= 8 (1160)
20 P= 8 (1160) 20 P= 6 (870)
20 P= 6 (870) 20 P= 4 (580)
10 P= 4 (580) 10 P= 2 (290)
P= 2 (290)
0 0
0 0
0 20 40 60 80 100 120 140 L /min 0 20 40 60 80 100 120 140 L /min

0 10 20 30 35 U.S.GPM 0 10 20 30 35 U.S.GPM
Output Flow Output Flow

Full Cut-off Power Drain


kW L /min
HP 7 in.3/min 7
10 400
8 6 6

5 300 5
Full Cut-off Power

6 1800 r/min Full Cut-off


4 4
1500,1800 r/min
Drain

200
4 3 3
1500 r/min
2 2
2 100
1 1 Full Flow
1500,1800 r/min
0 0
0 0
0 5 10 15 20 25 MPa 0 5 10 15 20 25 MPa

0 1000 2000 3000 3500 PSI 0 1000 2000 3000 3500 PSI
Full Cut-off Pressure 3630 Pressure 3630

Noise Level [One metre (3.3 ft.) horizontally away from pump head cover]
dB(A) N=1500 r/min dB(A) N=1800 r/min
80 80
Noise Level

Noise Level

70 70 Full Flow
Full Flow
60 60
Full Cut-off Full Cut-off
50 50
0 5 10 15 20 25 MPa 0 5 10 15 20 25 MPa

0 1000 2000 3000 3500 PSI 0 1000 2000 3000 3500 PSI
Pressure 3630 Pressure 3630

No.14
"A" Series Piston Pumps
A90-∗R01 PISTON
PUMPS
A
Typical Pump Characteristics

Typical Performance Characteristics of Type "A90" at Viscosity 32 mm2/s (150 SSU) [ISO VG32 Oils, 40°C (104°F)]

Performance Characteristics Curve


% N=1500 r/min % N=1800 r/min
100 100

Efficiency
Efficiency

Overall Efficiency Overall Efficiency


80 80
Volumetric Efficiency
60 60
Volumetric Efficiency L /min
170 U.S.GPM
L /min U.S.GPM kW Output Flow 44
38 HP
140 160

Output Flow
80

Output Flow
Output Flow 42
36 100
HP kW
80 60 130 80 60 150 40
34

Input Power
Input Power

40 120 40 Input Power 140


Input Power
40 40
20 20
0 0
0 0
0 5 10 15 20 25 MPa 0 5 10 15 20 25 MPa

0 1000 2000 3000 3500 PSI 0 1000 2000 3000 3500 PSI
Pressure 3630 Pressure 3630

Input Power
Example: At a pressure of under 18 MPa (2610 PSI), a flow 110 L/min (29.1 U.S.GPM), and rotation 1500 r/min, the
axial input becomes about 34 kW (46 HP) as shown the dotted line in the graph.
HP P=MPa(PSI)
kW N=1500 r/min 100 kW N=1800 r/min P= 25 (3630)
70 70
P=MPa(PSI) P= 24 (3480)
HP
P= 25 (3630) P= 22 (3190)
80 60 80 60
P= 24 (3480) P= 20 (2900)
P= 22 (3190) P= 18 (2610)
50 P= 20 (2900) 50
60 60 P= 16 (2320)
P= 18 (2610)
P= 14 (2030)
Input Power

Input Power

40 P= 16 (2320) 40
P= 14 (2030) P= 12 (1740)
40 30 P= 12 (1740) 40 30 P= 10 (1450)
P= 10 (1450) P= 8 (1160)
20 P= 8 (1160) 20 P= 6 (870)
P= 6 (870) P= 4 (580)
20 P= 4 (580) 20
10 P= 2 (290) 10 P= 2 (290)

0 0
0 0
0 20 40 60 80 100 120 140 L /min 0 20 40 60 80 100 120 140 160 L /min

0 5 10 15 20 25 30 35 U.S.GPM 0 5 10 15 20 25 30 35 40 45 U.S.GPM
Output Flow Output Flow

Full Cut-off Power Drain


kW
HP 7
9 in.3/min L /min
500 8
8 6

5 400
Full Cut-off Power

6 6
4 300
Drain

1800 r/min Full Cut-off


4 3 4
1800 r/min
1500 r/min 200
2 1500 r/min
2 2 1800 r/min
100
1
Full Flow 1500 r/min
0 0
0 0
0 5 10 15 20 25 MPa 0 5 10 15 20 25 MPa

0 1000 2000 3000 3500 PSI 0 1000 2000 3000 3500 PSI
3630 3630
Full Cut-off Pressure Pressure

Noise Level [One metre (3.3 ft.) horizontally away from pump head cover]
dB(A) dB(A) N=1800 r/min
N=1500 r/min
80 80

70 Full Flow
Noise Level
Noise Level

70
Full Flow

60 60
Full Cut-off Full Cut-off

50 50
0 5 10 15 20 25 MPa 0 5 10 15 20 25 MPa

0 1000 2000 3000 3500 PSI 0 1000 2000 3000 3500 PSI
3630 3630
Pressure Pressure

No.15
"A" Series Piston Pumps
A145-∗R01 PISTON
Typical Pump Characteristics
PUMPS

Typical Performance Characteristics of Type "A145" at Viscosity 32 mm2/s (150 SSU) [ISO VG32 Oils, 40°C (104°F)]

Performance Characteristics Curve


% N=1500 r/min % N=1800 r/min
100 100
Efficiency

Efficiency
Overall Efficiency Overall Efficiency
80 80
Volumetric Efficiency
60 60
L /min U.S.GPM Volumetric Efficiency L /min
Output Flow 220 58 270 U.S.GPM

Output Flow
70
56

Output Flow
210 Output Flow 260
HP kW HP kW 68
54
160 120 200 160 120 250 66
Input Power

Input Power
120 120
80 80 240
80 Input Power 80 Input Power
40 40
40 40
0 0
0 0
0 5 10 15 20 25 MPa 0 5 10 15 20 25 MPa

0 1000 2000 3000 3500 PSI 0 1000 2000 3000 3500 PSI
Pressure 3630 Pressure 3630

Input Power
Example: At a pressure of under 20 MPa (2900 PSI), a flow 180 L/min (47.6 U.S.GPM), and rotation 1500 r/min, the
axial input becomes about 64 kW (86 HP) as shown the dotted line in the graph.
kW N=1500 r/min P=MPa(PSI) HP kW N=1800 r/min P=MPa(PSI)
140 140 P= 28 (4060)
HP P= 28 (4060) 180
P= 26 (3770) P= 26 (3770)
160 120 160 120 P= 24 (3480)
P= 24 (3480) P= 22 (3190)
140 P= 22 (3190) 140
100 P= 20 (2900) 100 P= 20 (2900)
120 P= 18 (2610) 120 P= 18 (2610)
Input Power
Input Power

80 P= 16 (2320) 80 P= 16 (2320)
100 100 P= 14 (2030)
P= 14 (2030)
80 60 P= 12 (1740) 80 60 P= 12 (1740)
P= 10 (1450) P= 10 (1450)
60 P= 8 (1160) 60 P= 8 (1160)
40 40 P= 6 (870)
40 P= 6 (870) 40
P= 4 (580) P= 4 (580)
20 20 P= 2 (290) 20 P= 2 (290)
20
0 P= 1 (145) 0 P= 1 (145)
0 0
0 40 80 120 160 200 240 L /min 0 40 80 120 160 200 240 280 L /min

0 10 20 30 40 50 60 U.S.GPM 0 10 20 30 40 50 60 70 U.S.GPM
Output Flow Output Flow

Full Cut-off Power Drain


kW
12.5
HP
15
in.3/min L /min
10.0 600 10.0
Full Cut-off Power

10 7.5 7.5
1800 r/min Full Cut-off
400
1800 r/min
1500 r/min
Drain

5.0 5
1500 r/min
5
200
2.5 2.5
Full Flow
0 0
0 0
0 5 10 15 20 25 MPa 0 5 10 15 20 25 MPa

0 1000 2000 3000 3500 PSI 0 1000 2000 3000 3500 PSI
Full Cut-off Pressure 3630 Pressure 3630

Noise Level [One metre (3.3 ft.) horizontally away from pump head cover]
dB(A) N=1500 r/min dB(A) N=1800 r/min
90 90
Noise Level

Noise Level

80 80
Full Flow
Full Flow
70 70
Full Cut-off
Full Cut-off
60 60
0 5 10 15 20 25 MPa 0 5 10 15 20 25 MPa

0 1000 2000 3000 3500 PSI 0 1000 2000 3000 3500 PSI
Pressure 3630 Pressure 3630

No.16
"A" Series Piston Pumps
A10-FR01 PISTON
PUMPS
A
Installation Drawing

Flange Mtg.: A10-FR01C-12/1280/1290


A10-FR01H-12/1280/1290
1
Filling Port
Pressure Adj. Screw Flow Adj. Screw [8(.31) Hex. Soc. Plug Furnished]
3
13(.51) Hex. 13(.51) Hex. 44.5(1.75) Drain Port
Fully Extended
INC. "D" Thd.
Fully Extended 186(7.32) 4.79(.1886)
DEC. 90.5 6.5(.26)
103(4.06) 4.76(.1874)
(3.56)
52.5 25(.98) Key Width
34(1.34) Dia.
Spotface (2.07)

(4.06)

65(2.56)
41(1.61)
2 Places
(3.35)

103
85

(6.57)
167

31(1.22)

(.47)
12
19.02(.7488) Dia.

82.50(3.248) Dia.
21.24(.836)
21.08(.830)
10.5(.41)

19.05(.7500)

82.55(3.250)
2 3 2 3
Suction Port 25 25 Discharge Port 106
"C" Thd. (.98) (.98) "C" Thd. 131 (4.17)
64.5 64.5 130
(5.16) (5.12)
(2.54) (2.54) 156
93(3.66) Dia.
(6.14)
159.5
(6.28)

Thread Size
Model Numbers
"C" Thd. "D" Thd.
Flange Mtg.: A10-FR01B-12/1280/1290
A10-FR01∗-12 Rc 1/2 Rc 3/8
A10-FR01∗-1280 1/2 BSP.F 3/8 BSP.F
A10-FR01∗-1290 1/2 NPT 3/8 NPT

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two suction and discharge ports at your option.
Keep the remaining ports plugged.
3. As the tightening torques of suction, discharge and drain port
fittings, conform to the below.
25 25
Tughtening Torque Nm(IN. lbs.)
(.98) (.98) 131
Model Numbers Suction Port & 64.5 64.5 (5.16)
Drain Port (2.54) (2.54)
Discharge Port 156
(6.14)
A10-FR01B-12/1290 65-75 (575-664) 40-50 (354-443)
A10-FR01C/H-12/1290 65-75 (575-664) 40-50 (354-443) For other dimensions, refer to above drawing.

A10-FR01B-1280 98-108 (867-956) 39-43 (345-381)


A10-FR01C/H-1280 98-108 (867-956) 39-43 (345-381)

DIMENSIONS IN
MILLIMETRES (INCHES)
Mounting Bracket Kit: LP-1A-10

17
(.67) 12(.47) Dia. Through
Mtg. Bracket 24(.94) Dia. Spotface
4 Places
(5.73)
145.5
(3.15)
80
(.12)
3

(.59)
(.55)

Hex. Bolt
15
14

(2 Pcs.) 50 56.5 95
M10×25 Lg. (1.97) (2.22) (3.74)
95 27.5 72.5 72.5
Plain Washer
(2 Pcs.) (3.74) (1.08) (2.854) (2.854)
180
(7.09)

No.17
"A" Series Piston Pumps
A16 / A22-F-R-01 PISTON
Installation Drawing
PUMPS

Axial Port Type

Flange Mtg.: A16-F-R-01-∗-K-32/3280/3290 Model Numbers "C" Thd. "D" Thd.


A22-F-R-01-∗-K-32/3280/3290 A16/A22-F-R-01-∗-K-32 Rc 3/8
M 10
A16/A22-F-R-01-∗-K- 3/8 BSP.F
3280 3/8 NPT 3/8-16 UNC

Lock Nut 17(.67) Hex. Fully Extended 44.5(1.75)


219(8.62)
59 6.5
Filling Port
16 16 (2.32) (.26)
[22(.87) Hex. Head Plug Furnished]
Flow Adj. Screw (.63) (.63) Pressure Adj. Screw 26.5
17(.67) Hex. 17(.67) Hex. (1.04) Drain Port "C" Thd.
4.79(.1886)

82.55(3.250) Dia.
DEC. INC. 25(.98)

96(3.78)
4.76(.1874)
(4.29)
109

(2.44)

82.50(3.248)
(7.36)

62
187
(1.874)
47.6

(.47)

(.71)
12

18
19.02(.7488) Dia.
21.24(.836)
21.08(.830)
19.05(.7500)
R12
"D" Thd. 95(3.74) Dia.
22.2 17(.67) Deep (R .47)
Suction Port 12 106
(.874) 8 Places
19(.75) Dia. 65 (.47) (4.17)
Discharge Port 172 130
(2.56)
19 (.75) Dia. (6.77) (5.12)
188
(7.40)
Install the pump so that the "Filling Port" is at the top.

Foot Mtg.: A16-L-R-01-∗-K-32/3280/3290


A22-L-R-01-∗-K-32/3280/3290
12(.47) Dia. Through
24(.94) Dia. Spotface
4 Places

(3.15)
(.59)
(.55)
15
14

80
3(.12)

50 56.5 95
(1.969) (2.22) (3.74)
95 27.5 72.5 72.5
(3.74) (1.08) (2.854) (2.854)
180
(7.09)
For other dimensions, refer to "Flange Mtg.".

DIMENSIONS IN
Side Port Type MILLIMETRES (INCHES)
Flange Mtg.: A16-F-R-01-∗-S-K-32/3280/3290
A22-F-R-01-∗-S-K-32/3280/3290 Discharge Port 19 (.75) Dia.
Rear Side
"D" Thd. 17 (.67) Deep Suction Port 19 (.75) Dia.
4 Places (Both Sides) 44.5
188 Fully Extended (1.75)
(7.40) 219(8.62)
78(3.07) 109(4.29)

47.6(1.874)

74 74 22.2
(2.91) (2.91) (.874)
Surface of Suction Port Surface of Discharge Port 150.5
(5.93)
For other dimensions, refer to "Axial Port Type".

No.18
"A" Series Piston Pumps
A37-F-R-01 PISTON
PUMPS
A
Installation Drawing

Axial Port Type


Flange Mtg.: A37-F-R-01-∗-K-32/3280
Model Numbers "C" Thd.
A37-F-R-01-∗-K-32 Rc 1/2
A37-F-R-01-∗-K-3280 1/2 BSP.F
Lock Nut 17(.67) Hex. Fully Extended 59(2.32)
247(9.72)
77 9.5
(3.03) (.37) Filling Port
Flow Adj. Pressure Adj. Screw 30 [22(.87) Hex. Head Plug Furnished]
13 19
Screw (.51) (.75) 17(.67) Hex. (1.18) Drain Port "C" Thd.
17(.67) Hex.
INC. 6.38(.2512)
DEC. 32(1.26) 6.35(.2500)
(4.41)

(4.13)
112

105

(.98)
(2.68)

25
(.55)
68
(7.95)

14
(2.311)

202
58.7

22.20(.8740) Dia.
25.01(.985)
24.85(.978)

101.55(3.998) Dia.
R14

22.23(.8752)
(R .55)

101.60(4.000)
120(4.72) Dia.
Suction Port 30.2 12
M10 Thd. 19(.75) Deep 146
32(1.26) Dia. (1.189) (.47)
8 Places (5.75)
72 195
Discharge Port 32 (1.26) Dia. 174
(2.83) (7.68) (6.85)
202
(7.95)
Install the pump so that the "Filling Port" is at the top.
Note: "Axial Port Type" is not available for N.American design Standard.

Foot Mtg.: A37-L-R-01-∗-K-32/3280 14(.55) Dia. Through


28(1.10) Dia. Spotface
4 Places
(4.02)
(.59)
(.55)

102
3(.12)

15
14

60 74 120
(2.362)(2.91) (4.72)
115 39 95 95
(4.53) (1.54) (3.740) (3.740)
230
(9.06)

For other dimensions, refer to "Flange Mtg.".


DIMENSIONS IN
Side Port Type MILLIMETRES (INCHES)
Flange Mtg.: A37-F-R-01-∗-S-K-32/3280/3290
Discharge Port 32 (1.26) Dia.
"D" Thd. "E" Deep Rear Side E
4 Places (Both Sides) Suction Port 32 (1.26) Dia. Model Numbers "C" Thd. "D" Thd.
mm (IN.)
202
A37-F-R-01-S-∗-K-32
Fully Extended 59
(7.95) Rc 1/2
247(9.72) (2.32) M 10 19 (.75)
A37-F-R-01-S-∗-K-3280 1/2 BSP.F
A37-F-R-01-S-∗-K-3290 1/2 NPT 7/16-14 UNC 20 (.79)
112(4.41)

58.7(2.311)
202(7.95)

86 86 30.2
(3.39) (3.39) (1.189)
Surface of Surface of 178.5
Suction Port Discharge Port (7.03)
For other dimensions, refer to "Axial Port Type".
Foot Mtg. Type; Mounting bracket is common to that of "Axial Port Type".

No.19
"A" Series Piston Pumps
A56-F-R-01 PISTON
Installation Drawing
PUMPS

Axial Port Type


Flange Mtg.: A56-F-R-01-∗-K-32/3280 Model Numbers "C" Thd.
A56-F-R-01-∗-K-32 Rc 3/4
62
(2.44)
A56-F-R-01-∗-K-3280 3/4 BSP.F
Lock Nut 17(.67) Hex. Fully Extended
259.5(10.22) Filling Port 1
50.5(1.99) 9.5 [22(.87) Hex. Head Plug Furnished]
Surface of
(.37) 2
13 19 Pressure Adj. Screw Drain Port "C" Thd. Drain Port
Flow Adj. (.51) (.75) 17(.67) Hex. 43.5(1.71) (Both Sides) 41 49
Screw (1.61) (1.93)

35.32(1.391)
35.14(1.383)
17(.67) Hex. INC. 40 7.97(.3138)

Dia.
(1.57) 7.94(.3126)
(5.43)
138

DEC.

101.60(4.000)
101.55(3.998)
(3.54)

(3.03)

(.55)
90

14
77
(9.29)
(2.311)
236

(.98)
58.7

25
31.70(1.248) Dia.
R14

31.75(1.250)
120(4.72) Dia. (R.55)
Suction Port 30.2 "MIO" Thd. 19(.75) Deep 12 146
35(1.38) Dia. (.189) 8 Places (.47) (5.75)
26 207 174
Discharge Port 32 (1.26) Dia. (8.15) (6.85)
(2.99)
232
(9.13)
1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of the two drain ports at your option. Keep the remaining port plugged. Note that on the European design standard (3280 Design),
only the left side, as viewed from the shaft end, of the drain port is machined.
Note: "Axial Port Type" is not available for N.American design Standard.

Foot Mtg.: A56-L-R-01-∗-K-32/3280


14(.55) Dia. Through
28(1.10) Dia. Spotface
4 Places
(4.02)
(.55)

(.59)
102
3(.12)

14

15

60 77 120
(2.362) (3.03) (4.72)
115 42 95 95
(4.53) (1.65) (3.740) (3.740)
230
(9.06)
For other dimensions, refer to "Flange Mtg.".

DIMENSIONS IN
Side Port Type MILLIMETRES (INCHES)
Flange Mtg.: A56-F-R-01-∗-S-K-32/3280/3290
Discharge Port 30 (1.18) Dia.
Rear Side
"D" Thd. "E" Deep Suction Port 35 (1.38) Dia. E
4 Places (Both Sides) Model Numbers "C" Thd. "D" Thd.
232 Fully Extended 62(2.44) mm (IN.)
A56-F-R-01-S-∗-K-32
(9.13) 259.5(10.22)
Rc 3/4
M 10 19 (.75)
A56-F-R-01-S-∗-K-3280 3/4 BSP.F
(5.43)

A56-F-R-01-S-∗-K-3290 3/4 NPT 7/16-14 UNC 20 (.79)


138

58.7(2.311)
(9.29)
236

100 100 30.2


(3.94) (3.94) (1.189)
Surface of Surface of 191
Suction Port Discharge Port (7.52)
For other dimensions, refer to "Axial Port Type".
Foot Mtg. Type; Mounting bracket is common to that of "Axial Port Type".

No.20
"A" Series Piston Pumps
A70-FR01 PISTON
PUMPS
A
Installation Drawing

Flange Mtg.: A70-FR01∗S-60/6080/6090


Surface of Surface of
62 Discharge Port Suction Port
Fully Extended (2.44) 95 95
310.5(12.22) (3.74) (3.74)
19.5(.77) Surface of Surface of
2
65 Drain Port Drain Port
Drain Port (2.56) 73 73 7.97(.3138)
"C" Thd. (Both Sides) 9.5(.37) (2.87) (2.87) 7.94(.3126)
40(1.57)
27(1.06) Dia. Spotface
(From Rear)

(7.17)
Y X

182
4 Places

14(.55)
(3.54)
90
(2.063)

(7.09)
(4.50)
52.4

114.4

180
18(.71)

14(.55)
31.70(1.248) Dia.

(4.65)
118
126.95(4.998) Dia.
31.75(1.250)

35.32(1.391)
35.14(1.383)
Discharge Port
26(1.02) Dia.
127.00(5.000)

16
26.2 (.63) 114.4 35(1.38) Dia.
(1.301) 18 (4.50) Spotface
"E" Thd. (.71) 134 (From Rear)
17(.67) Deep 246.5 (5.28) 2 Places
4 Places (9.70) 181
(7.13)
211
(8.31)

Eye Bolt
1 M10
Filling Port
[22(.87) Hex. Head Plug Furnished]

Suction Port
38(1.50) Dia.

(2.752)
Flow Adj. Screw 69.9
17(.67) Hex. Pressure Adj. Screw
17(.67) Hex.
DEC.
INC. "D" Thd. "F" Deep
4 Places
3
Case Drain Port 35.7
View Arrow Y 5(.20) Hex. Soc. (1.406)
246.5
(9.70)
View Arrow X
1. Install the pump so that the "Filling Port" is at the top. F
2. Use either port of the two drain ports at your option. Keep the Model Numbers "C" Thd. "D" Thd. "E" Thd.
mm (IN.)
remaining port plugged. Note that on the European design standard
(6080 design), only the left side, as viewed from the shaft end, of the A70-FR01∗S-60 Rc 3/4
M 12 M 10 19 (.75)
drain port is machined. A70-FR01∗S-6080 3/4 BSP.F
3. Case drain port is available for use when draining hydraulic fluid A70-FR01∗S-6090 3/4 NPT 1/2-13 UNC 3/8-16 UNC 21 (.83)
from pump casing.

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: A70-LR01∗S-60/6080/6090
42.5
(1.67)
(5.00) Dia.

22(.87) Dia. Through


43(1.69) Dia. Spotface
127

4 Places
(5.12)
130

(.12)
3

24(.94)

25(.98)

125 77 171
(4.921) (3.03) (6.73)
195 37 130 130
(7.68) (1.46) (5.118) (5.118)
320
(12.60)
For other dimensions, refer to "Flange Mtg.".

No.21
"A" Series Piston Pumps
A90-FR01 PISTON
Installation Drawing
PUMPS

Flange Mtg.: A90-FR01∗S-60/6080/6090


2
Drain Port
"C" Thd. (Both Sides)
Surface of Surface of
Fully Extended 95(3.74) Discharge Port 105 105 Suction Port
329(12.95)
(4.13) (4.13)
119.5 23(.91)
68 68
(4.70) Surface of Surface of
13(.51) Drain Port (2.68) (2.68) Drain Port

63(2.48)

(7.50)
190.5
(4.45)
58.7(2.311)

113
Y 9.56(.3764)

(6.362)
161.6
9.53(.3752) X

(5.00)
127
38.05(1.498) Dia.

152.35(5.998) Dia.
Discharge Port
42.36(1.668)
42.18(1.661)
32(1.26) Dia. 21.5(.85) Dia. Through R22
38.10(1.500)

22
152.40(6.000)
30.2 (.87) 39(1.54) Dia. Spotface 161.6 (R.87)
"E" Thd. (1.189) (From Rear) (6.362)
"F" Deep 23
4 Places
4 Places (.91)
270
(10.63) 3
Case Drain Port
5(.2) Hex. Soc.

Eye Bolt
Pressure Adj. Screw M10
Flow Adj. Screw 17(.67) Hex. 1
17(.67) Hex. Filling Port
[27(1.06) Hex. Head Plug Furnished]
INC. Suction Port
DEC. 48(1.89) Dia.

(3.063)
77.8
View Arrow Y
"D" Thd. "F" Deep
4 Places
42.9
(1.689)
270
(10.63)

View Arrow X

1. Install the pump so that the "Filling Port" is at the top.


F
Model Numbers "C" Thd. "D" Thd. "E" Thd.
2. Use either port of the two drain ports at your option. Keep the remain- mm (IN.)
ing port plugged. Note that on the European design standard
(6080 design), only the left side, as viewed from the shaft end, of A90-FR01∗S-60 Rc 3/4
M 12 M 10 19 (.75)
the drain port is machined. A90-FR01∗S-6080 3/4 BSP.F
3. Case drain port is available for use when draining hydraulic fluid A90-FR01∗S-6090 3/4 NPT 1/2-13 UNC 7/16-14 UNC 21 (.83)
from pump casing.

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: A90-LR01∗S-60/6080/6090

22(.87) Dia. Through


43(1.69) Dia. Spotface
4 Places
24(.94)

25(.98)
(5.51)
140

(.12)
3

125 110 215


(4.921) (4.33) (8.46)
200 70 157.5 157.5
(7.87) (2.76) (6.201) (6.201)
375
For other dimensions, refer to "Flange Mtg.". (14.76)

No.22
"A" Series Piston Pumps
A145-FR01 PISTON
PUMPS
A
Installation Drawing

Flange Mtg.: A145-FR01∗S-60/6080/6090


Drain Port 2 143
"C" Thd. (Both Sides) (5.63)
357.5 112 Surface of Surface of
(14.07) (4.41) Discharge Port 112 112 Suction Port
89 23 (4.41) (4.41)
(3.50) (.91) 72 72
Flow Adj. Screw 13 Surface of Surface of
Drain Port (2.83) (2.83) Drain Port
17(.67) Hex. (.51)
70
INC. (2.76)

(7.81)
198.5
11.14
11.11

(4.33)
110
.4386
(2.311)

(9.00)
228.6
.4374
58.7

(5.55)
141
Discharge Port
44.40(1.748) Dia.

152.35(5.998) Dia.
49.39(1.944)
49.21(1.937)
32(1.26) Dia.
44.45(1.750)

152.40(6.000)
30.2 24 R22 228.6 21.5(.85) Dia. Through
"E" Thd. "H" Deep (1.189) (.94) (R .87) (9.00) 39(1.54) Dia. Spotface
4 Places 273 (From Rear)
26
(10.75) 4 Places
3 (1.02)
Case Drain Port 299.5
5(.2) Hex. Soc. (11.79)

1
Filling Port
[27(1.06) Hex. Head Plug Furnished]
Eye Bolt
M10
Pressure Adj. Screw
17(.67) Hex.
1. Install the pump so that the "Filling Port" is at the top.
INC. 2. Use either port of the two drain ports at your option. Keep the
Suction Port remaining port plugged. Note that on the European design standard
48(1.89) Dia. (6080 design), only the left side, as viewed from the shaft end, of the
drain port is machined.
(3.063)
77.8

3. Case drain port is available for use when draining hydraulic fluid
from pump casing.

"D" Thd. "F" Deep


4 Places
42.9
(1.689) Dimensions mm (IN.)
299.5 Model Numbers "C" Thd. "D" Thd. "E" Thd.
(11.79)
F H
A145-FR01∗S-60 Rc 3/4
M 12 M 10 19 (.75) 19 (.75)
A145-FR01∗S-6080 3/4 BSP.F
View Arrow X
A145-FR01∗S-6090 3/4 NPT 1/2-13 UNC 7/16-14 UNC 21 (.83) 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: A145-LR01∗S-60/6080/6090

22(.87) Dia. Through


43(1.69) Dia. Spotface
4 Places
(7.37)
187.3

(.12)
3

29(1.14)

30(1.18)

114.3 119 280


(4.500) (4.69) (11.02)
185 80 187.3 187.3
(7.28) (3.15) (7.374) (7.374)
438
(17.24)

For other dimensions, refer to "Flange Mtg".

No.23
"A" Series Piston Pumps
A10-FR01 PISTON
Spare Parts List
PUMPS
CAUTION
A10-FR01∗-12/1280/1290 When making replacement of seals or bearings,
please do it carefully after reading through the
relevant instructions in the Operator's Manual.

X
37 41 64 39 23 37 36 35 38 25 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
24 X
6
5

34 33 32 31 30 29 28 27 26 1 2 3 4

51 52 53 54 55 56 57 58 59 60 61

63 62

Section X-X

List of Seals & Bearings


Qty.
Item Name of Parts Part Numbers Pres. Adj. Range
B C&H
2 Oil Seal TCN24408Y 1 1
6 O-Ring SO-NA-G50 1 1
7 Bearing 6204 1 1
16 O-Ring SO-NB-P14 1 1
20 O-Ring SO-NB-G120 1 1
23 O-Ring SO-NB-P6 2 2
33 Bearing HMK1215 1 1
37 O-Ring SO-NB-P12 6 5
54 O-Ring SO-NA-A018 1 1
62 O-Ring SO-NB-P10 1 1
64 O-Ring SO-NB-P9 1
When ordering seals, please specify the seal kit number from the table below.

List of Seals Kits


Pump Model Numbers Seal Kit Numbers
A10-FR01B-12/1280/1290 KS-A10-01B-12
A10-FR01C-12/1280/1290
KS-A10-01H-12
A10-FR01H-12/1280/1290

No.24
"A" Series Piston Pumps
A16 / A22 / A37 / A56-∗-R-01 PISTON
PUMPS
A
Spare Parts List
A16/A22/A37/A56-∗-R-01-∗-∗-K-32/3280/3290
56
25 40 35 9 43 2 44 3 25 11 52 60 31 4 22 1 32
27

61
X 58
X

29
57
51

5
55
54

49

53
28 50 7 30 19 33 20 17 8 10 21

38 43 37 15 18 24 12 34 39 16 41 36 6 42

47

46

23
CAUTION
When making replacement of seals or bearings,
45 please do it carefully after reading through the
relevant instructions in the Operator's Manual.
14
13

Section X-X

List of Seal and Bearings


Part Numbers
Item Name of Parts Qty.
A16-∗-R-01 A22-∗-R-01 A37-∗-R-01 A56-∗-R-01
27 Bearing 6305 6307 NUP 207E 1
28 Bearing HMK 1715 Z30-1303-PK410300-8 HMK 2025V2 HMK 2530V2 1
29 Oil Seal TCN 254511 TCN 355511 TCN 355511 1
30 Gasket 1303-PK211969-1 1316-PK211970-9 1307-PK211971-7 1
35 O-Ring SO-NA-G25 SO-NB-G30 SO-NA-P36 2
36 O-Ring SO-NB-P12 SO-NB-P10A 1
37 O-Ring SO-NB-P9 1
38 O-Ring SO-NA-A017 1
39 Seal Washer W8 1
60 O-Ring SO-NB-P14 1
61 O-Ring SO-NA-G55 SO-NA-G75 1
When ordering seals, please specify the seal kit number from the table below.

List of Seal Kits


Pump Model Numbers Seal Kit Numbers
A16-∗-R-01-∗-K-∗-32∗
KS-A16-01-32
A22-∗-R-01-∗-K-∗-32∗
A37-∗-R-01-∗-K-∗-32∗ KS-A37-01-32
A56-∗-R-01-∗-K-∗-32∗ KS-A56-01-32

No.25
"A" Series Piston Pumps
A70 / A90-∗R01 PISTON
Spare Parts List
PUMPS
CAUTION
A70/A90-∗R01∗S-60/6080/6090 When making replacement of seals or bearings,
please do it carefully after reading through the
relevant instructions in the Operator's Manual.

25 26 27 28 29 30 31 32 33
63
55 27 26 55 37 12 32 56 36 67 3 1 4
53
A 51
46
9
35 42
P
45 X X
Q 60
Z
64 62

34 6

54 40

Z 47 38

48

52

66

39 25 2 61 5 33 31 13 28 16 15 14 17 29 65 30

23 58 44 11 7 8 59 22 44 70

24 19 43 21 20 18 10 54 50 44 68 69 Detail "A" Section Z-Z


Section X-X
Section X-X
(Only for "A70")
List of Seals and Bearings
Part Numbers
Item Name of Parts Qty.
A70-∗R01∗S A90-∗R01∗S
5 Gasket 1314E-PK211972-5 1310E-PK211973-3 1
22 Back Up Ring 1310E-PK412440-0 1310E-PK412440-0 1
38 Bearing NUP 208EX50 NUP 210E 1
39 Needle Bearing HMK 3030V2 HMK 3530BV2 1
40 Oil Seal TCN 355511 TCN 456812 1
42 O-Ring SO-FA-G85 SO-FA-G95 1
43 O-Ring SO-NA-P18 SO-NA-P18 1
44 O-Ring SO-NB-P9 SO-NB-P9 3
67 O-Ring SO-NB-P14 SO-NB-P18 1
68 Seal Washer W10 1
70 O-Ring SO-NB-P5 1
List of Seal Kits
Pump Model Numbers Seal Kit Numbers When ordering the seals, please specify the seal kit number
from the table left.
A70-∗R01∗S-60∗ KS-A70-01-60
A90-∗R01∗S-60∗ KS-A90-01-60

No.26
"A" Series Piston Pumps
A145-∗R01 PISTON
PUMPS
A
Spare Parts List
CAUTION
A145-∗R01∗S-60/6080/6090 When making replacement of seals or bearings,
please do it carefully after reading through the
relevant instructions in the Operator's Manual.

58 69 51 52 36 65 62 46 65 14 8 7 33 16 3 60 37 73 59 5 61
25 9
A
59 44
X X
67 54
70 41
35 68
27 4
29 64
74 39
30 57
40 28
53 2 34 26 11 6 1 32 38 10 13 12 16 71 31 72
26 27 28 29 30 31 32 33 34
24 62 56 19 17 50 48 66 23

57 63 15 46

20

21 45 43 18 22 59 47 49
Section X-X Detail "A"

List of Seals and Bearings


Item Name of Parts Part Numbers Qty.
6 Gasket 1312-PK211974-1 1
15 Back Up Ring 1310E-PK412440-0 1
39 Bearing NUP 2211ET2 1
40 Needle Bearing 8Q-NK38×55×30 1
41 Oil Seal TCN 507212 1
43 O-Ring S-31.5 (NBR, Hs70) 1
44 O-Ring SO-FA-G105 1
45 O-Ring SO-NA-P18 1
46 O-Ring SO-NB-P9 2
47 O-Ring SO-NB-A017 1
48 O-Ring SO-NB-A016 1
49 Back Up Ring For SO-NB-A017 1
50 Back Up Ring For SO-NB-A016 1
73 O-Ring SO-NB-P18 1
When ordering seals, please specify the kit number "KS-A145-01-60".

No.27
"A" Series Piston Pumps
Variable Displacement-Single Pumps
Solenoid Two Pressure Control Type PISTON
A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Specifications

Graphic Symbol Performance Characteristics

PL PH

Output Flow
SOL SOL
"OFF" "ON"

M
O
PL PH
Pressure

Specifications
Geometric Minimum Operating Pres. Shaft Speed Range Approx. Mass
MPa (PSI) Minimum r/min kg (lbs.)
Displacement Adj. Flow
Model Numbers Adj. Pres.
cm3/rev cm3/rev 2 1 Flange Foot
(cu. in. /rev) (cu. in. /rev) Rated Intermittent MPa (PSI) Max. Min.
Mtg. Mtg.
A16-∗-R-02-∗-K-32∗ 15.8 (.964) 4 (.244) 16 (2320) 21 (3050) 1.2 (170) 1800 600 24.5 (54.0) 26.7 (58.9)
A22-∗-R-02-∗-K-32∗ 22.2 (1.355) 6 (.366) 16 (2320) 16 (2320) 1.2 (170) 1800 600 24.5 (54.0) 26.7 (58.9)
A37-∗-R-02-∗-K-32∗ 36.9 (2.25) 10 (.61) 16 (2320) 21 (3050) 1.2 (170) 1800 600 36 (79.4) 40.3 (88.9)
A56-∗-R-02-∗-K-32∗ 56.2 (3.43) 12 (.73) 16 (2320) 21 (3050) 1.2 (170) 1800 600 43 (94.8) 47.3 (104)
A70-∗R02S∗-60∗ 70.0 (4.27) 30 (1.83) 25 (3630) 25 (3630) 2 (290) 1800 600 63.5 (140) 75.5 (166)
A90-∗R02S∗-60∗ 91.0 (5.55) 56 (3.42) 25 (3630) 25 (3630) 2 (290) 1800 600 80.5 (178) 101 (223)
A145-∗R02S∗-60∗ 145 (8.85) 83 (5.06) 25 (3630) 25 (3630) 2 (290) 1800 600 97.5 (215) 122.5 (270)
1. Whenever setting pressure, make sure the full cut-off pressure never 2. When operating the pump exceeding the rated pressure, operating
exceeds the maximum intermittent pressure. conditions are restricted. Refer to page 6 for the details.

Solenoid Ratings
Voltage (V) Current & Power at Rated Voltage
Electric Coil Frequency
Source Serviceable Inrush Holding Power
Source Type (Hz)
Rating Range (A) (A) (W)
50 100 80 -110 2.42 0.51
A100 100 2.14 0.37
60 90 -120
110 2.35 0.44
50 96 -132 2.02 0.42
A120 120
60 108 -144 1.78 0.31
AC
50 200 160 -220 1.21 0.25
A200 200 1.07 0.19
60 180 - 240
220 1.18 0.22
50 192 - 264 1.01 0.21
A240 240
60 216 - 288 0.89 0.15
D12 12 10.8 - 13.2 2.45
DC
D24 24 21.6 - 26.4 1.23 29
(K Series)
D48 48 43.2 - 52.8 0.61
AC→DC R100 100 90 - 110 0.33
50 /60 29
Rectified R200 200 180 - 220 0.16
Inrush current in the above table shows rms values at maximum stroke.

No.28
"A" Series Piston Pumps
Solenoid Two Pressure Control Type PISTON A
A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Model Number Designation

Model Number Designation


A16 -F -R -02 -S -K -A100 -32 ∗
Series Direction of Control Port Shaft Coil Type of Design Design
Mounting
Number Rotation Type Position Extension Solenoid Valve Number Std.

A16 Viewed from 32


(15.8 cm3/rev) Shaft End
F: None: AC
2
Flange Axial Port A100,A120
A22 02: A200,A240
Mtg. 32
(22.2 cm3/rev) R: Solenoid Two
Clockwise
1
Prsuure Control K: DC Refer to
3

A37 Keyed Shaft D12,D24


L: (Normal) Type S:
D48 32
(36.9 cm3/rev) Foot Side Port
Mtg. (AC→DC Rectified)
A56 R100,R200
32
(56.2 cm3/rev)

A70 -F R 02 S A100 -60 ∗


Series Direction of Control Port Coil Type of Design Design
Mounting
Number Rotation Type Position Solenoid Valve Number Std.

A70 AC
A100,A120 60
(70 cm3/rev) Viewed from
F: A200,A240
Shaft End 02:
Flange Mtg.
A90 Solenoid Two S: DC 3
60 Refer to
(91.0 cm3/rev) R: Prsuure Control Side Port D12,D24
L: 1
Type D48
Foot Mtg. Clockwise
A145 (Normal) (AC→DC Rectified)
60
(145 cm3/rev) R100,R200

1. Available to supply pump with anti-clockwise rotation. Consult 3. Design Standards: None ........... Japanese Standard "JIS"
Yuken for details. 80 ............... European Design Standard
90 ............... N. American Design Standard
2. The axial port is not available to the N. American Design Standard of
A37 and A56 series.

Performance Characteristics
For performance characteristics, refer to models of pressure compensator type on page 10 to 16.

Pipe Flange Kit


For pipe flange, refer to form of pressure compensator type on page 7.

No.29
"A" Series Piston Pumps
A16 / A22-∗-R-02 PISTON
Installation Drawing
PUMPS
Axial Port Type
Flange Mtg.: A16-F-R-02-K-∗-32/3290
A22-F-R-02-K-∗-32/3290

Fully Extended
256.5(10.10) 2
Pilot Port "PP2"
141.5 "E" Thd.
(5.37)
90 138.5
77
(3.54) (5.45)
44.5(1.75) (3.03)
Lock Nut 112 Electrical Conduit
3 53 Connection
14(.55) Hex. (4.41)
(.12) (2.09) "D" Thd. (Both Ends)
59 6.5
(2.32) (.26) 1
26.5 Filling Port
"PP1"
[22(.87) Hex. Head Plug Furnished]
(1.04)
"PP2" Drain Port

(7.70)
195.5
"C" Thd.

(6.97)
4.79(.1886)

177
(5.71)
145
(10.77)

(4.61)

25
273.5

4.76(.1874)
117

(3.78)
(.98)

96
(2.44)

X
62

18(.71)
(.47)
12
19.02(.7488) Dia.

82.50(3.248) Dia.
21.24(.836)
21.08(.830)

R14(R.55)
82.55(3.250)
19.05(.7500)

95(3.74) Dia.
12 106
Lock Nut (.47) (4.17)
17(.67) Hex. 172 130
(6.77) (5.12)
188
2
Pilot Port "PP1" (7.40)
"E" Thd.

16 23 A16-F-R-02-K-∗-3280
(.63) (.91)
Pressure Adj. Screw (PL) A22-F-R-02-K-∗-3280
Pressure Adj. 14(.55) Hex. Cable Departure
Screw (PH) INC. 3(.12)
Works at Solenoid Cable Applicable:
INC.
14(.55) Hex. Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 in.)
De-energised Conductor Area ⋅⋅⋅⋅⋅⋅ Not Exceeding 1.5mm2(.002 Sq. IN.)
Works at Solenoid
Energised 135 80.1
(5.31) (3.15)
Flow Adj. Screw d 53
5(.20) Hex. Soc. (2.09)
(6.34)
161

DEC.
(1.874)
47.6

a
b

Suction Port 22.2(.874) "F" Thd. 17(.67) Deep mm (IN.)


19(.75) Dia. 8 Places Model Numbers
65 a b d
(2.56)
Discharge Port A16/A22-F-R-02-K-A∗- 194 (7.64) 182. (7.17) 39 (1.54)
19(.75) Dia.
3280 205 (8.07) 193 (7.60) 39 (1.54)
View Arrow X A16/A22-F-R-02-K-D∗- 208 (8.19) 186.2 (7.33) 53 (2.09)
For other dimensions, refer to 32/3290 design.

1. Install the pump so that the "Filling Port" is at the Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd.
top.
A16/A22-F-R-02-K-∗-32 Rc 3/8 G 1/2 Rc 1/4
2. The pilot port provided is for connecting a control M10
valve, if multistage pressure control is required. A16/A22-F-R-02-K-∗-3280 3/8 BSP.F 1/4 BSP. Tr
A16/A22-F-R-02-K-∗-3290 3/8 NPT 1/2 NPT 1/4 NPT 3/8-16 UNC

DIMENSIONS IN MILLIMETRES (INCHES)

Side Port Type Foot Mounting Type


Port mounting dimensions are the same as those of pressure compensator Mounting bracket is common to that of pressure compensator model.
model. Refer to page 18 for port mounting dimensions. Refer to page 18 for the dimensions of mounting bracket.

No.30
"A" Series Piston Pumps
A37-∗-R-02 PISTON
PUMPS
A
Installation Drawing

Side Port Type


Flange Mtg. : A37-F-R-02-S-K∗-32/3290
Fully Extended
279.5(11.00)
Lock Nut 164.5 2
17(.67) Hex. (6.48) Pilot Port "PP2"
90 161.5 "E" Thd. 74
(3.54) (6.36) (2.91)
135 59(2.32) Electrical Conduit
Lock Nut 6 50
(5.31) Filling Port
1 Connection
14(.55) Hex. (.24) (1.97)
77 9.5 [22(.87) Hex. Head Plug Furnished] "D" Thd. (Both Ends)
(3.03) (.37)
30(1.18) Drain Port
"PP1"
"PP2" "C" Thd.

(7.85)
199.5
(7.13)
181
(5.87)
(11.40)

32(1.26) 6.38(.2512)
149
289.5

(4.76)
121

(4.13)
6.35(.2500)

105
(2.68)
68

(2.311)
58.7

(.55)

(.98)
25
14
101.55(3.998) Dia.
22.20(.8740) Dia.
25.01(.985)
24.85(.978)
R14(R.55)
101.60(4.000) 120(4.72) Dia.
22.23(.8752)

Front Side : Discharge Port 32(1.26) Dia. 146.5


30.2 12
Rear Side : Suction Port 32(1.26) Dia. (5.75)
(1.189) (.47)
178.5 174
"F" Thd. "H" Deep
(7.03) (6.85)
4 Places
202
(7.95)
2
Pilot Port "PP1"

A37-F-R-02-S-K∗-3280
"E" Thd.
13 26
Pressure Adj. (.51) (1.02)
Screw (PH) INC. Pressure Adj. Screw (PL) Cable Departure
14(.55) Hex. 14(.55) Hex. Cable Applicable:
6(.24) Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.)
Works at Solenoid Works at Solenoid INC.
De-energised Conductor Area ⋅⋅⋅⋅⋅⋅ Not Exceeding 1.5mm2(.002 Sq. IN.)
Energised 77.1
158
Flow Adj. Screw (6.22) (3.04)
5(.20) Hex. Soc. d 50
(1.97)
(6.50)
165

DEC.

a
b

86 86
(3.39) (3.39)
Surface of Surface of mm (IN.)
Suction Port Discharge Port Model Numbers
a b d
View Arrow X A37-F-R-02-S-K-A∗-3280 198 (7.80) 186 (7.32) 39 (1.54)
A37-F-R-02-S-K-D∗-3280 209 (8.23) 197 (7.76) 39 (1.54)
1. Install the pump so that the "Filling Port" is at the top. A37-F-R-02-S-K-R∗-3280 212 (8.35) 190.2 (7.49) 53 (2.09)
2. The pilot port provided is for connecting a control valve, if For other dimensions, refer to 32/3290 design.
multistage pressure control is required.

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" mm (IN.)
A37-F-R-02-S-K-∗-32 Rc 1/2 G 1/2 Rc 1/4
M10 19 (.75)
A37-F-R-02-S-K-∗-3280 1/2 BSP.F 1/4 BSP. Tr
A37-F-R-02-S-K-∗-3290 1/2 NPT 1/2 NPT 1/4 NPT 7/16-14 UNC 20 (.79)

DIMENSIONS IN MILLIMETRES (INCHES)

Axial Port Type Foot Mounting Type


Port mounting dimensions are the same as those of pressure Mounting bracket is common to that of pressure compensator model.
compensator model. Refer to page 19 for port mounting dimensions. Refer to page 19 for the dimensions of mounting bracket.

No.31
"A" Series Piston Pumps
A56-∗-R-02 PISTON
Installation Drawing
PUMPS
Side Port Type
Flange Mtg.: A56-F-R-02-S-K-∗-32/3290
Fully Extended
292(11.50)
Lock Nut 177
(6.97) 3
17(.67) Hex. Pilot Port "PP2"
90 174 "E" Thd.
(3.54) (6.85) 74
147.5 62(2.44) (2.91)
Lock Nut Electrical Conduit
(5.81) 6 50
14(.55) Hex. Connection
50.5(1.99) 9.5(.37) (.24) (1.97) "D" Thd. (Both Ends)
Filling Port 1
[22(.87) Hex. Head Plug Furnished]
43.5(1.71)
Drain Port 2
"PP1"
"C" Thd. (Both Sides) 4
"PP2" 41 49 4

(8.84)
224.5
(8.11)
206
40 7.97(.3138) (1.61) (1.93)
(6.85)
174

(5.75)
(12.70)

(1.57) 7.94(.3126)
322.5

X
146

(3.54)

(3.03)
58.7(2.311)
90

77

(.98)
(.55)

25
14
101.55(3.999) Dia.
31.70(1.2480) Dia.
35.32(1.391)
35.14(1.383)
R14(R.55)

101.60(4.000)
31.75(1.2500)

120(4.72) Dia. 146


Front Side : Discharge Port 30(1.18) Dia. 30.2 12
Rear Side : Suction Port 35(1.38) Dia. (1.189) (.47) (5.75)
207 174
(8.15) (6.85)
"F" Thd. "H" Deep 232
4 Places (9.13)

A56-F-R-02-S-K-∗-3280
3
13 26 Pilot Port "PP1"
Pressure Adj. (.51) (1.02) "E" Thd.
Screw (PH) INC. Pressure Adj. Screw (PL)
14(.55) Hex. Cable Departure
14(.55) Hex. 6(.24) Cable Applicable:
Works at Solenoid Works at Solenoid INC. Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.)
Energised De-energised Conductor Area ⋅⋅⋅⋅⋅⋅ Not Exceeding 1.5mm2(.002 Sq. IN.)
Flow Adj. Screw 170.5
5(.20) Hex. Soc. (6.71) 77.1
(7.48)

(3.04)
190

d
DEC. 50
(1.97)

a
b

100 100
(3.94) (3.94)
Surface of Surface of
Suction Port Discharge Port
View Arrow X
mm (IN.)
Model Numbers
1. Install the pump so that the "Filling Port" is at the top. a b d
2. Use either port of two drain ports at your option. A56-F-R-02-S-K-A∗-3280 223 (8.78) 211 (8.31) 39 (1.54)
A56-F-R-02-S-K-D∗-3280
Keep the remaining port plugged. Note that on the European
Design Standard (3280 Design), only the left side, as viewed 234 (9.21) 222 (8.74) 39 (1.54)
from the shaft end, of the drain port is machined. A56-F-R-02-S-K-R∗-3280 237 (9.33) 215.2 (8.47) 53 (2.09)
3. The pilot port provided is for connecting a control valve, if
multistage pressure control is required. For other dimensions, refer to 32/3290 design.

4. Dimensions show surface of drain port.

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" mm (IN.)
A56-F-R-02-S-K-∗-32 Rc 3/4 G 1/2 Rc 1/4
M10 19 (.75)
A56-F-R-02-S-K-∗-3280 3/4 BSP.F 1/4 BSP. Tr
A56-F-R-02-S-K-∗-3290 3/4 NPT 1/2 NPT 1/4 NPT 7/16-14 UNC 20 (.79)

DIMENSIONS IN MILLIMETRES (INCHES)

Axial Port Type Foot Mounting Type


Port mounting dimensions are the same as those of pressure compensator Mounting bracket is common to that of pressure compensator model.
model. Refer to page 20 for port mounting dimensions. Refer to page 20 for the dimensions of mounting bracket.

No.32
"A" Series Piston Pumps
A70-FR02 PISTON
PUMPS
A
Installation Drawing
Flange Mtg. : A70-FR02S∗-60/6090
Fully Extended
354.5(13.96) Pilot Port 3
239 "PP2" "E" Thd.
(9.41) Drain Port 2
Surface of 95 95
Surface of
90 236 "C" Thd. (Both Sides) Discharge Port (3.74) (3.74) Suction Port
(3.54) (9.29) 4 73 73
209.5
62(2.44) Surface of Surface of 4
Drain Port (2.87) (2.87) Drain Port
(8.25)
65 10
(2.56) (.39)
27(1.06) Dia.
9.5(.37) Spotface
40 (From Rear)
4 Places 7.97(.3138)

(9.33)
(8.60)
(1.57)

218.5

237
202.5
(7.97)
7.94(.3126)

186.5
(7.34)

14(.55)
X

(3.54)

18(.71)
Y

90
(2.063)

(4.508)
52.4

(7.09)
114.4

180

(4.65)
118
31.70(1.248) Dia.

126.95(4.998) Dia.
35.32(1.391)
35.14(1.383)

Discharge Port 35(1.38) Dia.


31.75(1.250)

127.00(5.000)

26(1.02) Thd. 19.5 Spotface


26.2 (.77) (From Rear)
"F" Thd. 114.4
(1.031) 16 2 Places
17(.67) Deep (4.508)
4 Places (.63) 134
18 (5.28)
(.71) 181
246.5 (7.13) Electrical Conduit
(9.70) 211 Connection
(8.31) "D" Thd. (Both Ends)
90
Pressure Adj. Screw (PH) 3 Eye Bolt
14(.55) Hex. (3.54) Pilot port "PP1"
66 "E" Thd. M10
1
Works at Solenoid
(2.60) Filling Port
Energised
10 Pressure Adj. Screw (PL) [22(.87) Hex. Head Plug Furnished]
(.39) 14(.55) Hex. Suction Port
INC.
Works at Solenoid INC. 38(1.50) Dia.
De-energised

(2.752)
69.9
Flow Adj. Screw
17(.67) Hex.
DEC.
5 "H" Thd. "J" Deep
View Arrow X Case Drain Port
4 Places
5(.20) Hex. Soc. 35.7
(1.406)
246.5
(9.70)
View Arrow Y
Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" Thd. "J" mm (IN.)
A70-FR02S∗-60 Rc 3/4 G 1/2 Rc 1/4
M10 M12 19 (.75)
A70-FR02S∗-6080 3/4 BSP.F 1/4 BSP. Tr
A70-FR02S∗-6090 3/4 NPT 1/2 NPT 1/4 NPT 7/16-14 UNC 1/2-13 UNC 21 (.83)

A70-FR02S∗-6080 1. Install the pump so that the "Filling Port" is at the top.
Cable Departure 2. Use either port of two drain ports at your option.
Cable Applicable: Keep the remaining port plugged. Note that on the European
Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.) Design Standard (6080 Design), only the left side, as viewed
Conductor Area ⋅⋅⋅⋅⋅⋅ Not Exceeding 1.5mm2(.002 Sq. IN.) from the shaft end, of the drain port is machined.
232.5 93.1
(9.15)
3. The pilot port provided is for connecting a control valve, if
(3.67) multistage pressure control is required.
d 66
(2.60) 4. Dimensions show surface of drain port.
5. Case drain port is available for use when draining hydraulic
fluid from pump casing.
a
b

DIMENSIONS IN
MILLIMETRES (INCHES)
mm (IN.)
Model Numbers
a b d Foot Mounting Type
A70-FR02SA∗-6080 236 (9.29) 224 (8.82) 39 (1.54) Mounting bracket is common to that of pressure
compensator model. Refer to page 21 for the dimensions
A70-FR02SD∗-6080 247 (9.72) 235 (9.25) 39 (1.54)
of mounting bracket.
A70-FR02SR∗-6080 250 (9.84) 228.2 (8.98) 53 (2.09)
For other dimensions, refer to 60/6090 design.

No.33
"A" Series Piston Pumps
A90-FR02 PISTON
Installation Drawing
PUMPS
Flange Mtg.: A90-FR02S∗-60/6090
2
Surface of Surface of
Drain Port Discharge Port 105 105 Suction Port
"C" Thd. (Both Sides) (4.13) (4.13)
4 4
Surface of 68 68
263.5 95 Surface of
(10.37) Drain Port (2.68) (2.68) Drain Port
(3.74) 2.5 53.5
119.5 23(.91) 3
Pilot Port (.1) (2.11) 9.56(.3764)
(4.70) "PP2" "E" Thd. 9.53(.3752)
13(.51)

63(2.48)

(9.70)
246.5
(8.94)
(8.35)

227
(7.72)
212

(7.09)
196

180
(4.45)
X

113
Y

(6.362)
(2.311)

161.6
58.7

(5.00)
127
Discharge Port
38.05(1.498) Dia.

152.35(5.998) Dia.
42.36(1.668)
42.18(1.661)
32(1.26) Dia.
38.10(1.500)

152.40(6.000)

22 21.5 (.85) Dia. Through R22(R.87)


30.2 39(1.54) Dia. Spotface 161.6
(.87)
(1.189) 23 (From Rear) (6.362)
"F" Thd. 4 Places
"J" Deep (.91)
4 Places 270
(10.63)
5
Case drain Port
5(.20) Hex. Soc. Fully Extended
3
Pilot Port "PP1" Eye Bolt 379(14.92)
22.5 M10
(.89) "E" Thd. 260.5 90
1
(10.26) (3.54) Electrical Conduit Connection
2.5 Filling Port
[27(1.06) Hex. Head Plug Furnished] "D" Thd. (Both Ends)
Pressure Adj. Screw (PH) (.10)
14(.55) Hex.
Works at Solenoid INC. Pressure Adj. Screw (PL)
Energised 14(.55) Hex.

(7.72)
196
(6.61)
Works at Solenoid

168
INC.
De-energised

(3.46)
88
(3.063)
77.8
Flow Adj. Screw
17(.67) Hex. Soc. Suction Port
DEC. 48(1.89) Dia.
View Arrow X
42.9
(1.689) "H" Thd. "K" Deep
270 4 Places
(10.63)

View Arrow Y
Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" Thd. "J" mm (IN.) "K" mm (IN.)
A90-FR02S∗-60 Rc 3/4 G 1/2 Rc 1/4
M10 M12 19 (.75) 19 (.75)
A90-FR02S∗-6080 3/4 BSP.F 1/4 BSP. Tr
A90-FR02S∗-6090 3/4 NPT 1/2 NPT 1/4 NPT 7/16-14 UNC 1/2-13 UNC 20 (.79) 21 (.83)

A90-FR02S∗-6080 1. Install the pump so that the "Filling Port" is at the top.
Cable Departure
2. Use either port of two drain ports at your option.
Cable Applicable: Keep the remaining port plugged. Note that on the European
Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.) Design Standard (6080 Design), only the left side, as viewed
Conductor Area ⋅⋅⋅⋅⋅⋅ Not Exceeding 1.5mm2(.002 Sq. IN.) from the shaft end, of the drain port is machined.
257.5 56.6(2.23) 3. The pilot port provided is for connecting a control valve, if
(10.14) multistage pressure control is required.
d 53.5 4. Dimensions show surface of drain port.
(2.11)
5. Case drain port is available for use when draining hy-
draulic fluid from pump casing.
a
b

DIMENSIONS IN
MILLIMETRES (INCHES)
mm (IN.)
Model Numbers Foot Mounting Type
a b d
Mounting bracket is common to that of pressure
A90-02FRSA∗-6080 245 (9.65) 233 (9.17) 39 (1.54)
compensator model. Refer to page 22 for the dimensions
A90-02FRSD∗-6080 256 (10.08) 244 (9.61) 39 (1.54) of mounting bracket.
A90-02FRSR∗-6080 259 (10.20) 237.2 (9.34) 53 (2.09)
For other dimensions, refer to 60/6090 design.

No.34
"A" Series Piston Pumps
A145-FR02 PISTON
PUMPS
A
Installation Drawing
Flange Mtg. : A145-FR02S∗-60/6090

Surface of Surface of
Fully Extended 112 Discharge Port 112 112 Suction Port
400.5(15.77) (4.41) (4.41) (4.41)
285 23(.91) 4 4
72 72
(11.22) Surface of Surface of
2 Drain Port (2.83) (2.83) Drain Port
255.5 13(.51) Drain Port "C" Thd. 3
12 11.14(.4386)
(10.06) (Both Sides) Pilot Port (.47) 11.11(.4374)
89 "PP2" "E" Thd.
(3.50) 70(2.76)

(9.78)
248.5
(8.43)

(7.80)
X

214

198
(4.33)
110

(9.000)
(2.311)

228.6
58.7

(5.55)
141
Discharge Port
152.35(5.998) Dia.
44.40(1.748) Dia.
49.39(1.944)
49.21(1.937)

32(1.26) Dia.
44.45(1.750)

152.40(6.000)

"F" Thd. 21.5(.85) Dia. Through


30.2 24 228.6 R22(R .87)
"J" Deep 39(1.54) Dia. Spotface
4 Places (1.189) (.94) (From Rear) (9.000)
26 4 Places 273
(10.75) Electrical Conduit
5 (1.02)
Case Drain Port 299.5 Connection
5(.20) Hex. Soc. "D" Thd. (Both Ends)
(11.79)
Eye Bolt
281.5 90
M10
(11.08) (3.54)

3 1
Pressure Adj. Screw (PH) Pilot Port "PP1" Filling Port
14(.55) Hex. 68 "E" Thd. [27(1.06) Hex. Head Plug Furnished]
(2.68)
Works at Solenoid INC. Suction Port
Energised 12
(.47) Pressure Adj. Screw (PL) 48(1.89) Thd.

(3.063)
14(.55) Hex.

77.8
Works at Solenoid INC.
De-energised
Flow Adj. Screw
(9.06)
230

"H" Thd. "K" Deep


17(.67) Hex. Soc.
4 Places
DEC.
42.9
(1.689)
299.5
(11.79)
View Arrow X
View Arrow Y

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" Thd. "J" mm (IN.) "K" mm (IN.)
A145-FR02S∗-60 Rc 3/4 G 1/2 Rc 1/4
M10 M12 19 (.75) 19 (.75)
A145-FR02S∗-6080 3/4 BSP.F 1/4 BSP. Tr
A145-FR02S∗-6090 3/4 NPT 1/2 NPT 1/4 NPT 7/16-14 UNC 1/2-13 UNC 20 (.79) 21 (.83)

A145-FR02S∗-6080 1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of two drain ports at your option.
Cable Departure Keep the remaining port plugged. Note that on the European
Cable Applicable:
Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.) Design Standard (6080 Design), only the left side, as viewed
Conductor Area ⋅⋅⋅⋅⋅⋅ Not Exceeding 1.5mm2(.002 Sq. IN.) from the shaft end, of the drain port is machined.
92(3.62) 3. The pilot port provided is for connecting a control valve, if
278 multistage pressure control is required.
(10.94)
d 68 4. Dimensions show surface of drain port.
(2.68)
5. Case drain port is available for use when draining hydraulic
fluid from pump casing.
a
b

DIMENSIONS IN
MILLIMETRES (INCHES)
mm (IN.)
Model Numbers
a b d Foot Mounting Type
A145-FR02SA∗-6080 247 (9.72) 235 (9.25) 39 (1.54) Mounting bracket is common to that of pressure
compensator model. Refer to page 23 for the dimensions
A145-FR02SD∗-6080 258 (10.16) 246 (9.69) 39 (1.54)
of mounting bracket.
A145-FR02SR∗-6080 261 (10.28) 239.2 (9.42) 53 (2.09)
For other dimensions, refer to 60/6090 design.

No.35
"A" Series Piston Pumps
PISTON
Variable Displacement-Single Pumps
Pressure Compensator with Unloading Type
A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Specifications

Graphic Symbol Performance Characteristics

Output Flow
SOL SOL
"OFF" "ON"

M
O

Pressure

Specifications
Geometric Minimum Shaft Speed
Operating Pres.
Displacement Adj. Flow Unloading Pres. Range
Model Numbers MPa (PSI)
cm3/rev cm3/rev MPa (PSI) r/min
(cu. in. /rev) (cu. in. /rev) Rated Intermittent Max. Min.

A16-∗-R-03-∗-K-∗-32∗
15.8 4 16 21 1.2
1800 600
(.964) (.244) (2320) (3050) (170)

A22-∗-R-03-∗-K-∗-32∗
22.2 6 16 16 1.2
1800 600
(1.355) (.366) (2320) (2320) (170)

A37-∗-R-03-∗-K-∗-32∗
36.9 10 16 21 1.2
1800 600
(2.25) (.61) (2320) (3050) (170)

A56-∗-R-03-∗-K-∗-32∗
56.2 12 16 21 1.2
1800 600
(3.43) (.73) (2320) (3050) (170)

A70-∗R03S∗-K-60∗
70.0 30 25 25 1.2
1800 600
(4.27) (1.83) (3630) (3630) (170)

A90-∗R03S∗-K-60∗
91.0 56 25 25 1.2
1800 600
(5.55) (3.42) (3630) (3630) (170)

A145-∗R03S∗-K-60∗
145 83 25 25 1.2
1800 600
(8.85) (5.06) (3630) (3630) (170)
Consult YUKEN for details.

No.36
"A" Series Piston Pumps
Variable Displacement-Single Pumps
PISTON
A
Proportional Electro-Hydraulic Load-Sensing Type
A16 / A22 / A37 / A56 / A70 / A90 / A145
PUMPS
Model Number Designation

Graphic Symbols
i1

i2

Performance Characteristics

i1

i → Large)
M

Output Flow
i2

2
O

(Small ← Current
Input
A16/A22/A37
i1

i2
Pressure
(Small ← Input
Current i 1 →
M Large)
O

A70/A90/A145

M
O

A56

Model Number Designation


A56 -F -R -04 -C -K -32 ∗
Direction of Pres. Adj. Range Shaft Design
Series Number Mounting Control Type Design Std.
Rotation MPa (PSI) Extension Number

A16 B: 1.5 - 7 (220 - 1020)


Viewed from C: 1.5 - 16 (220 - 2320) 32
(15.8 cm3/rev) Shaft End H: 1.5 - 21 (220 - 3050)
A22 F: B: 1.5 - 7 (220 - 1020)
04: 32
(22.2 cm3/rev) Flange Mtg. C: 1.5 - 16 (220 - 2320)
Proportional K: Refer to 2
A37 1 Electro-Hydraulic Keyed Shaft
L: R: Load Sensing 32
(36.9 cm3/rev) Foot Mtg. Clockwise B: 2 - 7 (290 - 1020)
C: 2 - 16 (290 - 2320)
A56 H: 2 - 21 (290 - 3050)
32
(56.2 cm3/rev)

A70 -F R 04 C S -60 ∗
Direction of Pres. Adj. Range Design
Series Number Mounting Control Type Port Position Design Std.
Rotation MPa (PSI) Number

A70 Viewed from 60


(70.0 cm3/rev) Shaft End
F: 04:
Flange Mtg.
A90 Proportional C: 1.5 - 16 (220 - 2320) S:
60 Refer to 2
(91.0 cm3/rev) 1 Electro-Hydraulic H: 1.5 - 21 (220 - 3050) Side Port
L: R: Load Sensing
Foot Mtg. Clockwise
A145
60
(145 cm3/rev)

1. Available to supply pump with anti-clockwise rotation. Consult 2. Design Standards: None ........... Japanese Standard "JIS"
Yuken for details. 80 ............... European Design Standard
90 ............... N. American Design Standard

No.37
"A" Series Piston Pumps
Proportional Electro-Hydraulic Load-Sensing Type PISTON
A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Pipe Flange Kits / Instructions

Pipe Flange Kits


Pipe flange kits are available.
When ordering, specify the kit nuneber from the table below.
Pipe Flange Kit Numbers
1
Threaded Connection Socket Welding Butt Welding
Pump Model Name of
Numbers Port Japanese European N. American Japanese Standard N. American Japanese Standard N. American
Standard Design Design "JIS" & Design "JIS" & Design
European Design European Design
"JIS" Standard Standard Standard Standard Standard Standard

A16-∗-R-04 Suction F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090


A22-∗-R-04 Discharge 2 2 2 2 2 2 2

A37-∗-R-04 Suction F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090


A56-∗-R-04 Discharge F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090
Suction F5-12-A-10 F5-12-A-1080 F5-12-A-1090 F5-12-B-10 F5-12-B-1090 F5-12-C-10 F5-12-C-1090
A70-∗R04
Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090

A90-∗R04 Suction F5-16-A-10 F5-16-A-1080 F5-16-A-1090 F5-16-B-10 F5-16-B-1090 F5-16-C-10 F5-16-C-1090


A145-∗R04 Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090

1. In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength
of the flanges. Therefore, please pay cautious attension to the operating pressure when the socket welding flanges are used.
2. Discharge port for pump model "A16" and "A22" is available only the threaded connections.
Detail of the pipe flange kits are given in the Catalogue No. Pub. EC-3001.

Instructions
Bleeding Air
In order to get steadily controlled pressure and flow, bleed air by loosening the air vent screw and fill solenoid armature
with operating oil.
Manual Adjustment Screws
Manual adjustment screws may be used for initial running adjustment or in case of electrical failures in order to adjust pressure and
flow temporarily. In case of normal use, put the manual adjustment screws back in their preset positions.

Position of Cable Departure


Position of cable departure can be changed. For details, refer to EDG-01 valve Catalogue No. Pub. EC-1302.

Connection of Surge Cut-off Valve to "A" Series Pump (For A16 to A56 Type)
If using surge cut-off valve (SF1105-A-10), connect between pilot port "PP" of this pump and port "PP" of surge cut-off valve as
pilot piping (refer to drawing below).
Inside diameter of pipe should be more than 8 mm(.32 in.).
Consult Yuken of detail of surge cut-off valve.

Surge Cut-off Valve


(SF1105-A-10)

i1
"PP"

i2

M
O

No.38
"A" Series Piston Pumps
Proportional Electro-Hydraulic Load-Sensing Type PISTON A
A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Specifications

Model No. A16 A22 A37 A56 A70 A90 A145


Descriptions
3
Geometric cm /rev 15.8 22.2 36.9 56.2 70.0 91.0 145
Displacement (cu. in./rev) (.964) (1.355) (2.25) (3.43) (4.27) (5.55) (8.85)
2 16 16 16 16 21 21 21
Rated
(2320) (2320) (2320) (2320) (3050) (3050) (3050)
Operating Pres.
MPa (PSI)
1 21 16 21 21 21 21 21
Intermittent
(3050) (2320) (3050) (3050) (3050) (3050) (3050)

Shaft Speed Range Max. 1800 1800 1800 1800 1800 1800 1800
r/min Min. 600 600 600 600 600 600 600
Flow Adj. L /min 1 - 28.4 1 - 40 1 - 66 1 - 101 1 - 126 1 - 163 2 - 261
Range (U.S. GPM) (.26 - 7.5) (.26 - 10.6) (.26 - 17.4) (.26 - 26.7) (.26 - 33.3) (.26 - 43.1) (.53 - 69.0)

Min Pres. Required MPa 1.5 1.5 1.5 2.0 1.0 1.0 1.0
for Flow Adj. (PSI) (220) (220) (220) (290) (145) (145) (145)

Differential Pres.
MPa 0.37 0.22
(Discharge Pres.
(PSI) (55) (30)
Flow -Load Pres.)
Control
Step Response 5
ms 70 80 120 125 100 120 210
(0 → Max. Flow)
4
Hysteresis Less than 3%
Rated Current mA 900 700 740 790 820 920 920
Coil Resistance
[20°C (68°F)] Ω 10

Pres. Adj. Range MPa (PSI) Refer to Model Number Designation


Step t1 5
80 80 50 55 150 150 160
Response 5
ms t2 140 90 80 80 80 120 180
4
Pres. Hysteresis Less than 2%
Control
(Pres. Adj. Range) C: 860 C: 873 C: 875
Rated Current mA
B: 770, C:880, H:790 H: 765 H: 765 H: 755

Coil Resistance
[20°C (68°F)] Ω 10

Applicable Amplifier Model 3


AME-D2-1010-∗-10
32 32 38 45 72.5 88.5 109.5
Flange Mtg.
Approx. Mass (70.6) (70.6) (83.8) (99.2) (160) (195) (241)
kg
(lbs.) 34.2 34.2 43.2 49.3 84.5 109 134.5
Foot Mtg.
(75.4) (75.4) (95.3) (109) (186) (240) (297)

1. Whenever setting pressure, make sure the full cut-off pressure never
exceeds the maximum intermittent pressure.
2. When operating the pump exceeding the rated pressure, operating Pres. Step Response
Model Loading Volume
conditions are restricted. Refer to page 6 for the details. t1 t2
3. For detail specifications of power amplifiers, refer to Catalogue No. 1.5 → 16 MPa 16 → 1.5 MPa High Pressure Hose
A16, A22
Pub. EC-1305. (220 → 2320 PSI) (2320 → 220 PSI) 3/8" × 2 m (6.6 ft)
4. The figure mentioned in the above table are those obtained using
Yuken's amplifier. 2.0 → 16 MPa 16 → 2.0 MPa High Pressure Hose
A37, A56
(290 → 2320 PSI) (2320 → 290 PSI) 3/4" × 2 m (6.6 ft)
5. Step response depends on circuit and operating conditions. Data
shown in the table above is an example based on the condition right. A70, A90 3.0 → 16 MPa 16 → 3.0 MPa High Pressure Hose
A145 (435 → 2320 PSI) (2320 → 435 PSI) 1-1/4" × 2 m (6.6 ft)

No.39
"A" Series Piston Pumps
Proportional Electro-Hydraulic Load-Sensing Type PISTON
A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Typical Pump Characteristics

Typical Performance Characteristics at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)]

Full Cut-off Pres. vs. Input Current


A16/A22/A37/A56 A70/A90/A145
PSI MPa
PSI MPa 3500 24
3000 21 3000
20 20
"H"
Full Cut-off Pressure

Full Cut-off Pressure


2500 2500 "H"
16 16
2000 "C" 2000
12 12
1500 1500 "C"
8 8
1000 1000
4 "B" 4
500 500
0 0
0 0
0 200 400 600 800 900 0 200 400 600 800 1000
Input Current mA Input Current mA

Note: Pressure adjustment range "H" is not available for A22.

Output Flow vs. Input Current A22


U.S.GPM L /min
A16 11
40
N=1800 r/min
10
U.S.GPM L /min N=1800 r/min
32
8 8 30
Output Flow 6
24 20
6 4
Output Flow

10
2
4 16 0
0
0 200 400 600 800

8 Input Current mA
2
A56
0
0 U.S.GPM L /min
0 200 400 600 800 1000 30 N=1800 r/min
110
Input Current mA 25
100
Output Flow

20 80

A37 15 60

10 40
U.S.GPM L /min N=1800 r/min
18 70 5 20
0
16 60 0
0 200 400 600 800 900
14
50 Input Current mA
12
Output Flow

10 40 A70
8 30 U.S.GPM L /min N=1800 r/min
6 35 140
20
4 30 120
Output Flow

10
2 80
0 20
0
0 200 400 600 800 40
10
Input Current mA
0 0
0 200 400 600 800 1000
Input Current mA
A90
U.S.GPM L /min N=1800 r/min A145
200
50 U.S.GPM L /min N=1800 r/min
75 280
160 70
40
240
Output Flow

120 60
30
200
50
Output Flow

20 80
160
40
10 40 120
30
0
0 20 80
0 200 400 600 800 1000
Input Current mA 10 40
0
0
0 200 400 600 800 1000
Input Current mA

No.40
"A" Series Piston Pumps
A16 / A22-F-R-04 PISTON
PUMPS
A
Installation Drawing
Flange Mtg : A16-F-R-04-∗-K-32/3280/3290
A22-F-R-04-∗-K-32/3280/3290
229 44.5(1.75)
(9.02)
213 6.5(.26)
2
Cable Departure (8.39) Filling Port
(For Pres. Control) 167.5 [22(.87) Hex. Head Plug Furnished] 101.5
(6.59) (4.00)
59(2.32) 63.2
Drain Port
"C" Thd. (2.49)
26.5(1.04)

25(.98)
(6.99)
177.5

4.79(.1886)
(6.00)
152.5

4.76(.1874)
X
(10.06)

(3.78)
255.5

96
(2.26)
57.5

(.47)

(.71)
12

18
82.50(3.248) Dia.
19.02(.7488) Dia.
21.24(.836)
21.08(.830) R12
82.55(3.250)
95(3.74) Dia.
19.05(.7500)

12 (R.47)
(.47) 106
172 (4.17)
(6.77) 130
Surface of Suction Port (5.12)
187 188
Pressure Gauge Connection (7.36) (7.40)
for Pump Discharge Pressure
262
"D" Thd (10.31) Pilot Port "PP"
Surface of Discharge Port 152.2 "D" Thd.
(5.99) 2
Cable Departure
Tank Port 70 (For Flow Control)
Air Vent "F" Thd. (2.76)
3 (.12) Hex. Soc.
Manual Pressure Adj. Screw
3 (.12) Hex. Soc. Manual Pressure Adj. Screw
3(.12) Hex. Soc.
INC. 41
Safety Valve Pressure Adj. Screw (1.61) INC.
17(.67) Hex. Soc.
(4.06)
103
(2.26)

INC.
57.5
(1.89)
48

(1.874)
47.6

Air Vent 3(.12) Hex.


Suction Port 19(.75) Dia. 3 Places.
22.2(.874) 56
(2.20) Discharge Port
32.5 85 "E" Thd.
"H" Thd. 17(.67) Deep
(1.28) (3.35)
4 Places
94 190.5
See 3
(3.70) (7.50)
View Arrow X
Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" Thd.
A16/A22-F-R-04-∗-K-32 Rc 3/8 Rc 1/4 G 3/8 1
Rc 1/4
M10
A16/A22-F-R-04-∗-K- 3/8 BSP.F 1/4 BSP.Tr 3/8 BSP.F 1/4 BSP.F
3280 3/8 NPT 1/4 NPT 3/8 NPT 1/4 NPT 3/8-16 UNC

1. Detail of Discharge Ports 2. Cable Applicable:


[For Japanese Standard] Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)
14 3. Do not touch the screw because it is adjusted at the time of shipment.
(.55)
1 2.5
(.04) (.10)

G 3/8 Thd.
18.6(.73) Dia. 15°
28(1.10) Dia.

DIMENSIONS IN
MILLIMETRES (INCHES)

Foot Mounting Type


Mounting bracket is common to that of pressure compensator model.
Refer to page 18 for the dimensions of mounting bracket.

No.41
"A" Series Piston Pumps
A37-F-R-04 PISTON
Installation Drawing
PUMPS
Flange Mtg. : A37-F-R-04-∗-K-32/3280/3290
Manual Pressure Adj. Screw
3(.12) Hex. Soc.
Air Vent 3(.12) Hex. INC.
308.5 59 3 Places.
Air Vent 3(.12) Hex.
3 Places. (12.15) (2.32)
Cable Departure 1
296.5 9.5
(For Pres. Control)
(11.67) (.37)
Manual Flow Adj. Screw 110.5
3(.12) Hex. Soc. (4.35)
INC. 77 Filling Port
[22(.87) Hex. Head Plug Furnished] 77.3
(3.03) Safety Valve
30(1.18) (3.04)
Pressure Adj. Screw
Drain Port 3(.12) Hex. Soc.
"C" Thd. INC.
(7.30)
185.5

6.38(.2512)
(5.80)
147.2

32(1.26)

(5.20)
6.35(.2500)

132
(4.13)
(10.85)

105
275.5

(.55)
14
(.28)

(.98)
7

25
101.55(3.998) Dia.
22.20(.8740) Dia.
25.01(.985)
24.85(.978)
R14
12 120(4.72) Dia.

101.60(4.000)
22.23(.8752)

(R .55)
(.47) 146
195 (5.75)
Pressure Gauge
(7.68) 174
Connection for Pump
Surface of Suction Port (6.85)
Discharge Pressure 228
"D" Thd (8.98) 202
282 (7.95)
(11.10)
Surface of Discharge Port

100.5 115.5
(3.96) (4.55)
27
Pilot Port "PP" (1.06) Cable Departure 1 1. Cable Applicable:
"D" Thd. (For Flow Control) Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)
(3.35)
85

(2.311)

(1.874)
58.7

47.6

Discharge Port
Suction Port 20(.79) Thd.
32(1.26) Dia. 30.2 22.2 "F" Thd. 19(.75) Deep
"E" Thd. "H" Deep (1.189) (.874) 4 Places
4 Places 36 42
(1.42) (1.65)
83
(3.27)
View Arrow X
Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" mm (IN.)
A37-F-R-04-∗-K-32 Rc 1/2 Rc 1/4
M10 M10 19 (.75)
A37-F-R-04-∗-K-3280 1/2 BSP.F 1/4 BSP.Tr
A37-F-R-04-∗-K-3290 1/2 NPT 1/4 NPT 7/16-14 UNC 3/8-16 UNC 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg. : A37-L-R-04-∗-K-32/3280/3290 14(.55) Dia. Through
28(1.10) Dia. Spotface
4 Places
(4.02)
(.59)
(.55)

102
15
14
(.12)
3

60 74 120
(2.362) (2.91) (4.72)
115 39 95 95
(4.53) (1.54) (3.740) (3.740)
230
(9.06)
For other dimensions, refer to "Flange Mtg.".

No.42
"A" Series Piston Pumps
A56-F-R-04 PISTON
PUMPS
A
Installation Drawing
Flange Mtg. : A56-F-R-04-∗-K-32/3280/3290
Manual Pressure Adj. Screw
62 3(.12) Hex. Soc.
320.5 (2.44)
Air Vent 3(.12) Hex. INC.
(12.62) Air Vent
3 Places. 308.5 9.5 3(.12) Hex.
(12.15) (.37) 3 Places. 77.8
122.5 (3.06)
Cable Departure 1
Manual Flow Adj. Screw (4.82) (For Pres. Control) Surface of Drain Port
3(.12) Hex. Soc. 50.5
(1.95) 41 49 Safety Valve
INC. Filling Port
43.5 (1.61) (1.93) Pressure Adj. Screw
[22(.87) Hex. Head Plug Furnished]
(1.71) 40 3(.12) Hex. Soc.
(1.57) INC.
2
Drain Port (Both Sides) 7.97(.3138)
(7.30)
185.5

"C" Thd.
(5.80)
147.2

7.94(.3126)
(11.16)

X
283.5

(.28)

(3.54)
7

90

(.55)

(.98)
14

25
31.70(1.248) Dia.

101.55(3.998) Dia.
35.32(1.931)
35.14(1.383) R14
31.75(1.250)

101.60(4.000) (R.55)
12 120(4.72) Dia. 146
Pressure Gauge Connection
(.47) (5.75)
for Pump Discharge Pressure
"D" Thd 240 174
(9.45) (6.85)
Surface of Suction Port 232
240 (9.13)
(9.45)
294
(11.57)
Surface of Discharge Port
100 116
(3.94) (4.57)
27 Cable Departure 1
Pilot Port "PP"
(1.06) (For Flow Control)
"D" Thd.
1. Cable Applicable:
Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)
2. Use either port of two pilot and drain ports at your option. Keep the
(3.70)
94

remaining port plugged. Note that on the European Design Standard


(1.874)
(2.311)
58.7

47.6

(3280 Design), only the left side, as viewed from the shaft end, of the
drain port is machined.
Suction Port Discharge Port
35(1.38) Dia. 20(.79) Thd.
"F" Thd. "H" Deep
30.2 22.2 4 Places
"E" Thd. "H" Deep
4 Places (1.189) (.874)
38 44
(1.50) (1.73)
85
(3.35)
View Arrow X Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" mm (IN.)
A56-F-R-04-∗-K-32 Rc 3/4 Rc 1/4
M10 M10 19 (.75)
A56-F-R-04-∗-K-3280 3/4 BSP.F 1/4 BSP.Tr
A56-F-R-04-∗-K-3290 3/4 NPT 1/4 NPT 7/16-14 UNC 3/8-16 UNC 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg. : A56-L-R-04-∗-K-32/3280/3290
14(.55) Dia. Through
28(1.10) Dia. Spotface
4 Places
(4.02)
(.55)

(.59)
102
14

15
(.12)
3

60 77 120
(2.362)(3.03) (4.72)
115 42 95 95
(4.53) (1.65) (3.740) (3.740)
230
(9.06)
For other dimensions, refer to "Flange Mtg.".

No.43
"A" Series Piston Pumps
A70-FR04 PISTON
Installation Drawing
PUMPS
Flange Mtg. : A70-FR04∗S-60/6080/6090

Cable Departure 3
Manual Pressure (For Pres. Control) Surface of
Adj. Screw Drain Port
INC. 344.5 Drain Port (Both Sides) 1
3 (.12) Hex. Soc. 196.5
(13.56) "C" Thd. Safety Valve
Air Vent Pilot Port (7.74) Pressure Adj. Screw
227.5
3 (.12) Hex. Soc. "D" Thd. 169 3 (.12) Hex. Soc.
(8.96)
3 Places (6.65) INC.
196.5 62
Secondary Pressure 140 95 Surface of Suction Port
Manual Flow (7.74) (2.44) Gauge Connection (5.51) (3.74)
Adj. Screw INC. 191.5 for Pump Discharge 104.3
3 (.12) Hex. Soc. (7.54) Pressure (4.11)
Air Vent 137 19.5 "D" Thd.
3 (.12) Hex. Soc. (5.39) (.77) 73 73

127.00 (5.000)
126.95 (4.998)
3 Places (2.87) (2.87)

Dia.
65 9.5
3
Cable Departure (2.56) (.37)

31.75 (1.250)
31.70 (1.248)
35.32 (1.391)
35.14 (1.383)
(For Flow Control)
40 7.97 (.3138)
Tank Port 7.94 (.3126)

(7.74)
(1.57)

196.5
137(5.39)
120(4.72)
"H" Thd.

14(.55)
(3.54)
(3.27)

90
X
83

180(7.09)
18(.71)

(4.50)
114.4
(1.97)

14(.55)
50

(4.65)
(1.189)

118
30.2

35 (1.38) Dia.
16(.63) Spotface
Primary Pressure (From Rear)
18(.71) 114.4
Gauge Connection for 58.7 2 Places
(4.50)
Pump Discharge Pressure (2.311)
"D" Thd. 27 (1.06) Dia. 134
215 Spotface (5.28)
"F" Thd. "K" Deep (8.46) (From Rear) 181
4 Places 276 4 Places (7.13)
(10.87) 211
Discharge Port
25 (.98) Dia. (8.31)

1
Filling Port Eye Bolt
[22 (0.87) Hex. Head plug Furnished] M10

Suction Port
38 (1.50) Dia.

(2.752)
69.9

"E" Thd. "J" Deep


4 Places

35.7
1. Use either port of two pilot and drain ports at your option. Keep the (1.406)
246.5
remaining port plugged. Note that on the European Design Standard (9.70)
Case Drain Port 2
(6080 Design), only the left side, as viewed from the shaft end, of
5 (.20) Hex. Soc.
the drain port is machined.
2. Case drain port is available for use when draining hydraulic fluid
from pump casing. View Arrow X
3. Cable Applicable:
Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" Thd. J mm (IN.) K mm (IN.)
A70-FR04∗S-60 Rc 3/4 Rc 1/4 Rc 3/8
M12 M10 19 (.75) 17 (.67)
A70-FR04∗S-6080 3/4 BSP.F 1/4 BSP. Tr 3/8 BSP. F
A70-FR04∗S-6090 3/4 NPT 1/4 NPT 1/2-13 UNC 7/16-14 UNC 3/8 NPT 21 (.83) 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)

Foot Mounting Type


Mounting bracket is common to that of pressure compensator model.
Refer to page 21 for the dimensions of mounting bracket.

No.44
"A" Series Piston Pumps
A90-FR04 PISTON
PUMPS
A
Installation Drawing

Flange Mtg. : A90-FR04∗S-60/6080/6090


Cable Departure 3
Manual Pressure (For Pres. Control)
370.5
Adj. Screw INC. Surface of Drain Port
(14.59)
3 (.12) Hex. Soc.
251 206.5 Safety Valve
Air Vent (9.88) 1 (8.13) Pressure Adj. Screw
3 (.12) Hex. Soc. Drain Port (Both Sides) 3(.12) Hex. Soc.
220 "C" Thd. 179
3 Places
(8.66) (7.05) INC.
Manual Flow
INC. 215 150 105
Adj. Screw Surface of Suction Port
3 (.12) Hex. Soc. (8.46) (5.91) (4.13)
160.5 95 68 68
Air Vent (6.32) (3.74) (2.68) (2.68)
3 (.12) Hex. Soc. Pilot Port
119.5 23(.91) "D" Thd. 104.3
3 Places
(4.70) (4.11)
13(.51) Secondary Pressure Gauge
3
Cable Departure Connection for Pump
(For Flow Control) Discharge Pressure
63(2.48) "D" Thd.
30.2(1.189)

(8.11)
9.56 (.3764)

206
50(1.97)
(5.39)
9.53 (.3752)

(4.72)
137
(4.45)

120
113
(3.27)
83

(6.362)
X

161.6
(5.00)
127
Tank Port
38.05(1.498) Dia.

152.35(5.998) Dia.
42.36(1.668)
42.18(1.661)

"H" Thd.
Primary Pressure
152.40(6.000)
38.1(1.500)

Gauge Connection for 22 21.5(.85) Dia. Through


58.7 161.6 R22
Pump Discharge Pressure (.87) 39(1.54) Dia. Spotface
(From Rear) (6.362) (R .87)
"D" Thd. (2.311) 23
"F" Thd. "K" Deep (.91) 4 Places
4 Places 238.5
Discharge Port (9.39)
25 (.98) Dia. 299.5 Filling Port 1
(11.79) [27(1.06) Hex. Head Plug Furnished]
2
Case Drain Port
5 (.20) Hex. Soc. Eye Bolt
M10

Suction Port
48(1.89) Thd.
(3.063)
77.8

"E" Thd. "J" Deep


4 Places
42.9
(1.689)
270
(10.63)
1. Use either port of two pilot and drain ports at your option. Keep the
remaining port plugged. Note that on the European Design Standard
(6080 Design), only the left side, as viewed from the shaft end, of View Arrow X
the drain port is machined.
2. Case drain port is available for use when draining hydraulic fluid
from pump casing.
3. Cable Applicable:
Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" Thd. J mm (IN.) K mm (IN.)
A90-FR04∗S-60 Rc 3/4 Rc 1/4 Rc 3/8
M12 M10 19 (.75) 17 (.67)
A90-FR04∗S-6080 3/4 BSP.F 1/4 BSP. Tr 3/8 BSP. F
A90-FR04∗S-6090 3/4 NPT 1/4 NPT 1/2-13 UNC 7/16-14 UNC 3/8 NPT 21 (.83) 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mounting Type
Mounting bracket is common to that of pressure compensator model. Refer
to page 22 for the dimensions of mounting bracket.

No.45
"A" Series Piston Pumps
A145-FR04 PISTON
Installation Drawing
PUMPS
Flange Mtg. : A145-FR04∗S-60/6080/6090
Manual Pressure Cable Departure 3
Adj. Screw (For Pres. Control) Surface of Drain Port
1
3 (.12) Hex. Soc. 400 Drain Port (Both Sides) Air Vent
(15.75) "C" Thd. 216.5
3 (.12) Hex. Soc. (8.52)
INC. 280.5 112 3 Places
(11.04) 189
(4.41) Manual Flow (7.44)
249.5 23 Adj. Screw
3 (.12) Hex. Soc. 160 112
(9.82) (.91) Surface of Suction Port
(6.30) (4.41)
225 72 72
Air Vent (8.86) INC. Safety Valve
3 (.12) Hex. Soc. 13 (2.83) (2.83) Pressure Adj. Screw
3 Places 168 Pilot Port "D" Thd. 85.3
(6.61) (.51) 3(.12) Hex. Soc.
3 Secondary Pressure Gauge (3.36)
Cable Departure 89 INC.
Connection for Pump
(For Flow Control) (3.50) Discharge Pressure 11.14 (.4386)
Tank Port 70 "D" Thd. 11.11 (.4374)

(8.19)
"H" Thd. (2.76)

208
50(1.97)
(1.189)

(5.39)

(4.72)
137
30.2

(4.33)

120
(3.27)

110
83

(9.000)
228.6
X

(5.55)
141
Primary Pressure
44.40(1.748) Dia.

152.35(5.998) Dia.
49.39(1.944)
49.21(1.937)

Gauge Connection for


44.45(1.750)

152.40(6.000)

Pump Discharge Pressure 21.5(.85) Dia. Through


"D" Thd. 58.7 24 39(1.54) Dia. Spotface 228.6 R22
"F" Thd. "K" Deep (2.311) (.94) (From Rear) (9.000) (R.87)
4 Places 4 Places 273
26
Discharge Port (1.26) (10.75)
25 (.98) Dia. 264
(10.39)
332
(13.07)
Case Drain Port
2 Filling Port 1
5 (.20) Hex. Soc. [27(1.06) Hex. Head Plug Furnished]

Eye Bolt
M10

Suction Port
48(1.89) Dia.

(3.063)
77.8

"E" Thd. "J" Deep


4 Places
42.9
(1.689)
299.5
1. Use either port of the two pilot and drain ports at your option. Keep (11.79)
the remaining port plugged. Note that on the European Design
Standard (6080 Design), only the left side, as viewed from the shaft
end, of the drain port is machined. View Arrow X
2. Case drain ports are available for use when draining hydraulic fluid
from pump casing.
3. Cable Applicable:
Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" Thd. J mm (IN.) K mm (IN.)
A145-FR04∗S-60 Rc 3/4 Rc 1/4 Rc 3/8
M12 M10 19 (.75) 17 (.67)
A145-FR04∗S-6080 3/4 BSP.F 1/4 BSP. Tr 3/8 BSP. F
A145-FR04∗S-6090 3/4 NPT 1/4 NPT 1/2-13 UNC 7/16-14 UNC 3/8 NPT 21 (.83) 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)

Foot Mounting Type


Mounting bracket is common to that of pressure compensator model.
Refer to page 23 for the dimensions of mounting bracket.

No.46
"A" Series Piston Pumps
Variable Displacement-Single Pumps
Electro-Hydraulic Proportional Pressure & Flow Control Type PISTON A
A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Model Number Designation

Input Signal for


Flow Control
Input Signal for
Pressure Control
Performance
Amplifier Characteristics
Proportional Solenoid

(S ← Input Voltage →L)


Pressure Control
Sensor Valve

Output Flow
1 2

Pressure
Control (S ← Input Voltage → L)
Piston

1. Unloading pressure when input


signal is 0 V.
2. Safety valve setting pressure
Safety valve

Tilt Angle Sensor Bias Piston

Graphic Symbols

A16/A22/A37/A56 A70/A90/A145

Model Number Designation


A70 -F R 04E 16 M A -60 -60 ∗
Direction of Control Control Pressure at Unit of Type of
2 3
Compensation Design Design
Series Number Mounting Control
Rotation Type Input Signal is 5 V Outboard Pump Number Number Std.
Pressure
A16
06 42
(15.8 cm3/rev)
A22
11 42
(22.2 cm3/rev) F:
Flange Viewed 2
A37 from Use the same measure None: kgf/cm
Mtg. 04E: 01 42
(36.9 cm3/rev) Shaft of the control pressure M: MPa
End Proportional as shown on the right,
A56 Pressure & 6.9 MPa P: PSI Refer to
02 42
(56.2 cm3/rev) Flow Control (70 kgf/cm2,1000 PSI) 4
Type specify within the range
A70 Outboard
R: of maximum operating 60 60
(70.0 cm3/rev) L: 1
pressure pump models
Foot Clockwise
A90 Mtg. (Normal) A: A16,A22 60 60
(91.0 cm3/rev) PV2R1
A145 B: A37
PV2R2 60 60
(145.0 cm3/rev)
1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
2. Models A70/A90/A145 can be used as double pumps. Chose either A or B suitable for the outboard pump. For the mounting of outboard pumps,
make inquires separately. If you use these models as single pumps, generally specify "A".
3. Amplifier Compensation Number may differ according to the main machine conditions. Consult Yuken for detail
4. Design Standards: None ........... Japanese Standard "JIS"
80 ............... European Design Standard
90 ............... N. American Design Standard

No.47
"A" Series Piston Pumps
Electro-Hydraulic Proportional Pressure & Flow Control Type PISTON
A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Specifications / Pipe Flange Kit / Instructions
Specifications
Model Numbers A16 A22 A37 A56 A70 A90 A145
Descriptions
Geometric cm3/rev 15.8 22.2 36.9 56.2 70.0 91.0 145.0
Displacement (cu. in./rev) (.964) (1.355) (2.25) (3.43) (4.27) (5.55) (8.85)
2 16 16 16 16 25 25 25
Rated
(2320) (2320) (2320) (2320) (3630) (3630) (3630)
Operating Pres.
MPa (PSI) 1 21 16 21 21 28 28 28
Intermittent
(3050) (2320) (3050) (3050) (4060) (4060) (4060)
Shaft Speed Range r/min 600 - 1800
3 L /min 28.4 40.0 66.4 101.0 126.0 163.0 261.0
Max. Flow
(U.S. GPM) (7.5) (10.6) (17.5) (26.7) (33.3) (43.1) (69.0)

Min. Pres. Required MPa 4


Flow for Flow Adj. 2.0 (290)
(PSI)
Control
Hysteresis Less than 1 %
Repeatability Less than 1 %
Input Signal Max. Flow / 5 V DC
Min. Adjustment MPa
0.7 (100)
Pressure (PSI)
Pressure
Hysteresis Less than 1 %
Control
Repeatability Less than 1 %
Input Signal Specified Control Pressure / 5 V DC
Coil Resistance Ω [@ 20°C (68 °F)] 10
Input Impedance Flow Control : 10kΩ Pres. Control : 10kΩ
Supply Electric Power 24 V DC (21 - 28 V Included Ripple)
Power Input (Max.) W 30
Flow 5 V DC/Max. Flow
Output Signal
Pressure 5 V DC/Specified Control Pressure
Alarm Signal Output (Open Collector) Voltage : Max. 30 V DC Current : Max. 40 mA
Ambient Temperature °C (°F) 0 - 50 (32 - 122) (With Circulated Air)
20.5 20.5 32.0 39.0 64.0 76.5 96.4
Flange Mtg.
(45.2) (45.2) (70.6) (86.0) (141) (169) (213)
Approx. Mass
kg (lbs.)
22.7 22.7 36.3 43.3 76.0 97.0 121.4
Foot Mtg.
(50.1) (50.1) (80.0) (95.5) (168) (214) (268)
1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.
2. When operating the pump exceeding the rated pressure, operating conditions are restricted.
Refer to page 6 for the details.
3. Maximum flow differs to shaft speed.
The value listed above indicates shaft speed of 1800 r/min.
For other shaft speed calculate by the ratio of shaft speed.
4. To secure the required minimum pressure, special sequence valves are available, to be directly installed at the discharge port of the pump. Consult
Yuken for details.

Pipe Flange Kits


For Pipe flange, refer to form of pressure compensator type on page 7.
Instructions
Input Signal
The pump is on unload condition when the pump is operated without input signal voltage.
Electric Source
Always turn off electric source whenever the connector for swash plate tilt angle sensor is removed.
Compensation of Pump Maximum Regulated Flow at Frequency
If the same maximum flow is required at 50 Hz or 60 Hz, connect short plug in the amplifier to 60 Hz at the place where
supplied frequency is 60 Hz. At this condition, maximum flow comes to the same value at 50 Hz.
If short plug is used at 60 Hz without making the change, maximum flow increased in proportion to frequency.
Painting on Amp. Box and Solenoiod
To maintain suitable radiation effect, the amp. Box and the solenoid of the control valve should not be painted.

No.48
"A" Series Piston Pumps
Electro-Hydraulic Proportional Pressure & Flow Control Type PISTON A
A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Typical Pump Characteristics

Output Flow vs. Input Signal


A16 A56
L /min L /min
U.S.GPM 32 U.S.GPM 120
8 30
1800 r/min
100 1800 r/min
25
24 1500 r/min
6 1500 r/min

Output Flow
80
Output Flow

20

4 16 15 60

10 40
2 8
5 20
0 0
0 0
0 1 2 3 4 5 0 1 2 3 4 5
Input Signal V DC Input Signal V DC

A22 A70
U.S.GPM L /min U.S.GPM L /min
12 45 40 150
40 1800 r/min
10 125 1800 r/min
1500 r/min 30
8 30 Output Flow
100 1500 r/min
Output Flow

6 20 75
20
4 50
10 10
2 25
0 0
0 0
0 1 2 3 4 5 0 1 2 3 4 5
Input Signal V DC Input Signal V DC

A90
A37 U.S.GPM L /min
45 175
L /min 1800 r/min
U.S.GPM 80 40 150
20
1500 r/min
1800 r/min 125
Output Flow

16 60 30
1500 r/min 100
Output Flow

12
40 20 75
8
50
20 10
4 25
0 0 0
0
0 1 2 3 4 5 0 1 2 3 4 5
Input Signal V DC Input Signal V DC

Note: Pump characteristics at 1800 r/min is the same as those at 1500 r/min A145
where frequency is compensated. L /min
(Refer to page 48.) U.S.GPM 280
1800 r/min
240
60
1500 r/min
Full Cut-off Pres. vs. Input Signal 50 200
Output Flow

160
PSI MPa A∗-∗R04E27.5M 40
4000 28 120
30
25
80
A∗-∗R04E24.5M 20
Full Cut-off Pressure

3000 20 10 40
A∗-∗R04E20.6M
0
0
15 0 1 2 3 4 5
2000
Input Signal V DC
10
A∗-∗R04E15.7M
1000
5
A∗-∗R04E6.9M
0 0 Refer to page 10 to 16 for performance characteristics of
0 1 2 3 4 5 pressure compensator type excluding characteristics appeared
Input Signal V DC on this catalogue.

No.49
"A" Series Piston Pumps
A16 / A22-∗R04E PISTON
Installation Drawing
PUMPS

Flange Mtg. : A16-FR04E∗-06-42/4280/4290


A22-FR04E∗-11-42/4280/4290

Air Vent
4 3(.12) Hex. Soc.
Cable 3Places
Departure 205.5
(8.09)
232.5 44.5(1.75)
(9.15) Filling Port
1
147.5 [22(.87) Hex. Head Plug Furnished]
(5.81) 151.5 142
26.5 6.5(.26)
(5.96) (5.59)
(1.04) Drain Port "C" Thd.
59
25(.98)
(2.32) 95(3.74) Dia.

(6.38)
162
4.79(.1886)
4.76(.1874)

(3.78)
96
Y X

12(.47)
18(.71)

(3.07)
78
82.50(3.248) Dia.
19.02(.7488) Dia.

82.55(3.250)
19.05(.7500)

21.24(.836)
21.08(.830)

12 R12
(.47) 106
(R.47) (4.17)
172
(6.77) 130
(5.12)

Pres. Sensor 2
Connector

2
3
Tilt Angle
"D" Thd. 17(.67) Deep Sensor Connector
8 Places
47.6(1.874)

47.6(1.874)

Suction Port Discharge Port


19(.75) Dia. 19 (.75) Dia.
22.2 22.2
(.874) (.874) View Arrow X
65
(2.56)

View Arrow Y

1. Install the pump so that the "Filling Port" is at the top. Model Numbers "C" Thd. "D" Thd.
2. Do not touch the screw because it is adjusted at the time of shipment. A16/A22-FR04E∗-∗-42 Rc 3/8
M10
3. For cable connection with amplifiers, see page 56. A16/A22-FR04E∗-∗-4280 3/8 BSP.F
4. Cable Applicable:
A16/A22-FR04E∗-∗-4290 3/8 NPT 3/8-16 UNC
Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.)
Conductor Area ⋅⋅⋅⋅⋅⋅Not Exceeding 1.5mm2(.002 Sq. IN.)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mounting Type
Mounting bracket is common to that of pressure compensator model.
Refer to page 18 for the dimensions of mounting bracket.

No.50
"A" Series Piston Pumps
A37-∗R04E PISTON
PUMPS
A
Installation Drawing

Flange Mtg. : A37-FR04E∗-01-42/4280/4290


Cable Departure 3
Cable Applicable:
Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.)
Conductor Area ⋅⋅⋅⋅⋅⋅
Not Exceeding 1.5mm2(.002 Sq. IN.)

274.5
(10.81)
251.5
(9.90) Filling Port 1
224.5 [22(.87) Hex. Head Plug Furnished]
(8.84)
166.5 Drain Port "C" Thd. 151.5 146.5
(6.56) (5.96) (5.77)
77 62 86 86
Surface of Surface of
(3.03) (2.44) Discharge Port (3.39) (3.39) Suction Port
30 9.5
(1.18) (.37)
40(1.57) 120(4.72) Dia. 2

(6.54)
7.97(.3138)

166
Air Vent 7.94(.3126)

(4.13)
3 (.12) Hex. Soc.
3 Places 105
X
(2.311)
58.7

25(.98)

14(.55)

(3.54)
90
R14
101.55(3.998) Dia.
31.70(1.248) Dia.

Discharge Port (R.55)


101.60(4.000)
35.32(1.391)
35.14(1.383)
31.75(1.250)

32 (1.26) Dia.
30.2 12 146
"D" Thd. "E" Deep (1.189) (.47) (5.75)
4 Places 178.5 174
(7.03) (6.85)
252.5
(9.94)
Tilt Angle 3 Pres. Sensor 3
Sensor Connector Connector

1. Install the pump so that the "Filling Port" is at the top. Suction Port
32(1.26) Dia.
2. Do not touch the screw because it is adjusted at the time of shipment.
3. For cable connection with amplifiers, see page 56.
(2.311)
58.7

Model Numbers "C" Thd. "D" Thd. E mm (IN.)


A37-FR04E∗-01-42 Rc 1/2
M10 19 (.75)
A37-FR04E∗-01-4280 1/2 BSP.F
"D" Thd. "E" Deep
A37-FR04E∗-01-4290 1/2 NPT 7/16-14 UNC 20 (.79) 30.2 4 Places
(1.189)
178.5
(7.03)

View Arrow X

DIMENSIONS IN
MILLIMETRES (INCHES)

Foot Mounting Type


Mounting bracket is common to that of pressure compensator model.
Refer to page 19 for the dimensions of mounting bracket.

No.51
"A" Series Piston Pumps
A56-∗R04E PISTON
Installation Drawing
PUMPS
Flange Mtg. : A56-FR04E∗-02-42/4280/4290
4
Cable Departure
Cable Applicable:
Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.) Filling Port 1
Conductor Area ⋅⋅⋅⋅⋅⋅ [22(.87) Hex. Head Plug Furnished]
Not Exceeding 1.5mm2(.002 Sq. IN.)
287
(11.30) 2
264 Drain Port "C" Thd.
(10.39) (Both Sides)
151.5 160.5
237 (5.96) (6.32)
(9.33) 100 100
Surface of Surface of
179 62 (3.94) (3.94)
Discharge Port Suction Port
(7.05) (2.44) 41 49
Surface of Drain Port Surface of Drain Port
50.5 9.5 (1.61) (1.93)
(1.99) (.37)
43.5
(1.71)
40 3

(1.57)

(7.52)
191
Air Vent 7.97(.3128)
3 (.12) Hex. Soc. 7.94(.3126)
3 Places R14

(3.54)
(R.55)

90
X
(2.311)
58.7

25(.98)

14(.55)

(3.86)
98
31.70(1.248) Dia.

101.55(3.998) Dia.

120(4.72) Dia.
31.75(1.250)

101.60(4.000)
35.32(1.391)
35.14(1.383)

Discharge Port
32 (1.26) Dia.
30.2 12 146
"D" Thd. (1.189) (.47) (5.75)
"E" Deep 191 174
4 Places (7.52) (6.85)
265
(10.43)

4 4
Tilt Angle Pres. Sensor
Sensor Connector Connector

Suction Port
35(1.38) Dia.
(2.311)
58.7

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports at your option. Keep the remaining port
plugged. Note that on the European design standard (4280 Design), only the left
side, as viewed from the shaft end, of the drain port is machined. "D" Thd. "E" Deep
30.2 4 Places
3. Do not touch the screw because it is adjusted at the time of shipment.
(1.189)
4. For cable connection with amplifiers, see page 56. 191
(7.52)
Model Numbers "C" Thd. "D" Thd. E mm (IN.)
A56-FR04E∗-02-42 Rc 3/4 View Arrow X
M10 19 (.75)
A56-FR04E∗-02-4280 3/4 BSP.F
A56-FR04E∗-02-4290 3/4 NPT 7/16-14 UNC 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mounting Type
Mounting bracket is common to that of pressure compensator model.
Refer to page 20 for the dimensions of mounting bracket.

No.52
"A" Series Piston Pumps
A70-∗R04E PISTON
PUMPS
A
Installation Drawing
Flange Mtg. : A70-FR04E∗∗-60-60/6080/6090
4
Cable Departure
Cable Applicable:
Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.)
Conductor Area ⋅⋅⋅⋅⋅⋅Not Exceeding 1.5mm2(.002 Sq. IN.)
333.5
(13.13)
307 2
(12.09) Drain Port "C" Thd. 116.5 155
249 (Both Sides) (4.59) (6.10)
(9.80) 62 95 95
Surface of Discharge Port Surface of Suction Port
(2.44) (3.74) (3.74)
65 19.5(.77) Surface of Drain Port 73 73
Surface of Drain Port
(2.56) (2.87) (2.87)
9.5(.37)

40(1.57)
7.97(.3138)

(8.17)
207.5
7.94(.3126)
Air Vent
3 (.12) Hex. Soc.

(3.54)
3 Places
52.4(2.063)

90

18(.71)

(7.09)
180
Y

(4.65)
118
31.70(1.248) Dia.

126.95(4.998) Dia.

Discharge Port 35(1.38) Dia. Spotface


26 (1.02) Dia. 2 Places
31.75(1.250)

127.00(.5000)
35.32(1.391)
35.14(1.383)

16 (From Rear)
"E" Thd. 26.2 (.63) 181
17(.67) Deep
(1.031) 18 (7.13)
4 Places
(.71) 211
246.5 (8.31)
(9.70)
305.5
(12.03)
5
Filling Port 1
[22(.87) Hex. Head Plug Furnished] 4
Tilt Angle
Eye Bolt Sensor Connector
M10 Pres. Sensor 4

Connector

3 3
Suction Port
38(1.38) Dia.

(2.752)
69.9

View Arrow Y
"D" Thd. "F" Deep
35.7 4 Places
(1.406)
246.5
(9.70)
Case Drain Port
5 (.20) Hex. Soc.

View Arrow X

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports at your option. Keep the remaining port plugged. Note that on the European design standard (6080 Design), only
the left side, as viewed from the shaft end, of the drain port is machined.
3. Do not touch the screw because it is adjusted at the time of shipment.
4. For cable connection with amplifiers, see page 56.
5. If you do not use the special sequence valve, plug the port (FP-SC-1/32)

Dimensions mm (IN.)
Model Numbers "C" Thd. "D" Thd. "E" Thd.
F
A70-FR04E∗∗-60-60 Rc 3/4
M12 M10 19 (.75)
A70-FR04E∗∗-60-6080 3/4 BSP.F
A70-FR04E∗∗-60-6090 3/4 NPT 1/2-13 UNC 3/8-16 UNC 21 (.83)

DIMENSIONS IN
Foot Mounting Type
MILLIMETRES (INCHES)
Mounting bracket is common to that of pressure compensator model.
Refer to page 21 for the dimensions of mounting bracket.

No.53
"A" Series Piston Pumps
A90-∗R04E PISTON
Installation Drawing
PUMPS

Flange Mtg. : A90-FR04E∗∗-60-60/6080/6090


4
Cable Departure
Cable Applicable:
Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.)
Conductor Area ⋅⋅⋅⋅⋅⋅Not Exceeding 1.5mm2(.002 Sq. IN.)
347
(13.66) 2 117.5 155
320 Drain Port "C" Thd.
(4.63) (6.10)
(12.60) (Both Sides) Surface of Discharge Port Surface of Suction Port
262 95 105 105
(10.31) (3.74) (4.13) (4.13)
119.5 23(.91) 68 68
Surface of Drain Port Surface of Drain Port
(4.70) Filling Port 1 (2.68) (2.68)
13(.51) [27(1.06) Hex. Head Plug Furnished]

63(2.48)
Air Vent

(8.54)
217
3 (.12) Hex. Soc. 9.56(.3764)
3 Places 3
9.53(.3752)

(4.45)
113
3 X

(6.362)
(2.311)

161.6
58.7

(5.00)
127
152.35(5.998) Dia.
38.05(1.498) Dia.

Discharge Port
32 (1.26) Dia.
152.40(6.000)
42.36(1.668)
42.18(1.661)
38.1(1.500)

22 21.5(.85) Dia. Through R22


30.2 39(1.54) Dia. Spotface 161.6 (R.87)
"E" Thd. "H" Deep (.87)
(1.189) (From Rear) (6.362)
4 Places 23
(.91) 4 Places
270
(10.63)
324
(12.76)
5
Case Drain Port 4
Tilt Angle
5 (.20) Hex. Soc. Sensor Connector
Eye Bolt 4
M10 Pres. Sensor
Connector

Suction Port
48(1.89) Dia.

(3.063)
77.8

"D" Thd. "F" Deep


4 Places
42.9
(1.689)
270
(10.63)

View Arrow X

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports at your option. Keep the remaining ports plugged. Note that on the European design standard (6080 Design),
only the left side, as viewed from the shaft end, of the drain port is machined.
3. Do not touch the screw because it is adjusted at the time of shipment.
4. For cable connection with amplifiers, see page 56.
5. If you do not use the special sequence valve, plug the port (FP-SC-1/32)

Dimensions mm (IN.)
Model Numbers "C" Thd. "D" Thd. "E" Thd.
F H
A90-FR04E∗∗-60-60 Rc 3/4
M12 M10 19 (.75) 19 (.75)
A90-FR04E∗∗-60-6080 3/4 BSP.F
A90-FR04E∗∗-60-6090 3/4 NPT 1/2-13 UNC 7/16-14 UNC 21 (.83) 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mounting Type
Mounting bracket is common to that of pressure compensator model.
Refer to page 22 for the dimensions of mounting bracket.

No.54
"A" Series Piston Pumps
A145-∗R04E PISTON
PUMPS
A
Installation Drawing

Flange Mtg. : A145-FR04E∗∗-60-60/6080/6090


4
Cable Departure
Cable Applicable:
Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.)
Conductor Area ⋅⋅⋅⋅⋅⋅Not Exceeding 1.5mm2(.002 Sq. IN.)
358.5
(14.11) Drain Port 2
331.5 "C" Thd.
(13.05) (Both Sides) 169.5
273.5 112 (6.67)
(10.77) (4.41) 112 112
Surface of Discharge Port Surface of Suction Port
89 23 (4.41) (4.41)
(3.50) (.91) Surface of Drain Port 72 72
Surface of Drain Port
59 13 (2.83) (2.83)
Filling Port 1 11.14(.4386)
(2.32) (.51)
[27(1.06) Hex. Head Plug Furnished] 11.11(.4374)
70
Air Vent (2.76)

(8.62)
219
3 (.12) Hex. Soc. X

(4.33)
3 Places 5
110

(9.000)
(2.311)

228.6
58.7

(5.55)
141
Discharge Port
152.35(5.9980) Dia.
44.40(1.7480) Dia.

32 (1.26) Dia.
152.40(6.0000)
44.45(1.7500)

49.39(1.944)
49.21(1.937)

"E" Thd. 21.5(.85) Dia. Through


"H" Deep 30.2 24 39(1.54) Dia. Spotface 228.6 R22
4 Places (1.189) (.94) 4 Places (9.000) (R.87)
26 (From Rear) 273
(1.02) (10.75)
299.5
(11.79)
357.5 4
(14.07) Tilt Angle
Case Drain Sensor Connector
Port 4
Eye Bolt Pres. Sensor
5 (.20) Hex. Soc. M10 Connector
3

A145-FR04E A ; 379.5(14.94) 3

A145-FR04E B ; 383(15.08)

(3.063)
77.8

Suction Port
48(1.89) Dia.
"D" Thd. "F" Deep
42.9 4 Places
(1.689)
299.5
(11.79)

View Arrow X
1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of two drain ports at your option. Keep the remaining port plugged. Note that on the European design standard (6080 Design), only
the left side, as viewed from the shaft end, of the drain port is machined.
3. Do not touch the screw because it is adjusted at the time of shipment.
4. For cable connection with amplifiers, see page 56.
5. If you do not use the special sequence valve, plug the port (FP-SC-1/32)

Dimensions mm (IN.)
Model Numbers "C" Thd. "D" Thd. "E" Thd.
F H
A145-FR04E∗∗-60-60 Rc 3/4
M12 M10 19 (.75) 19 (.75)
A145-FR04E∗∗-60-6080 3/4 BSP.F
A145-FR04E∗∗-60-6090 3/4 NPT 1/2-13 UNC 7/16-14 UNC 21 (.83) 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mounting Type
Mounting bracket is common to that of pressure compensator model.
Refer to page 23 for the dimensions of mounting bracket.

No.55
"A" Series Piston Pumps
A16 / A22 / A37 / A56 / A70 / A90 / A145-FR04E PISTON
Cable connection between pump and amplifier
PUMPS
Cable connection between pump and amplifier
The cable connections between the proportional pilot valve and the sensor of the pump and the attached amplifier
(SK1106) are shown below.

Proportional
Pilot Valve
"A" Series
Piston Pump
Tilt Angle
Sensor

Pressure
Sensor

1
Cable Ass'y
1 : For Solenoid
Colour of Lead Wire 2 : For Power Supply
1 3 : For Pressure Sensor
Red......Power Supply, +24V DC 4 3
White...Power Supply, 0V 4 : For Tilt Angle Sensor
Shield...Ground 5 : For Signal

Colour of Lead Wire


Red........Input Signal, Flow
2
Black.....Input Signal, Common
White....Input Signal, Pressure
Yellow...Sensor Monitor, Pressure 5
Green.....Sensor Monitor, Flow

06P 05P 04P 03P 02P

1 2 3 4 5 6 1 2 3 4 5 1 2 3 4 1 2 3 1 2
2
Amplifier
Sensor
Pres.

FUSE

Supply
Power

Solenoid
Signal

Sensor
Tilt Angle

(5A)

Model : SK1106-∗-∗-∗-11
CN5

CN4

CN3

CN2

CN1

POWER

1. Cable assemblies are available. When ordering, specify the cable ass'y model numbers from the table below.

Cable Ass'y Model Numbers


Name of Cable Ass'y Approx. Length of Cable mm(ft.)
2000 (6.6) 5000 (16.4) 10000 (32.8)
1 For Solenoid SK1112-S-2-10 SK1112-S-5-10 SK1112-S-10-10
2 For Power Supply SK1112-V-2-10 SK1112-V-5-10 SK1112-V-10-10
3 For Pressure Sensor SK1112-P-2-10 SK1112-P-5-10 SK1112-P-10-10
4 For Tilt Angle Sensor SK1112-Q-2-10 SK1112-Q-5-10 SK1112-Q-10-10
5 For Signal SK1112-C-2-10 SK1112-C-5-10 SK1112-C-10-10

2. For the details of amplifier, see the follwing page.

No.56
Amplifiers for Electro-Hydraulic Proportional
Pressure & Flow Control Type Pumps PISTON
PUMPS
A
Specifications / Installation Drawing

Specifications
Model No. List of Amplifier Model No.
SK1106-∗-∗-∗-10
Description Pump Model Numbers Amplifier Model Numbers
Applicable Coil Resistance 10 Ω A16-∗R04E -06-42∗ SK1106- -16-06-10
Input Impedance 10 kΩ
A22-∗R04E -11-42∗ SK1106- -22-11-10
Power Supply 24 V DC (21 - 28 V Included Ripple)
A37-∗R04E -01-42∗ SK1106- -37-01-10
Power Input (Max.) 30 W
A56-∗R04E -02-42∗ SK1106- -56-02-10
Input Signal Max. Flow/5V, Specified Pres./5V
Output Signal for Sensor Monitor 5V/Max. Flow, 5V/Specifed Pres. A70-∗R04E ∗-60-60∗ SK1106- -70-60-10

Ambient Temperature 0 - 50 °C (32 - 122 °F) A90-∗R04E ∗-60-60∗ SK1106- -91-60-10


Approx. Mass 450 g (1.0 lbs.) A145-∗R04E ∗-60-60∗ SK1106- -145-60-10

Note: Fill control pressure (at input signal is 5 V) in section


marked .

50/60 Hz Short Plug


(Including in the Amplifier)

15
CN1 POWER
Solenoid
1 2

/ SOLENOID 04E PUMP


CN1
CN2 CONTROLLER
1 2 3

Power Supply / POWER SUPPLY


CN2

Fuse
FUSE
FUSE

(5A)

(6.50)
(5.51)
165
140
1 2 3 4 5 1 2 3 4

CN3 / PRESSURE SENSOR


Pres. Sensor CN3

/ TILT ANGLE SENSOR


CN4 CN4
Tilt Angle Sensor
MODEL
SK1106-∗∗∗-∗∗∗-∗∗-10
1 2 3 4 5 6

AMP. MFG NO.


/ I/O SIGNAL
PUMP MFG NO.

CN5
CN5 YUKEN KOGYO CO. LTD.
MADE IN JAPAN
(.20)

Input/Output
5

Signal

92
(3.62)
100
Connector Name of Signal (3.94)
CN1 1
Output to pilot valve solenoid
Solenoid 2
CN2 1 0 [V] (0V )
Power 2 +24 [V] (24V)
Supply 3 0 [V]
1 +5 [V]
CN3 Power Supply for Sensor
2 0 [V]
Pres.
(1.89)

3 Input Signal - Sensor


48

Sensor
4 0 [V]
1 +8 [V]
Power Supply for Sensor N-SK 1106-10 ∗∗∗∗∗-95
CN4 2 0 [V]
Tilt
3 Input Signal - Sensor
Angle
Sensor 4 0 [V]
5
1 Input Signal - Flow (Qin)
2 Input Signal - Common (COM)
CN5 DIMENSIONS IN
Input/ 3 Input Signal - Pres. (Pin) MILLIMETRES (INCHES)
Output 4 Output Signal - Sensor Monitor P (SMP)
Signal
5 Output Signal - Sensor Monitor Q(SMQ)
6 0 [V]

No.57
"A" Series Piston Pumps
Variable Displacement-Single Pumps
Pilot Pressure Control Type Pressure Compensator
PISTON
A10 / A16 / A22 / A37 / A56 / A70 / A90 / A145 PUMPS
Specifications

Graphic Symbol Performance Characteristics

Output Flow
M
O

Pressure

Specifications
Geometric Minimum Operating Pres. Shaft Speed Range Approx. Mass
MPa (PSI) Minimum r/min kg (lbs.)
Displacement Adj. Flow
Model Numbers Adj. Pres.
cm3/rev cm3/rev 2 1 Flange Foot
(cu. in. /rev) (cu. in. /rev) Rated Intermittent MPa (PSI) Max. Min.
Mtg. Mtg.
A10-FR07-12∗ 10.0 (.610) 2 (.122) 16 (2320) 21 (3050) 2.0 (290) 1800 600 8.5 (18.7) 10.7 (23.6)
A16-∗-R-07-∗-K-32∗ 15.8 (.964) 4 (.244) 16 (2320) 21 (3050) 1.2 (175) 1800 600 21 (46.3) 23.2 (51.2)
A22-∗-R-07-∗-K-32∗ 22.2 (1.355) 6 (.366) 16 (2320) 16 (2320) 1.2 (175) 1800 600 21 (46.3) 23.2 (51.2)
A37-∗-R-07-∗-K-32∗ 36.9 (2.25) 10 (.610) 16 (2320) 21 (3050) 1.2 (175) 1800 600 29 (63.9) 33.3 (73.4)
A56-∗-R-07-∗-K-32∗ 56.2 (3.43) 12 (.732) 16 (2320) 21 (3050) 1.2 (175) 1800 600 36 (79.4) 40.3 (88.9)
A70-∗R07S-60∗ 70.0 (4.27) 30 (1.83) 25 (3630) 25 (3630) 2 (290) 1800 600 60.3 (133) 72.3 (159)
A90-∗R07S-60∗ 91.0 (5.55) 56 (3.42) 25 (3630) 25 (3630) 2 (290) 1800 600 77.5 (171) 98 (216)
A145-∗R07S-60∗ 145 (8.85) 83 (5.06) 25 (3630) 25 (3630) 2 (290) 1800 600 94 (207) 119 (262)

1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.
2. When operating the pump exceeding the rated pressure, operating conditions are restricted.
Refer to page 6 for the details.

No.58
"A" Series Piston Pumps
Pilot Pressure Control Type Pressure Compensator
A10 / A16 / A22 / A37 / A56 / A70 / A90 / A145
PISTON
PUMPS
A
Model Number Designation

Model Number Designation


A16 -F -R -07 -S -K -32 ∗
Direction of Control Port Shaft Design
Series Number Mounting Design Std.
Rotation Type Position Extension Number

A16 Viewed from 32


(15.8 cm3/rev) Shaft End
F: None: 2
A22 Flange Mtg. Axial Port
07: 32
(22.2 cm3/rev) R: Pilot Pressure
Clockwise
1
Control Type K: Refer to 4

A37 Keyed Shaft


L: (Normal) Pressure S:
32
(36.9 cm3/rev) Foot Mtg. Compensator Side Port

A56
32
(56.2 cm3/rev)

A70 -F R 07 S -60 ∗
Direction of Design Design
Series Number Mounting Control Type Port Position
Rotation Number Std.
A10 F: 3 Viewed from 12
(10.0 cm3/rev) Flange Mtg.
Shaft End
A70 07:
60
(70 cm3/rev) F: Pilot Pressure 4
R: Control Type Refer to
A90 Flange Mtg. 1 S:
Clockwise Pressure 60
(91.0 cm3/rev) L: Compensator Side Port
(Normal)
A145 Foot Mtg.
60
(145 cm3/rev)

1. Available to supply pump with anti-clockwise rotation. Consult 2. The axial port is not available to the N.American Design Standard of
Yuken for details. A37 and A56.
3. When A10 pump is used as the foot Mtg., order the Mtg. Bracket kit 4. Design Standards: None ........... Japanese Standard "JIS"
shown below separately. Refer to page 17 for dimensions of the Mtg. 80 ............... European Design Standard
bracket. 90 ............... N. American Design Standard

Mtg. Bracket Approx. Mass


Kit Numbers kg (lbs.)
LP-1A-10 2.2 (4.9)
Note: The mounting bracket kit consists of a mounting bracket, 2 hex. bolts
and 2 plain washer.

Performance Characteristics
For performance characteristics, refer to models of pressure compensator type on page 10 to 16.
Pipe Flange Kit
For pipe flange, refer to form of pressure compensator type on page 7.

No.59
"A" Series Piston Pumps
A10-FR07 PISTON
Installation Drawing
PUMPS

Flange Mtg. : A10-FR07-12/1280/1290

Filling Port 1
[22(.87) Hex. Head Plug Furnished]
3
Drain Port "E" Thd.
Pilot Port "PP"
"D" Thd. Fully Extended
Fully Extended 180(7.09)
96.5(3.80) 170 44.5(1.75)
Safety Valve
Pressure Adj. Screw (6.69)
3(.12) Hex. Soc. 33(1.30) 90.5 6.5(.26)
(3.56)
INC. 52.5 25 4.79(.1886)
Flow Adj. Screw (2.07) (.98)
4.76(.1874)
(4.21)

13(.51) Hex.
107
(3.62)

(2.56)
92

(1.61)
(6.73)

65
171

41

DEC.

(.43)
11
82.50(3.248) Dia.
19.02(.7488) Dia.
2 3 10.5

19.05(.7500)

82.55(3.250)
21.24(.836)
21.08(.830)
Suction Port 25 25 106
(.41) 93 (3.66)
"C" Thd. (4.17)
(.98) (.98) 131 Dia.
64.5 64.5 (5.16) 130
(2.54) (2.54) 156 (5.12)
2 3
Discharge Port (6.14)
"C" Thd. 159.5
(6.28)

1. Install the pump so that the "Filling Port" is at the top. 3. As the tightening torques of suction, discharge and drain port fittings,
2. Use either port of two suction and outlet ports at your option. Keep the conform to the below.
remaining ports plugged.
Port Tightening Torque
Suction Port 65 - 75 Nm
Model Numbers "C" Thd. "D" Thd. "E" Thd. Discharge Port (575 - 664 IN. lbs)
A10-FR07-12 Rc 1/2 Rc 1/4 Rc 3/8
40 - 50 Nm
A10-FR07-1280 1/2 BSP.F 1/4 BSP.Tr 3/8 BSP.F Drain Port
(354 - 443 IN. lbs)
A10-FR07-1290 1/2 NPT 1/4 NPT 3/8 NPT

DIMENSIONS IN
MILLIMETRES (INCHES)

Foot Mounting Type


Mounting bracket is common to that of pressure compensator model.
Refer to page 17 for the dimensions of mounting bracket.

No.60
"A" Series Piston Pumps
A16 / A22-F-R-07 PISTON
PUMPS
A
Installation Drawing

Axial Port Type

Flange Mtg. : A16-F-R-07-K-32/3280/3290


A22-F-R-07-K-32/3280/3290
Fully Extended
227(8.94)
202
2
(7.95)
Pilot Port "PP"
"D" Thd. 187 44.5
(7.36) (1.75)
59 6.5
1
(2.32) (.26) Filling Port
26.5 [22(.87) Hex. Head Plug Furnished]
(1.04) Drain Port "C" Thd.
4.79(.1886)
25(.98)
4.76(.1874)
(4.29)

(3.78)
109

(3.25)

96
82.5

(2.44)
62
(7.36)
187

(.71)
(.47)

18
12
X
82.50(3.248) Dia.
19.02(.7488) Dia.

R12
19.05(.7500)

82.55(3.250)

(R.47)
21.24(.836)
21.08(.830)

95(3.74) Dia.
12 106
(.47) (4.17)
172 130
(6.77) (5.12)
188
(7.40)

Flow Adj. Screw


43.5
5(.20) Hex. Soc.
(1.71)
16 18 2
DEC. (.63) Pilot Port "PP"
(.71)
Safety Valve Pressure Adj. "E" Thd.
Screw 17(.67) Hex. Soc.

INC.
(2.56)

1. Install the pump so that the "Filling Port" is at the top.


65

2. Use either port of two pilot ports at your option. Keep the remaining
(1.874)
47.6

port plugged.

22.2
Suction Port (.874) "F" Thd. 17(.67) Deep
19(.75) Dia. 65 8 Places
(2.56) Discharge Port
19(.75) Dia.
View Arrow X

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd.
A16/A22-F-R-07-K-32 Rc 3/8 Rc 3/8 Rc 1/4
M10
A16/A22-F-R-07-K-3280 3/8 BSP. F 3/8 BSP. F 1/4 BSP. Tr
A16/A22-F-R-07-K-3290 3/8 NPT 3/8 NPT 1/4 NPT 3/8-16 UNC

DIMENSIONS IN
MILLIMETRES (INCHES)

Side Port Type Foot Mounting Type


Port mounting dimensions are the same as those of pressure Mounting bracket is common to that of pressure
compensator model. Refer to page 18 for port mounting compensator model. Refer to page 18 for the dimensions
dimensions. of mounting bracket.

No.61
"A" Series Piston Pumps
A37-F-R-07 PISTON
Installation Drawing
PUMPS
Side Port Type

Flange Mtg. : A37-F-R-07-S-K-32/3280/3290


Fully Extended
250
(9.84)
225
(8.86)
210 59
(8.27) (2.32)
2
Pilot Port "PP" 77 9.5 1
(3.03) (.37) Filling Port
"D" Thd.
30 [22(.87) Hex. Head Plug Furnished]
(1.18) Drain Port "C" Thd.

6.38(.2512)
32(1.26) 6.35(.2500)
(4.41)

(4.13)
(3.48)
112

105
88.5

(2.68)
68
(7.95)

(2.311)
202

X
58.2

(.55)

(.98)
14

25
101.55(3.998) Dia.
22.20(.8740) Dia.

R14
101.60(4.000) 120(4.72) Dia. (R.55)
22.23(.8752)

"F" Thd. "H" Deep


25.01(.985)
24.85(.978)

4 Places (Both Sides) 30.2 12 146


(1.189) (.47) (5.75)
Discharge Port 32(1.26) Dia. 178.5 174
(Rear Side) (7.03) (6.85)
Suction Port 32(1.26) Dia. 202
(7.95)
Flow Adj. Screw
5(.20) Hex. Soc 46.5 2
Pilot Port "PP"
(1.83) "E" Thd.
DEC. 13 21
Safety Valve Pressure (.51) (.83)
Screw 17(.67) Hex. Soc
1. Install the pump so that the "Filling Port" is at the top.
INC.
2. Use either port of two pilot ports at your option. Keep the remaining
(2.80)

port plugged.
71

86 86
(3.39) (3.39)
Surface of Surface of
Suction Port Discharge Port

View Arrow X

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" mm (IN.)
A37-F-R-07-S-K-32 Rc 1/2 Rc 3/8 Rc 1/4
M10 19 (.75)
A37-F-R-07-S-K-3280 1/2 BSP.F 3/8 BSP.F 1/4 BSP. Tr
A37-F-R-07-S-K-3290 1/2 NPT 3/8 NPT 1/4 NPT 7/16-14 UNC 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)

Axial Port Type Foot Mounting Type


Port mounting dimensions are the same as those of pressure Mounting bracket is common to that of pressure
compensator model. Refer to page 19 for port mounting compensator model. Refer to page 19 for the dimensions
dimensions. of mounting bracket.

Note: "Axial Port Type" is not available for N. American Design


Standard.

No.62
"A" Series Piston Pumps
A56-F-R-07 PISTON
PUMPS
A
Installation Drawing

Side Port Type

Flange Mtg. : A56-F-R-07-S-K-32/3280/3290


Fully Extended
262.5(10.33)
237.5
2 (9.35)
Pilot Port "PP" 222.5 62
"D" Thd. (8.76) (2.44) Filling Port 1
50.5 9.5 [22(.87) Hex. Head Plug Furnished]
(1.99) (.37)
43.5 Drain Port 2
(1.71) "C" Thd. Surface of Drain Port
41 49
(1.61) (1.93)

7.97(.3138)
40(1.57)
7.94(.3126)
(5.43)
138

(3.84)

(3.54)
97.5

(3.03)
90

77
(9.29)
236

X
(2.311)

(.55)
58.7

(.98)
14

25
101.55(3.998) Dia.
31.70(1.248) Dia.

R14
(R.55)
101.60(4.000)
31.75(1.250)

35.32(1.391)
35.14(1.383)

"F" Thd. "H" Deep 30.2 12 120(4.72) 146


4 Places (Both Sides) (1.189) (.47) Dia. (5.75)
Discharge Port 30(1.18) Dia. 191 174
(Rear Side) (7.52) (6.85)
Suction Port 35(1.38) Dia. 232
(9.13)
Flow Adj. Screw
5(.20) Hex. Soc. 46.5
(1.83) 2
Pilot Port "PP"
DEC. "E" Thd.
13 21
(.51) (.83)
1. Install the pump so that the "Filling Port" is at the top.
Safety Valve Pressure Adj.
Screw 5(.20) Hex. Soc. 2. Use either port of two pilot and drain ports at your option. Keep the
remaining ports plugged. Note that on the European Design Stand-
INC. ard (3280 Design), only the left side, as viewed from the shaft
(3.15)

end, of the drain port is machined.


80

100 100
(3.94) (3.94)
Surface of Suction Port Surface of Discharge Port

View Arrow X

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" mm (IN.)
A56-F-R-07-S-K-32 Rc 3/4 Rc 3/8 Rc 1/4
M10 19 (.75)
A56-F-R-07-S-K-3280 3/4 BSP.F 3/8 BSP.F 1/4 BSP. Tr
A56-F-R-07-S-K-3290 3/4 NPT 3/8 NPT 1/4 NPT 7/16-14 UNC 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)

Axial Port Type Foot Mounting Type


Port mounting dimensions are the same as those of pressure Mounting bracket is common to that of pressure
compensator model. Refer to page 20 for port mounting compensator model. Refer to page 20 for the dimensions
dimensions. of mounting bracket.
Note: "Axial Port Type" is not available for N. American Design
Standard.

No.63
"A" Series Piston Pumps
A70-FR07S PISTON
Installation Drawing
PUMPS
Flange Mtg. : A70-FR07S-60/6080/6090

2
Drain Port 95 95
Surface of Surface of
"C" Thd. Discharge Port (3.74) (3.74) Suction Port
Fully Extended 62 (Both Sides) 73 73
351.5(13.84) (2.44) Surface of Surface of
Drain Port (2.87) (2.87) Drain Port
65 13
(2.56) 27(1.06) Dia. Spotface
4 Places (.51)
9.5
(From Rear)
(.37)
40 7.97(.3138)

14(.55)
(1.57) 7.94(.3126)

(7.11)

(7.17)
180.5

182
X Y

(3.54)

(.71)
90

18

(4.508)
(2.063)

(7.09)
114.4
52.4

180

(4.65)
118
126.95(4.998) Dia.
Discharge Port
31.70(1.248) Dia.

35(1.38) Dia. Spotface


26(1.02) Dia.
(From Rear)
127.00(5.000)
31.75(1.250)

35.32(1.391)
35.14(1.383)

"E" Thd. 19.5 2 Places


17(.67) Deep 26.2 (.77) 114.4
4 Places (1.031) 16 (4.508)
(.63) 134
18 (5.28)
(.71) 181
246.5 (7.126)
(9.70) 211
(8.31)

Surface of
Pilot Port "PP1"
2
Pilot Port "PP2"
316.5 "F" Thd.
(14.46)
244
Eye Bolt (9.61)
M10
1
22(.87) Filling Port
2 [22(.87) Hex. Head Plug Furnished]
Pilot Port "PP1" Safety Valve Pres.
"F" Thd. Adj. Screw

(6.52)
165.5
14(.55) Hex.
INC.

(2.752)
69.9

Flow Adj. Screw


17(.67) Hex. Suction Port
DEC. 38(1.50) Dia.
View Arrow X 3 "D" Thd. "H" Deep
Case Drain Port
35.7
5(.20) Hex. Soc.
(1.406)
1. Install the pump so that the "Filling Port" is at the top. 246.5
2. Use either port of two pilot and drain ports at your option. Keep the (9.70)
remaining ports plugged. Note that on the European Design
Standard (6080 Design), only the left side, as viewed from the shaft View Arrow Y
end, of the drain port is machined.
3. Case drain port is available for use when draining hydraulic fluid
from pump casing.

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" mm (IN.)
A70-FR07S-60 Rc 3/4 Rc 1/4
M12 M10 19 (.75)
A70-FR07S-6080 3/4 BSP.F 1/4 BSP. Tr
A70-FR07S-6090 3/4 NPT 1/2-13 UNC 3/8-16 UNC 1/4 NPT 21 (.83)

DIMENSIONS IN
MILLIMETRES (INCHES)

Foot Mounting Type


Mounting bracket is common to that of pressure compensator model.
Refer to page 21 for the dimensions of mounting bracket.

No.64
"A" Series Piston Pumps
A90-FR07S PISTON
PUMPS
A
Installation Drawing

Flange Mtg. : A90-FR07S-60/6080/6090

2
Drain Port
"C" Thd.
(Both Sides) Surface of Surface of
95 Discharge Port Suction Port
(3.74) 105 105
119.5 23(.91) (4.13) (4.13)
(4.70) 68 68
13(.51) Surface of Surface of
Drain Port (2.68) (2.68) Drain Port
63(2.48)

(7.48)

(7.50)
190.5
190
X 9.56(.3764) Y

(4.45)
113
9.53(.3752)

(6.362)
(2.311)

161.6
58.7

(5.00)
127
Discharge Port
152.35(5.998) Dia.
38.05(1.498) Dia.

32(1.26) Dia.
152.40(6.000)
38.10(1.500)

22 21.5(.85) Dia. Through


42.36(1.668)
42.18(1.661)

30.2 161.6 R22(R.87)


"E" Thd. (.87) 39(1.54) Dia. Spotface
"J" Deep (1.189) 23 (From Rear) (6.362)
4 Places (.91) 4Places
270
(10.63) Surface of Pilot Port "PP1"
3
Case Drain Port 2
5(.20) Hex. Soc. Fully Extended Pilot Port "PP2"
376(14.80) "F" Thd.
341 Safety Valve Pres. Adj. Screw
(13.43) 14(.55) Hex.
Eye Bolt
268.5 INC.
1 M10
2 Filling Port (10.57)
Pilot Port "PP1" Flow Adj. Screw
[27(1.06) Hex. Head Plug Furnished] 17(.67) Hex.
"F" Thd.
DEC.
9.5 17.5

(6.69)
170
(.37) (.69) (3.46)
88
(3.063)
77.8

Suction Port
48(1.89) Dia.

42.9
View Arrow X (1.689)
270
"D" Thd. "H" Deep
(10.63)
4 Places

View Arrow Y

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two pilot and drain ports at your option. Keep the
remaining ports plugged. Note that on the European Design Standard
(6080 Design), only the left side, as viewed from the shaft end, of
the drain port is machined.
3. Case drain port is available for use when draining hydraulic fluid
from pump casing.

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. H mm (IN.) J mm (IN.)
A90-FR07S-60 Rc 3/4 Rc 1/4
M12 M10 19 (.75) 19 (.75)
A90-FR07S-6080 3/4 BSP.F 1/4 BSP. Tr
A90-FR07S-6090 3/4 NPT 1/2-13 UNC 7/16-14 UNC 1/4 NPT 21 (.83) 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mounting Type
Mounting bracket is common to that of pressure compensator model.
Refer to page 22 for the dimensions of mounting bracket.

No.65
"A" Series Piston Pumps
A145-FR07S PISTON
Installation Drawing
PUMPS
Flange Mtg. : A145-FR07S-60/6080/6090

Drain Port 2
"C" Thd.
(Both Sides) Surface of Surface of
Discharge Port Suction Port
112 112
Fully Extended 112 (4.41) (4.41)
400.5(15.77) (4.41) 72 72
89 23 Surface of Surface of
Drain Port (2.83) (2.83) Drain Port
(3.50) (.91) 15
13 (.59)
(.51)
70
(2.76)

(7.81)
198.5
X 11.14(.4386)
11.11(.4374)

(4.33)
110
Y

(9.000)
(2.311)

228.6
58.7

(5.55)
141
Discharge Port
152.35(5.998) Dia.
44.40(1.748) Dia.

32(1.26) Dia.
49.39(1.944)
49.21(1.937)
44.45(1.750)

152.40(6.000)

"E" Thd. 21.5(.85) Dia. Through


"J" Deep 30.2 24 39(1.54) Dia. Spotface 228.6 R22(R.87)
4 Places (1.189) (.94) (From Rear) (9.000)
26 4Places
273
(1.02) (10.75)
299.5
(11.79) 3
Case Drain Port
5(.20) Hex. Soc.

Surface of
Eye Bolt Pilot Port "PP1"
Safety Valve Pres. M10
362.5 2
Adj. Screw Pilot Port "PP2"
2
24 14(.55) Hex. (14.27) "F" Thd.
Pilot Port "PP1" INC.
(.94) 290
"F" Thd. Flow Adj. Screw
(11.42)
17(.67) Hex. 1
Filling Port
DEC. [27(1.06) Hex. Head Plug Furnished]
(6.97)

(7.56)

Suction Port
177

192

(3.063) 48(1.89) Dia.


77.8

"D" Thd. "H" Deep


View Arrow X 4 Places
42.9
(1.689)
1. Install the pump so that the "Filling Port" is at the top. 299.5
2. Use either port of two pilot and drain ports at your option. Keep the (11.79)
remaining ports plugged. Note that on the European Design Standard View Arrow Y
(6080 Design), only the left side, as viewed from the shaft end, of
the drain port is machined.
3. Case drain port is available for use when draining hydraulic fluid
from pump casing.

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. H mm (IN.) J mm (IN.)
A145-FR07S-60 Rc 3/4 Rc 1/4
M12 M10 19 (.75) 19 (.75)
A145-FR07S-6080 3/4 BSP.F 1/4 BSP. Tr
A145-FR07S-6090 3/4 NPT 1/2-13 UNC 7/16-14 UNC 1/4 NPT 21 (.83) 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)

Foot Mounting Type


Mounting bracket is common to that of pressure compensator model.
Refer to page 23 for the dimensions of mounting bracket.

No.66
"A" Series Piston Pumps
Variable Displacement-Double Pumps PISTON A
Pressure Compensator Type PUMPS
Specifications
Graphic Symbol

M
O

Specifications
Shaft Speed
Geometric Min. Adj. Operating Pressure Approx. Mass
Range
Displacement Flow MPa (PSI) kg (lbs.)
Model Numbers r/min
cm3/rev cm3/rev
2 1 Flange Foot
(cu.in./rev) (cu.in./rev) Rated Intermittent Max. Min.
Mtg. Mtg.
3 Outboard Pump 15.8 (.964) 4 (.244) 16 (2320) 21 (3050) 35.5 37.7
A1616-∗R01∗01∗∗K-32∗ 1800 600
Inboard Pump 15.8 (.964) 4 (.244) 16 (2320) 21 (3050) (98.3) (83.1)
3 Outboard Pump 15.8 (.964) 4 (.244) 16 (2320) 21 (3050) 35.5 37.7
A1622-∗R01∗01∗∗K-32∗ 1800 600
Inboard Pump 22.2 (1.355) 6 (.366) 16 (2320) 16 (2320) (98.3) (83.1)
3 Outboard Pump 22.2 (1.355) 6 (.366) 16 (2320) 16 (2320) 35.5 37.7
A2222-∗R01∗01∗∗K-32∗ 1800 600
Inboard Pump 22.2 (1.355) 6 (.366) 16 (2320) 16 (2320) (98.3) (83.1)
3 Outboard Pump 15.8 (.964) 4 (.244) 16 (2320) 21 (3050) 50 54.3
A1637-∗R01∗01∗∗K-32∗ 1800 600
Inboard Pump 36.9 (2.25) 10 (.610) 16 (2320) 21 (3050) (110) (120)
3 Outboard Pump 22,2 (1.355) 6 (.366) 16 (2320) 16 (2320) 50 54.3
A2237-∗R01∗01∗∗K-32∗ 1800 600
Inboard Pump 36.9 (2.25) 10 (.610) 16 (2320) 21 (3050) (110) (120)
Outboard Pump 15.8 (.964) 4 (.244) 16 (2320) 21 (3050) 54.5 58.8
A1656-∗R01∗01∗∗K-32∗ 1800 600
Inboard Pump 56.2 (3.43) 12 (.732) 16 (2320) 21 (3050) (120) (130)
Outboard Pump 22.2 (1.355) 6 (.366) 16 (2320) 16 (2320) 54.5 58.8
A2256-∗R01∗01∗∗K-32∗ 1800 600
Inboard Pump 56.2 (3.43) 12 (.732) 16 (2320) 21 (3050) (120) (130)
Outboard Pump 15.8 (.964) 4 (.244) 16 (2320) 21 (3050) 77.5 89.5
A1670-∗R01∗01∗∗-60∗ 1800 600
Inboard Pump 70.0 (4.27) 30 (1.831) 25 (3630) 28 (4060) (171) (197)
Outboard Pump 22.2 (1.355) 6 (.366) 16 (2320) 16 (2320) 77.5 89.5
A2270-∗R01∗01∗∗-60∗ 1800 600
Inboard Pump 70.0 (4.27) 30 (1.831) 25 (3630) 28 (4060) (171) (197)
3 Outboard Pump 36.9 (2.25) 10 (.610) 16 (2320) 21 (3050) 86.5 98.5
A3770-∗R01∗01∗∗-60∗ 1800 600
Inboard Pump 70.0 (4.27) 30 (1.831) 25 (3630) 28 (4060) (191) (217)
Outboard Pump 15.8 (.964) 4 (.244) 16 (2320) 21 (3050) 88 108.5
A1690-∗R01∗01∗∗-60∗ 1800 600
Inboard Pump 91.0 (5.55) 56 (3.42) 25 (3630) 28 (4060) (194) (239)
Outboard Pump 22.2 (1.355) 6 (.366) 16 (2320) 16 (2320) 88 108.5
A2290-∗R01∗01∗∗-60∗ 1800 600
Inboard Pump 91.0 (5.55) 56 (3.42) 25 (3630) 28 (4060) (194) (239)
Outboard Pump 36.9 (2.25) 10 (.610) 16 (2320) 21 (3050) 100.5 121
A3790-∗R01∗01∗∗-60∗ 1800 600
Inboard Pump 91.0 (5.55) 56 (3.42) 25 (3630) 28 (4060) (222) (267)
Outboard Pump 56.2 (3.43) 12 (.732) 16 (2320) 21 (3050) 107.5 128
A5690-∗R01∗01∗∗-60∗ 1800 600
Inboard Pump 91.0 (5.55) 56 (3.42) 25 (3630) 28 (4060) (237) (282)
Outboard Pump 15.8 (.964) 4 (.244) 16 (2320) 21 (3050) 109 134
A16145-∗R01∗01∗∗-60∗ 1800 600
Inboard Pump 145 (8.85) 83 (5.06) 25 (3630) 28 (4060) (240) (295)
Outboard Pump 22.2 (1.355) 6 (.366) 16 (2320) 16 (2320) 109 134
A22145-∗R01∗01∗∗-60∗ 1800 600
Inboard Pump 145 (8.85) 83 (5.06) 25 (3630) 28 (4060) (240) (295)
3 Outboard Pump 36.9 (2.25) 10 (.610) 16 (2320) 21 (3050) 121.5 146.5
A37145-∗R01∗01∗∗-60∗ 1800 600
Inboard Pump 145 (8.85) 83 (5.06) 25 (3630) 28 (4060) (268) (323)
3 Outboard Pump 56.2 (3.43) 12 (.732) 16 (2320) 21 (3050) 128.5 153.5
A56145-∗R01∗01∗∗-60∗ 1800 600
Inboard Pump 145 (8.85) 83 (5.06) 25 (3630) 28 (4060) (283) (338)

1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.
2. When operating the pump exceeding the rated pressure, operating conditions are restricted.
Refer to the page 70 for the details.
3. The maximum input power of these pumps must be restricted, because of the shaft strength.
Refer to the page 70 for the details.

No.67
"A" Series Piston Pumps
Variable Displacement-Double Pumps PISTON
Pressure Compensator Type PUMPS
Model Number Designation

Model Number Designation


Outboard Pump Inboard Pump (Driven End)
A1637 -F R
01 C 01 C
S K -32 ∗
Direction Port
Series Control Pres. Adj. Range Control Pres. Adj. Range Position of Shaft Design Design
Mounting of
Number Type MPa(PSI) Type MPa(PSI) Outboard Extension Number Std.
Rotation Pump
A1616 B: 1.2- 7 (170-1020)
(15.8/15.8 Viewed C: 1.2-16 (170-2320) 32
cm3/rev) B: 1.2- 7 (170-1020) H: 1.2-21 (170-3050)
from C: 1.2-16 (170-2320)
A1622 Shaft H: 1.2-21 (170-3050)
(15.8/22.2 End 32
cm3/rev) B: 1.2- 7 (170-1020)
A2222 C: 1.2-16 (170-2320)
B: 1.2- 7 (170-1020)
(22.2/22.2
C: 1.2-16 (170-2320) 32
cm3/rev)
A1637 B: 1.2- 7 (170-1020) K:
(15.8/36.9 C: 1.2-16 (170-2320) Keyed 32
cm3/rev) H: 1.2-21 (170-3050) Shaft
A2237 B: 1.2- 7 (170-1020)
(22.2/36.9
C: 1.2-16 (170-2320) 32
cm3/rev) B: 1.2- 7 (170-1020)
C: 1.5-16 (220-2320)
A1656 B: 1.2- 7 (170-1020) H: 1.8-21 (260-3050)
(15.8/56.2 C: 1.2-16 (170-2320) 32
cm3/rev) H: 1.2-21 (170-3050)
A2256 B: 1.2- 7 (170-1020)
(22.2/56.2
C: 1.2-16 (170-2320) 32
cm3/rev)
A1670 F: B: 1.2- 7 (170-1020) S:
(15.8/70.0 Flange C: 1.2-16 (170-2320) Side Port 60
cm3/rev) Mtg. H: 1.2-21 (170-3050)
A2270 R: 1 01: 01:
B: 1.2- 7 (170-1020)
(22.2/70.0 Clockwise Pressure C: 1.2-16 (170-2320) Pressure 60
cm3/rev) (Normal) Compen- Compen-
sator Type sator Type Refer to
A3770 L: 3
(36.9/70.0 Foot None: 2 60
cm3/rev) Mtg. B: 1.2- 7 (170-1020) Axial Port
C: 1.2-16 (170-2320)
A1690 H: 1.2-21 (170-3050)
(15.8/91.0 60
cm3/rev)
A2290 B: 1.2- 7 (170-1020)
(22.2/91.0
C: 1.2-16 (170-2320) 60
cm3/rev)
B: 1.2- 7 (220-1020)
A3790 C: 1.5-16 (220-2320) None:
(36.9/91.0
H: 1.8-21 (260-3050) Keyed 60
cm3/rev) Shaft
K: 2.0-28 (290-4060)
A5690 B: 1.2- 7 (170-1020)
(56.2/91.0 C: 1.2-16 (170-2320) 60
cm3/rev) H: 1.2-21 (170-3050)
A16145
(15.8/145 60
cm3/rev)
A22145
B: 1.2- 7 (170-1020)
(22.2/145
C: 1.2-16 (170-2320) 60
cm3/rev)
A37145
(36.9/145 60
cm3/rev) B: 1.2- 7 (170-1020)
C: 1.2-16 (170-2320)
A56145 H: 1.2-21 (170-3050)
(56.2/145 60
cm3/rev)
1. Available to supply pump with anti-clockwise rotation. Consult Yuken 3. Design Standards: None ........... Japanese Standard "JIS"
for details. 80 ............... European Design Standard
90 ............... N. American Design Standard
2. "Axial Port Type" is not available for N. American Design Standard of
A3770, A3790, A37145, A5690 and A56145 types.

No.68
"A" Series Piston Pumps
Variable Displacement-Double Pumps PISTON A
Pressure Compensator Type PUMPS
Pipe Flange Kits

Pipe Flange Kits


Pipe flange kits are available. When ordering, specify the kit number from the table below.
Pipe Flange Kit Numbers

Pump Threaded Connection Socket Welding Butt Welding


Model Name of Port Japanese Japanese
Numners Japanese European N. Ameraican Std. "JIS" & N. Ameraican Std. "JIS" & N. Ameraican
Std. "JIS" Design Std. Design Std. European Design Std. European Design Std.
Design Std. Design Std.
Suction & Discharge,
A1616 Outboard Pump
A1622 F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090
A2222 Suction & Discharge,
Inboard Pump
Suction & Discharge,
F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090
A1637 Outboard Pump
A2237 Suction & Discharge,
F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
Inboard Pump
Suction & Discharge,
F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090
A1656 Outboard Pump
A2256 Suction & Discharge,
F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
Inboard Pump
Suction & Discharge,
F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090
A1670 Outboard Pump
A2270 Suction, Inboard Pump F5-12-A-10 F5-12-A-1080 F5-12-A-1090 F5-12-B-10 F5-12-B-1090 F5-12-C-10 F5-12-C-1090
Discharge, Inboard Pump F5-08-A-10 F5-08-A-1080 F5-08-A-1090 F5-08-B-10 F5-08-B-1090 F5-08-C-10 F5-08-C-1090
Suction & Discharge,
F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
Outboard Pump
A3770
Suction, Inboard Pump F5-12-A-10 F5-12-A-1080 F5-12-A-1090 F5-12-B-10 F5-12-B-1090 F5-12-C-10 F5-12-C-1090
Discharge, Inboard Pump F5-08-A-10 F5-08-A-1080 F5-08-A-1090 F5-08-B-10 F5-08-B-1090 F5-08-C-10 F5-08-C-1090
Suction & Discharge,
F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090
A1690 Outboard Pump
A2290 Suction, Inboard Pump F5-16-A-10 F5-16-A-1080 F5-16-A-1090 F5-16-B-10 F5-16-B-1090 F5-16-C-10 F5-16-C-1090
Discharge, Inboard Pump F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
Suction & Discharge,
F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
A3790 Outboard Pump
A5690 Suction, Inboard Pump F5-16-A-10 F5-16-A-1080 F5-16-A-1090 F5-16-B-10 F5-16-B-1090 F5-16-C-10 F5-16-C-1090
Discharge, Inboard Pump F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
Suction & Discharge,
F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090
A16145 Outboard Pump
A22145 Suction, Inboard Pump F5-16-A-10 F5-16-A-1080 F5-16-A-1090 F5-16-B-10 F5-16-B-1090 F5-16-C-10 F5-16-C-1090
Discharge, Inboard Pump F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
Suction & Discharge,
F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
A37145 Outboard Pump
A56145 Suction, Inboard Pump F5-16-A-10 F5-16-A-1080 F5-16-A-1090 F5-16-B-10 F5-16-B-1090 F5-16-C-10 F5-16-C-1090
Discharge, Inboard Pump F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of the
flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used.
Details of the pipe flange kits are given in the Catalogue No. Pub. EC-3001.

No.69
"A" Series Piston Pumps
Variable Displacement-Double Pumps PISTON
Pressure Compensator Type PUMPS
Instructions / Performance Characteristics

Instructions
When using at a higher pressure than the rated pressure One Cycle Time 21 MPa (3050 PSI)
1/5 of One Cycle 1
Max. 6s [28 MPa (4060 PSI)]
Care should be taken in cases of used at a higher pressure than the rated
pressure, because operating terms may be restricted. For example, if used
as per maximum illustrated operating conditions, intermittent time at Pressure
maximum flow is restricted to under 1/5 of one cycle time and under 6
seconds simultaneously. Conditions may vary according to the actual
working pressure and delivery (inclination angle of the swash plate).
Consult factory or Yuken sales representative for further information. Max.

Allowable Input Power Output Flow


With the pumps listed in the table below, there is a limit to the sum of the 0
input power of the inboard and outboard pumps because of shaft strength. 20 MPa (2900 PSI)
1
If both pumps are used for boosting at once, referring to the calculation [27 MPa (3920 PSI)]
formulas below, check that the displacements and discharge pressures of
both pumps are within the allowable ranges. 1. Applicable only for the inboard pump of "A∗70", "A∗90" and
"A∗145".

Q1 × P1 + Q2 × P2 <
= LM Q1 × P1 + Q2 × P2 <
= LP
3
Q1 : Displacement (cm /rev) Q1 : Displacement (cu.in./rev)
Outboard Pump Outboard Pump
P1 : Discharge Pressure (MPa) P1 : Discharge Pressure (PSI)
Q2 : Displacement (cm3/rev) Q2 : Displacement (cu.in./rev)
Inboard Pump Inboard Pump
P2 : Discharge Pressure (PSI) P2 : Discharge Pressure (PSI)
LM : See the table below L P : See the table below

Model Numbers LM LP
A1616/A1622/A2222 523 4627
A1637/A2237 900 7963
A3770 2408 21305
A37145/A56145 4739 41930

Performance Characteristics
Refer to relevant the page for performance characteristics of single pumps excluding noise level characteristics.
Outboard Pump Inboard Pump
Model Numbers Reference Reference
Performance Characteristics Performance Characteristics
Page Page
A1616-∗R01∗01∗∗K-32∗ Same as Single Pump "A16" 10 Same as Single Pump "A16" 10
A1622-∗R01∗01∗∗K-32∗ Same as Single Pump "A16" 10
Same as Single Pump "A22" 11
A2222-∗R01∗01∗∗K-32∗ Same as Single Pump "A22" 11
A1637-∗R01∗01∗∗K-32∗ Same as Single Pump "A16" 10
Same as Single Pump "A37" 12
A2237-∗R01∗01∗∗K-32∗ Same as Single Pump "A22" 11
A1656-∗R01∗01∗∗K-32∗ Same as Single Pump "A16" 10
Same as Single Pump "A56" 13
A2256-∗R01∗01∗∗K-32∗ Same as Single Pump "A22" 11
A1670-∗R01∗01∗∗-60∗ Same as Single Pump "A16" 10
A2270-∗R01∗01∗∗-60∗ Same as Single Pump "A22" 11 Same as Single Pump "A70" 14
A3770-∗R01∗01∗∗-60∗ Same as Single Pump "A37" 12
A1690-∗R01∗01∗∗-60∗ Same as Single Pump "A16" 10
A2290-∗R01∗01∗∗-60∗ Same as Single Pump "A22" 11
Same as Single Pump "A90" 15
A3790-∗R01∗01∗∗-60∗ Same as Single Pump "A37" 12
A5690-∗R01∗01∗∗-60∗ Same as Single Pump "A56" 13
A16145-∗R01∗01∗∗-60∗ Same as Single Pump "A16" 10
A22145-∗R01∗01∗∗-60∗ Same as Single Pump "A22" 11
Same as Single Pump "A145" 16
A37145-∗R01∗01∗∗-60∗ Same as Single Pump "A37" 12
A56145-∗R01∗01∗∗-60∗ Same as Single Pump "A56" 13

No.70
"A" Series Piston Pumps
A1616 / A1622 / A2222-∗R01∗01∗ PISTON
PUMPS
A
Installation Drawing
Flange Mtg. : A1616-FR01∗01∗K-32/3280/3290
A1622-FR01∗01∗K-32/3280/3290
A2222-FR01∗01∗K-32/3280/3290
Fully Extended 44.5
448.5 (1.75)
(17.66)
288.5 6.5(.26)
(11.36)
256
1 (10.08)
Filling Port 59(2.32)
[22(.87) Hex. Head Plug Furnished] Drain Port "C" Thd.
26.5
(1.04)
4.79(.1886)
Y 25(.98) 4.76(.1874)
(4.29)

(3.78)

(3.78)
109

96

(2.44)

96
47.6(1.874)
62
(7.36)

12(.47)
187

(.71)
X

18
82.50(3.248) Dia.
19.02(.7488) Dia.
R12
95(3.74) Dia. (R.47)
19.05(.7500)

82.55(3.250)
21.24(.836)
21.08(.830)
Outboard Pump 22.2 12 106
(.874) (.47) (4.17)
150.5 130
(5.93) (5.12)
401.5 74 74
(15.81)
Inboard Pump (2.91) (2.91)
"D" Thd. 17(.67) Deep Surface of Discharge Port Surface of Suction Port
Discharge Port 19 (.75) Dia. 188
4 Places (Both Sides)
Rear Side (7.40)
Suction Port 19 (.75) Dia.
16 16
Flow Adj. Screw (.63) (.63) Pressure Adj. Screw 16 16
17(.67) Hex. 17(.67) Hex. INC. (.63) (.63)
Flow Adj. Screw Pressure Adj. Screw
DEC. 17(.67) Hex. 17(.67) Hex.

DEC. INC.
(1.874)
47.6

View Arrow Y
"D" Thd. 17(.67) Deep
22.2 8 Places
Suction Port (.874)
19(.75) Dia. 65 Discharge Port
19 (.75) Dia.
(2.56)

View Arrow X
1. Install the pump so that the "Filling Port" is at the top.
Model Numbers "C" Thd. "D" Thd.
A1616/A1622/A2222-FR01∗01∗K-32 Rc 3/8
M10
A1616/A1622/A2222-FR01∗01∗K-3280 3/8 BSP. F
A1616/A1622/A2222-FR01∗01∗K-3290 3/8 NPT 3/8-16 UNC

DIMENSIONS IN
Foot Mtg. : A1616-LR01∗01∗K-32/3280/3290 MILLIMETRES (INCHES)
A1622-LR01∗01∗K-32/3280/3290 12(.47) Dia. Through
A2222-LR01∗01∗K-32/3280/3290 24(.94) Dia. Spotface
4 Places
(3.15)
(.59)
(.55)
15
3(.12)

14

80

50 56.5 95
(3.74)
(1.969) (2.22)
95 27.5 72.5 72.5
(3.74) (1.08) (2.854) (2.854)
180
(7.09)
For other dimensions, refer to "Flange Mtg.".

No.71
"A" Series Piston Pumps
A1637 / A2237-∗R01∗01∗ PISTON
Installation Drawing
PUMPS
Flange Mtg. : A1637-FR01∗01∗K-32/3280/3290
A2237-FR01∗01∗K-32/3280/3290
Fully Extended
471.5 62(2.44)
(18.56)
311.5 9.5(.37)
(12.26)
Drain Port "D" Thd. 279
1
(10.98) Filling Port
77 [22(.87) Hex. Head Plug Furnished]
(3.03) 202
1 30 (7.95)
Filling Port

(2.311)
58.7
[22(.87) Hex. Head Plug Furnished] (1.18) 174
Drain Port "C" Thd. (6.85)
7.97(.3138)
40 7.94(.3126)
Y
(4.29)
(4.41)

(4.13)
(3.78)

(1.57)
109
112

105
96

(2.44)
62
(7.95)
202

(.98)
(.55)
X

25
14
(3.07)
78

101.55(3.998) Dia.
31.70(1.248) Dia.
R14
120(4.72) Dia. (R.55)

101.60(4.000)
31.75(1.250)

35.32(1.391)
35.14(1.383)
Outboard Pump 30.2 12 146
(1.189) (.47) (5.75)
178.5 86 86
(7.03) (3.39) (3.39)
Surface of Surface of
424.5
Discharge Port Suction Port
(16.71) Inboard Pump
"E" Thd. "H" Deep Discharge Port 32 (1.26) Dia.
4 Places (Both Sides) Rear Side
Suction Port 32 (1.26) Dia.
16 16
Flow Adj. Screw (.63) (.63) Pressure Adj. Screw
17(.67) Hex. 17(.67) Hex.
INC.
DEC. 13 19
Flow Adj. Screw (.51) (.75)
17(.67) Hex. Pressure Adj. Screw
17(.67) Hex.
(1.874)
47.6

DEC. INC.

"F" Thd. 17(.67) Deep View Arrow Y


22.2 8 Places
Suction Port (.874)
19(.75) Dia. 65 Discharge Port
(2.56) 19 (.75) Dia.

View Arrow X
1. Install the pump so that the "Filling Port" is at the top.
Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" mm (IN.)
A1637/A2237-FR01∗01∗K-32 Rc 1/2 Rc 3/8
M10 M10 19 (.75)
A1637/A2237-FR01∗01∗K-3280 1/2 BSP.F 3/8 BSP.F
A1637/A2237-FR01∗01∗K-3290 1/2 NPT 3/8 NPT 7/16-14 UNC 3/8-16 UNC 20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg. : A1637-LR01∗01∗K-32/3280/3290
A2237-LR01∗01∗K-32/3280/3290
14(.55) Dia. Through
28(1.10) Dia. Spotface
4 Places
(4.02)
(.59)
(.55)

102
3(.12)

15
14

60 77 120
(2.362)(3.03) (4.72)
115 42 95 95
(4.53) (1.65) (3.740) (3.740)
230
(9.06)
For other dimensions, refer to "Flange Mtg.".

No.72
"A" Series Piston Pumps
A1656 / A2256-∗R01∗01∗ PISTON
PUMPS
A
Installation Drawing
Flange Mtg. : A1656-FR01∗01∗K-32/3280/3290
A2256-FR01∗01∗K-32/3280/3290
62
Fully Extended (2.44)
484(19.06)
324 9.5
(12.76) (.37)
Drain Port "D" Thd.
291.5
(11.48) Filling Port
1
50.5(1.99)

58.7(2.311)
1 [22(.87) Hex. Head Plug Furnished] Surface of
Filling Port 2 Drain Port
[22(.87) Hex. Head Plug Furnished] 43.5(1.71) Drain Port
"C" Thd. 41 49
(1.61) (1.93)
40
7.97(.3138)
(1.57)
(5.43)

7.94(.3126)
Y
(4.29)
138

(3.78)

(3.54)
109

96

90
(9.29)
236

(.98)
(.55)
X

25
14
(2.44)
(3.07)

62
78

31.70(1.248) Dia.

101.55(3.998) Dia.
35.32(1.391)
35.14(1.383)
101.60(4.000)
31.75(1.250)
R14
30.2 12 146 (R.55)
Outboard Pump (1.189) (.47) (5.75)
120(4.72) Dia.
191 174
(7.52) (6.85)
437 100 100
(17.20) Inboard Pump (3.94) (3.94)
"E" Thd. "H" Deep Discharge Port 30 (1.18) Dia. Surface of 232 Surface of
4 Places (Both Sides) Rear Side Discharge Port (9.13) Suction Port
Suction Port 35 (1.38) Dia.
16 16
(.63) (.63)

Flow Adj. Screw Pressure Adj. Screw 13 19


17(.67) Hex. 17(.67) Hex. (.51) (.75)
Flow Adj. Screw Pressure Adj. Screw
INC. 17(.67) Hex. 17(.67) Hex.
(1.874)

DEC.
47.6

INC.
DEC.

"F" Thd. 17(.67) Deep


8 Places View Arrow Y
Suction Port 22.2
19(.75) Dia. Discharge Port
(.874) 19 (.75) Dia. 1. Install the pump so that the "Filling Port" is at the top.
65
(2.56) 2. Use either port of two drain ports of inboard pump at your option.
Keep the remaining port plugged.
View Arrow X Note that on the European design standard (3280 Design), only the
left side, as viewed from the shaft end, of the drain port is machined.

Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd. "H" mm (IN.)
A1656/A2256-FR01∗01∗K-32 Rc 3/4 Rc 3/8
M10 M10 19 (.75)
A1656/A2256-FR01∗01∗K-3280 3/4 BSP.F 3/8 BSP.F
A1656/A2256-FR01∗01∗K-3290 3/4 NPT 3/8 NPT 7/16-14 UNC 3/8-16 UNC 20 (.79)

DIMENSIONS IN
Foot Mtg. : A1656-LR01∗01∗K-32/3280/3290 MILLIMETRES (INCHES)
A2256-LR01∗01∗K-32/3280/3290

14(.55) Dia. Through


28(1.10) Dia. Spotface
4 Places
(4.02)
(.55)

(.59)
3(.12)

102
14

15

60 77 120
(2.362) (3.03) (4.72)
115 42 95 95
(4.53) (1.65) (3.740) (3.740)
230
(9.06)

For other dimensions, refer to "Flange Mtg.".

No.73
"A" Series Piston Pumps
A1670 / A2270 / A3770-∗R01∗01∗ PISTON
Installation Drawing
PUMPS
Flange Mtg. : A1670-FR01∗01∗S-60/6080/6090
A2270-FR01∗01∗S-60/6080/6090 DIMENSIONS IN
A3770-FR01∗01∗S-60/6080/6090 MILLIMETRES (INCHES)
62
Fully Extended (2.44)
E Surface of Discharge Port Surface of Suction Port
95 95
19.5(.77)
F (3.74) (3.74)
Drain Port 9.5(.37) Surface of Drain Port Surface of Drain Port
H 73 73
"b" Thd. 65 Drain Port 2 7.97(.3138)

(2.063)
1 (2.56) "a" Thd. (Both Sides) (2.87) (2.87) 7.94(.3126)

52.4
Filling Port 27(1.06) Dia.
40 Spotface
[22(.87) Hex. Head Plug Furnished]
(1.57) (From Rear)

(.55)

(7.17)
14

182
4 Places

(3.54)
90

(4.504)
X Y

(7.09)
114.4
(.71)

180
18
Q

(4.65)
118
Discharge Port

31.70(1.248) Dia.

126.95(4.998) Dia.
"S" Dia. 35(1.38) Dia.
Spotface

35.32(1.391)
35.14(1.383)
127.00(5.000)
31.75(1.250)
"f" Thd. "j" Deep P 16 (From Rear)
26.2 (.63) 114.4
4 Places 2 Places
(1.031) 18 (4.504)
Inboard Pump 134
(.71)
246.5 (5.28)
Discharge Port
(9.70) 181
26 (1.02) Dia.
(7.126)
J 211
"e" Thd. 17(.67) Deep Outboard Pump (8.31)
4 Places

1 Eye Bolt M10


Filling Port Flow Adj. Screw
(2.752)

[27(1.06) Hex. Head Plug Furnished] Suction Port 17(.67) Hex.


69.9

38 (1.50) Dia.
DEC.
Flow Adj. Screw Pres. Adj. Screw Z Pres. Adj. Screw
17(.67) Hex. 17(.67) Hex. 17(.67) Hex.
DEC. INC. INC.
K
Q

Suction Port View Arrow Z


"S" Dia.
3 "f" Thd. "j" Deep
N N Case Drain Port P
5 (.20) Hex. Soc. 35.7 4 Places
Surface of Surface of (1.406)
Suction Port L Discharge Port 246.5 "d" Thd. "h" Deep
(9.70) 4 Places
View Arrow X J

View Arrow Y
1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of two drain ports of inboard pump at your option. Keep the remaining port plugged. Note that on the European design standard
(6080 Design), only the left side, as viewed from the shaft end, of the drain port of inboard pump is machined.
3. Case drain port is available for use when draining hydraulic fluid from pump casing.

Dimensions mm (Inches)
Model Numbers
E F H J K L N P Q S
A1670-∗R01∗01∗S-60∗ 524.5 364.5 332 456 96 188 74 22.2 47.6 19
A2270-∗R01∗01∗S-60∗ (20.65) (14.35) (13.07) (17.95) (3.78) (7.40) (2.91) (.874) (1.874) (.75)

A3770-∗R01∗01∗S-60∗
552.5 382.5 335.5 484 105 202 86 30.2 58.7 32
(20.65) (15.06) (13.21) (19.06) (4.13) (7.95) (3.39) (1.189) (1.311) (1.26)

Thread Size mm (Inches)


Model Numbers
a b d e f h j
A1670/A2270-∗R01∗01∗S-60 Rc 3/4 Rc 3/8
M12 M10 M10 19 (.75)
A1670/A2270-∗R01∗01∗S-6080 3/4 BSP.F 3/8 BSP.F 17 (.67)
A1670/A2270-∗R01∗01∗S-6090 3/4 NPT 3/8 NPT 1/2-13 UNC 3/8-16 UNC 3/8-16 UNC 21 (.83)
A3770-∗R01∗01∗S-60 Rc 3/4 Rc 1/2
M12 M10 M10 19 (.75) 19 (.75)
A3770-∗R01∗01∗S-6080 3/4 BSP.F 1/2 BSP.F
A3770-∗R01∗01∗S-6090 3/4 NPT 1/2 NPT 1/2-13 UNC 3/8-16 UNC 7/16-14 UNC 21 (.83) 20 (.79)

Foot Mounting Type


The mounting bracket is common that of single pump A70. Refer to page 21 for the dimensions of mounting bracket.

No.74
"A" Series Piston Pumps
A1690 / A2290 / A3790-∗R01∗01∗ PISTON
PUMPS
A
Installation Drawing
Flange Mtg. : A1690-FR01∗01∗S-60/6080/6090
A2290-FR01∗01∗S-60/6080/6090 DIMENSIONS IN
A3790-FR01∗01∗S-60/6080/6090 MILLIMETRES (INCHES)
95
Fully Extended (3.74)
E
Surface of Surface of
23(.91) Discharge Port Suction Port
F 105 105
13(.51) (4.13) (4.13)
Drain Port "b" Thd. H
2 Surface of Surface of
119.5 Drain Port Drain Port Drain Port
68 68
(2.311) (4.70) "a" Thd. (Both Sides)
(2.68) (2.68)
58.7
1
Filling Port 63
[22(.87) Hex. Head Plug Furnished] (2.48)
9.56

(7.50)
190.5
9.53

(4.45)
113
(.3764)

(6.362)
X (.3752)

161.6
Y
Q

(5.00)
127
Discharge Port

152.35(5.998) Dia.
38.05(1.498) Dia.

"S" Dia.
P
38.10(1.500)

42.36(1.668)
42.18(1.661)
"f" Thd. "j" Deep 30.2
22 152.40(6.000) 161.6
4 Places (.87) R22(R.87)
(1.189) (6.362)
Outboard Pump 23
(.91) 21.5(.85) Dia. Through
"e" Thd. "h" Deep 270 39(1.54) Dia. Spotface
4 Places (10.63) (From Rear)
Inboard Pump 4 Places
J
Discharge Port Case Drain Port 3
32 (1.26) Dia. 5 (.20) Hex. Soc.

1 Eye Bolt M10


Filling Port
(3.063)

Suction Port Flow Adj. Screw


77.8

[27(1.06) Hex. Head Plug Furnished]


48(1.89) Thd. 17(.67) Hex.
Z DEC.
Flow Adj. Screw Pres. Adj. Screw Pres. Adj. Screw
17(.67) Hex. 17(.67) Hex. 17(.67) Hex.
DEC.
K

INC. INC.
Q

View Arrow Z
Suction Port
N N P "S" Dia.
42.9 "f" Thd. "j" Deep
(1.689) 4 Places
Surface of Surface of
Suction Port L Discharge Port 270 "d" Thd. "h" Deep
(10.63) 4 Places
View Arrow X J

View Arrow Y
1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of two drain ports of inboard pump at your option. Keep the remaining port plugged. Note that on the European design standard
(6080 Design), only the left side, as viewed from the shaft end, of the drain port of inboard pump is machined.
3. Case drain port is available for use when draining hydraulic fluid from pump casing.
Dimensions mm (Inches)
Model Numbers
E F H J K L N P Q S
A1690-∗R01∗01∗S-60∗ 543 383 350.5 474.5 96 188 74 22.2 47.6 19
A2290-∗R01∗01∗S-60∗ (21.38) (15.08) (13.80) (18.68) (3.78) (7.40) (2.91) (.874) (1.874) (.75)

A3790-∗R01∗01∗S-60∗
571 401 354 502.5 105 202 86 30.2 58.7 32
(22.48) (15.79) (13.94) (19.78) (4.13) (7.95) (3.39) (1.189) (1.311) (1.26)

Thread Size mm (Inches)


Model Numbers
a b d e f h j
A1690/A2290-∗R01∗01∗S-60 Rc 3/4 Rc 3/8
M12 M10 M10 19 (.75)
A1690/A2290-∗R01∗01∗S-6080 3/4 BSP.F 3/8 BSP.F 17 (.67)
A1690/A2290-∗R01∗01∗S-6090 3/4 NPT 3/8 NPT 1/2-13 UNC 7/16-14 UNC 3/8-16 UNC 21 (.83)
A3790-∗R01∗01∗S-60 Rc 3/4 Rc 1/2
M12 M10 M10 19 (.75) 19 (.75)
A3790-∗R01∗01∗S-6080 3/4 BSP.F 1/2 BSP.F
A3790-∗R01∗01∗S-6090 3/4 NPT 1/2 NPT 1/2-13 UNC 7/16-14 UNC 7/16-14 UNC 21 (.83) 20 (.79)

Foot Mounting Type


The mounting bracket is common that of single pump A90. Refer to page 22 for the dimensions of mounting bracket.

No.75
"A" Series Piston Pumps
A5690-∗R01∗01∗ PISTON
Installation Drawing
PUMPS
Flange Mtg. : A5690-FR01∗01∗S-60/6080/6090

DIMENSIONS IN
MILLIMETRES (INCHES)
Discharge Port
32 (1.26) Dia. 95
Fully Extended (3.74)
583.5(22.98) Surface of Surface of
374.5 23(.91) Discharge Port Suction Port
105 105
1 (14.74)
Filling Port 13(.51) (4.13) (4.13)
367.5
[22(.87) Hex. Head Plug Furnished] Surface of
2 (14.47) 2 Surface of
Drain Port 119.5 Drain Port Drain Port 68 68 Drain Port
"D" Thd. (Both Sides) (4.70) "C" Thd. (Both Sides)
(2.311) (2.68) (2.68)
58.7

Outboard Pump 63
(2.48)
9.56

(7.50)
190.5
9.53

(4.45)
(.3764)

113
(2.311)

(6.362)
X (.3752)

161.6
Y
58.7

(5.00)
127
38.05(1.498) Dia.

152.35(5.998) Dia.
Discharge Port
30 (1.18) Dia.
42.36(1.668)
42.18(1.661)
38.10(1.500)

30.2
152.40(6.000)
22
"F" Thd. "J" Deep (1.189) 30.2 161.6 R22(R.87)
(.87)
4 Places (1.189) (6.362)
23
"F" Thd. "H" Deep (.91) 21.5(.85) Dia. Through
4 Places 270 39(1.54) Dia. Spotface
(10.63) (From Rear)
Inboard Pump 4 Places
515
(20.28) 3
Case Drain Port
5 (.20) Hex. Soc.

Flow Adj. Screw


1 17(.67) Hex.
Filling Port
Eye Bolt M10 DEC.
[27(1.06) Hex. Head Plug Furnished]
(3.063)

Suction Port
Pres. Adj. Screw
77.8

48(1.89) Dia.
17(.67) Hex.
Flow Adj. Screw Pres. Adj. Screw Z
17(.67) Hex. 17(.67) Hex. INC.
DEC. INC.
(3.54)
58.7(2.311)
90

View Arrow Z

Suction Port
35(1.38) Dia.
100 100 30.2
(3.94) (3.94) 42.9 (1.189) "F" Thd. "J" Deep
(1.689) 4 Places
Surface of Surface of
232 Discharge Port 270 "E" Thd. "H" Deep
Suction Port
(9.13) (10.63) 4 Places
515
View Arrow X (20.28)

View Arrow Y

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports of inboard and outboard pump at your option. Keep the remaining ports plugged. Note that on the European
design standard (6080 Design), only the left side, as viewed from the shaft end, of the drain port of inboard and outboard pump is machined.
3. Case drain port is available for use when draining hydraulic fluid from pump casing.

Thread Size mm (Inches)


Model Numbers
C D E F H J
A5690-∗R01∗01∗S-60 Rc 3/4 Rc 1/2
M12 M10 19 (.75) 19 (.75)
A5690-∗R01∗01∗S-6080 3/4 BSP.F 1/2 BSP.F
A5690-∗R01∗01∗S-6090 3/4 NPT 1/2 NPT 1/2-13 UNC 7/16-14 UNC 21 (.83) 20 (.79)

Foot Mounting Type


The mounting bracket is common that of single pump A90. Refer to page 22 for the dimensions of mounting bracket.

No.76
"A" Series Piston Pumps
A16145 / A22145 / A37145-∗R01∗01∗ PISTON
PUMPS
A
Installation Drawing
Flange Mtg. : A16145-FR01∗01∗S-60/6080/6090
A22145-FR01∗01∗S-60/6080/6090 DIMENSIONS IN
A37145-FR01∗01∗S-60/6080/6090 MILLIMETRES (INCHES)
112
Fully Extended (4.41) 143
E (5.63)
Surface of Surface of
23(.91) Discharge Port Suction Port
F 112 112
(4.41) (4.41)
Drain Port 13(.51) 2
Surface of Surface of
"b" Thd. H Drain Port Drain Port 72 72 Drain Port
"a" Thd. (Both Sides)
89
(2.311)
58.7 (2.83) (2.83)
1
Filling Port (3.50) 70
[22(.87) Hex. Head Plug Furnished] (2.76)
11.14

(7.81)
198.5
11.11

(4.33)
(.4386) Y

110

(9.000)
X (.4374)

228.6
Q

(5.55)
141
Discharge Port

152.35(5.998) Dia.
Dia.
"S" Dia.
P
"f" Thd. "j" Deep
44.45(1.750)

152.40(6.000)
44.40(1.748)
49.39(1.944)
4 Places 30.2 24 49.21(1.937) 228.6 R22(.87)
Outboard Pump (1.189) (.94) (9.000)
26 273
"e" Thd. "j" Deep
4 Places (1.02) (10.75)
299.5 21.5(.85) Dia. Through
Discharge Port
(11.79) 39(1.54) Dia. Spotface
32 (1.26) Dia. Inboard Pump (From Rear)
J 3 4 Places
Case Drain Port Eye Bolt M10
5 (.20) Hex. Soc.
Pres. Adj. Screw
(3.063)

1
77.8

Filling Port 17(.67) Hex. INC.


[27(1.06) Hex. Head Plug Furnished]
Flow Adj. Screw
Z 17(.67) Hex.
Flow Adj. Screw Pres. Adj. Screw
17(.67) Hex. 17(.67) Hex.

K
DEC.
Q
DEC. INC.

Suction Port
N N P "S" Dia.
42.9 "f" Thd. "j" Deep
4 Places
Surface of Surface of (1.689)
Suction Port 299.5 "d" Thd. "h" Deep
L Discharge Port
4 Places
(11.79) Suction Port
J 48(1.89) Thd.
View Arrow X View Arrow Y
1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of two drain ports of inboard pump at your option. Keep the remaining port plugged. Note that on the European design standard
(6080 Design), only the left side, as viewed from the shaft end, of the drain port of inboard pump is machined.
3. Case drain port is available for use when draining hydraulic fluid from pump casing.

Dimensions mm (Inches)
Model Numbers
E F H J K L N P Q S
A16145-∗R01∗01∗S-60∗ 576.5 416.5 384 508 96 188 74 22.2 47.6 19
A22145-∗R01∗01∗S-60∗ (22.70) (16.40) (15.12) (20.00) (3.78) (7.40) (2.91) (.874) (1.874) (.75)

A37145-∗R01∗01∗S-60∗
604.5 434.5 387.5 536 105 202 86 30.2 58.7 32
(23.80) (17.11) (15.26) (21.10) (4.13) (7.95) (3.39) (1.189) (1.311) (1.26)

Thread Size mm (Inches)


Model Numbers
a b d e f h j n
A16145/A22145-∗R01∗01∗S-60 Rc 3/4 Rc 3/8
M12 M10 M10 19 (.75) 19 (.75)
A16145/A22145-∗R01∗01∗S-6080 3/4 BSP.F 3/8 BSP.F 17 (.67)
A16145/A22145-∗R01∗01∗S-6090 3/4 NPT 3/8 NPT 1/2-13 UNC 7/16-14 UNC 3/8-16 UNC 21 (.83) 20 (.79)
A37145-∗R01∗01∗S-60 Rc 3/4 Rc 1/2
M12 M10 M10 19 (.75) 19 (.75) 19 (.75)
A37145-∗R01∗01∗S-6080 3/4 BSP.F 1/2 BSP.F
A37145-∗R01∗01∗S-6090 3/4 NPT 1/2 NPT 1/2-13 UNC 7/16-14 UNC 7/16-14 UNC 21 (.83) 20 (.79) 20 (.79)

Foot Mounting Type


The mounting bracket is common that of single pump A145. Refer to page 23 for the dimensions of mounting bracket.

No.77
"A" Series Piston Pumps
A56145-∗R01∗01∗ PISTON
Installation Drawing
PUMPS
Flange Mtg. : A56145-FR01∗01∗S-60/6080/6090

DIMENSIONS IN
MILLIMETRES (INCHES)
143
112
Fully Extended (4.41) (5.63)
617(24.29) Surface of Surface of
408 23(.91) Discharge Port 112 112 Suction Port
1 (16.06) (4.41) (4.41)
Filling Port 401 13(.51)
[22(.87) Hex. Head Plug Furnished] Drain Port 2 Surface of Surface of
(15.79)
2 "C" Thd. (Both Sides) Drain Port Drain Port
Drain Port 89 72 72
"D" Thd. (Both Sides)
(2.311)
(3.50) (2.83) (2.83)
58.7
Outboard Pump 70
(2.76)
11.14

(7.81)
198.5
11.11

(4.33)
110
(.4386)
Y
(2.311)

(9.000)
(.4374)

228.6
58.7

(5.55)
141
152.35(5.998) Dia.
Discharge Port Dia.
30 (1.18) Dia.

152.40(6.000)
30.2
44.45(1.750)

49.39(1.944)
49.21(1.937)
44.40(1.748)

"F" Thd. "J" Deep 228.6


(1.189) 30.2 24 R22(R.87)
4 Places
(1.189) (.94) (9.000)
"F" Thd. "J" Deep 26 273
4 Places (1.02) (10.75)
Discharge Port 299.5 21.5(.85) Dia. Through
32 (1.26) Dia. (11.79) Inboard Pump 39(1.54) Dia. Spotface
548.5 (From Rear)
3
(21.59) Case Drain Port 4 Places
5 (.20) Hex. Soc.
Pres. Adj. Screw
17(.67) Hex. INC.
1
Filling Port Eye Bolt M10 Flow Adj. Screw
[27(1.06) Hex. Head Plug Furnished] 17(.67) Hex.
(3.063)

DEC.
77.8

Flow Adj. Screw Pres. Adj. Screw Z


17(.67) Hex. 17(.67) Hex.
(3.54)
58.7(2.311)
90

DEC. INC.

Suction Port
100 100 30.2 35(1.38) Dia.
(3.94) (3.94) 42.9 (1.189) "E" Thd. "H" Deep
Surface of Surface of (1.689) 4 Places
232 299.5 "d" Thd. "h" Deep
Suction Port Discharge Port
(9.13) (11.79) 4 Places
548.5
View Arrow X (21.59)
Suction Port
48(1.89) Dia.

View Arrow Y

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports of inboard and outboard pump at your option. Keep the remaining ports plugged. Note that on the European
design standard (6080 Design), only the left side, as viewed from the shaft end, of the drain port of inboard and outboard pump is machined.
3. Case drain port is available for use when draining hydraulic fluid from pump casing.

Thread Size mm (Inches)


Model Numbers
C D E F H J
A56145-∗R01∗01∗S-60 Rc 3/4 Rc 1/2
M12 M10 19 (.75) 19 (.75)
A56145-∗R01∗01∗S-6080 3/4 BSP.F 1/2 BSP.F
A56145-∗R01∗01∗S-6090 3/4 NPT 1/2 NPT 1/2-13 UNC 7/16-14 UNC 21 (.83) 20 (.79)

Foot Mounting Type


The mounting bracket is common that of single pump A145. Refer to page 23 for the dimensions of mounting bracket.

No.78
"A" Series Piston Pumps
Double Pumps
Spare Parts List
PISTON
PUMPS
A
A1616-∗R01∗01∗∗K-32/3280/3290
A∗∗22-∗R01∗01∗∗K-32/3280/3290 CAUTION
A∗∗37-∗R01∗01∗∗K-32/3280/3290 When making replacement of seals or bearings,
A∗∗56-∗R01∗01∗∗K-32/3280/3290 please do it carefully after reading through the
A∗∗70-∗R01∗01∗∗-60/6080/6090 relevant instructions in the Operator's Manual.
A∗∗90-∗R01∗01∗∗-60/6080/6090
A∗∗145-∗R01∗01∗∗-60/6080/6090

83 82 80 81

Outboard Pump

Inboard Pump

Seals
Seal KIt Numbers Item 80 O-Ring
Pump Model Numbers
Complete Kit For Outboard Pump For Inboard Pump Part Numbers Qty.
A1616-∗R01∗01∗∗K-32∗
A1622-∗R01∗01∗∗K-32∗ KS-A1616-0101-32 KS-A16-01-32 KS-A16-01-32 S85(NBR,Hs70) 1
A2222-∗R01∗01∗∗K-32∗
A1637-∗R01∗01∗∗K-32∗
KS-A1637-0101-32 KS-A16-01-32 KS-A37-01-32 S85(NBR,Hs70) 1
A2237-∗R01∗01∗∗K-32∗
A1656-∗R01∗01∗∗K-32∗
KS-A1656-0101-32 KS-A16-01-32 KS-A56-01-32 S85(NBR,Hs70) 1
A2256-∗R01∗01∗∗K-32∗
A1670-∗R01∗01∗∗-60∗
KS-A1670-0101-60 KS-A16-01-32 S85(NBR,Hs70) 1
A2270-∗R01∗01∗∗-60∗ KS-A70-01-60
A3770-∗R01∗01∗∗-60∗ KS-A3770-0101-60 KS-A37-01-32 S105(NBR,Hs70) 1
A1690-∗R01∗01∗∗-60∗
KS-A1690-0101-60 KS-A16-01-32 S85(NBR,Hs70) 1
A2290-∗R01∗01∗∗-60∗
A3790-∗R01∗01∗∗-60∗ KS-A3790-0101-60 KS-A37-01-32 KS-A90-01-60
S105(NBR,Hs70) 1
A5690-∗R01∗01∗∗-60∗ KS-A5690-0101-60 KS-A56-01-32
A16145-∗R01∗01∗∗-60∗
KS-A16145-0101-60 KS-A16-01-32 S85(NBR,Hs70) 1
A22145-∗R01∗01∗∗-60∗
A37145-∗R01∗01∗∗-60∗ KS-A37145-0101-60 KS-A37-01-32 KS-A145-01-60
S105(NBR,Hs70) 1
A56145-∗R01∗01∗∗-60∗ KS-A56145-0101-60 KS-A56-01-32
Notes :1 When ordering seals, please specify the seal kit number from the table above.
2 Complete seal kit consists of a seal kit for inboard pump, a seal kit for outboard pump and a piece of O-ring for item 80.
3 Seal kit and bearings for inboard pump and outboard pump are same as those for "A" series single pump. For details,
please refer to the table below and see the chart on the page relevant to pump model number concerned.

Model Inboard Pump Model Outboard Pump


A16∗∗ Same as single pump "A16" (Page 25) A1616 Same as single pump "A16" (Page 25)
A22∗∗ Same as single pump "A22" (Page 25) A∗∗22 Same as single pump "A22" (Page 25)
A37∗∗ Same as single pump "A37" (Page 25) A∗∗37 Same as single pump "A37" (Page 25)
A56∗∗ Same as single pump "A56" (Page 25) A∗∗56 Same as single pump "A56" (Page 25)
A∗∗70 Same as single pump "A70" (Page 26)
A∗∗90 Same as single pump "A90" (Page 26)
A∗∗145 Same as single pump "A145" (Page 27)

No.79
"A" Series Piston Pumps
Variable/Fixed Double Pumps PISTON
A16R1 / A22R1 / A37R1 / A56R1 / A70R1 / A90R1 / A145R1 PUMPS
Model Number Designation

Graphic Symbol

M
O

Model Number Designation


Inboard Pump (Driven End) Outboard Pump
A16R1 -F R
01 B -23 A A
K -32 ∗
Direction Nominal Discharge Suction
Series Pres. Adj. Range Shaft Design Design
Mounting of Control Type Displacement Port Port
Number MPa(PSI) Extension Number Std.
Rotation cm3/rev Position Position

B: 1.2 - 7 (170 - 1020)


A16R1 Viewed C: 1.2 - 16 (170 - 2320) Viewed from 32
from H: 1.2 - 21 (170 - 3050) Shaft End
Shaft
End B: 1.2 - 7 (170 - 1020)
A22R1 32
C: 1.2 - 16 (170 - 2320) K:
Keyed
Shaft
A37R1 F: 32
B: 1.2 - 7 (170 - 1020)
Flange C: 1.2 - 16 (170 - 2320) 6, 8
Mtg. H: 1.2 - 21 (170 - 3050) 10, 12
A56R1 14, 17 32
R: 1 01:
19, 23
Clockwise Pressure 25, 31 A: Up A: Up
L: (Normal) Compensator
A70R1 Foot Type 60
Mtg.
B: 1.2 - 7 (170 - 1020) Refer to
C: 1.5 - 16 (220 - 2320) 2
A90R1 H: 1.8 - 21 (260 - 3050) 60
K: 2.0 - 28 (290 - 4060)
A145R1 60
None:
Keyed
Shaft
A70R2 60
B: 1.2 - 7 (170 - 1020) 41, 47
C: 1.5 - 16 (220 - 2320) 53, 59
A90R2 60
H: 1.8 - 21 (260 - 3050) 65
K: 2.0 - 28 (290 - 4060)
A145R2 60

1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
2. Design Standards: None ........... Japanese Standard "JIS"
80 ............... European Design Standard
90 ............... N. American Design Standard

No.80
"A" Series Piston Pumps
Variable / Fixed Double Pumps
Specifications
PISTON
PUMPS
A
Specifications
Shaft Speed
Geometric Operating Pressure Approx. Mass
Range
Displacement MPa (PSI) kg (lbs.)
Model Numbers r/min
cm3/rev
2 1 Flange Foot
(cu.in./rev) Rated Intermittent Max. Min.
Mtg. Mtg.
3 Outboard Pump Refer to the following page 28.8 31.0
A16R1-∗R01∗-∗AAK-32∗ 1800 750
Inboard Pump 15.8 (.964) 16 (2320) 21 (3050) (63.5) (68.4)
3 Outboard Pump Refer to the following page 28.8 31.0
A22R1-∗R01∗-∗AAK-32∗ 1800 750
Inboard Pump 22.2 (1.355) 16 (2320) 16 (2320) (63.5) (68.4)
3 Outboard Pump Refer to the following page 39 43.3
A37R1-∗R01∗-∗AAK-32∗ 1800 750
Inboard Pump 36.9 (2.25) 16 (2320) 21 (3050) (86.0) (95.5)
Outboard Pump Refer to the following page 47 51.3
A56R1-∗R01∗-∗AAK-32∗ 1800 750
Inboard Pump 56.2 (3.43) 16 (2320) 21 (3050) (104) (113)
Outboard Pump Refer to the following page 66 78
A70R1-∗R01∗-∗AA-60∗
3
1800 750
Inboard Pump 70.0 (4.27) 25 (3630) 28 (4060) (146) (172)
Outboard Pump Refer to the following page 82 105
A90R1-∗R01∗-∗AA-60∗
3
1800 750
Inboard Pump 91.0 (5.55) 25 (3630) 28 (4060) (181) (232)
Outboard Pump Refer to the following page 102 129
A145R1-∗R01∗-∗AA-60∗
3
1800 750
Inboard Pump 145 (8.85) 25 (3630) 28 (4060) (225) (284)
Outboard Pump Refer to the following page 72.5 84.5
A70R2-∗R01∗-∗AA-60∗
3
1800 600
Inboard Pump 70.0 (4.27) 25 (3630) 28 (4060) (160) (186)
Outboard Pump Refer to the following page 91.5 112
A90R2-∗R01∗-∗AA-60∗
3
1800 600
Inboard Pump 91.0 (5.55) 25 (3630) 28 (4060) (202) (247)
Outboard Pump Refer to the following page 112 137
A145R2-∗R01∗-∗AA-60∗
3
1800 600
Inboard Pump 145 (8.85) 25 (3630) 28 (4060) (247) (302)

1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.
2. Care should be taken in cases of use at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used
as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under 6 seconds
simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory
or Yuken sales representative for further information.

One Cycle Time

1/5 of One Cycle


Max. 6s
Pressure

21 MPa (3050 PSI)


[28 MPa (4060 PSI)] ∗
1

Max.
Output Flow

0
20 MPa (2900 PSI)
[27 MPa (3920 PSI)] ∗
1

∗1. Applicable only for A70R1/R2, A90R1/R2, A145R1/R2.

3. The maximum input power of except "A56R1" pump must be restricted, because of the shaft strength.
Refer to the following page.

No.81
"A" Series Piston Pumps
Variable / Fixed Double PISTON
Allowable Input Power / Instructions PUMPS
Allowable Input Power
With the pumps listed in the table below, there is a limit to the sum of the input power of the inboard and outboard
pumps because of shaft strength.
If both pumps are used for boosting at once, referring to the calculation formulas below, check that the displacements
and discharge pressures of both pumps are within the allowable ranges.

Q1 × P1 + Q2 × P2 <
= LM Q1 × P1 + Q2 × P2 <
= LP
3
Q1 : Displacement (cm /rev) Q1 : Displacement (cu.in/rev)
Outboard Pump Outboard Pump
P1 : Discharge Pressure (MPa) P1 : Discharge Pressure (PSI)
Q2 : Displacement (cm3/rev) Q2 : Displacement (cu.in/rev)
Inboard Pump Inboard Pump
P2 : Discharge Pressure (MPa) P2 : Discharge Pressure (PSI)
LM : See the table below L P : See the table below

Model Numbers LM LP
A16R1/A22R1 523 4627
A37R1 900 7963
A70R1/A70R2 2408 21305
A90R1/A90R2 4348 38470
A145R1/A145R2 4739 41930

Geometric Displacement and Max. Pressure of Instructions


Outboard Pump Suction Pressure of Outboard Pump
Geometric Max Pres. MPa (PSI) Permissible suction pressure at inlet port of the outboard pump (PV2R)
Displacement is the range between -20 kPa and +30 kPa (5.9 in. Hg vacuum and
Model Numbers Anti-Wear R&O
cm3/rev +4.3 PSIG).
(cu.in./rev) Type Type
A∗R1-∗R01∗-6 5.8 (.354) 21 1
A∗R1-∗R01∗-8 8.0 (.488) (3050) Suction Piping of Outboard Pump
A∗R1-∗R01∗-10
When the operating speed is less than 1200 r/min, the suction port of
9.4 (.574)
the outboard pump (PV2R) should be facing upwards to facilitate oil
A∗R1-∗R01∗-12 12.2 (.744) 16 suction when starting.
21
A∗R1-∗R01∗-14 13.7 (.836) (2320)
(3050)
A∗R1-∗R01∗-17 16.6 (1.013) When Starting the pump at low speed
A∗R1-∗R01∗-19
maximum viscosity is restricted. Refer to the table below.
18.6 (1.135)
A∗R1-∗R01∗-23 22.7 (1.385) 17.5 (2540)
A∗R1-∗R01∗-25 25.3 (1.544) 15 (2180) 15 (2180) Model
Start-up Speed Max. Viscosity
r/min mm2/s (SSU)
A∗R1-∗R01∗-31 31.0 (1.892) 12 (1740) 12 (1740)
A∗R2-∗R01∗-26
750 100 (465)
26.6 (1.623) A∗R1
21
A∗R2-∗R01∗-33
950 200 (930)
33.3 (2.03)
(3050)
A∗R2-∗R01∗-41
600 100 (465)
41.3 (2.52) A∗R2
14
A∗R2-∗R01∗-47
950 200 (930)
47.2 (2.88) 20 (2900)
(2030)
A∗R2-∗R01∗-53 52.5 (3.20) 18 (2610)
A∗R2-∗R01∗-59 58.2 (3.55) 16 (2320)
A∗R2-∗R01∗-65 64.7 (3.95) 14 (2030)
1. Whn pump is operated pressure more than 16 MPa (2320 PSI), shaft
speed should be more than 1450 r/min.

No.82
"A" Series Piston Pumps
Variable / Fixed Double PISTON
PUMPS
A
Performance Characteristics / Pipe Flange Kits

Performance Characteristics
Performance characteristics of inboard pump refer to relevant page for performance characteristics of "A" series single
pumps excluding noise level characteristics.
Performance characteristics of outboard pump refer to "PV2R" series vane pump catalogue (catalogue No. Pub. EC-0118).
Performance Characteristics
Model
Inboard Pump Outboard Pump
A16R1 Same as Single Pump "A16", Refer to Page 10
A22R1 Same as Single Pump "A22", Refer to Page 11
A37R1 Same as Single Pump "A37", Refer to Page 12
A56R1 Same as Single Pump "A56", Refer to Page 13 Same as Vane Type Single Pump "PV2R1". Refer to the
Catalogue No. Pub.EC-0118.
A70R1 Same as Single Pump "A70", Refer to Page 14
A90R1 Same as Single Pump "A90", Refer to Page 15
A145R1 Same as Single Pump "A145", Refer to Page 16
A70R2 Same as Single Pump "A70", Refer to Page 14
Same as Vane Type Single Pump "PV2R2". Refer to the
A90R2 Same as Single Pump "A90", Refer to Page 15
Catalogue No. Pub.EC-0118.
A145R2 Same as Single Pump "A145", Refer to Page 16

Pipe Flange Kits


Pipe flange kits are available. When ordering, specify the kit number from the table below.
For Inboard Pump ("A" Pump)
Pipe Flange Kit Numbers

Pump Threaded Connection Socket Welding Butt Welding


Model Name of Port Japanese Japanese
Numbers Japanese European N. Ameraican Std. "JIS" & N. Ameraican Std. "JIS" & N. Ameraican
Std. "JIS" Design Std. Design Std. European Design Std. European Design Std.
Design Std. Design Std.
A16R1 Suction F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090
A22R1 Discharge F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090
A37R1 Suction F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
A56R1 Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090
Suction F5-12-A-10 F5-12-A-1080 F5-12-A-1090 F5-12-B-10 F5-12-B-1090 F5-12-C-10 F5-12-C-1090
A70R1
Discharge F5-08-A-10 F5-08-A-1080 F5-08-A-1090 F5-08-B-10 F5-08-B-1090 F5-08-C-10 F5-08-C-1090
A90R1 Suction F5-16-A-10 F5-16-A-1080 F5-16-A-1090 F5-16-B-10 F5-16-B-1090 F5-16-C-10 F5-16-C-1090
A145R1 Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090

For Outboard Pump (PV2R Pump)


Pipe Flange Kit Numbers

Pump Threaded Connection Socket Welding Butt Welding


Model Name of Port Japanese Japanese
Numbers Japanese European N. Ameraican Std. "JIS" & N. Ameraican Std. "JIS" & N. Ameraican
Std. "JIS" Design Std. Design Std. European Design Std. European Design Std.
Design Std. Design Std.
A16R1
A22R1 Suction F5-08-A-10 F5-08-A-1080 F5-08-A-1090 F5-08-B-10 F5-08-B-1090 F5-08-C-10 F5-08-C-1090
A37R1
A56R1
A70R1
A90R1 Discharge F5-04-A-10 F5-04-A-1080 F5-04-A-1090 F5-04-B-10 F5-04-B-1090 F5-04-C-10 F5-04-C-1090
A145R1

A70R2 Suction F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090


A90R2
A145R2 Discharge F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090

In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of the
flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used.
Details of the pipe flange kits are given in the Catalogue No. Pub. EC-3001.

No.83
"A" Series Piston Pumps
A16R1 / A22R1-∗R01∗-∗AAK PISTON
Installation Drawing
PUMPS

Flange Mtg. : A16R1-FR01∗-∗AAK-32/3280/3290


A22R1-FR01∗-∗AAK-32/3280/3290
363.5 44.5(1.75)
(14.31)
310.5 6.5
(12.22) (.26)
254.5 1
(10.02) Filling Port
59 [22(.87) Hex. Head Plug Furnished]
Y (2.32)
Drain Port
26.5
"C" Thd.
(1.04)
(1.874)
47.6

X 4.79(.1886)
25 4.76(.1874)
(1.91) (4.29)

(3.78)
109

96
(.98)
(2.44)

(2.28)
62

58
(7.36)

12(.47)
187

(.71)
18
48.5

19.02(.7488) Dia.

82.50(3.248) Dia.
R12
95(3.74) Dia.
19.05(.7500)

(R.47)

82.55(3.250)
21.24(.836)
21.08(.830) 106
Outboard Pump 22.2 12
(.874) (.47) (4.17)
150.5 130
"D" Thd. 17(.67) Deep (5.93) (5.12)
4 Places (Both Sides) 74 74
Discharge Port 19 (.75) Dia. Inboard Pump
Rear Side (2.91) (2.91)
Suction Port 19 (.75) Dia. Surface of Surface of
188
Discharge Port Suction Port
(7.40)
Suction Port Discharge Port
28(1.10) Dia. 15 (.59) Dia.

16 16
(.63) (.63)
(2.063)

(1.500)

Flow Adj. Screw Pressure Adj. Screw


52.4

38.1

17(.67) Hex. 17(.67) Hex.

DEC. INC.
"D" Thd. 17(.67) Deep "E" Thd. "F" Deep
4 Places 17.5 4 Places
26.2 (.689)
(1.031) View Arrow X
View Arrow Y

1. Install the pump so that the "Filling Port" is at the top.


Model Numbers "C" Thd. "D" Thd. "E" Thd. F mm (IN.)
A16R1/A22R1-FR01∗-∗AAK-32 Rc 3/8
M10 M8 14 (.55)
A16R1/A22R1-FR01∗-∗AAK-3280 3/8 BSP.F
A16R1/A22R1-FR01∗-∗AAK-3290 3/8 NPT 3/8-16 UNC 5/16-18 UNC 16 (.63)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg. : A16R1-LR01∗-∗AAK-32/3280/3290
A22R1-LR01∗-∗AAK-32/3280/3290
12(.47) Dia. Through
24(.94) Dia. Spotface
4 Places
(3.15)
(.59)
(.55)
15
3(.12)

14

80

50 56.5 95
(1.969) (2.22) (3.74)
95 27.5 72.5 72.5
(3.74) (1.08) (2.854) (2.854)
180
(7.09)
For other dimensions, refer to "Flange Mtg.".

No.84
"A" Series Piston Pumps
A37R1-∗R01∗-∗AAK PISTON
PUMPS
A
Installation Drawing
Flange Mtg. : A37R1-FR01∗-∗AAK-32/3280/3290
386.5 62
(15.22) (2.44)
333.5 9.5
(13.13) (.37)
277.5
(10.93)
Y 77
(3.03) 1
202
30 Filling Port (7.95)

(2.311)
[22(.87) Hex. Head Plug Furnished]
58.7
(1.18) 174
Drain Port (6.85)
"C" Thd. 7.97(.3138)
40 7.94(.3126)
X
(4.41)

(4.13)
112

(1.57)

105
(2.28)
58
(7.95)
202

(.55)

(.98)
14

25
(1.91)
48.5

101.55(3.998) Dia.
31.70(1.248) Dia.
R14

101.60(4.000)
120(4.72) Dia. (R.55)
31.75(1.250)

35.32(1.391)
35.16(1.384)
30.2 12 146
Outboard Pump (1.189) (.47) (5.75)
178.5 86 86
"D" Thd. "H" Deep (7.03) (3.39) (3.39)
4 Places (Both Sides) Discharge Port 32 (1.26) Dia. Surface of Surface of
Inboard Pump Discharge Port Suction Port
Rear Side
Suction Port 32 (1.26) Dia.

Suction Port Discharge Port


28(1.10) Dia. 15 (.59) Dia.

13 19
Flow Adj. Screw
(2.063)

(1.500)

(.51) (.75)
52.4

38.1

17(.67) Hex. Pressure Adj. Screw


17(.67) Hex.
"E" Thd. 17(.67) Deep DEC. INC.
"F" Thd. "J" Deep
4 Places 17.5 4 Places
26.2 (.689)
(1.031)
View Arrow X

View Arrow Y

1. Install the pump so that the "Filling Port" is at the top.


mm (IN.)
Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd.
H J
A37R1-FR01∗-∗AAK-32 Rc 1/2
M10 M10 M8 19 (.75) 14 (.55)
A37R1-FR01∗-∗AAK- 1/2 BSP.F
3280 1/2 NPT 7/16-14 UNC 3/8-16 UNC 5/16-18 UNC 20 (.79) 16 (.63)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg. : A37R1-LR01∗-∗AAK-32/3280/3290
14(.55) Dia. Through
28(1.10) Dia. Spotface
4 Places
(4.02)
(.59)
(.55)

102
3(.12)

15
14

60 77 120
(2.362)(3.03) (4.72)
115 42 95 95
(4.53) (1.65) (3.740) (3.740)
230
(9.06)
For other dimensions, refer to "Flange Mtg.".

No.85
"A" Series Piston Pumps
A56R1-∗R01∗-∗AAK PISTON
Installation Drawing
PUMPS
Flange Mtg. : A56R1-FR01∗-∗AAK-32/3280/3290
399 62(2.44)
(15.71)
346 9.5
(13.62) (.37)
290
(11.42) 1
Filling Port
50.5(1.99) [22(.87) Hex. Head Plug Furnished]
2 Surface of Drain Port
Y 43.5(1.71) Drain Port
"C" Thd. (Both Sides)

(2.311)
41 49
58.7
(1.61) (1.93)
40
(1.57) 7.97(.3138)
(2.28)

X 7.94(.3126)
58
(1.91) (5.43)
138

(3.54)
90
(9.29)
236

(.55)

(.98)
25
14
48.5

101.55(3.998) Dia.
31.70(1.248) Dia.

101.60(4.000)
31.75(1.250)

35.32(1.391)
35.14(1.383)
R14
Outboard Pump 30.2 12 146 (R.55)
(1.189) (.47) (5.75)
191 120(4.72) Dia. 174
(7.52) (6.85)
"D" Thd. "H" Deep 100 100
Discharge Port 30 (1.18) Dia.
4 Places (Both Sides) Inboard Pump (3.94) (3.94)
Rear Side
Suction Port 35 (1.38) Dia. Surface of Surface of
Discharge Port 232 Suction Port
Suction Port Discharge Port (9.13)
28(1.10) Dia. 15 (.59) Dia.
(1.500)
(2.063)

38.1
52.4

Flow Adj. Screw Pressure Adj. Screw


17(.67) Hex. 17(.67) Hex.
"E" Thd. 17(.67) Deep INC.
"F" Thd. "J" Deep DEC.
4 Places 26.2 17.5 4 Places
(1.031) (.689)
View Arrow X
View Arrow Y
1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of two drain ports of inboard pump at your option. Keep the remaining port plugged. Note that on the European design standard
(3280 Design), only the left side, as viewed from the shaft end, of the drain port is machined.

mm (IN.)
Model Numbers "C" Thd. "D" Thd. "E" Thd. "F" Thd.
H J
A56R1-FR01∗-∗AAK-32 Rc 3/4
M10 M10 M8 19 (.75) 14 (.55)
A56R1-FR01∗-∗AAK- 3/4 BSP.F
3280 3/4 NPT 7/16-14 UNC 3/8-16 UNC 5/16-18 UNC 20 (.79) 16 (.63)

DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg. : A56R1-LR01∗-∗AAK-32/3280/3290

14(.55) Dia. Through


28(1.10) Dia. Spotface
4 Places
(4.02)
(.55)

(.59)
3(.12)

102
14

15

60 77 120
(2.362) (3.03) (4.72)
115 42 95 95
(4.53) (1.65) (3.740) (3.740)
230
(9.06)

For other dimensions, refer to "Flange Mtg.".

No.86
"A" Series Piston Pumps
A70R1 / A70R2-∗R01∗-∗AA PISTON
PUMPS
A
Installation Drawing
Flange Mtg. : A70R1-FR01∗-∗AA-60/6080/6090
A70R2-FR01∗-∗AA-60/6080/6090 DIMENSIONS IN
MILLIMETRES (INCHES)
62
Fully Extended (2.44)
E
19.5(.77) Surface of Surface of
F Discharge Port 95 95 Suction Port
9.5(.37) (3.74) (3.74)
H
Surface of Surface of
65 2
Drain Port 73 73 Drain Port
Drain Port
(2.063) (2.56) (2.87) (2.87)
52.4

X "a" Thd. (Both Sides) 27(1.06) Dia.


40 Spotface 7.97(.3138)
(1.57) (From Rear) 7.94(.3126)

(7.17)
182
4 Places

(.55)
(3.54)

14
90

(4.504)
F

(7.09)
114.4
Y

(.71)

180
18

(4.65)
118
35(1.38) Dia.
31.70(1.248) Dia.

126.95(4.998) Dia.
Inboard Pump Spotface
31.75(1.250)

35.32(1.391)
35.14(1.383)
Discharge Port 16 127.00(5.000) (From Rear)
26.2 (.63) 4 Places 114.4
26 (1.02) Dia.
(1.031) 18 (4.504)
"d" Thd. 17(.67) Deep
4 Places (.71) 134
246.5 (5.28)
(9.70) 181
Outboard Pump (7.126)
211
(8.31)
Eye Bolt
M10
1 Flow Adj. Screw
Filling Port
17(.67) Hex.
(2.752)

DEC.
69.9

[22(.87) Hex. Head Plug Furnished]


Suction Port Pres. Adj. Screw
Suction Port H Discharge Port 38(1.50) Dia. 17(.67) Hex. INC.
"K" Dia. "P" Dia. Z
N
J

View Arrow Z
"f" Thd. "j" Deep
"e" Thd. "h" Deep 4 Places 3
4 Places L Case Drain Port
35.7 "b" Thd. "g" Deep
5 (.20) Hex. Soc. 4 Places
(1.406)
View Arrow X 246.5
(9.70)

View Arrow Y
1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of two drain ports of inboard pump at your option. Keep the remaining port plugged. Note that on the European design standard
(6080 Design), only the left side, as viewed from the shaft end, of the drain ports is machined.
3. Case drain ports are available for use when draining hydraulic fluid from pump casing.
Dimensions mm (Inches)
Model Numbers
C D E F H J K L N P
439.5 386.5 330.5 58 26.2 52.4 28 17.5 38.1 15
A70R1-FR01∗-∗AA-60∗
(17.30) (15.22) (13.01) (2.28) (1.031) (2.063) (1.10) (.689) (1.500) (.59)
468.5 413.5 333.5 70 30.2 58.7 34 22.2 47.6 21
A70R2-FR01∗-∗AA-60∗
(18.44) (16.28) (13.13) (2.76) (1.189) (2.311) (1.34) (.874) (1.874) (.83)

Thread Size mm (Inches)


Model Numbers
a b d e f g h j
A70R1-FR01∗-∗AA-60 Rc 3/4
M12 M10 M10 M8 19 (.75) 14 (.55)
A70R1-FR01∗-∗AA-6080 3/4 BSP.F 17 (.67)
A70R1-FR01∗-∗AA-6090 3/4 NPT 1/2-13 UNC 3/8-16 UNC 3/8-16 UNC 5/16-18 UNC 21 (.83) 16 (.63)
A70R2-FR01∗-∗AA-60 Rc 3/4
M12 M10 M10 M10 19 (.75) 19 (.75)
A70R2-FR01∗-∗AA-6080 3/4 BSP.F 17 (.67)
A70R2-FR01∗-∗AA-6090 3/4 NPT 1/2-13 UNC 3/8-16 UNC 7/16-14 UNC 3/8-16 UNC 21 (.83) 20 (.79)

Foot Mounting Type


The mounting bracket is common to that of single pumps A70. Refer to page 21 for the dimensions of mounting bracket.

No.87
"A" Series Piston Pumps
A90R1 / A90R2-∗R01∗-∗AA PISTON
Installation Drawing
PUMPS
Flange Mtg. : A90R1-FR01∗-∗AA-60/6080/6090 DIMENSIONS IN
A90R2-FR01∗-∗AA-60/6080/6090 MILLIMETRES (INCHES)
95
Fully Extended (3.74)
E Surface of Surface of
23(.91) Discharge Port 105 105 Suction Port
F
(4.13) (4.13)
13(.51)
H Surface of Surface of
Drain Port 2 Drain Port Drain Port
119.5 68 68
"a" Thd. (Both Sides)
(2.311)
(4.70) (2.68) (2.68)
58.7
X
63
(2.48)
9.56

(7.50)
190.5
9.53

(4.45)
113
(.3764)

(6.362)
(.3752)
F

161.6
Y

(5.00)
127
38.05(1.498) Dia.

152.35(5.998) Dia.
42.36(1.668)
42.18(1.661)
38.10(1.500)

152.40(6.000)
22
Outboard Pump 30.2 161.6 R22(87)
(.87)
(1.189) 23 (6.362)
"d" Thd. "h" Deep
4 Places (.91) 21.5(.85) Dia. Through
Discharge Port 270 39(1.54) Dia. Spotface
32 (1.26) Dia. (10.63) (From Rear)
Inboard Pump 4 Places
Case Drain Port 3
5 (.20) Hex. Soc. Eye Bolt
1
M10 Flow Adj. Screw
Filling Port 17(.67) Hex. DEC.
(3.063)
77.8

[27(1.06) Hex. Head Plug Furnished]


Suction Port Pres. Adj. Screw
H 48(1.89) Dia. 17(.67) Hex. INC.
Suction Port Discharge Port
"K" Dia. "P" Dia. Z
N
J

View Arrow Z
"f" Thd. "j" Deep
"e" Thd. "h" Deep 4 Places
4 Places L 42.9
(1.689)
270 "b" Thd. "g" Deep
(10.63) 4 Places
View Arrow X
View Arrow Y

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports of inboard pump at your option. Keep the remaining port plugged. Note that on the European design standard
(6080 Design), only the left side, as viewed from the shaft end, of the drain ports is machined.
3. Case drain ports are available for use when draining hydraulic fluid from pump casing.

Dimensions mm (Inches)
Model Numbers
C D E F H J K L N P
458 405 349 58 26.2 52.4 28 17.5 38.1 15
A90R1-FR01∗-∗AA-60∗
(18.03) (15.94) (13.74) (2.28) (1.031) (2.063) (1.10) (.689) (1.500) (.59)
497 432 352 70 30.2 58.7 34 22.2 47.6 21
A90R2-FR01∗-∗AA-60∗
(19.57) (17.01) (13.86) (2.76) (1.189) (2.311) (1.34) (.874) (1.874) (.83)

Thread Size mm (Inches)


Model Numbers
a b d e f g h j
A90R1-FR01∗-∗AA-60 Rc 3/4
M12 M10 M10 M8 19 (.75) 14 (.55)
A90R1-FR01∗-∗AA-6080 3/4 BSP.F 17 (.67)
A90R1-FR01∗-∗AA-6090 3/4 NPT 1/2-13 UNC 7/16-14 UNC 3/8-16 UNC 5/16-18 UNC 21 (.83) 16 (.63)
A90R2-FR01∗-∗AA-60 Rc 3/4
M12 M10 M10 M10 19 (.75) 19 (.75)
A90R2-FR01∗-∗AA-6080 3/4 BSP.F 17 (.67)
A90R2-FR01∗-∗AA-6090 3/4 NPT 1/2-13 UNC 7/16-14 UNC 7/16-14 UNC 3/8-16 UNC 21 (.83) 20 (.79)

Foot Mounting Type


The mounting bracket is common to that of single pumps A90. Refer to page 22 for the dimensions of mounting bracket.

No.88
"A" Series Piston Pumps
A145R1 / A145R2-∗R01∗-∗AA PISTON
PUMPS
A
Installation Drawing
Flange Mtg. : A145R1-FR01∗-∗AA-60/6080/6090
A145R2-FR01∗-∗AA-60/6080/6090 DIMENSIONS IN
MILLIMETRES (INCHES)
112 143
Fully Extended (4.41) (5.63)
E
Surface of Surface of
23(.91) Discharge Port Suction Port
F 112 112
13(.51) (4.41) (4.41)
H 2
Drain Port Surface of Surface of
89 "a" Thd. (Both Sides) Drain Port 72 72 Drain Port
X
(2.311)

(3.50) (2.83) (2.83)


58.7

70
(2.76)
11.14

(7.81)
198.5
11.11

(4.33)
110
(.4386)

(9.000)
Y

228.6
(.4374)
F

(5.55)
141
152.35(5.998) Dia.
Dia.

152.40(6.000)

Outboard Pump
49.39(1.944)
49.21(1.937)
44.45(1.750)
44.40(1.748)

30.2 24 228.6 R22(R.87)


(1.189) (.94) (9.000)
"d" Thd. "h" Deep
4 Places 26 273
Discharge Port (1.02) (10.75)
32 (1.26) Dia. 299.5 21.5(.85) Dia. Through
(11.79) Inboard Pump 39(1.54) Dia. Spotface
3 (From Rear)
Case Drain Port 4 Places
5 (.20) Hex. Soc.
Eye Bolt
1 M10 Pres. Adj. Screw Flow Adj. Screw
Filling Port 17(.67) Hex. 17(.67) Hex.
INC. DEC.
(3.063)

[27(1.06) Hex. Head Plug Furnished]


77.8

Flow Adj. Screw Pres. Adj. Screw


Suction Port H Discharge Port 17(.67) Hex. 17(.67) Hex.
DEC. INC.
"K" Dia. "P" Dia. Z
N
J

View Arrow Z
"f" Thd. "n" Deep
"e" Thd. "j" Deep 4 Places "b" Thd. "g" Deep
4 Places L 42.9 4 Places
(1.689) Suction Port
299.5 48(1.89) Dia.
(11.79)
View Arrow X
View Arrow Y
1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of two drain ports of inboard pump at your option. Keep the remaining port plugged. Note that on the European design standard
(6080 Design), only the left side, as viewed from the shaft end, of the drain ports is machined.
3. Case drain ports are available for use when draining hydraulic fluid from pump casing.

Dimensions mm (Inches)
Model Numbers
C D E F H J K L N P
491.5 438.5 382.5 58 26.2 52.4 28 17.5 38.1 15
A145R1-FR01∗-∗AA-60∗
(19.35) (17.26) (15.06) (2.28) (1.031) (2.063) (1.10) (.689) (1.500) (.59)
530.5 465.5 385.5 70 30.2 58.7 34 22.2 47.6 21
A145R2-FR01∗-∗AA-60∗
(20.89) (18.33) (15.18) (2.76) (1.189) (2.311) (1.34) (.874) (1.874) (.83)

Thread Size mm (Inches)


Model Numbers
a b d e f g h j n
A145R1-FR01∗-∗AA-60 Rc 3/4
M12 M10 M10 M8 19 (.75) 19 (.75) 14 (.55)
A145R1-FR01∗-∗AA-6080 3/4 BSP.F 17 (.67)
A145R1-FR01∗-∗AA-6090 3/4 NPT 1/2-13 UNC 7/16-14 UNC 3/8-16 UNC 5/16-18 UNC 21 (.83) 20 (.79) 16 (.63)
A145R2-FR01∗-∗AA-60 Rc 3/4
M12 M10 M10 M10 19 (.75) 19 (.75) 19 (.75)
A145R2-FR01∗-∗AA-6080 3/4 BSP.F 17 (.67)
A145R2-FR01∗-∗AA-6090 3/4 NPT 1/2-13 UNC 7/16-14 UNC 7/16-14 UNC 3/8-16 UNC 21 (.83) 20 (.79) 20 (.79)

Foot Mounting Type


The mounting bracket is common to that of single pumps A145. Refer to page 23 for the dimensions of mounting bracket.

No.89
"A" Series Piston Pumps
Variable / Fixed Double Pump PISTON
Spare Parts List
PUMPS
A16R1-∗R01∗-∗AAK-32/3280/3290
A22R1-∗R01∗-∗AAK-32/3280/3290 CAUTION
A37R1-∗R01∗-∗AAK-32/3280/3290 When making replacement of seals bearings or cartridge
A56R1-∗R01∗-∗AAK-32/3280/3290 kits, please do it carefully after reading through the
A70R1/A70R02-∗R01∗-∗AA-60/6080/6090 relevant instructions in the Operator's Manual.
A90R1/A90R02-∗R01∗-∗AA-60/6080/6090
A145R1/A145R02-∗R01∗-∗AA-60/6080/6090

83 82 80 81

Outboard Pump

Inboard Pump

Seals
Seal Kit Numbers Part Numbers
Pump Model Numbers
Complete Kit For Inboard Pump For Outboard Pump (Item 80 O-Ring)
A16R1-∗R01∗-∗AAK-32/3280/3290 KS-A16R1-01-32 KS-A16-01-32
A22R1-∗R01∗-∗AAK-32/3280/3290 KS-A22R1-01-32 KS-A22-01-32
A37R1-∗R01∗-∗AAK-32/3280/3290 KS-A37R1-01-32 KS-A37-01-32
S85(NBR,Hs70)
A56R1-∗R01∗-∗AAK-32/3280/3290 KS-A56R1-01-32 KS-A56-01-32 KS-PV2R1-4010
1Req'd
A70R1-∗R01∗-∗AA-60/6080/6090 KS-A70R1-01-60 KS-A70-01-60
A90R1-∗R01∗-∗AA-60/6080/6090 KS-A90R1-01-60 KS-A90-01-60
A145R1-∗R01∗-∗AA-60/6080/6090 KS-A145R1-01-60 KS-A145-01-60
A70R2-∗R01∗-∗AA-60/6080/6090 KS-A70R2-01-60 KS-A70-01-60
S105(NBR,Hs70)
A90R2-∗R01∗-∗AA-60/6080/6090 KS-A90R2-01-60 KS-A90-01-60 KS-PV2R2-40
1Req'd
A145R2-∗R01∗-∗AA-60/6080/6090 KS-A145R2-01-60 KS-A145-01-60
Notes: 1) When ordering seals, please specify the seal kit number from the table above.
2) Complete seal kit consists of a seal kit for inboard pump, a seal kit for outboard pump and a piece of O-ring for item 80.
3) Seal kit and bearings for inboard pump are same as those for "A" series single pump. For details, please refer to the table below and see the
chart on the page relevant to pump model number concerned.
4) For details of seals and bearing for outboard pump, please see the chart on the following page.

Model Inboard Pump


A16R1 Same as single pump "A16" (Page 25)
A22R1 Same as single pump "A22" (Page 25)
A37R1 Same as single pump "A37" (Page 25)
A56R1 Same as single pump "A56" (Page 25)
A70R1/A70R2 Same as single pump "A70" (Page 26)
A90R1/A90R2 Same as single pump "A90" (Page 26)
A145R1/A145R2 Same as single pump "A145" (Page 27)

No.90
"A" Series Piston Pumps
Variable / Fixed Double Pumps PISTON
PUMPS
A
Spare Parts List
Detail of Outboard Pump

A∗R1 A∗R2
4 2 7 8 9 5 1 6 4 2 7 8 9 12 5
13 14
12 13

3 15

Sales & Bearing


Part Numbers
Item Name of Parts Qty.
A∗R1 A∗R2
5 Bearing 6004 6205 1
6 Oil Seal SB 20428 ISD 30428 1
7 O-Ring SO-NB-G80 SO-NB-G105 1
8 O-Ring SO-NB-G60 SO-NA-G85 1
9 O-Ring SO-NB-G30 SO-NA-P46 1
Note: Item Nos. 8 and 9 (O-rings) are included in the cartridge kit.
When ordering seals as described in the table above, please specify the seal kit number referring to
chart on the previous page.

Cartridge Kits
Model Numbers 4 Cartridge Kit Numbers
A∗R1-∗R01∗-6AAK-32∗/60∗ CPV2R1-6-R-40
A∗R1-∗R01∗-8AAK-32∗/60∗ CPV2R1-8-R-40
A∗R1-∗R01∗-10AAK-32∗/60∗ CPV2R1-10-R-40
A∗R1-∗R01∗-12AAK-32∗/60∗ CPV2R1-12-R-40
A∗R1-∗R01∗-14AAK-32∗/60∗ CPV2R1-14-R-40
A∗R1-∗R01∗-17AAK-32∗/60∗ CPV2R1-17-R-40
A∗R1-∗R01∗-19AAK-32∗/60∗ CPV2R1-19-R-40
A∗R1-∗R01∗-23AAK-32∗/60∗ CPV2R1-23-R-40
A∗R1-∗R01∗-25AAK-32∗/60∗ CPV2R1-25-R-40
A∗R1-∗R01∗-31AAK-32∗/60∗ CPV2R1-31-R-40
A∗R2-∗R01∗-26AA-60∗ CPV2R2-26-R-40
A∗R2-∗R01∗-33AA-60∗ CPV2R2-33-R-40
A∗R2-∗R01∗-41AA-60∗ CPV2R2-41-R-40
A∗R2-∗R01∗-47AA-60∗ CPV2R2-47-R-40
A∗R2-∗R01∗-53AA-60∗ CPV2R2-53-R-40
A∗R2-∗R01∗-59AA-60∗ CPV2R2-59-R-40
A∗R2-∗R01∗-65AA-60∗ CPV2R2-65-R-40

CAUTION
When making replacement of seals, bearings or cartridge
kits, please do it carefully after reading through the
relevant instructions in the Operator's Manual.

No.91
Pub. EC-0106
"AH" SERIES PISTON PUMPS
Variable Displacement-Single Pumps PISTON A
Pressure Compensator Type PUMPS
AH 16 / AH 37 / AH 56
Up to 31 MPa (4500 PSI), 56.2 cm3/rev (3.43 CU.IN./rev)

Pressure Compensator Valve


Spool
Contorl Piston

Drain Port

Pressure Adj. Screw Pivot

Journal
Bearing
Flow Adj. Screw
OUT

IN

Shaft
Port Plate

Cylinder Block
Cradle
Spring Slipper Retainer
Piston Ass'y Spring

Features
Port Plate Cradle Support Bearing
A special shape maintains a high volumetric efficiency Compared with conventional bearings, this bearing has
under high pressure and provides greater durability. strengthened rigidity of the swash plate. Noise level has
much lowered because it is supported by a housing.

"AH16" type performance characteristics "AH16" type noise level characteristics


% N=1800 r/min dB(A) N=1500 r/min
100 75
Efficiency

Volumetric Efficiency
80 Overall Efficiency
70
60
Noise Level

65

HP kW L /min U.S.GPM
40 30 Output Flow 30 8 60 low
Full F
30
Input Power

6
20 20 55
20 4
wer
10 t Po Full Cut-off
10 Inpu 10
2 50
0 5 10 15 20 25 30 MPa
0 0 31
0 0
0 5 10 15 20 25 30
31 MPa
0 1000 2000 3000 4000
4500 PSI
0 1000 2000 3000 4000 Pressure
4500 PSI
Pressure

High Pressure High speed


Max. Operating Pres. 31 MPa (4500 PSI) Max. 3600 r/min (AH 16)