Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 9

Linsn sending card TS802 cascade control large LED display

Posted date: 2013-3-11 Read count:996

Linsn sending card TS802 cascade control large LED display

I. Hardware ready

1, a DVI cable (DVI cable a turn two lines)


2. 2pcs of Linsn sending card TS802
3, a ten-pin cable

II. Hardware connection

1, with a ten-pin cable to two sending card cascade up, as shown in picture 1.
Picture 1. a ten-pin cable to connect the two sending card

2, Each Sending card TS802 has a red button, one sending card a button set to 1, and another sent card keys unchanged, as
shown in picture 2.
Picture 2 button set

3, Insert two sending card into your computer's PCI slot, connected to the graphics card's DVI and two send cards with DVI a turn
two lines, an insertion of the card's DVI port, two were inserted into the two sent the card's DVI port,as shown in picture 3.
Picture 3 to connect two sender DVI interface

III. Software settings

Two 802 sending card cascade up to run 1600 * 1200 pixels, two sending card total have four RJ45 signal output port
respectively the 1U1D2U2D, as shown in Figure 4. The red buttons did not change is RJ45 1U1D, another send card RJ45
respectively 2U2D, as shown in picture 4.
Picture 4 two cards cascaded output

Set operating CON file in accordance with the connection of the screen, with a height of 400 points for each sent card RJ45,
higher than 400 points with another RJ45 port, in order to push up start 1U port, 1U-1D-2U-2D, when the CON document is set
as follows.

Picture 5 set CON file

Network Cable 1 from 1U port into sending cards, shown in Picture 5, in the main cable select No. 1 transmission card U lines
(1U)
Picture 6

Use network Cable 2 connected to the receiver card, shown in Picture 6 on the main cable select send cards D line (1D)
Picture 7

To use network Cable 3 connected to the receiver card: shown in Picture 7, select the main cable send cards, U-line (2U)
Picture8
Using network cable 4 is connected to the receiver card, shown in Picture 8, on the main cable to select the 2nd transmission
card D line (2D)

The specific approach is set according to the on-site connection method, after setting send to the receiving card, and save on the
receive card.