The document provides instructions for operating a single channel loop detector for vehicle detection. It describes how to set the sensitivity in 4 steps using DIP switches and how to set the hold time to either 5 minutes or infinite using another DIP switch. It also explains the functions of the green and red LED lights and how they indicate the status of the detector and loop. The technical specifications include dimensions, operating temperature range, loop specifications, and relay output details.
The document provides instructions for operating a single channel loop detector for vehicle detection. It describes how to set the sensitivity in 4 steps using DIP switches and how to set the hold time to either 5 minutes or infinite using another DIP switch. It also explains the functions of the green and red LED lights and how they indicate the status of the detector and loop. The technical specifications include dimensions, operating temperature range, loop specifications, and relay output details.
The document provides instructions for operating a single channel loop detector for vehicle detection. It describes how to set the sensitivity in 4 steps using DIP switches and how to set the hold time to either 5 minutes or infinite using another DIP switch. It also explains the functions of the green and red LED lights and how they indicate the status of the detector and loop. The technical specifications include dimensions, operating temperature range, loop specifications, and relay output details.
2 Setting options • The detector cannot be used as a security device regarding to
power off close close open
the security instructions of electrical machines. Using in systems 2.1 S e n s i t i v i t y with high danger potential it is necessary to include additional The setting of the sensitivity tells the electronics to a value of In case of a loop failure the detector checks the loop condition protection devices! frequency deviation which a vehicle must produce for setting the cyclically and continues automatically after elimination. output of the detector. The sensitivity can be adjusted in 4 steps with the two DIP-switches ‘s’ on top of the front panel. 3.2 L E D s i g n a l s 5 Technical data The green LED signals that the detector is ready for operation. Via sensitivity step DIP- switch ‘s’ the red LED, the activation of the relays output is announced Dimensions 79x22.5x90 mm (H x W x D without MAGNETIC AUTOMATION CORP. depending on the occupation status of the loop. plug) 1 low (0,64% ∆f/f) 3160 Murrell Rd. Rockledge, FL 32955 Protection class IP 40 2 (0,16% ? f/f) LED LED red Power supply 24V AC/DC ±10% max.1.5W Operation Instruction 3 (0,04% ? f/f) green loop loop condition detector function Operating -20 °C to +70 °C control temperature Single channel loop detector 4 high (0,01% ? f/f) off off power off Storing temperature -20 °C to + 70 °C Humidity max. 95 % not condensing for DIN-rail mounting flashing off calibration or output of frequency 2.2 H o l d t i m e a n d R e s e t Loop inductivity 25-800 µH, recommended 100- MID 1E -800 The hold time can be adjusted with DIP-switch ‘h’. 300uH on off detector ready for operation, free loop At the completion of hold time it will be displayed "free loop" Frequency range 30-130 kHz in 2 steps and the detector calibrates automatically. The hold time starts on on det. ready f or operation, covered loop Sensitivity 0,01 % up to 0,65 % (∆f/f) in 4 steps with the occupation of the loop. 0,02 % up to 1,3 % (∆L/L) off on loop failure Hold time 5 minutes or infinite hold time D I P - s w i t c h ‘ h’ Loop lead length max. 250 m 5 minutes 3.3 O u t p u t o f l o o p f r e q u e n c y Loop resistance max. 20 Ohm (incl. loop lead) Approx. 1 sec. after calibration of the detector the loop infinite frequency will be displayed by pulse signals of the green LED. Relays 250mA / 24V AC/DC (min. 1mA/5V) Firstly the 10kHz position of the frequency value will be presence relay contact N. C. (adjust. operation indicated. For every 10kHz frequency value the green LED flashes pulse relay principle) contact n.o. The detector will do an automatic calibration of the loop once. After a break of 1sec the 1kHz position is displayed in the Signal duration > 200 ms frequency after turning-on the power supply. In case of short same manner. If there is value of '0' in the 1kHz position there will Cycle time 40 ms (reaction time 80 ms) power cuts <0.1s there is no calibration be displayed 10 flashes. The flashes for 1kHz position are a little A reset with calibration can be affected by changing the hold Connections screw terminals (power supply, bit shorter than for the 10kHz position. time setting. relays) Example for 57kHz loop frequency: binder plug (loop connection) 2.3 O p e r a t i o n p r i n c i p l e o f t h e p r e s e n c e r e l a y CE- standards EN 50082-2, Feb. 1996 tenth values single values The detector has one relay for presence output and another relay EN 50081-1, March 1993 for pulse output each with a potential free contact. The 1sec operation principle of the presence relay can be changed with 5x 10kHz 7x 1kHz the DIP-switch’s’ 6 Connections
operation principle DIP- switch
presence relay ‘r’ 4 Safety information and warnings contact normally closed • The device should only used for the applications described by the manufacturer. contact normally open • Please keep this operation instruction always accessible and Please read these instructions and safety hand it over to every user. information and warnings attentively before initial 2.4 F r e q u e n c y a d j u s t m e n t • Inadmissible modifications to the device, use of repair parts operation of the detector ! The operation frequency of the detector can be adjusted in two and supplementary equipment that are not sold or steps by the 3-pole connection jack in the front panel. The recommended by the manufacturer can cause burning, permissible frequency range is 30kHz to 130kHz. The frequency electric shock and injuries. Therefore the manufacturer has no 1 General depends on the loop inductivity (depending itself on: loop liability and this excludes all demands of warranty. Applications: geometry, number of loop turns and loop lead) and the adjusted • The warranty regulations of the manufacturer are valid in the • barrier controls frequency step. version of the purchase date for that device. There is no liability • door and gate controls for not suitable, wrong manual or automatic adjustments also upper position = high frequency • parking and traffic technology regarding no suitable applications of the device. lower position = low frequency • Repairs may only made by the manufacturer. Features: • All connections, the start-up, maintenance, measurements and 3 Outputs and LED adjustment operations to the detector have to be made from The induction loop detector MID 1E-800 is a system for inductive recognition of vehicles with the following characteristics: 3.1 C o n t a c t m o d e o f t h e r e l a y s electrical specialists who have special know-how in the Note isolated transformer between loop and detector electronics The following table shows the state of the relay contacts prevention of accidents. The information in this instruction c an be changed without notice. • automatic calibration of the system after switching on depending on the detector mode. • For the use of devices that have contact to electrical power, This description replaces all previous issues. The summary of • continuous rebalancing of frequency drifts please pay attention to the valid security instructions and all information in this description was done with all possible • usable for single place parking space supervising prevention orders of fire and accidents. knowledge and by the best conscience. MAGNETIC presence relay • sensitivity independent of the loop inductivity • All operations with the device and its placement have to be AUTOMATION CORP. can’t give guaranty for the correctness of all detector mode pulse relay • presence signal feedback by LED display done in accordance with national and general electrical information. Particularly there is no liability by MAGNETIC • potential free relay contacts for presence and pulse output instruction orders. AUTOMATION CORP. for damages that result from a wrong free loop close open open • pulse output while leaving the loop • The user is responsible for an installation, which has conformity installation of the device. In spite of all efforts to correctness we • signalling of loop frequency by LED covered loop open close open to all technical rules in the country where the device is are very thankful for every poi nt to a mistake in this description. • loop connection plug-in for diagnosis mounted, and also to all regional valid orders. For that the The installation recommendations in this description are based loop gets free close open 200ms pulse dimension of cabling, fuse protection, connection to ground, on optimum conditions. For wrong environment conditions switch off, disconnection, isolation controlling and the MAGNETIC AUTOMATION CORP. doesn’t give a warranty to loop failure open close open protection for overload current have to be regarded in detail. optimum operation of the detector. MAC MID1E op man, 2001-1 02-18-01 cww Copyright 2001 by Magnetic Automation Corp.