Prestressed concrete technology has revolutionized the infrastructure growth in many countries, especially that of the
bridge sector. The bond between prestressed strand and concrete is very important for achieving good structural
performance. However, some of the codal provisions have not given enough consideration to the bond strength of
PTC system in design. This paper presents the results from a preliminary experimental program on the bond strength
of 7-wire strands embedded in M35 and M55 concretes. A pull-out test method was developed and the same was used
to determine the bond strength. The bond behavior and the mechanisms at the strand-concrete interface is also
discussed. Bond strength of 7 wire strand in M55 concrete is found to be about two times more than that in M35
concrete.
Key words: Pretensioned concrete, Pull-out test, Bond strength, Bond-slip, Strand concrete interface
1
Ph. D. Scholar, prabhamohandoss@gmail.com
2
B. Tech. Student, sriram.kasyap7997@gmail.com
3
Assistant Professor, pillai@iitm.ac.in
is the expansion of strand in the transfer zone after average 28-day compressive strength of M35 and M45
releasing the prestress due to Poisson’s effect. The concretes were 41 and 58 MPa, respectively. As
bond between the strand and concrete can also be shown in Figure 2, the length of the concrete prism
influenced by many factors such as compressive was 500 mm. The length of bond breaker placed
strength of concrete, type/diameter/surface condition inside the specimen was 50 mm. Therefore, the actual
of the strand, amount of prestress applied etc. [3] embedment length (le) of the strand is 450 mm.
2.2.2 Instrumentations
2D Graph 1
14
(b) M55-12.7mm-0.1fpu S3
12
Bond stress (MPa)
10 S1
S2
8
4 S4
Figure: 6 Bond strength of PTC specimens as a
2
function of compressive strength of concrete
0
0 5 10 15 20 25 30 35 40
Table: 1 Bond stress values of 12.7 strands
Live end slip (mm)
Specimen Grade f'c 2.5 max Slip
Figure: 5 Bond behavior in (a) M35 grade No. of (MPa) (MPa) (MPa) at max
and (b) M55 grade concretes concrete (MPa)