Professional Documents
Culture Documents
4-1. ViO50 - 55-6B Electric Functions
4-1. ViO50 - 55-6B Electric Functions
4-1. ViO50 - 55-6B Electric Functions
Service Training
- Electric functions
1. Eco Mode
2. Auto Deceleration
3. Engine Stop Switch
4. Preheat Control
5. Cabin room lump
6. Notes of battery voltage
Engine
control dial
• If the control levers and pedals are in the neutral position for 4 seconds or more,
the engine speed is automatically reduced to low idle to reduce fuel consumption
and noise.
• Operating any of the control levers or pedals automatically returns the engine
speed to the previous speed.
Forward
Control valve
Travel oil pressure detection switch:
This switch senses pilot pressure of
travel.
Connect to
Engine ECU
© YANMAR Co., Ltd. 2022年7月11日 Page5
3. Engine Stop Switch
• Engine Stop Switch: Standard Same mechanism as for
ViO30/35-6
• If the starter switch key cannot be operated due to failure, damage or other
causes, the engine can be stopped by pressing the engine stop switch provided on
the side of the machine body.
“Normal” “Stop”
position position
At low temperatures:
3 key positions ON Relationship between coolant
(OFF - ON - START) ⇒ Automatically temperature and preheating time
turned on and off
Three positions
1. “ON” position : Lamp is illuminated.
2. “OFF” position : Lamp is not illuminated.
3. “Intermediate” position:
(1) The room lamp automatically turns on when door is opened (It automatically turns off
after 15 seconds).
(2) The room lamp automatically turns off when door is closed.
© YANMAR Co., Ltd. 2022年7月11日 Page8
5. Cabin room lamp
Lamp switch:
This switch for cabin room lump senses if door is opened or not.
Note: The machine must not be left with the door open for a prolonged
period of time (2 months or more) because “dark current” is flowed.
Battery
Voltage
Key “start”
6.0 VDC
Time
※Engine cannot start
Check Engine stop switch →(No)Battery replace, Jump start
→(No) Go to normal trouble shooting
© YANMAR Co., Ltd. 2022年7月11日 Page10
Thank you for your attention.