SITE LAYOUT

Key Plan

NOTES:
30,000 12,498 13,685 3,818
1. ALL DIMENSIONS AND LEVEL ARE IN MILLIMETERS
UNLESS OTHERWISE NOTIFIED.
2. ALL DIMENSIONS MUST BE CHECKED ON SITE
PRIOR TO CONSTRUCTION.

3,230
3. GATE LEVEL REF. SITE SETTING OUT PLAN.
Septic tank Chamber
4. ANY DISCREPANCY TO BE REPORTED IMMEDIATELY
TO THE ARCHITECT.
Chamber

150
5. CONTRACTOR IS RESPONSIBLE FOR
COORDINATION OF SERVICES IN VOIDS.

8,000
1,470
6. THIS DRAWING MUST BE READ IN CONJUNCTION
WITH THE ARCHITECTURAL, STRUCTURAL AND ALL

150
OTHER SERVICE DRAWING.

Rear Verandah

3,000
4,820 136 12,289
Revisions
Supply Circulation

No. Date Description

Kitchen

Guest
Room
Dining
Wc/Sh

Sunken
Lounge

Lobby
Wc/Sh
32,960

Client:

Room
Study
Mr. Kenneth Temu
Front Verandah

40,816
Consultants:
11,222

Job title:
PROPOSED PIG BARN TO BE BUILT
AT MADALE ON PLOT NO....,
BLOCK ..., DAR ES SALAAM
29,931

38,785 Drawing title


Site layout

Scale Design by: Ombeni M.


Date Drawn by: Ombeni M.
Job No. Drawing No.:

.............................. Rev. No:


GROUND FLOOR PLAN

A B C D

13,535 Key Plan

NOTES:
5,040 5,000 3,495 1. ALL DIMENSIONS AND LEVEL ARE IN MILLIMETERS
UNLESS OTHERWISE NOTIFIED.
2. ALL DIMENSIONS MUST BE CHECKED ON SITE

150 4,850 230 4,770 230 3,304 150 PRIOR TO CONSTRUCTION.


3. GATE LEVEL REF. SITE SETTING OUT PLAN.
4. ANY DISCREPANCY TO BE REPORTED IMMEDIATELY
TO THE ARCHITECT.
5. CONTRACTOR IS RESPONSIBLE FOR
1 1 COORDINATION OF SERVICES IN VOIDS.
1,050

1,050
150

150
6. THIS DRAWING MUST BE READ IN CONJUNCTION
WITH THE ARCHITECTURAL, STRUCTURAL AND ALL
OTHER SERVICE DRAWING.

46 46 Revisions
46 549 549 549 46
No. Date Description
46
1,725

1,725
1,887

1,730
756

756
Client:
31

Sow access circulation Mr. Kenneth Temu


600 1,020

600 1,020
8,000

8,000
2,077

Consultants:
7,850

7,850
Sow access circulation
1,725

1,725
1,276

1,276
Supply Circulation
Farrowing cages

2 2
150

150
1,230 2,730 2,270 2,730 2,070 1,725 930

150 4,850 230 4,770 230 3,305 150 Job title:


PROPOSED PIG BARN TO BE BUILT
AT MADALE ON PLOT NO....,
5,040 5,000 3,495 BLOCK ..., DAR ES SALAAM

13,535 Drawing title


Ground floor plan
A B C D
Scale Design by: Ombeni M.

Architectural barn plan Date Drawn by: Ombeni M.


Job No. Drawing No.:
Scale 1:50 .............................. Rev. No:
SANITARY PIPING LAYOUT

1 1
Pressure pipe Ø 50mm
Pressure pipe Ø 50mm
Key Plan

NOTES:

Sloping floor
1. ALL DIMENSIONS AND LEVEL ARE IN MILLIMETERS
UNLESS OTHERWISE NOTIFIED.
2. ALL DIMENSIONS MUST BE CHECKED ON SITE
PRIOR TO CONSTRUCTION.
3. GATE LEVEL REF. SITE SETTING OUT PLAN.
4. ANY DISCREPANCY TO BE REPORTED IMMEDIATELY
TO THE ARCHITECT.
5. CONTRACTOR IS RESPONSIBLE FOR
COORDINATION OF SERVICES IN VOIDS.
Sanitary Pipe Ø 100 1% slope 6. THIS DRAWING MUST BE READ IN CONJUNCTION
WITH THE ARCHITECTURAL, STRUCTURAL AND ALL

Chamber OTHER SERVICE DRAWING.

To septic tank
Revisions
No. Date Description
Drainage channel 1% Percent

Drainage channel 1% Percent


See detail 1

Client:

Mr. Kenneth Temu

Consultants:
Sloping floor

From elevated tank

Pressure pipe Ø 50mm

2 2

A B C D

SANITARY PIPING LAYOUT


SCALE 1:50

568

568
Pregnancy cage

1,219
Job title:
PROPOSED PIG BARN TO BE BUILT
AT MADALE ON PLOT NO....,
3,541

BLOCK ..., DAR ES SALAAM

2,322
Drawing title

Plastic grid/grating Sanitary piping layout

Detail 1 Sloping floor Scale Design by: Ombeni M.

Drainage channel Date Drawn by: Ombeni M.

1:20 Drainage channel 1% slope. Job No. Drawing No.:

.............................. Rev. No:


ROOF PLAN

Key Plan

NOTES:
1. ALL DIMENSIONS AND LEVEL ARE IN MILLIMETERS
UNLESS OTHERWISE NOTIFIED.
2. ALL DIMENSIONS MUST BE CHECKED ON SITE
1 1 PRIOR TO CONSTRUCTION.
3. GATE LEVEL REF. SITE SETTING OUT PLAN.
4. ANY DISCREPANCY TO BE REPORTED IMMEDIATELY
TO THE ARCHITECT.
5. CONTRACTOR IS RESPONSIBLE FOR
COORDINATION OF SERVICES IN VOIDS.
6. THIS DRAWING MUST BE READ IN CONJUNCTION
WITH THE ARCHITECTURAL, STRUCTURAL AND ALL
OTHER SERVICE DRAWING.

Revisions
No. Date Description

Client:
8,000

8,000
Mr. Kenneth Temu

Consultants:

2 2
600

600
600 13,685 600
Job title:
PROPOSED PIG BARN TO BE BUILT
AT MADALE ON PLOT NO....,
BLOCK ..., DAR ES SALAAM
A B C D
Drawing title

ROOF PLAN Roof plan

Scale Design by: Ombeni M.


Date Drawn by: Ombeni M.
Job No. Drawing No.:

.............................. Rev. No:


ROOF PLAN

Key Plan

NOTES:
1. ALL DIMENSIONS AND LEVEL ARE IN MILLIMETERS
UNLESS OTHERWISE NOTIFIED.
2. ALL DIMENSIONS MUST BE CHECKED ON SITE

1 2
PRIOR TO CONSTRUCTION.
3. GATE LEVEL REF. SITE SETTING OUT PLAN.
4. ANY DISCREPANCY TO BE REPORTED IMMEDIATELY
TO THE ARCHITECT.
5. CONTRACTOR IS RESPONSIBLE FOR

Existing fence wall COORDINATION OF SERVICES IN VOIDS.


6. THIS DRAWING MUST BE READ IN CONJUNCTION
WITH THE ARCHITECTURAL, STRUCTURAL AND ALL
OTHER SERVICE DRAWING.

Corrugated Iron sheets Revisions

50
No. Date Description

1,250
195

Client:
150

150
Mr. Kenneth Temu

4,055
Lighting lamp

2,500
1,270

Consultants:
farrowing cage
3,170

2,155
pregnancy cage
Block wall plinth
Supply
885

circulation
450

450
Concrete slab

Drainage channel

8,000
Job title:
PROPOSED PIG BARN TO BE BUILT
AT MADALE ON PLOT NO....,
BLOCK ..., DAR ES SALAAM

Cross Section Drawing title


Roof plan

Scale 1:50 Scale


Date
Design by: Ombeni M.

Drawn by: Ombeni M.


Job No. Drawing No.:

.............................. Rev. No: