12
Alignment
Set up the test equipment as shown below for trans- The alignment tool outline
ceiver alignment, and apply 7.5V DC power to the trans- Installation of the Alignment tool
ceiver. The “alignment mode” is a software-based protocol,
accessed by an “Alignment Mode” command from the
50-ohm computer while switching the transceiver on.It is oper-
Dummy Load ated by the alignment tool automatically. During use of
RF Signal the alignment mode, normal operation is suspended. The
Generator
alignment tool program provides all needed operation ca-
Inline Wattmeter
pability.
The alignment tool consists of an executable file
RF Sampling “CE44.exe” and an accmpanying configuration file
Deviation Meter Transceiver
Coupler “CE44.cfg” which should be loaded per standard DOS
CT-42A connection MIC/EAR procedures. Create a suitable directory, then copy these
Cable
Frequency foles from the distribution diskette into the new directory.
Power Supply
Counter PC 7.5V DC For example, if copying the file from Drive A, use the
COM port following DOS command sequence:
c:\ mkdir align [enter]
c:\ cd align [enter]
The transceiver must be programmed for use in the c:\ align\ copy a:ce44.*
intended system before alignment is attempted. The RF
parameters are loaded from the file during the alignment No further installation steps are required. If you wish
process. to utilize a different name for the alignment directory, it
In order to facilitate alignment over the complete op- will not matter to the executable file.
erating rang of the equipment, it is recommended that the Booting the Alignment Tool
channel data in the transceiver be preset as per the chart Change to the “align” directory (or the directory name
below. you utilized in the previous section). Now type on the
command line: ce44 [ENTER] to boot the alignment tool.
Frequency (MHz) The introductory screen will appear, and you may press
Channels any key to enter the main screen.
Ver. A Ver. C
Low Band Edge 134.000 148.000 Entering Alignment Mode
(Channel 1) (Low POWER) (Low POWER) To enter the alignment mode, turn the transceiver off,
Band Center 147.000 161.000 Select “Radio” then “Adjust” parameter. Now, turn the
(Channel 2) (High POWER) (High POWER)
transceiver back on. When the command has been suc-
cessful, a message on the computer screen will confirm
High Band Edge 160.000 174.000
that the transceiver is now in the “Alignment” mode.
(Channel 3) (High POWER) (High POWER)
Alignment Sequence
Although the data displayed on the computer's screen
Tone-Frequency (Hz) / DCS-code
during alignment is temporary data, it is important you
Channel Ver. A Ver. C follow the basic alignment sequence precisely, so that the
CTCSS DCS CTCSS DCS displayed data and the data loaded into the transceiver are
Low Band Edge identical.
– – – – Basic Alignment Sequence
(Channel 1)
Band Center 1. Enter the alignment mode
151.4 – 151.4 – 2. Upload data from transceiver
(Channel 2)
3. Align data
High Band Edge 4. Download data to transceiver
– 627 – 627
(Channel 3)
13
Alignment
PLL VCV (Varactor Control Voltage) MIC Sensitivity
r Connect the DC voltmeter between TP3 on the Main r Set the transceiver to CH 2 (band center).
Unit and ground. r Inject a 1 kHz tone at –37 dBm to the MIC jack.
r Set the transceiver to CH 3 (high band edge), and ad-
just L1004 on the Main Unit for 3.7~3.8 V on the DC
CLONE GND
voltmeter.
r Set the transceiver to CH 1 (low band edge), and con-
SP
firm the low-end VCV is 0.9 ~ 1.5 V while transmit-
ting, and also while receiving.
IN
Low Power
r Set the transceiver to CH 1 (Low band edge).
r Open the “Adjust” window on the CE44 program, then
select the “RF Power (Low)” parameter.
r Press the [ENTER] key to enable programming of this
parameter; use the [¡] or [¢] arrow keys so that the
power meter reading is 1.0 W (± 0.1 W) (for “RF Power
Low”). Confirm that the current consumption is 1.0 A
or lower.
r Press the [ENTER] key to lock in the new data.
TP3 L1004
14
Alignment
MAX Deviation RF Frequency
r Set the transceiver to CH 2 (band center). r Set the transceiver to CH 2 (band center).
r Inject a 1 kHz tone at –17 dBm to the MIC jack. r Open the “Adjust” window on CE44, then select the
r Open the “Adjust” window on CE44, then select the “RF Frequency” parameter.
“MAX Deviation” parameter. r Press the [ENTER] key to enable programming of this
r Press the [ENTER] key to enable programming of this parameter; use the [¡] or [¢] arrow keys so that the
parameter; use the [¡] or [¢] arrow keys so that the frequency counter displays the band center frequency
deviation meter reading is ±4.2 kHz (±0.1 kHz) (for (±100 Hz) for the version being aligned.
25 kHz steps) or ±2.1 kHz (±0.1 kHz) (for 12.5 kHz r Press the [ENTER] key to lock in the new data.
steps) deviation.
r Press the [ENTER] key to lock in the new data. Sensitivity
r Set the transceiver to CH 3 (high band edge).
CTCSS Deviation r Tune the RF signal generator to the same frequency as
r Set the transceiver to CH 2 (band center). the transceiver’s, then set the generator output level to
r Open the “Adjust” window on CE44, then select the 40 dBµ with ±3.0 kHz deviation @ 1 kHz tone modu-
“CTCSS Deviation” parameter. lation.
r Press the [ENTER] key to enable programming of this r Open the “Adjust” window on CE44, then select the
parameter; use the [¡] or [¢] arrow keys so that the “RX Tune” parameter.
deviation meter reading is ±0.8 kHz (±0.1 kHz) (for r Press the [ENTER] key to enable programming of this
25 kHz steps) or ±0.5 kHz (±0.1 kHz) (for 12.5 kHz parameter. Use the [¡] or [¢] arrow keys to tune for
steps) deviation. best sensitivity; ultimately, the radio should be aligned
r Press the [ENTER] key to lock in the new data. so that the RF signal generator output level is –6 dBµ
EMF (0.25 µV) or less for 12 dB SINAD.
DCS Deviation r Press the [ENTER] key to lock in the new data.
r Set the transceiver to CH 3 (high band edge).
r Open the “Adjust” window on CE44, then select the
“DCS Deviation” parameter.
r Press the [ENTER] key to enable programming of this
parameter; use the [¡] or [¢] arrow keys so that the
deviation meter reading is ±0.75 kHz (±0.1 kHz) (for
25 kHz steps) or ±0.35 kHz (±0.1 kHz) (for 12.5 kHz
steps) deviation.
r Press the [ENTER] key to lock in the new data.
15