01 SPECIFICATION, CONCRTE COVER AND LOADING ANALYSIS FOR SLABb

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 11

GROUP INFORMATION

NAME
MUHAMMAD IZZUDDIN BIN MOHD SHAIDI BAKHARI

MATRIC NO. 06DKA19F1134

CLASS DKA5C

NAME
MUHAMMAD HAZIQ HAIKAL BIN YAZID

MATRIC NO. 06DKA19F1097

CLASS DKA5C

NAME
MUHAMMAD RIDHWAN BIN ISMAIL

MATRIC NO. 06DKA19F1117

CLASS DKA5C

NAME
MUHAMMAD ABDUL BASIT BIN ABDUL SAMAD

MATRIC NO. 06DKA19F

CLASS DKA5C
GENERAL DESIGN INFORMATION

PROJECT

CLIENT

ARCHITECT

CONSULTANT Civil & Structural Engineers

Mechanical & Electrical Engineers

Quantity Surveyor

CONTRACTOR
DESIGN SPECIFICATION

DESIGN WORKING LIFE (Table 2.1 EN 1992)

50 years

EXPOSURE CLASS (Table 4.1 EN 1992)

XC1 = Dry or permanently wet

FIRE RESISTANCE (UBBL)

1 hour (Institunal, Max. height < 28m, Floor area > 2000 m 2) = R60

MATERIALS (EN 1992 Sec. 3.1, Sec. 3.2)

Characteristic srength of concrete, fck = 25 N/mm2


Characteristic srength of main reinforcement, fyk = 500 N/mm2
Characteristic srength of shear reinforcement, fyk = 500 N/mm2
Assumed diameter bar, Øbar = 20 mm
Assumed diameter link, Ølink = 8 mm
CONCRETE COVER FOR SLAB

Design working life = 50 years


Exposure class = XC1
Bar Size
Min. conc. Cover regard to bond (seperated), Cmin,b = 20 mm ~Refer Table 4.2~

###
Min. conc. Cover regard to durability, Cmin,dur = 15 mm ~Refer Table 4.4N~

###
Min. required axis distance for REI60 fire resistance, asd = 20 ~please key-in the asd :
Use Value at Table
5.8~

Min. concrete cover regard to fire, Cmin, fire = mm ###


###
Allowance in design for deviation, ∆C dev = 10 mm ###
###
Nominal cover , Cnom = 25 mm XS3

CONCRETE COVER FOR BEAM

Design working life = 50 years


Exposure class = XC1
Bar Size
Min. conc. Cover regard to bond (seperated), Cmin,b = 20 mm ~Refer Table 4.2~

###
Min. conc. Cover regard to durability, Cmin,dur = 15 mm ~Refer Table 4.4N~

###
Min. required axis distance for R60 fire resistance, asd = 30 + 10 ~please key-in the asd :
Use Value at Table
= 40 mm 5.5~

Min. concrete cover regard to fire, Cmin, fire = 22 mm ###


###
Allowance in design for deviation, ∆C dev = 10 mm ###
###
Nominal cover , Cnom = 32 mm XS3
LOADING ON SLAB

Slab Properties:
Slab Thickness = 150 mm
R/C density = 25 kN/m3

GROUND FLOOR (GB)

Dining Area
Slab selfweight = 0.15 x 1.000 x 25 = 3.75 kN/m2
Finishes:
Tiles and bedding = 1.00 kN/m2
Rendering, screed (50 mm thk.) = 1.15 kN/m2
Others dead load:
~choose~ = kN/m2
~choose~ = kN/m2

Total Dead Load, Gk = kN/m2


Total Imposed Load, Qk = 2.30 kN/m2

Design action, n = kN/m2

SLAB CLASSIFICTION

Slab size
Long span, ly = m ~please key-in the slab
size~
Short span,lx = m
ly/lx = #DIV/0! → #DIV/0!

SLAB ANALYSIS

For One Way Slab

Bending Moment, M = kNm


Shear Force, V = kN
LOADING ON SLAB

Slab Properties:
Slab Thickness = 125 mm
R/C density = 25 kN/m3

FIRST FLOOR (FF)

Wet Kitchen
Slab selfweight = = kN/m2
Finishes:
Ceramic floor tiles = 1.015 kN/m2
Rendering, screed (50 mm thk.) = 1.150 kN/m2
Others dead load:
Services = 0.10 kN/m2
Suspended ceilling = 0.15 kN/m2

Total Dead Load, Gk = kN/m2


Total Imposed Load, Qk = 3.00 kN/m2

Design action, n = kN/m2

SLAB CLASSIFICTION

Slab size
Long span, ly = 2.000 m ~please key-in the slab
size~
Short span,lx = 1.500 m
ly/lx = 1.3 → Two way slab

SLAB ANALYSIS

For Two Way Slab


Moment, M
αsx = 0.093
~select the right value
αsy = 0.055 refer Table 3.13~

Short Span, Msx = kNm


Long Span, Msy = kNm

Shear Force, V = kN
ACTIONS

Permanent actions Variable actions


Unit weight of reinforced concrete = 25.000 kN/m3 Imposed loads:
Brickwall : 125 mm = 2.600 kN/m2 ~choose~ = 0.00
Floor finishes: Balcony = 1.50 kN/m2
~choose~ = 0.000 Utility Room = 1.75 kN/m2
Carpet = 0.050 kN/m2 Bedroom = 2.00 kN/m2
Terrazzo (16 mm thk.) = 0.500 kN/m2 Dry Kitchen = 2.00 kN/m2
Clay floor tiles = 0.650 kN/m2 Family Area = 2.00 kN/m2
Tiles and bedding = 1.000 kN/m2 Toilet = 2.00 kN/m2
Ceramic floor tiles = 1.015 kN/m2 Dining Area = 2.30 kN/m2
Rendering, screed (50 mm thk.) = 1.150 kN/m2 Living Area = 2.50 kN/m2
~choose~ 0.000 Office = 2.50 kN/m2
Services = 0.100 kN/m2 Classroom = 3.00 kN/m2
Suspended ceilling = 0.150 kN/m2 Classroom = 3.00 kN/m2
Porch = 3.00 kN/m2
Wet Kitchen = 3.00 kN/m2
Surau = 3.20 kN/m2
Master Bedroom = 3.60 kN/m2
Corridor = 4.00 kN/m2
Library = 4.00 kN/m2
Assembly Area = 5.00 kN/m2
Table 3.13 : Bending moment coefficient for simply
supported two way slab.

ly/lx αsx αsy

1.00 0.062 0.062

1.10 0.074 0.061

1.20 0.084 0.059

1.30 0.093 0.055

1.40 0.099 0.051

1.50 0.104 0.046

1.75 0.113 0.037

2.00 0.118 0.029


Table 4.1: Exposure class related to environmental conditions in
accordance with EN 206-1 (Ref. MS EN 1992-1-1: 2010)

CLASS DESCRIPTION
~choose~
For concrete without reinforcement or embedded metal: all
exposure except where there is freeze/thaw, abrasion or
XC0
chemical attack. For concrete with reinforcement or embedded
metal: very dry

XC1 Dry or permanently wet


XC2 Wet, rarely dry
XC3 Moderate humidity
XC4 Cyclic wet and dry
XD1 Moderate humidity
XD2 Wet, rarely dry
XD3 Cyclic wet and dry
XS1 Exposed to airborne salt but not in direct contact to sea water
XS2 Permanently submerged
XS3 Tidal, splash and spray zones
XF1 Moderate water saturation, without de-icing agent
XF2 Moderate water saturation, with de-icing agent
XF3 High water saturation, without de-icing agents
XF4 High water saturation, with de-icing agents or sea water

You might also like