PRISM: An Introduction
MARGARET F. FELS
Center for Energy and Environmental Studies, Princeton University, Princeton, NJ 08544 (U.S.A.)
(Received January 1986)
(a)
LONGT
-ERMDEGREED
-AYS
I-
I FOR
MONTHLYSlLLINGHOUSES,
DATA I I N RAWSAVINGS
TREATMENT
PREANDPOST MA
OC
UFS
O
ER
ST
,R
PREAN
EATMEO
DPNT
ST
CONTROL-ADJUSTED
SAVINGS[
I MONTHLY
BILLING
FORCONTROL DATA I~"
HOUSES,
PREANDPOST
"--~PRISM I ~ j
NACFORCONTROL
HOUSES.PREANDPOST
DALLYTEMPERATURE
DATA I--~
I LONG-TERM
DEGREE
DAYS IloTHERPH~S,CAL~RAMETERS
fOR HOUSES
ALL
I
I
(b)
Fig. 1. Schematic diagram showing the data requirements for the Princeton Scorekeeping Method (PRISM) and
the estimates that result from it: (a) the basic procedure for one house; and (b) the procedure for calculating
control-adjusted savings for a group of treated houses.
sumption would be during a year under in several important ways: in its physical
typical weather conditions. Total energy foundation, which allows a physically mean-
savings are derived as the difference between ingful interpretation of the results; in its
N A C in the pre- and post-periods. A conser- emphasis on reliability, particularly of the
vation effect is thus neither masked by a cold NAC index, which in general is extremely
winter nor exaggerated by a warm one, nor well determined; in its standardized output,
is it obscured if the time covered by billing which facilitates comparisons across pro-
periods in one " y e a r " is longer or shorter grams, and its accurate error diagnostics
than in another. attached to all the estimates it produces; in
PRISM is certainly not the first m e t h o d to its availability, to a wide variety of potential
include weather normalization. In fact, the scorekeepers; and, finally, in its objective of
simple relationship between a house's energy generality, to all fuel types and to a wide
consumption for space heating and outside range of building types and climates.
temperature was recognized, in the published We define the word "scorekeeping" to
literature, at least 80 years ago [3]. Even mean the measurement of actual energy
before natural gas pipelines were available, savings. PRISM is thus a particular score-
weather information was crucial input to gas keeping method. Its purpose is to describe
dispatching and production decisions [4]. In the past rather than predict the future. A
the current literature, there is a variety o f static model, PRISM is not appropriate, as
methods that have features similar to some dynamic models are, for the manage-
PRISM's [5]. ment of a building -- to schedule thermostat
The origins o f PRISM date back to Prince- setbacks, for example. On the other hand,
ton University's earliest energy analyses of these dynamic models are overly complicated
buildings, in the 1970s [6, 7]. In its current for scorekeeping, which requires only long-
form, PRISM differs from other approaches term averages of consumption, i.e., data that
are readily available for large numbers of Adjustment for the performance of a group
houses, or buildings in general. PRISM is of untreated, "control" houses can be an
designed to be a scorekeeping tool that makes important part of scorekeeping, when it is
the best possible use of such data. desirable to decouple the savings induced
by the measures of interest from the savings
that would otherwise have occurred due to
TOWARD A STANDARDIZED APPROACH external events (such as increased energy
prices). Evidence of extensive and continuing
Until recently, the haphazard array of conservation over the decade since the Arab
approaches used to evaluate retrofit programs oil embargo, in the population at large, con-
has made it impossible to compare savings firms the importance of adjusting the savings
from one program to another, or to aggregate by a control group (see ref. 15p, in this issue).
the effects across programs. When the first PRISM applied to both treatment and control
"scores" came in from selected RCS and houses, as shown in Fig. l(b), gives a measure
weatherization programs, many of them were of control-adjusted as well as weather-
disappointing [8]; yet, the lack of a coordi- adjusted savings for the treatment group.
nated approach has made it impossible to The analysis can then be updated for succeed-
learn from mistakes or to plan for more ing years, to track the durability of the
effective programs in the future. savings (see ref. 15c, in this issue).
The progression of recent conferences Invariably, an evaluation of a conservation
testifies to the increased commitment to program ought to go beyond the PRISM
scorekeeping based on real data [ 9 - 1 4 ] . analysis, to determine the cost-effectiveness
At an evaluation conference in Columbus, of various tried approaches to conservation,
Ohio, held in 1982 (the first of its kind), for example, or to clarify the reasons why
many participants disputed the merits of some households saved more than others.
billing data and argued the success of their The savings estimates, along with other
programs either on the basis of number of PRISM outputs, provide reliable input to such
participants or from engineering estimates analyses. Thus the PRISM analysis depicted
of the energy saved, rather than from knowl- in Fig. 1 may be thought of as standardized
edge of actual savings achieved [9]. Since scorekeeping, representing stage one of the
then, especially at biennial summer studies evaluation, while subsequent analyses, limited
in Santa Cruz, California, the discussion of by available data and shaped by the specific
evaluation has shifted from "whether" to needs of the project being evaluated,
" h o w " to use real data [11, 12]. Now, as constitute stage two.
seen at the 1985 evaluation conference in In this special double issue, PRISM is
Chicago, there is agreement on the impor- presented as a standardized, easy-to-use
tance of a standardized approach for measur- approach which utilities, communities, re-
ing energy actually saved, and, among many, searchers and entrepreneurs throughout the
consensus on PRISM as the method of choice country can adopt for measuring energy
[14]. (Two of the several PRISM-based evalu- savings. Fifteen applications of PRISM are
ations reported at the conference are sum- reported, ranging from specific studies of the
marized in refs. 15b and 15c, in this issue.) interpretation of PRISM parameters to
The seemingly inevitable, and occasionally full-scale evaluations of retrofit programs
embarrassing, shortfall of actual savings [15].
relative to engineering estimates is now A brief outline of these papers is given at
part of the common experience. Further, the end of this introductory paper. We
the availability of a well tried method for present now a description of the method:
measuring these savings is allowing the its physical rationale, the statistical procedure
concern to shift to broader issues: h o w to underlying it, and a sample savings analysis
choose the control group, h o w to use the to illustrate its use. Our description here is
savings estimates to evaluate a program's fairly detailed; it is intended to serve as a
cost-effectiveness, and what conservation reference for the other papers. The occasional
lessons can ultimately be learned from com- variation on the method presented here is
parisons across programs. identified in the relevant paper.
8
F~ = ~ + ~Hi(r) + e~ (3)
A NOV
B DEC
2,1978
5,1978
to DEC
t o JAN
9,1918-
~,1919
10 T = 20.0 (+1.5)°c
C C JAN
O FfB
5,1979 to FEB
2,1979
1,1979
t o MAR 6 , 1 9 7 9
[68.0 (+2.8)°F]
E MAR 7,1979 t o APR 2 , 1 9 7 9
f APR 3,1979 t o MAY 1 , 1 9 7 9 C~ = 1.12 (-+0.33) k W t h
G MAY 2,1979 t o MAY 3 1 , 1 9 7 9
H JUN 1,1979 tO JUL 1,1979- [0.90 (-+0.26) ccf/day]
~6 I
J
K
L
JUL 2 , 1 9 7 9 t o JUL 3 1 , 1 9 7 9
AUG I , t 9 7 9 t o AUG 2 9 , 1 9 7 9
AUG 3 0 , 1 9 7 9 tO SEP 3 0 , 1 9 7 9
OCT 1 , 1 9 7 9 tO OCT 3 0 , 1 9 7 9
= 40o (-+30) Wth/°C
[0.18 (-+0.01) ccf/°F-day]
6 ~: 107.1 (-+9.1) GJth/year
~Ho =
H k
*The sample gas-heated house is house T120 from the
I I J Modular Retrofit Experiment [15a]. The estimates
are derived from PRISM applied to the pre-retrofit
o I I I I I I I I I I I O consumption data shown in Fig. 4. Each number in
(a)
2 3 4 5 6 7 8 9 IO II 12 parentheses is the standard error of the estimate.
Period#
A:
t
z
(11/2/78-
,o,,,,.,
M
....
~o..~-,__~
POST [
I
/o
(5/ 2/80-1
oO
£
As is well demonstrated by the studies
reported in this special issue, NAC is a reliable
and stable index of consumption. At best,
the other PRISM parameters provide physical-
ly meaningful indicators, whose changes
may not be statistically significant but whose
4/24181 )Jl behavior can often suggest the reason for
a consumption change. The need for careful
interpretation of these indicators is an im-
portant theme o f this issue. Accurate standard
I I I -o errors for all the parameters [c~, ~, r, [JHo(r),
OIJUL 78 OI JAN 79 OI JUL 79 OIJAN 80 OIJUL80 and NAC] are part of the standard PRISM
Period starting dote
output. Developed for this model, the "com-
Fig. 5. Illustration of sliding PRISM, in which the
posite" m e t h o d for estimating the errors
one-year estimation period, starting o n the date
indicated, is moved forward one m o n t h at a time. includes the uncertainty in the estimation
NAC estimates are shown, for the sample gas-heated of r as well as the estimation error from
house used for Fig. 4 and Table 1. Dashed lines give fitting eqn. (3) [16]. It turns out that ~ and
standard errors of the estimate. Pre- and post-retrofit fl are m u c h more sensitive to variations in r
periods used for scorekeeping are indicated. than is NAC (see Fig. 2 of ref. 15k). Even
in extreme cases when one or more of the
When a continuous series o f consumption parameters is poorly determined, the standard
data is available, a sliding analysis such as error of. NAC is usually only 2 - 4% of the
this one can be a powerful tool not only for estimate*. This stability of NAC is PRISM's
selecting the final estimation periods, but most important feature.
also for flagging anomalies in the data, and,
more generally, for monitoring gradual Estimation of group savings
changes in consumption. This technique has The NAC estimate provides the basic index
been used in a systematic study of the stabil- for measuring energy savings, in groups of
i t y of PRISM parameters (see ref. 15n, in this houses from one to thousands. Computed as
issue). the change in NAC between two periods of
While it is tempting to attribute a change interest, the savings estimates are weather-
in a to water-heater wrap or more efficient adjusted, and thus are independent of changes
appliances, for example, or a drop in j3Ho(r) in the weather between the two periods.
to added ceiling insulation or other measures When adjustment by a control group is
to tighten the structure (through ~) or to needed, an ideal control group is one con-
lowered thermostat settings (through r), structed by random selection of participants
such simple physical inferences from individ- from a larger set, where some or all of those
ual-house results are usually not valid (see not selected for t r e a t m e n t become the con-
Appendix 1). For one thing, events affecting trols. {This approach is used in ref. 15a.)
only one parameter are not likely to occur Often such advanced planning is not possible.
in isolation. For another, PRISM's assump- A less ideal though generally adequate pro-
tions that ~, ~ and r are constant on average
f r o m m o n t h to m o n t h over a year-long esti- * N A C can be reliable even in the event of an
extreme anomaly, for example, w h e n best v is estab-
mation period are not likely to hold perfectly
lished at the highest value of daily temperature for
in any real house. The change in the temper- the estimation period. (The associated standard error
ature<lependent c o m p o n e n t of NAC, t3Ho(r), of r is infinite.) Only two such anomalies occurred
is usually better determined than the change in the data set of 276 cases from which the example
in ~ or r individually, just as NAC is better in Fig. 4 was taken [15a]. For each of the two
cases, only six (bimonthly) data points were available.
determined than either that c o m p o n e n t or
In both cases, N A C was well determined: the stan-
the base-level component, 365a. Nevertheless, dard errors of N A C were 3.0% and 6.0% of the
the effect of the seasonal variability of ap- estimate, and thecorresponding R 2 values were 0.99
pliance and water-heater usage, investigated and 0.94, respectively.
12
As has been the case in other retrofit pro- has used P R I S M for the evaluation of Wis-
grams, the control adjustment substantially consin's low-income weatherization program
deflates this experiment's raw savings. Never- involving 1000 houses [15b]. Researchers
theless, the savings in the house<loctor group at Oak Ridge National Laboratory are using
relative to the control group were highly P R I S M as stage one of a two,stage approach,
statistically significant (see ref. 15a). to evaluate R C S and other utility conserva-
tion programs, such as Bonneville Power Ad-
ministration's Residential Weatherization
Pilot Program [15c]. The Center for the
OTHER APPLICATIONS
Biology of Natural Systems at Queens College
has applied P R I S M to a smaller sample of
The accuracy of the estimates from our houses in N e w York City, for a detailed com-
sample analysis is typical of other applications parison of two approaches to low-income
of PRISM, both to gas-heated and oil-heated weatherization [15d]. The method is being
houses and to electrically heated houses used extensively in Minnesota to monitor
without cooling. Summaries of model per- the success of a variety of city and state
formance are found elsewhere in this issue programs; using PRISM, the Minneapolis
(for example, refs. 15a and 15b for natural Energy Agency has carried out a definitive
gas, ref. 15k for oil, and refs. 15c and 15h comparison of predicted vs. actual savings
for electricity). For houses in heating- from R C S retrofits [15e].
dominated climates, we have found R 2- Recently, researchers have begun to rec-
values to average 0.97, and standard errors ognize the almost untapped resource of
for NAC to average 3 - 4% of the NAC esti- energy savings in multifamily buildings. In
mate. Even in the face of some anomalies apartments in N e w Jersey, for example, the
in the individual-parameter results, NAC and average energy usage per unit floor area m a y
the corresponding savings estimates are be double what it is in single-family houses,
usually stable and reliable. in spite of potential benefits from c o m m o n
The model used in the above example, walls in apartments*. As part of its shift in
and in almost all papers in this issue, is the research emphasis from single-family to
"heating only" PRISM model for individual multifamily buildings, the Center for Energy
houses. Two adaptations of this model have and Environmental Studies at Princeton has
also been developed, for individual houses extensively instrumented a 60-unit gas-heated
with electric cooling as well as heating [15h], apartment building in Asbury Park, New
and for large aggregates of gas-heated houses Jersey [15f]. High interior temperatures
for which only total utility sales data are coupled with an unusual boiler configuration
available [15p]. For the former, cooling challenge the interpretability of the PRISM
analogues of ~ and r are added to the model estimates; an engineering analysis of addition-
in eqn. (3). For the latter, a variation of al data provides an improved understanding
H~(T) in the same equation is used to account of the results. Lawrence Berkeley Labora-
for the billing lag. For both adaptations, tory's study of a complex of apartment
NAC is on average as well determined as it is buildings in the San Francisco Housing
in individual-house, heating-only applications. Authority offers another test of the applic-
ability of PRISM to large multifamily build-
ings [15g].
OVERVIEW OF THE ISSUE
APPENDIX 2
APPENDIX 3
Computation of group savings estimates
We let the notation [X]I T and IX] Ic rep- Standard errors of savings estimates
resent the median (or mean) of the set of The standard errors of the savings estimates
values of the quantity X for the treatment are obtained from the standard errors of
(T) or control (C) group, respectively. NACpr e and NACpost, i.e., se(NACpre) a n d
In analogy with the individual-house se(NACpo,t), which are computed by a
savings in eqns. (5a) and (5b), the raw, method developed for PRISM [16] and are
weather-adjusted savings for the treatment included in the standard output for each
group is given, in absolute terms, by: house analyzed. For an individual house:
Sraw(T) = [NACpr e -- NACpost ] IT (A8a) se(Sraw) = [se2(NACpre) + se2(NACpost) ] 1/2
and, in percent terms relative to NACpre, by (A12)
This provides a measure of the variability of used to represent a measure of the variation
t h e s a m p l e m e d i a n * . F o r a given q u a n t i t y across houses. T o s o m e e x t e n t , t h e l a t t e r
X , e q n . ( A 1 4 ) o r ( A 1 5 ) , r e s p e c t i v e l y , tells includes t h e e f f e c t o f t h e m e a s u r e m e n t e r r o r
how accurately the mean or median has been f o r e a c h h o u s e (eqns. ( A 1 2 ) a n d ( A 1 3 ) ) ,
e s t i m a t e d f o r t h e larger g r o u p o f h o u s e s f r o m w h i c h is g e n e r a l l y , f o r all P R I S M p a r a m e t e r s ,
w h i c h t h e s t u d y g r o u p was d r a w n . T h u s t w o m u c h smaller t h a n t h e c o r r e s p o n d i n g esti-
alternative representations for the center of mate's variation from house to house.
t h e d i s t r i b u t i o n o f X f o r a set o f h o u s e s m a y
be w r i t t e n : REFERENCES
mean(X) + se[mean(X)] 1 U. S. Department of Energy, Residential Conser-
vation Service Program: Final Rule, Federal
and Register, 47 (123) (June 25, 1982) 27752-
27803; see also National Energy Conservation
median(X) + se[median(X)].
Policy Act, Public Law 95- 619, Part 1 of Title
I n t h a t t h e y are m o r e insensitive t o o u t - II, 1978.
liers, t h e m e d i a n m e a s u r e s ( m e d i a n value, 2 The Bradley Plan: Home energy conservation pro-
gram, Congressional Record, 125 (107) (July 31,
i n t e r q u a r t i l e range, a n d s t a n d a r d e r r o r o f t h e
1979) 10950 - 53, Washington, DC; see also
s a m p l e m e d i a n ) are r o b u s t a l t e r n a t i v e s t o t h e Energy Security Act, Public Law 96.294, Sub-
m e a n m e a s u r e s ( m e a n value, s t a n d a r d devia- title C of Title V, 1980.
tion, and standard error of the sample mean). 3 Examples of early papers are: Highest economy
Since o u t l i e r s m a y s t r o n g l y i n f l u e n c e t h e in furnace heating: Proper temperatures, ventila-
tion and coal consumption for different outside
m e a n value, in an a m o u n t t h a t m a y s u b s t a n -
temperatures, The Metal Worker, Plumber and
tially d i s t o r t t h e r e s u l t i n g r e p r e s e n t a t i o n o f Steam Fitter, 66 (Nov. 10) (1906) 47 - 49 ("For
a g r o u p ' s savings ( f o r X = NACpre - - NACpost), any given outside temperature there is a corre-
t h e m e d i a n m e a s u r e s are usually m o r e m e a n - sponding amount of heat that must be supplied
ingful. O n t h e o t h e r h a n d , m e a n m e a s u r e s are in order to offset the heat losses through the walls
o c c a s i o n a l l y m o r e c o n v e n i e n t , since classical and windows", p. 47); and R. P. Bolton, Heating
requirements in New York weather, Heating and
t-tests o f significance are r e a d i l y available f o r Ventilation Magazine, VIII (March) (1911) 1 - 10
them. In addition, a comparison of the mean ("An analysis of the weather conditions actually
a n d m e d i a n values is o f t e n useful, f o r o b t a i n - prevailing during the heating season in a city like
ing a sense o f t h e s k e w n e s s o f t h e distribu- New York may be made a very useful guide in
tion. determining the heating requirements, both for
the whole period and for any given portion of
For scorekeeping, we recommend compu- the period", p. 1).
t a t i o n o f b o t h sets o f m e a s u r e s f o r t h e q u a n t i - 4 J. Wright (private communication), Gas Planning
ties o f interest. In general, w e r e l y o n t h e Department, Public Service Electric and Gas
median measures, after they have been com- Company, Newark, NJ, 1985.
pared with the mean measures. 5 M. Fels, R. Socolow, J. Rachlin and D. Stram,
PRISM: A Conservation Scorekeeping Method
F o r t h e s a m p l e s c o r e k e e p i n g analysis Applied to Electrically Heated Houses, Center
p r e s e n t e d in t h e t e x t , t h e s t a n d a r d errors o f for Energy and Environmental Studies, Princeton
t h e savings f o r t h e single g a s - h e a t e d h o u s e University, Princeton, NJ, EPRI Report No.
w e r e c o m p u t e d f r o m eqns. ( A 1 2 ) a n d ( A 1 3 ) ; EM-4358, Palo Alto, CA, December 1985, Ap-
pendix 1.
t h e s e r e p r e s e n t m e a s u r e m e n t errors. T h e stan-
6 T. Schrader, A Two-Parameter Model for Asses-
dard error of the sample median of the house- sing the Determinants of Residential Space
d o c t o r g r o u p ' s savings, f r o m e q n . ( A 1 5 ) , w a s Heating, MS Thesis, Department of Aerospace
and Mechanical Engineering, Princeton Univer-
sity, Report No. 69, Center for Energy and En-
*The standard error of the median is a new quantity vironmental Studies, Princeton, NJ, June 1978.
inferred from other work [20, 21]. Use of eqns. 7 F. Sinden, A two-thirds reduction in the space
(A14) and (A15) for the standard error of the mean heat requirement; and L. Mayer and Y. Benja-
or of the median implicitly assumes that the errors in mini, Modeling residential demand for natural
estimating a given quantity in different houses are gas as a function of the coldness of a month, in
uncorrelated. If this assumption is invalid, these for- R. Socolow (ed.), Saving Energy in the Home,
mulae understate the uncertainty of their respective Ballinger Publishing Co., Cambridge, MA, 1978.
mean and median estimates, though not by much if 8 E. Hirst, Household energy conservation: a review
(as is usually the case) the measurement errors are of the federal Residential Conservation Service,
small relative to the house-to-house variation of the Public Administration Review, 44 (5) (1984)
estimate. 421 - 430.
18
9 Battelle, Columbus Laboratories, Workshop Pro- San Francisco Housing Authority, pp. 89 -98.
ceedings: Measuring the Effects of Utility Con- h D. Stram and M. Feis, The applicability of
servation Programs, February 1982, Columbus, P R I S M to electric heating and cooling, pp. 101
OH, EPRI Report No. EA-2496, Palo Alto, CA, - 110.
July 1982. i M. Fels and D. Strata, Does P R I S M distort the
10 Synergic Resources Corporation, Proc. Confer- energy signature of heat-pump houses?, pp.
ence on Utility Conservation Programs: Planning, 111 118.
-
Analysis, and Implementation, October 1983, j M. Feis and D. Strata, The effect of burning
New Orleans, LA, EPRI Report No. EA-3530, w o o d on saving electricity,pp. 119 - 126.
Palo Alto, CA, May 1984. k M. Feis, M. Goldberg and M. Lavine, Explora-
11 J. Harris and C. Blumstein (eds.), What Works: tory scorekeeping for oil-heated houses, pp.
Documenting Energy Conservation in Buildings, 127 - 136.
Summary of the 1982 ACEEE Summer Study m M . Fels, J. Rachlin and R. Socolow, Seasonal-
on Energy-efficient Buildings held August 1982 ity of non-heating consumption and its effect
in Santa Cruz, CA, American Council for an on P R I S M results, pp. 139 - 148.
Energy-Efficient Economy, Washington, DC, n J. Rachlin, M. Fels and R. Socolow, The stabil-
1984. ity of P R I S M estimates, pp. 149 - 157.
12 Doing Better: Setting an Agenda for the Second p M. Fels and M. Goldberg, Using the scorekeep-
Decade, Proc. 1984 ACEEE Summer Study on ing approach to monitor aggregate energy con-
Energy.efficient Buildings, August 1984, Santa servation, pp. 161 - 168.
Cruz, CA, American Council for an Energy- q M. Goldberg and M. Fels, Refraction of P R I S M
Efficient Economy, Washington, DC, 1984. results into components of saved energy, pp.
13 Proc. Weatherization 1985: Midwest Technical 169 - 180.
Conference, Chicago, IL, February 1985, Ar- 16 M. Goldberg, A Geometrical Approach to Nondif-
gonne National Laboratory, Argonne, IL, 1985. ferentiable Regression Models as Related to Meth-
14 Proc. Second National Conference, Energy Con- ods for Assessing Residential Energy Conserva-
servation Program Evaluation: Practical Methods, tion, Ph.D. Thesis, Department of Statistics,
Useful Results, Chicago, IL, August 1985, Vol. I Princeton University, Report No. 142, Center for
(Session 4: PRISM Workshop, Session 5: Weather- Energy and Environmental Studies, Princeton,
ization Program Evaluation, and Session 8: Using NJ, 1982.
PRISM), Argonne National Laboratory, Argonne, 17 National Oceanic and Atmospheric Administra-
IL, 1985. tion (NOAA), Local Climatological D a t a -
15 Energy and Buildings, 9 (1 and 2) this issue; Monthly Summary [name of weather station],
papers in the order of their appearance: National Climatic Data Center, Asheville, NC,
a O. Dutt, M. Lavine, B. Levi and R. Socolow, monthly publication.
The Modular Retrofit Experiment: design, 18 R. Socolow, Field Studies of Energy Savings in
scorekeeping and evaluation, pp. 21 - 33. Buildings: a Tour of a Fourteen-Year Research
b M. Goldberg, A Midwest low-income weatheri- Program at Princeton University, Report No. 191,
zation program seen through PRISM, pp. 37 - Center for Energy and Environmental Studies,
44. Princeton University, Princeton, NJ, July 1985;
c E. Hirst, Electricity savings one, two, and three presented at the Soviet-American Symposium on
years after participation in the BPA Residential Energy Conservation, Moscow, June 6 - 12, 1985;
Weatherization Pilot Program, pp. 45 - 53. to be published in Energy.
d L. Rodberg, Energy conservation in low-income 19 W. Shurcliff, Superinsu~ated Houses and Double-
homes in New York City: the effectiveness of envelope Houses: A Survey of Principles and
house doctoring, pp. 55 - 64. Practice, Brick Publishing Co., Andover, MA,
e M. Hewett, T. Dunsworth, T. Miller and M. 1981, p. 9.
Koehler, Meabured vs. predicted savings from 20 E. Parzen, A density-quantile function perspective
single retrofits: a sample study, pp. 65 - 73. on robust estimation, in R. Launer and G. Wil-
f J. DeCicco, G. Dutt, D. Harrje and R. Socolow, kinson (eds.), Robustness in Statistics, Academic
PRISM applied to a multifamily building: the Press, New York, NY, 1979.
Lumley Homes case study, pp. 77 - 88. 21 C. Hurvich, Center for Energy and Environmental
g C. Goldman and R. Ritschard, Energy conser- Studies, Princeton University, Princeton, NJ,
vation in public housing: a case study of the private communication, November 1985.