PUMP SIZING/SELECTION Electric Submersible Pumping System

WELL DATA Date : 7-Mar-23

Company : Texcal Mahato Instrument : PSI


Well Name : PB-020 Casing Size/ ID : 7.000 6.276 inch Tubing Length : 0 feet
Liner OD : 7.000 inch Perforation : 5,462 5,472 feet Frequency : 60 Hz
Top of Liner at : 0 feet Mean Perf. Depth : 5,467 feet Max. Dev. Angle : 0 deg
Bottom of Liner at : 0 feet Tubing Size/ ID : 3.500 2.992 inch Max. Rate of Dev. Angle : 0 deg/ft

RESERVOIR DATA

Pump Setting Depth : 5,362 feet Static Bottom Hole Press. : 2,010 psi Casing Pressure : 0 psi
Flow Rate : 700 BFPD Flowing Bottom Hole Press. : 850 psi Water Spec. Grav. : 1
Water Cut : 30.0 % Bubble Point Pressure : 100 psi Gas Spec. Grav. : 1.19
GOR (SCF/STB) : 35 Well Head Temperature : 0 deg.F Init. Resev. Temp. : 245 deg.F
Static Fluid Level : 304 feet Well Head Pressure : 10 psi at : 3,500 feet
Flowing Fluid Level : 3,284 feet Deg. API : 33.8 Oil Viscosity : 2.42 cp

COMPLETED BY

Name : Anggraita Date : 7-Mar-23


Company : PT EJP

DESIRED PARAMETER

Pump Setting Depth : 5,362 feet Well Head Press. : 25 psi Minimum FOP : 400 feet
Production Flow Rate : 806 BFPD Frequency : 60 Hz Cable Size : Size-4

SELECTION AND CALCULATION

Fluid Spec. Gravity : 0.899 Pump Type : IND750 Min. Motor Load : 37.6 HP
Comp. Spec. Gravity : 0.821 Head/Stg : 22.12 feet Selected Motor : 50 HP
Productivity Index (PI) : 0.603 bfpd/psi BHP/Stg : 0.204 HP Motor Voltage : 1,100 Volt
Working Fluid Level : 3,734.8 feet Minimum Stages : 172 Motor Current : 29 Amp
Well Head Pressure : 64.2 feet Selected Stages : 172 Motor Series : 540S
Friction Loss : 13.2 feet Selected Head : 3,804.0 feet Surface Cable Length : 150 feet
Total Dynamic Head : 3,812.3 feet BHP Pump Only : 35.07 HP Total Cable Length : 160 feet
Flowing Pressure : 674 psi Intake Type : Int KGS 400S Surface Voltage : 1,102 Volt
Pump Intake Pressure : 633.5 psi AGH Type : None Max. Motor Load : 55.25 KVA
Fluid Over Pump : 1,627 feet Type of Protector-1 : PFDB 540S Cable Losses : 0.22 KW
Fluid Gradient : 0.389 psi/ft Type of Protector-2 : None Total KVA : 55.43 KVA
GLR (STF/STB) : 0.00 GS/Intake Length : 3.1 feet Selected Transformer : 350 KVA
GVF (Gas Vol.Fract.) : 0.00 % Min. MLE Length : 29.2 feet Motor Capacity : 50 HP
Pump Length : 13.4 feet Motor Length : 10.1 feet Est. Running Amper : 20.15 amp
Protector Length : 6.7 feet Total Unit String Length : 33.3 feet VSD : Yes

OTHER CONDITIONS/REMARKS
PSD : 5361.77 ftTVD
PSD : 6271 ftMD

Monday, March 20, 2023