Professional Documents
Culture Documents
r2b p2 203 03 H HD 51062 - Rev.b - Data Sheet SRV PSV 61152 A B 1st Stage Discharge
r2b p2 203 03 H HD 51062 - Rev.b - Data Sheet SRV PSV 61152 A B 1st Stage Discharge
Received
INSTRUMENT DATA SHEET 05 Apr 2021
DOCUMENT TITLE
SAFETY RELIEF VALVES
SIGN
DATE
SAMSUNG ENGINEERING CO., LTD
Siemens Energy
AGC Sanmar Limited Pressure Relief Valve Sizing & Selection Report
(formerly Pentair Sanmar Ltd) 3 VRS VRS VRS 25-Mar-2021
(Formerly Tyco Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
Tamilnadu, India 1 VRS VRS VRS 3-Dec-2020
0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: Dos Bocas New Refinery Project, Mexico Project Ref. No.: X-45181
1 Valve ID 41 SIZING DATA
2 Tag No. PSV-61152 A/B 42 Design Code ASME Section VIII Sizing Std. API 520
3 Service 1st Stage Discharge 43 Sizing Basis Blocked Discharge
4 PID No. 44 Fluid State at Inlet Gas / Vapor
5 Line No. Quantity 45 Relieving Case Pressure Relief
6 D-R Mat Code WIN51645ABBT1 8 46 Fluid Properties
7 GENERAL 47 Fluid Name Hydrogen.
8 Valve Type Balanced Bellows, Direct Spring-Operated 48 Molecular Weight, M 2.03
9 Safety / Relief Safety Balanced Yes 49 Compressibility, Z 1.022
10 Nozzle Full Bonnet Vented 50 Ratio of Sp. Heats, k (Cp / Cv) 1.412
11 CONNECTIONS 51 Gas Constant, C 357.1
12 Inlet 1" Flngd. 600# RTJ Standard 52
13 Outlet 2" Flngd. 150# RF ASME B16.5 53
14 MATERIALS OF CONSTRUCTION 54
15 Body Killed CS SA216-WCB 55
16 Bonnet Killed CS SA216-WCB 56
17 Nozzle 316 SST 57
18 Disc 316 SST 58
19 Seat 316 SST 59 Sizing Coefficients Unit -
20 Spindle 316 SST 60 Effective K, Gas 0.975
21 Guide SS A297 Gr. HE 61 Kb Kc 0.997 1
22 Spring Chrome Steel 62
23 Gaskets 316 SST 63
24 Bellows 316L SST 64 Required Capacity Unit kg/hr
25 Cap Type Screwed w/ Test Rod 65 Total 1001.03
26 NACE MR0175/ISO 15156:2015 No 66
Accessories
mm
16.33
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Calculation Report
(formerly Pentair Sanmar Ltd) 3 VRS VRS VRS 25-Mar-2021
(Formerly Tyco Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
Tamilnadu, India 1 VRS VRS VRS 3-Dec-2020
0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: Dos Bocas New Refinery Project, Mexico Project Ref. No.: X-45181
1 VALVE ID 11 CALCULATION NOTES
2 Tag No. PSV-61152 A/B 12
3 Valve Model No. 1E2 JBS-E-45-K-SPL Qty. 8 13
4 SIZING DATA 14
5 Design Code ASME Section VIII Sizing Std. API 520 15
6 Fluid State at Inlet Gas / Vapor 16
7 CALCULATION SUMMARY
8 Required 1001.03 kg/hr 18 Required 1.016 cm²
Flow Area
9 Maximum 1246.106 kg/hr 19 Selected 1.265 cm²
10 Reaction Force, Open Discharge 61.9 kgf 20 Noise Level (db), Open Discharge 140.2 at 1 m
Variable Type Variable Name Symbol Input Value Equation Value
Fluid Properties Molecular Weight M 2.03 2.03
Ratio of Specific Heats k 1.412 1.412
Compressibility Z 1.022 1.022
Process Cond. Required Mass Flow Wreq 1001.03 kg/hr 2206.893 lb/hr
Set Pressure Pset 46.5 kg/cm² g 661.385 psig
Over Pressure Pover 4.65 kg/cm² g 66.139 psig
Inlet Line Loss Ploss 0 kg/cm² g 0 psig
Back Pressure Pback 13.95 kg/cm² g 198.416 psig
Atmospheric Pressure Patm 1.033 kg/cm² a 14.696 psia
Relieving Temperature T 99.52 °C 670.806 °R
Distance from Valve (noise) r 1m 3.2808 ft
Rupture Disc CCF Kc 1 1
Valve Data Discharge Coefficient (API) K,API 0.975 0.975
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Calculation Report
(formerly Pentair Sanmar Ltd) 3 VRS VRS VRS 25-Mar-2021
(Formerly Tyco Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
Tamilnadu, India 1 VRS VRS VRS 3-Dec-2020
0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: Dos Bocas New Refinery Project, Mexico Project Ref. No.: X-45181
1 VALVE ID 11 CALCULATION NOTES
2 Tag No. PSV-61152 A/B 12
3 Valve Model No. 1E2 JBS-E-45-K-SPL Qty. 8 13
4 SIZING DATA 14
5 Design Code ASME Section VIII Sizing Std. API 520 15
6 Fluid State at Inlet Gas / Vapor 16
7 CALCULATION SUMMARY
8 Required 1001.03 kg/hr 18 Required 1.016 cm²
Flow Area
9 Maximum 1246.106 kg/hr 19 Selected 1.265 cm²
10 Reaction Force, Open Discharge 61.9 kgf 20 Noise Level (db), Open Discharge 140.2 at 1 m
Calculate Noise Level at 100-ft (30-m) L100 110.6 db
L100 = [6.5 * log( 1/PR ) + 51.28] + [10 * log(0.29354 * W * k * T / M)]
Calculate Reaction Force for Open Discharge Fr 61.9 kgf 136.5 lbf
Ao = (π * Do^2) / 4
Fr = (A * C * K,API * P1 * Kc / 366) * {k / [(k + 1) * Z]}^0.5 + (Ao * Po)
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Dimensional Drawing
(formerly Pentair Sanmar Ltd) 3 VRS VRS VRS 25-Mar-2021
(Formerly Tyco Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
Tamilnadu, India 1 VRS VRS VRS 3-Dec-2020
0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: Dos Bocas New Refinery Project, Mexico Project Ref. No.: X-45181
1 Valve ID 7 SELECTION SUMMARY
2 Tag No. PSV-61152 A/B 8 Valve Model No. 1E2 JBS-E-45-K-SPL
3 Service 1st Stage Discharge 9 Brand Crosby®
4 PID No. 10 CONNECTIONS
5 Line No. Quantity 11 Inlet 1" Flngd. 600# RTJ Standard
6 D-R Mat Code WIN51645ABBT1 8 12 Outlet 2" Flngd. 150# RF ASME B16.5
Wt.= 36 lb = 16.33 kg
A= 4.13 in = 104.90 mm
B= 4.50 in = 114.30 mm
C= 20.25 in = 514.35 mm
D= 1.56 in = 39.62 mm
E= =
F= =
G= =
H= =
Dimension Notes
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Sizing & Selection Report
(formerly Pentair Sanmar Ltd) 3 VRS VRS VRS 25-Mar-2021
(Formerly Tyco Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
Tamilnadu, India 1 VRS VRS VRS 3-Dec-2020
0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: Dos Bocas New Refinery Project, Mexico Project Ref. No.: X-45181
1 Valve ID 41 SIZING DATA
2 Tag No. PSV-61154 A/B 42 Design Code ASME Section VIII Sizing Std. API 520
3 Service 2nd Stage Discharge 43 Sizing Basis Blocked Discharge
4 PID No. 44 Fluid State at Inlet Gas / Vapor
5 Line No. Quantity 45 Relieving Case Pressure Relief
6 D-R Mat Code WIN51645ABBT2 8 46 Fluid Properties
7 GENERAL 47 Fluid Name Hydrogen.
8 Valve Type Balanced Bellows, Direct Spring-Operated 48 Molecular Weight, M 2.03
9 Safety / Relief Safety Balanced Yes 49 Compressibility, Z 1.040
10 Nozzle Full Bonnet Vented 50 Ratio of Sp. Heats, k (Cp / Cv) 1.417
11 CONNECTIONS 51 Gas Constant, C 357.6
12 Inlet 1 1/2" Flngd. 900# RTJ Standard 52
13 Outlet 2" Flngd. 300# RF ASME B16.5 53
14 MATERIALS OF CONSTRUCTION 54
15 Body Killed CS SA216-WCB 55
16 Bonnet Killed CS SA216-WCB 56
17 Nozzle 316 SST 57
18 Disc 316 SST 58
19 Seat 316 SST 59 Sizing Coefficients Unit -
20 Spindle 416 SST 60 Effective K, Gas 0.975
21 Guide SS A479-316 61 Kb Kc 0.997 1
22 Spring Chrome Steel 62
23 Gaskets 316 SST 63
24 Bellows 316L SST 64 Required Capacity Unit kg/hr
25 Cap Type Screwed w/ Test Rod 65 Total 1000.86
26 NACE MR0175/ISO 15156:2015 No 66
Accessories
mm
29.48
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Calculation Report
(formerly Pentair Sanmar Ltd) 3 VRS VRS VRS 25-Mar-2021
(Formerly Tyco Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
Tamilnadu, India 1 VRS VRS VRS 3-Dec-2020
0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: Dos Bocas New Refinery Project, Mexico Project Ref. No.: X-45181
1 VALVE ID 11 CALCULATION NOTES
2 Tag No. PSV-61154 A/B 12
3 Valve Model No. 1.5D2 JBS-E-55-K-SPL Qty. 8 13
4 SIZING DATA 14
5 Design Code ASME Section VIII Sizing Std. API 520 15
6 Fluid State at Inlet Gas / Vapor 16
7 CALCULATION SUMMARY
8 Required 1000.86 kg/hr 18 Required 0.562 cm²
Flow Area
9 Maximum 1264.338 kg/hr 19 Selected 0.710 cm²
10 Reaction Force, Open Discharge 63.4 kgf 20 Noise Level (db), Open Discharge 140.4 at 1 m
Variable Type Variable Name Symbol Input Value Equation Value
Fluid Properties Molecular Weight M 2.03 2.03
Ratio of Specific Heats k 1.417 1.417
Compressibility Z 1.040 1.040
Process Cond. Required Mass Flow Wreq 1000.86 kg/hr 2206.519 lb/hr
Set Pressure Pset 85.7 kg/cm² g 1218.941 psig
Over Pressure Pover 8.57 kg/cm² g 121.894 psig
Inlet Line Loss Ploss 0 kg/cm² g 0 psig
Back Pressure Pback 25.71 kg/cm² g 365.682 psig
Atmospheric Pressure Patm 1.033 kg/cm² a 14.696 psia
Relieving Temperature T 101.47 °C 674.316 °R
Distance from Valve (noise) r 1m 3.2808 ft
Rupture Disc CCF Kc 1 1
Valve Data Discharge Coefficient (API) K,API 0.975 0.975
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Calculation Report
(formerly Pentair Sanmar Ltd) 3 VRS VRS VRS 25-Mar-2021
(Formerly Tyco Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
Tamilnadu, India 1 VRS VRS VRS 3-Dec-2020
0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: Dos Bocas New Refinery Project, Mexico Project Ref. No.: X-45181
1 VALVE ID 11 CALCULATION NOTES
2 Tag No. PSV-61154 A/B 12
3 Valve Model No. 1.5D2 JBS-E-55-K-SPL Qty. 8 13
4 SIZING DATA 14
5 Design Code ASME Section VIII Sizing Std. API 520 15
6 Fluid State at Inlet Gas / Vapor 16
7 CALCULATION SUMMARY
8 Required 1000.86 kg/hr 18 Required 0.562 cm²
Flow Area
9 Maximum 1264.338 kg/hr 19 Selected 0.710 cm²
10 Reaction Force, Open Discharge 63.4 kgf 20 Noise Level (db), Open Discharge 140.4 at 1 m
Calculate Noise Level at 100-ft (30-m) L100 110.7 db
L100 = [6.5 * log( 1/PR ) + 51.28] + [10 * log(0.29354 * W * k * T / M)]
Calculate Reaction Force for Open Discharge Fr 63.4 kgf 139.7 lbf
Ao = (π * Do^2) / 4
Fr = (A * C * K,API * P1 * Kc / 366) * {k / [(k + 1) * Z]}^0.5 + (Ao * Po)
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Dimensional Drawing
(formerly Pentair Sanmar Ltd) 3 VRS VRS VRS 25-Mar-2021
(Formerly Tyco Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
Tamilnadu, India 1 VRS VRS VRS 3-Dec-2020
0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: Dos Bocas New Refinery Project, Mexico Project Ref. No.: X-45181
1 Valve ID 7 SELECTION SUMMARY
2 Tag No. PSV-61154 A/B 8 Valve Model No. 1.5D2 JBS-E-55-K-SPL
3 Service 2nd Stage Discharge 9 Brand Crosby®
4 PID No. 10 CONNECTIONS
5 Line No. Quantity 11 Inlet 1 1/2" Flngd. 900# RTJ Standard
6 D-R Mat Code WIN51645ABBT2 8 12 Outlet 2" Flngd. 300# RF ASME B16.5
Wt.= 65 lb = 29.48 kg
A= 4.13 in = 104.90 mm
B= 5.50 in = 139.70 mm
C= 21.00 in = 533.40 mm
D= 2 in = 50.80 mm
E= =
F= =
G= =
H= =
Dimension Notes
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Sizing & Selection Report
(formerly Pentair Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
(Formerly Tyco Sanmar Ltd) 1 VRS VRS VRS 3-Dec-2020
Tamilnadu, India 0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: PEMEX, Maxico Project Ref. No.: X-45181
1 Valve ID 41 SIZING DATA
2 Tag No. 45181A-PSV-101 A/B 42 Design Code ASME Section VIII Sizing Std. API 520
3 Service 1st Stage Discharge 43 Sizing Basis Blocked Discharge
4 PID No. 44 Fluid State at Inlet Gas / Vapor
5 Line No. Quantity 45 Relieving Case Pressure Relief
6 D-R Mat Code WIN51645ABBT1 8 46 Fluid Properties
7 GENERAL 47 Fluid Name Naptha
8 Valve Type Balanced Bellows, Direct Spring-Operated 48 Molecular Weight, M 2.03
9 Safety / Relief Safety Balanced Yes 49 Compressibility, Z 1.022
10 Nozzle Full Bonnet Vented 50 Ratio of Sp. Heats, k (Cp / Cv) 1.412
11 CONNECTIONS 51 Gas Constant, C 357.1
12 Inlet 1" Flngd. 300# RF Standard 52
13 Outlet 2" Flngd. 150# RF ASME B16.5 53
14 MATERIALS OF CONSTRUCTION 54
15 Body Killed CS SA216-WCB 55
16 Bonnet Killed CS SA216-WCB 56
17 Nozzle 316 SST 57
18 Disc 316 SST 58
19 Seat 316 SST 59 Sizing Coefficients Unit -
20 Spindle 316 SST 60 Effective K, Gas 0.975
21 Guide SS A297 Gr. HE 61 Kb Kc 1 1
22 Spring Chrome Steel 62
23 Gaskets 316 SST 63
24 Bellows 316L SST 64 Required Capacity Unit kg/hr
25 Cap Type Screwed w/ Test Rod 65 Total 1001.03
26 NACE MR0175/ISO 15156:2015 No 66
Accessories
mm
16.33
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Calculation Report
(formerly Pentair Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
(Formerly Tyco Sanmar Ltd) 1 VRS VRS VRS 3-Dec-2020
Tamilnadu, India 0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: PEMEX, Maxico Project Ref. No.: X-45181
1 VALVE ID 11 CALCULATION NOTES
2 Tag No. 45181A-PSV-101 A/B 12
3 Valve Model No. 1E2 JBS-E-35-K-SPL Qty. 8 13
4 SIZING DATA 14
5 Design Code ASME Section VIII Sizing Std. API 520 15
6 Fluid State at Inlet Gas / Vapor 16
7 CALCULATION SUMMARY
8 Required 1001.03 kg/hr 18 Required 1.013 cm²
Flow Area
9 Maximum 1250.003 kg/hr 19 Selected 1.265 cm²
10 Reaction Force, Open Discharge 61.9 kgf 20 Noise Level (db), Open Discharge 144.7 at 1 m
Variable Type Variable Name Symbol Input Value Equation Value
Fluid Properties Molecular Weight M 2.03 2.03
Ratio of Specific Heats k 1.412 1.412
Compressibility Z 1.022 1.022
Process Cond. Required Mass Flow Wreq 1001.03 kg/hr 2206.893 lb/hr
Set Pressure Pset 46.5 kg/cm² g 661.385 psig
Over Pressure Pover 4.65 kg/cm² g 66.139 psig
Inlet Line Loss Ploss 0 kg/cm² g 0 psig
Back Pressure Pback 2.1 kg/cm² g 29.869 psig
Atmospheric Pressure Patm 1.033 kg/cm² a 14.696 psia
Relieving Temperature T 99.52 °C 670.806 °R
Distance from Valve (noise) r 1m 3.2808 ft
Rupture Disc CCF Kc 1 1
Valve Data Discharge Coefficient (API) K,API 0.975 0.975
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Calculation Report
(formerly Pentair Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
(Formerly Tyco Sanmar Ltd) 1 VRS VRS VRS 3-Dec-2020
Tamilnadu, India 0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: PEMEX, Maxico Project Ref. No.: X-45181
1 VALVE ID 11 CALCULATION NOTES
2 Tag No. 45181A-PSV-101 A/B 12
3 Valve Model No. 1E2 JBS-E-35-K-SPL Qty. 8 13
4 SIZING DATA 14
5 Design Code ASME Section VIII Sizing Std. API 520 15
6 Fluid State at Inlet Gas / Vapor 16
7 CALCULATION SUMMARY
8 Required 1001.03 kg/hr 18 Required 1.013 cm²
Flow Area
9 Maximum 1250.003 kg/hr 19 Selected 1.265 cm²
10 Reaction Force, Open Discharge 61.9 kgf 20 Noise Level (db), Open Discharge 144.7 at 1 m
Calculate Noise Level at 100-ft (30-m) L100 115.0 db
L100 = [6.5 * log( 1/PR ) + 51.28] + [10 * log(0.29354 * W * k * T / M)]
Calculate Reaction Force for Open Discharge Fr 61.9 kgf 136.5 lbf
Ao = (π * Do^2) / 4
Fr = (A * C * K,API * P1 * Kc / 366) * {k / [(k + 1) * Z]}^0.5 + (Ao * Po)
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Dimensional Drawing
(formerly Pentair Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
(Formerly Tyco Sanmar Ltd) 1 VRS VRS VRS 3-Dec-2020
Tamilnadu, India 0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: PEMEX, Maxico Project Ref. No.: X-45181
1 Valve ID 7 SELECTION SUMMARY
2 Tag No. 45181A-PSV-101 A/B 8 Valve Model No. 1E2 JBS-E-35-K-SPL
3 Service 1st Stage Discharge 9 Brand Crosby®
4 PID No. 10 CONNECTIONS
5 Line No. Quantity 11 Inlet 1" Flngd. 300# RF Standard
6 D-R Mat Code WIN51645ABBT1 8 12 Outlet 2" Flngd. 150# RF ASME B16.5
Wt.= 36 lb = 16.33 kg
A= 4.13 in = 104.90 mm
B= 4.50 in = 114.30 mm
C= 20.25 in = 514.35 mm
D= 1.56 in = 39.62 mm
E= =
F= =
G= =
H= =
Dimension Notes
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Sizing & Selection Report
(formerly Pentair Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
(Formerly Tyco Sanmar Ltd) 1 VRS VRS VRS 3-Dec-2020
Tamilnadu, India 0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: PEMEX, Maxico Project Ref. No.: X-45181
1 Valve ID 41 SIZING DATA
2 Tag No. 45181A-PSV-102 A/B 42 Design Code ASME Section VIII Sizing Std. API 520
3 Service 2nd Stage Discharge 43 Sizing Basis Blocked Discharge
4 PID No. 44 Fluid State at Inlet Gas / Vapor
5 Line No. Quantity 45 Relieving Case Pressure Relief
6 D-R Mat Code WIN51645ABBT2 8 46 Fluid Properties
7 GENERAL 47 Fluid Name Naptha
8 Valve Type Balanced Bellows, Direct Spring-Operated 48 Molecular Weight, M 2.03
9 Safety / Relief Safety Balanced Yes 49 Compressibility, Z 1.040
10 Nozzle Full Bonnet Vented 50 Ratio of Sp. Heats, k (Cp / Cv) 1.417
11 CONNECTIONS 51 Gas Constant, C 357.6
12 Inlet 1" Flngd. 600# RTJ Standard 52
13 Outlet 2" Flngd. 150# RF ASME B16.5 53
14 MATERIALS OF CONSTRUCTION 54
15 Body Killed CS SA216-WCB 55
16 Bonnet Killed CS SA216-WCB 56
17 Nozzle 316 SST 57
18 Disc 316 SST 58
19 Seat 316 SST 59 Sizing Coefficients Unit -
20 Spindle 316 SST 60 Effective K, Gas 0.975
21 Guide SS A297 Gr. HE 61 Kb Kc 1 1
22 Spring Chrome Steel 62
23 Gaskets 316 SST 63
24 Bellows 316L SST 64 Required Capacity Unit kg/hr
25 Cap Type Screwed w/ Test Rod 65 Total 1000.86
26 NACE MR0175/ISO 15156:2015 No 66
Accessories
mm
16.33
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Calculation Report
(formerly Pentair Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
(Formerly Tyco Sanmar Ltd) 1 VRS VRS VRS 3-Dec-2020
Tamilnadu, India 0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: PEMEX, Maxico Project Ref. No.: X-45181
1 VALVE ID 11 CALCULATION NOTES
2 Tag No. 45181A-PSV-102 A/B 12
3 Valve Model No. 1D2 JBS-E-45-K-SPL Qty. 8 13
4 SIZING DATA 14
5 Design Code ASME Section VIII Sizing Std. API 520 15
6 Fluid State at Inlet Gas / Vapor 16
7 CALCULATION SUMMARY
8 Required 1000.86 kg/hr 18 Required 0.560 cm²
Flow Area
9 Maximum 1268.293 kg/hr 19 Selected 0.710 cm²
10 Reaction Force, Open Discharge 63.4 kgf 20 Noise Level (db), Open Discharge 146.5 at 1 m
Variable Type Variable Name Symbol Input Value Equation Value
Fluid Properties Molecular Weight M 2.03 2.03
Ratio of Specific Heats k 1.417 1.417
Compressibility Z 1.040 1.040
Process Cond. Required Mass Flow Wreq 1000.86 kg/hr 2206.519 lb/hr
Set Pressure Pset 85.7 kg/cm² g 1218.941 psig
Over Pressure Pover 8.57 kg/cm² g 121.894 psig
Inlet Line Loss Ploss 0 kg/cm² g 0 psig
Back Pressure Pback 2.1 kg/cm² g 29.869 psig
Atmospheric Pressure Patm 1.033 kg/cm² a 14.696 psia
Relieving Temperature T 101.47 °C 674.316 °R
Distance from Valve (noise) r 1m 3.2808 ft
Rupture Disc CCF Kc 1 1
Valve Data Discharge Coefficient (API) K,API 0.975 0.975
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Calculation Report
(formerly Pentair Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
(Formerly Tyco Sanmar Ltd) 1 VRS VRS VRS 3-Dec-2020
Tamilnadu, India 0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: PEMEX, Maxico Project Ref. No.: X-45181
1 VALVE ID 11 CALCULATION NOTES
2 Tag No. 45181A-PSV-102 A/B 12
3 Valve Model No. 1D2 JBS-E-45-K-SPL Qty. 8 13
4 SIZING DATA 14
5 Design Code ASME Section VIII Sizing Std. API 520 15
6 Fluid State at Inlet Gas / Vapor 16
7 CALCULATION SUMMARY
8 Required 1000.86 kg/hr 18 Required 0.560 cm²
Flow Area
9 Maximum 1268.293 kg/hr 19 Selected 0.710 cm²
10 Reaction Force, Open Discharge 63.4 kgf 20 Noise Level (db), Open Discharge 146.5 at 1 m
Calculate Noise Level at 100-ft (30-m) L100 116.8 db
L100 = [6.5 * log( 1/PR ) + 51.28] + [10 * log(0.29354 * W * k * T / M)]
Calculate Reaction Force for Open Discharge Fr 63.4 kgf 139.7 lbf
Ao = (π * Do^2) / 4
Fr = (A * C * K,API * P1 * Kc / 366) * {k / [(k + 1) * Z]}^0.5 + (Ao * Po)
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright © 2020 Emerson Electric Co.
AGC Sanmar Limited Pressure Relief Valve Dimensional Drawing
(formerly Pentair Sanmar Ltd) 2 VRS VRS VRS 29-Jan-2021
(Formerly Tyco Sanmar Ltd) 1 VRS VRS VRS 3-Dec-2020
Tamilnadu, India 0 VRS VRS VRS 6-Nov-2020
vrs1@sanmargroup.com
Quote Number: 380760.010 No Prpd. Chk. Appr. Date Revision
Client: Dresser Rand India Pvt Ltd
Location: Ahmedabad End-User Ref. No.:
Project: PEMEX, Maxico Project Ref. No.: X-45181
1 Valve ID 7 SELECTION SUMMARY
2 Tag No. 45181A-PSV-102 A/B 8 Valve Model No. 1D2 JBS-E-45-K-SPL
3 Service 2nd Stage Discharge 9 Brand Crosby®
4 PID No. 10 CONNECTIONS
5 Line No. Quantity 11 Inlet 1" Flngd. 600# RTJ Standard
6 D-R Mat Code WIN51645ABBT2 8 12 Outlet 2" Flngd. 150# RF ASME B16.5
Wt.= 36 lb = 16.33 kg
A= 4.13 in = 104.90 mm
B= 4.50 in = 114.30 mm
C= 20.25 in = 514.35 mm
D= 1.56 in = 39.62 mm
E= =
F= =
G= =
H= =
Dimension Notes