Gmo-A01-00-30

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

Pump unit

GMO-A

Illustration shows example

Use:
As pump unit in central lubrication systems

+ for the delivery of oil, liquid grease or


grease
+ 1 to 3 pump elements
+ up to 44 outlets with progressive dis-
tributors flanged-on
+ electric control and monitoring
+ Two lubrication circuits separately
controllable
+ WOERNER Easy Lock eccentric
with simple and safe installation of
the positively driven pump elements
and additional Lube Care function
- Subject to modifications -

(agitation without conveying)


+ Control with intelligent error output
+ Optionally with integrated heating
and temperature monitoring
+ Wide range of reservoir and monitor-
ing options

Technical data:
Delivery pressure: 350 bar
Number of pump elements: max. 3
Delivery volume per stroke and element *
with pump element 11: 0,11 cm³
Temperature range: -20 ... +60 °C *
Mounting position: vertically *
Weight (without reservoir): 5 kg
Material
Casing: Aluminium
Pump element: Steel
Reservoir: see page 4
Gaskets: NBR
Medium contacting parts: FPM
Medium: Oil and grease
up to NLGI class 2 *
Mains voltage: 24 VDC *
Power consumption: max. 72 W
Speed (load-dependent): approx. 30 min-1
Protection class
(without reservoir): DIN EN 60529
IP66/69

* others on request
Illustration shows examples

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904.07.23 EN
Hafenstraße 2 DE-97877 Wertheim Replaces P0904.05.23 EN
( +49 9342 803-0 Page 1 of 15
info@woerner.de www.woerner.de
Order designation:
GMO-A 01 00 30 KK A 11 11 11 0 0 D11 0 0
internal

Pump Connection
3)
Filling element possibility Electric Drive Operating
Reservoir Level monitoring at pos. 7)
connection at pos. control monitoring temperature
1 2 3 1 3
see page 4 see page 5 + 6 see page 7 see page 7 see page 7 + 8 see page 9 - 11 see page 12 see page 12

Polyamide for oil:


1) with
min. level monitoring
2l Directional D22
F 4)
2 control valve
(all reservoirs) up to 350 bar
4l without
for grease: V...
4P
Intermittent 0 Monitoring
A
min. level monitoring T
Polyester C
0,11 cm³ with
5l (all reservoirs) for VPB-SSV
11 A
5 up to 350 bar
for grease with
2) S...
10 l follow-up piston C with

- Subject to modificationsn -
10 Ultrasonic D11
30 l AK / DK
8)
30 KFA-A
KK for VPB-B Monitoring
D or VPB-G and heating
5)
stainless up to 150 bar with H
steel Ultrasonic
G... D12
A / D
4l
8)
4V KFA-A
only oil
7l G
7V K 6)
for pressure with
without limitation D13 without
25 l without
0 pump element 0
25V 0 up to 350 bar
B... without
Min. 0 0
1 without
Adapter 0
Min. + pre-warning
KX
2
KX without
without 0
0

1) 4) 6)
With level monitoring "F", lubricant cannot In combination with control only one di- Evaluation level monitoring only minimum
be stirred. rectional control valve is possible. (exception "AK" / "A").
2) 5) 7)
Only with polyester reservoir. Evaluation level monitoring only prewarn- Only possible with control.
3) 8)
Pressure ranges see page 8. ing and minimum (exception "AK" / "A"). Also available in stainless steel on request.
see data sheet P0520

Order example:
Pump unit GMO-A with reservoir polyamide 4 l, with level monitoring "C", with filling connection "G", pump element 11 at position 1, with
connection possibility for VPB-SSV and directional control valve 250 bar at position 1, with electric control "D11", with drive monitoring "A",
without operating temperature monitoring.
Order designation: GMO-A01 / 00 / 4P / C / G / 11 / 0 / 0 / S250 / 0 / D11 / A / 0

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 2 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Functional description:
The pump unit GMO-A is driven by a gear
motor 5 flanged to the pump casing 4
from downside. When the eccentric shaft
3 rotates, the delivery piston 2.1 of every
pump element performs a suction and de-
livery stroke per rotation each, whilst deliv-
ering lubricant from the reservoir 1 to the
1 lubrication points.

WOERNER Easy Lock eccentric


with Lube Care:
The pump unit GMO-A has a specially de-
signed WOERNER Easy Lock eccentric,
which guarantees simple and safe instal-
2.1 lation of the positively driven pump ele-
ments. For assembly, the pump elements
are simply screwed in and then hook in
automatically with the first eccentric rota-
tion. Furthermore, the Lube Care function
enables an improvement of the lubricant
3 quality and the pumping behaviour by reg-
ular agitation of the lubricant. When the
4 eccentric shaft 3 rotates into the one di-
rection of rotation, the pump elements are
operating while the stirring device supplies
them with the lubricant. As soon as the
eccentric shaft 3 starts to rotate into the
- Subject to modifications -

other direction, the lubricant is stirred with-


5 out any delivery operation by the pump
elements taking place.
The integrated control allows operating and
off-duty periods for both the delivery with
and without stirring (Lube care) to be pro-
grammed independently from each other.

Dimensions:

Dimensions of the reservoirs and the various attachments are listed on the following pages.

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 3 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Reservoir versions:
4P Reservoirs "2" and "4P" 2 4P
Materials
Reservoir polyamide Reservoir: Polyamide translucent
2
"2" and "4P": Cover: Polypropylene
Weight without monitoring
"2": 0,3 kg
Reservoir capacity: 2l
"4P": 0,4 kg
Reservoir capacity: 4l
Filling level visually visible!

Reservoirs "5", "10", "30" 5 10 30


Materials
Reservoir: Polyester/aluminium
30
Cover: Aluminium
Reservoir polyester Follow-up piston (optional): Aluminium
"5", "10", "30": 10 Weight without monitoring
"5": 1,5 kg
Reservoir capacity: 5l
"10": 1,95 kg
Reservoir capacity: 10 l
"30": 4 kg
Reservoir capacity: 30 l
5 Weight follow-up piston
without monitoring

- Subject to modificationsn -
for reservoir 5 and 10: 0,8 kg
for reservoir 30: 2,7 kg
Filling level visually visible!

If a follower piston is used, the usable vol-


ume is reduced at:
"5" and "10" by approx. 2,5 l
"30" by approx. 6 l

Reservoirs "4V", "7V", "25V" 4V 7V 25V


Materials
25V Reservoir: stainless steel
Cover: stainless steel
Reservoir stainless steel "4V": 1,5 kg
"4V", "7V", "25V": Reservoir capacity: 4l
7V "7V": 2,5 kg
Reservoir capacity: 7l
"25V": 4,6 kg
Reservoir capacity: 25 l
4V
KX see data sheet P0915

A A1 A2 H
Reservoir
mm mm mm mm
2 282 317 334 129
4P 329 364 381 176
5 377 434 435 224
10 557 614 615 404
Dimension A = Reservoir without KFA or Ultrasonic 30 637 694 695 482
Dimension A1 = Reservoir with monitoring KFA-A
4V 325 385 368 171
Dimension A2 = Reservoir with monitoring Ultrasonic
Dimension H = Reservoir height 7V 423 483 466 270
25V 540 600 583 386

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 4 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Level monitoring:
Simple minimum controls:

Level control "C": C


Lubricant available No lubricant available
min. level monitoring
(permanent signal) (intermittent signal)
for liquid grease NLGI class 000
up to grease NLGI class 2

When the reservoir is empty and the pump


drive shaft is rotating, an intermittent empty
signal is output by a movable deflector.

Level control "F": F


min. level monitoring for oil

When the reservoir is empty, the float sinks


and a continuous empty signal is emitted.
- Subject to modifications -

Level monitoring with ultrasonic sensor:

Distance measurement of the level by re- Level control "D" / "DK": D DK Level control "A" / "AK": A AK
flection of the medium surface. Ultrasonic sensor digital Ultrasonic sensor analog
with two switching points for oil and grease
When checking the level of grease, the for oil and grease
use of a follower piston is strongly rec- For version with control, 3 switching points
ommended. are freely selectable.

For more information see P0920.


Technical data: Technical data:
Version digital Version analog

Operating voltage: 10 ... 30 VDC Operating voltage: 10 ... 30 VDC


Output type: NC Output type: 4 ... 20 mA
Output current: max. 100 mA Output current: –
Housing material: PBT / AlSI 316L Housing material: PBT / AlSI 316L
(DIN 1.4404) (DIN 1.4404)
Weight: 100 g Weight: 100 g
SP1: Reservoir empty
SP2: Reservoir at approx. 25%
residual volume

Connection BN/1
+
Connection BN/1
+
diagram: BU/3 diagram: BU/3
- -

SP1
SP2
BK/4 BK/4
4-20 mA
Illustration shows examples WH/2 WH/2
N.C.

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 5 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Level monitoring KK K
Level control KFA-A with level switch KFA:
without follow-up piston K
The level monitoring system with level
switch KFA offers up to three switching
points depending on the reservoir.
When using with grease, a follower piston
must be used.

Float atop
(full reservoir)

Electrical data:

Float at approx. Switching capacity: max. 30 W


25% residual Switching voltage: max. 30 VDC
useful volume Switching current: max. 0,5 A
For inductive an capacitive loads, sup-
pressor circuits shall be provided for.
Float on bottom (Diode, RC element, varistor)
(empty reservoir) Protection class: DIN EN 60529 IP65
Connection type: Male M12x1, 5-pin
Weight: 0,15 ... 0,18 kg

- Subject to modificationsn -
Connection
diagram:

Level control KFA-A


with follow-up piston KK
see data sheet P0496

Also available on request with KFA-V


completely stainless steel.
see data sheet P0520

Follow-up piston
atop
(full reservoir)

Follow-up piston at
approx. 25% residual
useful volume
Follow-up piston
on bottom
(empty reservoir)

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 6 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Filling connector:
1)
Filling connector "A" A
1)
Filling connector "C" C Technical data:
Cone lubricator nipple DIN 71412 - AG1/4 Flat lubricator nipple DIN 3404 - M22 Material
Filling connector "A": Steel
A C Filling connector "C": Steel / Cu
Filling connector "D": Steel / Cu
Filling connector "G": CuZn / Cu

Suitable counterparts see accessories.


Other filling connection variants are avail-
able on request.

1)
not suitable for oil

Filling connector "D" D Filling connector "G" G


Closing nipple DN 6 with dust cap Closing nipple DN 7 with dust cap

D G
- Subject to modifications -

Attachment and connection options:


Pump elements:

Up to 3 pump elements can be mounted


on the GMO-A pump unit. The position of
the pump elements is indicated with posi-
tion 1-3. Pump element connections not
required are closed with screw plugs. For
easy combining of the pump elements, cor-
responding screw connection sets can be
Pump element Pump element found in the accessories.
at position 1 at position 3
Attachment B... Attachment B...
G... G...
S... S...
V... V...
Pump element at position 2

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 7 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Connection option Pressure limitation:
for progressive distributor:

WOERNER progressive distributors can All attachment blocks (V + S + G + B) have


be directly flanged to the pump elements an integrated pressure limiter, which
at position 1 and 3. Progressive distributors automatically returns the medium to the
with up to 22 positions each and different reservoir when the maximum pressure is
feed volumes are possible. reached. The maximum delivery pressure
can also be set subsequently by inserting
different valve cartridges. The following
valve cartridges are available:

(without pressure limitation) 0 bar


Technical data: 50 bar
70 bar
Weight per 100 bar
Attachment "B": 0,5 kg 150 bar
Attachment "G" and "S": 0,6 kg 200 bar
Attachment "V": 1,1 kg 250 bar
300 bar
350 bar

Other opening pressures on request or:

HDP-A see data sheet P0925

Directional V...
control valve "V":

- Subject to modificationsn -
2
1

A directional control valve with inte- Technical data:


grated pressure relief valve, optionally up
to 350 bar, can be flanged directly to pump Nominal voltage: 24 VDC
element position 1. Nominal current: 1,25 A
In conjunction with the D22 control unit, Energized duty rating: 100%
2 separate lubrication circuits can be Protection class: DIN EN 60529 IP65
controlled and 2 progressive distributors Connection type: Male
directly monitored. DIN EN 175301-803, shape A

Connection "B": B... Connection "G" G...


for VPB-B or VPB-G
With internal pressure relief valve for pump
elements. Connection "S" for VPB-SSV: S...
Opening pressure pressure relief valve op-
tionally up to 350 bar.

6
The following progressive distributors can
be flanged on:

Connection "S": S...


VPB-SSV see data sheet P0888

Connection "G": G...


VPB-B see data sheet P0378
VPB-G see data sheet P0177

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 8 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Electrical control:
Version with control: D11 D12 D13 D22
Technical data:

The control is used for monitoring and ac- Various commands (e. g. enable, acknowl- Power consumption standby: 0,5 W
tuating the pump unit. It is able to switch edge fault, input block ...) and status mes- Power consumption typical: * 30,0 W
the pump on and off both depending on time sages (alarm, warning, detailed error mes- Power consumption: max. 67,5 / 96 W
and load. In addition, the control can mon- sage ...) are exchanged via continuous (D22 control)
itor the filling level, the drive motor, the signals or pulse trains. Nominal voltage: 24 VDC
function of the progressive distributors and Supply voltage: 11 ... 27 VDC
the medium temperature. Furthermore, the Input voltage: 11 ... 27 VDC
control is able to switch the optionally in- Output
stalled heating on and off. As an interface to alarm / lubrication: max. 200 mA
a higher-level system, the control has one Further information, notes and application 24 VDC / 5 W
input (wiring is mandatory) and 2 outputs. examples are listed in the operating instruc-
tions. The outputs are short-circuit proof.

see B0904
* Power consumption depends on temper-
ature and medium.

Version "D11": D11 Version "D12": D12 Version "D13": D13

Possibility of monitoring 1 progressive dis- Possibility of monitoring 2 progressive dis- Possibility of monitoring 3 progressive dis-
tributor: tributors: tributors:
Distributor 1 = Master Distributor 1 = Master Distributor 1 = Master
(Stop conveying in pulse mode) (Stop conveying in pulse mode) (Stop conveying in pulse mode)
- Subject to modifications -

Distributor 2 = Slave Distributor 2 and 3 = Slave


(Monitoring the circulation) (Monitoring the circulation)

8.3 8.3 8.3

8 8.1 8 8.1 8 8.1

Version "D22": D22

For controlling 2 lubrication circuits via the


directional control valve V and monitoring
2 progressive distributors:
Distributor 1 and 2 = Master
(Stop conveying in pulse mode)
Electric connection 8: Electric connection 8.3:
Connection type: Male Connection type: Cable gland
M12x1, 5-pin for level control

8.2 Electric connection 8.1 and 8.2:


8.1 Connection type: Female
M12x1, 4-pin
(For the connecting cables required see the
8 accessories on page 14)

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 9 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Connection diagram for version with control:

8.1
GMO-A Distributor 1-3
8 24 VDC 1
Customer 4 I
BN 1 24 VDC
+24 VDC 0 VDC 3 NO
WH 2 24 VDC (Input)

3 24 VDC 4
BU 0 VDC
0 VDC
4 0 VDC 3
BK 24 VDC (Output 1)

5 8.2 Directional
GY 24 VDC (Output 2)
Heating relief valve

PT100

4-20mA
L3

L2
M
8.3 L1
Motor Level 1 Level 2 Level 3 Level 4
control

Choice of level 1-4

- Subject to modificationsn -
Input:

Control signal at Pin 2 (no alarm → Pin 4 = 1 or pulse 1 Hz)


Signal length Function Operating mode
External release → Pump runs the cycle
>1000 ms Time
according to the entered parameters
Pulses External signals → Summation of the external pulses
Pulse
Pulses External signals → Summation of the external pulses
>1000 ms when the lock function is activated

Time
3 pulses 1 Hz Locking or unlocking the key functions
Pulse (must be activated in the settings)

Control signal at pin 2 (alarm → Pin 4 = 0)


Signal length Function Operating mode
Time
Pulse Acknowledgement of the fault
Pulse

Output 1: Output 2:

Alarm signal at Pin 4 Output at Pin 5 (no alarm → Pin 4 = 1 or pulse 1 Hz)
Signal Description Signal Description

1 (duration) no alarm 1 (duration) Conveying active

Pulse 1 Hz Warning Output at Pin 5 (alarm → Pin 4 = 0)

Alarm → detailed error output Signal Description


0 (duration)
via pin 5 or on the display Number of signals per 30 seconds →
1 Hz
detailed error output

For more detailed information, please refer to B0904.

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 10 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Version without control: 0
Output level monitoring:

Evaluation according to type. See chapter


level monitoring.

Switching current: max. 200 mA


Switching function: NC contact

Connection diagram for version without control:


Technical data:

Power consumption typical: * 30,0 W 8


Power consumption: max. 60 W Customer GMO-A
Nominal voltage: 24 VDC BN 1 24 VDC
Supply voltage: 11 ... 27 VDC +24 VDC
Input voltage: 11 ... 27 VDC WH 2 24 VDC (Stirring)

The outputs are short-circuit proof. BU 3 0 VDC


0 VDC
- Subject to modifications -

BK 4 24 VDC (Level mon-


1)
itoring)
GY 5 24 VDC (Motor mon-
1)
* Power consumption depends on temper- itoring)
ature and medium.

M
1)
Level and motor monitoring Motor Level
only active when the motor monitoring monitoring
is running. (optional)

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 11 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Additional functions:
Operating temperature: T H Drive monitoring: A

When selecting "T" or "H" When the eccentric shaft rotates, an opener
(only in combination with control): signal is output per full revolution.
In combination with the control, actuation
The temperature monitoring or heating is via eccentric rotations and thus precise and
integrated in the pump housing. If "T" is time-independent dosing of the pump ele-
selected, the operation of the pump is ments is possible.
monitored in an adjustable temperature In addition, the duration of one revolution is
range and the temperature is displayed. monitored.
If "H" is selected, the functions of "T" are
supplemented by a heating element which Switching current: max. 200 mA
heats the medium in the suction area of Switching function: NC contact
the pump.

Accessories: (please order no. specify)


Pressure relief cartridges
Pressure relief valve 9.1: Order no.

- Subject to modificationsn -
0 bar 112.734-65K
50 bar 112.738-68K
70 bar 112.738-64
100 bar 112.736-69K
150 bar 112.736-64
200 bar 112.737-68K
250 bar 112.737-64
300 bar 112.735-64
350 bar 112.735-69K

Screwing kit 9.2: Order no.

9.1 9.2 112.758-64

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 12 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Pressure relief
Pressure relief valve at the pump element:

For operating pressure delimitation, pressure relief valves 10 can be connected to the pump
element.
10
Pressure relief valve 10 Screwing kit 10.1
10.1 for pipe ø8 for pipe outlet
with opening pressure: Order no. (compatible for pressure
relief valve 10) Order no.
70 bar 112.470-65
150 bar 112.472-65 ø6 112.750-65
250 bar 112.473-65 ø8 112.751-65
300 bar 112.469-67 ø10 112.752-65
350 bar 112.469-65

Customised setting:

50 ... 160 bar 112.474-65


160 ... 300 bar 112.475-65

Piping

without attachment: with attachment:


- Subject to modifications -

11.1 11.3
11.3
11.1
11.1 11.3 11.1 11.3 11.7
11.2
11.1
11.3

11.7
11.5 11.4
11.5
11.5
11.4 11.2
11.7

11.5 11.1 11.8 11.6 11.1 11.1 11.5 11.1

Screwing material Order no. The outlets of the pump unit can be com-
bined in a simple manner using the listed
11.1 Screw-in socket pipe and fitting sets. When ordering, it is
LR-10R 951.900-03 necessary to specify which jobs will be
11.2 T-fitting combined and where exactly the feeder(s)
L-T 10 950.400-13 will be placed. In addition to external outlets
11.3 Angle screw connection (see first figure "without attachment" 11.2),
L-W 10 950.300-13 internal outlets to the various attachment
11.4 Cross screw connection blocks are also possible (see second figure
L-K 10 950.500-13 "with attachment" 11.3). If two pump ele-
11.5 Pipe, pump element ments are to be combined, they must be
to pump element 112.720-45 mounted at adjacent positions (position 1
11.6 Pipe, attachment and 2 or position 2 and 3).
to pump element 112.720-46 The piping listed here builds up both later-
11.7 Angle screw connection ally and to the front by approx. 54 mm to the
EVW 10 952.512-10 front.
11.8 Screw connection kit
Filling connection 112.720-61

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 13 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Accessories for filling connectors: Mounting accessories:

for filling connector "G": G for filling connector "C": C Mounting bracket for floor mounting with
mounting material for pump.
Locking coupling Sliding coupling
(pmax = 35 bar) Connection thread G 1/8
Connection thread G 1/4i

Order no. 954.002-09 Order no. 949.401-05

for filling connector "A": A for filling connector "D": D

4-jaw hydraulic Locking coupling


clutch (pmax = 200 bar)
Connection
thread M10x1

Connection thread G 1/4i


Order no. 954.004-56 Order no. 954.000-20

Connection thread G 3/8i


Order no. 954.000-14 Order no. 112.757-64

- Subject to modificationsn -
Connecting cable Connection cable Power pack
for power supply: for electrical function monitoring for version with control
progressive distributor to the control: (optional):

Operating voltage: 10 ... 30 VDC Operating voltage: max. 30 VDC Order no.
Cable diameter: 5x0,34 mm2 Cable diameter: 4x0,34 mm² Power pack
Protection class: DIN EN 60529 IP67 Protection class: DIN EN 60529 IP67 100-240 VAC / 50-60 Hz: 470.218-74
Connection type: Female Connection type: Male/Female
M12x1, 5-pin, 0° both-sided M12x1, 4-pin
see data sheet P0537

Order no. Order no.

Cable length 5 m: 913.406-13 Cable length 0,2 m: 913.405-71


Cable length 10 m: 913.406-14 Cable length 0,6 m: 913.405-23
Cable length 15 m: 913.406-15 Cable length 2 m: 913.405-06
Cable length 5 m: 913.405-50

(other cable lengths available on request)

Technical documents also valid for this product:

B0904 EN Operating instruction GMO-A

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 14 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de
Important information about this data sheet

Reproduction, also in extracts, only permitted with the approval of the firm of EUGEN
WOERNER GmbH & Co. KG.

All the information in this data sheet has been examined for correctness with great care.
Nevertheless, WOERNER cannot assume any liability for losses or damage resulting
directly or indirectly from the application of the information contained in this data sheet.

All products from WOERNER may only be used as intended and corresponding to the
information in this data sheet.
For products supplied with operating instructions, the additional directives and informa-
tion contained in them are to be complied with.

Materials deviating from those mentioned in this data sheet and the technical documents
which further apply may only be poured into and processed in the appliances and systems
manufactured and supplied by WOERNER by following agreement with and written
approval by WOERNER.
The safety and danger information stated in the safety data sheets of the substances
used must be taken into account at all costs.

Transportation of gases, liquefied gases, gases under pressure, vapours and liquids, the
vapour pressure of which is more than 0,5 bar above normal atmospheric pressure
(1013 mbar) at the maximum admissible temperature, of easy inflammable or explosive
media as well as transportation of foodstuffs is forbidden.
- Subject to modifications -

Information on EU Directive 2011/65/EU (RoHS)

In its controls and switching devices, WOERNER only uses materials which fulfil the
criteria of EU Directive 2011/65/EU. To the extent that hexavalent chromium has been
used as corrosion protection in the parts which we produce ourselves, it has already been
replaced by other environmentally tolerable protective measures.

The mechanical devices supplied by WOERNER are not affected by EU Directive


2011/65/EU.

But as WOERNER is conscious of its responsibility towards the environment, we shall


also use materials fulfilling the requirements of the Directive for devices not covered by
EU Directive 2011/65/EU as soon as they are generally available and their use is
technically possible.

Pump unit GMO-A EUGEN WOERNER GmbH & Co. KG Data sheet P0904 EN
Hafenstraße 2 DE-97877 Wertheim Page 15 of 15
( +49 9342 803-0
info@woerner.de www.woerner.de

You might also like