GENERAL KEY PLAN: N

Wa
B01

reh
o
use

LA
QIB
9359
9358

BB 9357
9314

9313

9356 9312

301010 9355

A B 9354 9311

B0
2
9310

9309
9353 9308
9307

9306

9352
9305

6100 9351

9350
9304

9303

3050 3050
5mm JOINT 9345

9344

fue
3051751117.01

l are
9343

a
9342
9290

1016 1018 1016 1016 1018 1016 9341

B0
4
To
we
r
an
9340

dmo
9339 9286

un
9338

d to

WA WER
TO in
rem
9337

TER
1

a
Mis

Mis
c st

c st
ora

OO RAG
OO ORAG
9336

STO

ora
ST
ge

GC E
GC E
200

ge
AR
OO
AR

GO

B0
GO

Ga

5
rea
TUBE 80x40x1.5 TUBE 80x40x1.5 9335

B0
3

B0
9334

7
B0
6
9639

400
DETAIL-1 9333

9332

9331

9330

BOTTM CHORD 80 x 40 x 1.5

BOTTM CHORD 80 x 40 x 1.5

BOTTM CHORD 80 x 40 x 1.5

BOTTM CHORD 80 x 40 x 1.5


9329

9328

400
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS, ALL DIMENSIONS SHOULD BE VERIFIED
ON SITE AND APPROVED BY THE ENGINEER.

400
2. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, ROADS,
PURLINS 40x20x1.5 PURLINS 40x20x1.5
3000 INFRASTRUCTURE AND SPECIAL SYSTEMS DRAWINGS AND ALL ELECTRICAL
AND SPECIAL SYSTEMS DRAWINGS AND ALL RELEVANT SECTIONS OF THE
400 SPECIFICATIONS.
3. THE FABRICATION AND ERECTION OF STEEL STRUCTURE SHALL BE AS PER
AISC MANUAL.
4. UNLESS OTHERWISE INDICATED,LEVELS ARE IN METERS (m) AND ANGLES ARE
AA AA IN DEGREES.
400

301010 301010 5. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS SHOULD BE


FOLLOWED.
6. STRUCTURAL STEEL SHALL CONFIRM TO THE REQUIREMENTS OF ASTM A36 FOR
W SECTIONS AND A500 GRADE A FOR TUBES.
7. E60 ELECTRODE SHALL BE USED FOR WELDING PURPOSE AND CONNECTION
400

DESIGN IS ALSO BASED ON E60 ELECTRODE.


6000

8. ALL CUTTING, FABRICATION AND WELDING SHALL BE CARRIED OUT AT


WORKSHOP AND WILL NOT BE PERMITTED AT SITE.
9. WELDING SHALL CONFORM TO COMPANY ENGINEERING STANDARDS.WELDING
400

SHALL COMPLY WITH ANSI/ AWS D 1-1.


10. ALL INTERNAL STRUCTURAL MEMBERS TO BE COATED WITH SUITABLE
PURLINS 40x20x1.5 PURLINS 40x20x1.5
2 PAINTING SYSTEM TO COMPLY WITH CORROSIVITY CATEGORY ISO 12944-5:
(2018) C3 (H).
11. ALL EXTERNAL STRUCTURAL MEMBERS TO BE COATED WITH SUITABLE
400

PAINTING SYSTEM TO COMPLY WITH CORROSIVITY CATEGORY ISO 12944-5:


(2018) C5 (LOW)
BOTTM CHORD 80 x 40 x 1.5

BOTTM CHORD 80 x 40 x 1.5

BOTTM CHORD 80 x 40 x 1.5

BOTTM CHORD 80 x 40 x 1.5


400

02 18-04-2023 IFC STAGE (3D) AHM


400

01 23-03-2023 IFC STAGE (3D) AHM


Rev. Date Reason For Issue Checked By
400
3000

PURLINS 40x20x1.5 PURLINS 40x20x1.5 PURPOSE OF ISSUE:


3D - IFC PACKAGE
400

CLIENT: PROJECT MANAGEMENT CONSULTANT:


400
400

TUBE 80x40x1.5
200

TUBE 80x40x1.5 DESIGN CONSULTANT : EPC CONTRACTOR:

BB SUB CONTRACTOR:
301010
M 16 BOLT

25
DESIGN CONSULTANT / CONTRACTOR: NEOM'S REVIEW:

50
40x40x3
1 BOTTOM CHORD LAYOUT (BOTTOM OF STEEL +3.460) ANGLE SECTION DRAWN: M.AT 18-04-2023

25
5mm JOINT
CHECKED: AW 18-04-2023 CHECKED:
101050

2000mm (TYP.)
SCALE 1:25MTS
APPROVED: FA 18-04-2023 APPROVED:

SCALE: AS SHOWN SHEET SIZE: A1


BUILDING NAME:
M 16 BOLT B01-GUARD HOUSE

25
BOTTOM CHORD
TUBE 80x40x1.5
DISCIPLINE NAME:

50
40x40x3
ANGLE SECTION
STRUCTURAL

25
BOTTOM CHORD DRAWING NAME:
TUBE 80x40x1.5
BOTTOM VIEW
BOTTOM CHORD LAYOUT PLAN
PROJECT NAME:
TUBE 80x40x1.5
LEGEND
DESIGN OF FACILITIES FOR TERMINAL - T 0
COLUM 80x80x1.5

TYP
1.5 3mm MS PLATE
40x40x3 CONTAINER ACTIVATION NEOM, SAUDI ARABIA
ANGLE SECTION
M 16 BOLT
S/NO NAME SYMBOLS SIZE
5mm JOINT NEOM Industrial City
01 STEEL TUBE 40x20x1.5 NEOM
02 STEEL TUBE 80x40x1.5 BOTTOM CHORD KINGDOM OF SAUDI ARABIA
1.5 TUBE 80x40x1.5
TYP REGION ASSET CODE CONTRACT CODE
03 STEEL TUBE 80x40x1.5 DETAIL -1
SIDE VIEW
SCALE 1:10 03 120000 4800000441
STEEL TO STEEL CABIN CONNECTION DETAIL DRAWING NUMBER
SCALE 1:10
ORIGINATOR DISCIPLINE DOCUMENT TYPE SEQUENTIAL NUMBER REV NO.

BOC STR DRG 101050 02