RMS Configuration to NOC/FS

and TM

Private & Confidential


Helios Towers | Private & Confidential

Introduction
This presentation covers the

all processes and

procedures for RMS

installation and 1.Initial installation

maintenance.

2. During Generator swap 3. During Rectifier swap

2
Helios Towers | Private & Confidential

Teltonika Configuration
Major Tools required

Tools & Equipment Required


In addition to the Standard Tool Kit the following material are required.
Power Supply
12 or 24VDC Power Supply
2 Way Terminal Block
❑ Multimeter
Laptop
Laptop with Ethernet/RJ45 connection port.
Lan Cable with RJ45 plug on either end (2m long).

3
Helios Towers | Private & Confidential

Teltonika Configuration
Cables information

Cables

Comm Controller Cable Cable length


TCP Rectifier Controller CAT5 2m
RS232 Deepsea D9 to D9 Straight M/F 15m
RS485 Deepsea CAT5 15m

4
Helios Towers | Private & Confidential

Teltonika Layout
Layout Panel 1

5
Helios Towers | Private & Confidential

Teltonika Layout
Layout Panel 2

6
Helios Towers | Private & Confidential

Hardware installation
1. Locate and secure the RUT955 in the rectifier cabinet in a location which is not subjected with
direct temperature rise and has space for suitable installation. See below Images
2. Insert the SIM card(s) and SD Card as appropriate.
3. Attach Mobile Antenna Position 3 and other antennas as appropriate.
4. Install the 12 or 24VDC Power Supply to the RUT955

7
Helios Towers | Private & Confidential

Hardware installation
1. Locate and secure the RUT955 in the rectifier cabinet in a convenient location for cable
access.
2. Insert the SIM card(s) and SD Card as appropriate.
3. Attach Mobile Antenna Position 3 and other antennas as appropriate.
4. Install the 12 or 24VDC Power Supply to the RUT955

8
Helios Towers | Private & Confidential

Connection status LED indication


Once the device is powered below observations should be considered
Constant blinking (2Hz) – router is turning on.
Data not connected– it has no data connection; LED will be Red. see Fig 1
Data connected – it has data connection; all the LED will be Green without blinking. see Fig 2
Explanation of connection status LED indication:
Fig 1 Fig 2

9
Helios Towers | Private & Confidential

Controller configuration
Modbus TCP Connections
The three LAN ports are used for Modbus TCP connections using ethernet cable. Connect
the rectifier controller using ethernet cable to the one of the three LAN ports and configure
the IP address and port number as below. In order to login to rectifier controller, use one of
the three LAN ports of the RUT device and not disconnecting the cable from RMS to
controller.

10
Helios Towers | Private & Confidential

Controller configuration
Major Controllers we focus on

11
Helios Towers | Private & Confidential

Controller configuration
Orion Modbus Mapping
Loading Mapping so that the Modbus data can be transmitted. Login to the controller and follow
below instruction.

Configuration > System > File Manager > File Type > Modbus Slave Mapping
Choose File > HT_ModbusSlave_Mapping_02

12
Helios Towers | Private & Confidential

Controller configuration
Changing Modbus Slave Mode and listen port to 502
Once the mapping file installed change modbus slave mode as per below
Configuration > System > Interface Set Up > Remote Monitoring > Modbus Slave and then
change mode to TCP
IF TCP not enabled, we would Not Get the rectifier Data

13
Helios Towers | Private & Confidential

Deepsea configuration
The maximum recommended length of RS232 cable is 15m, if the cable run from the
Teltonika to the Deepsea is 15m or less, then RS232 is preferred. The RS232 cable is a
straight through cable with one male and one female D9 connector

The installation is the same for a DSE7320 MkI and DSE7320 MkII controllers.

14
Helios Towers | Private & Confidential

Deepsea configuration
Login to Deepsea and go to Communication and basic. Select respective port type.

15
Helios Towers | Private & Confidential

Deepsea configuration
RS232 connection
Once the cable is installed properly go to RS232 Port – Basic and select as per below.
Important: Make sue the baud rate selected matches the one on Teltonika device settings
.

16
Helios Towers | Private & Confidential

Deepsea configuration
RS485 connection
The RS485 Connector is a 6 way terminal block and if used with a single single
device it is necessary to link out the connector as below.

17
Helios Towers | Private & Confidential

Deepsea Connection
The Deepsea is connected as below
RUT955 DP / RP to Deepsea PIN56 (Orange Cable)
RUT955 DN / RN to Deepsea PIN57 (Blue Cable)
RUT955 Ground to Deepsea PIN 58 (Brown cable)

18
Helios Towers | Private & Confidential

Deepsea Connection
The Deepsea is connected as below
RUT955 DP / RP to Deepsea PIN56 (Orange Cable)
RUT955 DN / RN to Deepsea PIN57 (Blue Cable)
RUT955 Ground to Deepsea PIN 58 (Brown cable)

19
Helios Towers | Private & Confidential

Log on to RUT955 Web Interface


To log on to the Teltonika RUT955 web interface you first need to configure your laptop to
have a static IP address by following the process

20
Dataminer RMS Configuration

Private & Confidential


Helios Towers | Private & Confidential

Dataminer
Layout
Helios Towers | Private & Confidential

Dataminer Configuration
IP Configuration
When configuring dataminer to controller, make sure IP addresses are filled and saved as per below. This is found
on below category;

Configuration>System>Interface>Setup>TCP/IP

23
Helios Towers | Private & Confidential

Dataminer Configuration
IP Configuration
After adding the IP address save the new settings and reboot the controller for the changes to reflect.

Configuration>System>Interface>Setup>TCP/IP

24
Helios Towers | Private & Confidential

Dataminer Configuration
Checking License key
❑ In order for controller to send data to Dataminer, controller must have license key. Check the status using below path.

Configuration>Option

❑ If the controller has license key, then SNMP Protocol check box will be ticked.

25
Helios Towers | Private & Confidential

Dataminer Configuration
Processing License key
❑ If the controller do not have license key, get the MAC address and request. Go through below path to get MAC address

Configuration>System>Interface>Setup>TCP/IP

❑ RMS SPOC Send email containing MAC address to HTT System Engineering(Jrunyoro@httanzania.co.tz or
Ishauri@httanzania.co.tz ) team to be provided with license key

26
Helios Towers | Private & Confidential

Labelling:
What?
Where?
When?
Why?

27
Helios Towers | Private & Confidential

LABELLING
What is Labelling?

This is an act of putting tags with

customer name on cables that tap

power from customer equipment.

28
Helios Towers | Private & Confidential

LABELLING
Where do we label?

Labelling is done by putting a tag with

customer name where it is easily visible.

29
Helios Towers | Private & Confidential

LABELLING
When do we label?

Labelling is supposed to be done during

PM maintenance or in any visit that FE

will discover that the tag is unavailable

or not readable.

Also, when a new customer is added or

removed at site labelling has to be

updated.

30
Helios Towers | Private & Confidential

LABELLING
Elteck Monitoring Kit

31
Helios Towers | Private & Confidential

Troubleshooting Fig 1
Online
Offline Teltonika
Not activated

Teltonika have three status which


can be detected on the Device Fig 2
while field engineer is at site.
Online – Green light - Fig 1
Offline – Red Light - Fig 2
Not activated – Black Light - Fig 3

Fig 3

32
Helios Towers | Private & Confidential

Console data troubleshooting


What are data in console?

If the device is Online its supposed to send data in Console.

NOC team can detect data are send in console by

checking Last Seen should be less than 24hrs for device to

be confirmed Online. Also, the last Updates of Data in

Rectifier and Generator should be as of latest time.

33
Helios Towers | Private & Confidential

Console data troubleshooting


Device/Site Online but does not send rectifier data in console?

The connection of ethernet cable to Teltonika device and controller, enables

data to be send in console. When this cable is disconnected/Loose connection

then we cannot see rectifier data.. Team must make sure the LAN/Ethernet cable

is always in controller.

34
Helios Towers | Private & Confidential

Console data troubleshooting


Device/Site Online but does not send rectifier data in console?
If You come across with this error
and device is online meaning,
there is no connection to the
rectifier. Confirm by checking if the
Modbus is updated and installed
also save mode as TCP
Configuration > System > Interface Set Up > Remote
Monitoring > Modbus Slave and then change mode
to TCP

35
Helios Towers | Private & Confidential

Console data troubleshooting


Device/Site Online but does not send Generator data in console?
When check the generator data in console and Teltonika and come across with The below message

meaning there is no connection between DSE and Teltonika..

36
Helios Towers | Private & Confidential

Console data troubleshooting


Device/Site Online but does not send Generator data in console?

Go to DSE controller, 7320 MKII Configuration

❑ Communication

❑ Identify the Connection if was done on RS232 OR 458

Port Then Basic setup make sure the baud rate set is the

same as the one from Teltonika

❑ By Doing this we will resolve the Issue on Generator not

sending data in console

37
Helios Towers | Private & Confidential

RMS Temper List Process

38
Helios Towers | Private & Confidential

RMS Temper List Process


First Attempt:

The Temper will be recorded in RTL list, SWO issued and Sending escalation

mail to HTT & MP ops Management

Second Attempt:

Apply SLA -4 and sending escalation Mail to HTT & MP operation

management

Third Attempt:

Responsible FE will be blocked from Accessing the site, Updated in Master RTL

list , Apply SLA -4 and sending escalation mail to HTT & MP ops Management

39