Professional Documents
Culture Documents
OLT-C-Optical-Module Potencias
OLT-C-Optical-Module Potencias
OLT-C-Optical-Module Potencias
FEATURES
APPLICATIONS
STANDARDS
1/8
PLT12-C+
Storage Temperature Tstg -40 +85 ℃ Exceeding the Absolute Maximum Ratings may
Commercial Case Operating Temperature Range 0 +70 cause irreversible damage to the device. The
Tcase ℃ device is not intended to be operated under the
Industrial Case Operating Temperature Range -40 85
condition of simultaneous Absolute Maximum
DC Supply Voltage VCC 0 4.2 V
Ratings, a condition which may cause irreversible
Relative Humidity - Operating RH O 5 95 % damage to the device.
Receiver Damaged Threshold 5 dBm
0 70 Commercial
Operating Case Temperature Tc ℃
-40 85 Industrial
TX 2488.32
Data Rate(TX/RX) Mbit/s
RX 1244.16
2/8
PLT12-C+
SD Hysteresis 0.5 6 dB
Note 1: Measured with a PRBS 223-1 test pattern @1244.16Mbit/s and ER=10dB, BER <=10-12
3/8
PLT12-C+
Receiver Amplitude Recovery Time TRECOVERY 25.6 ns Refer to the reset signal falling edge
TGUARD
Optical Signal
( ONT 2)
Optical Signal
( ONT 1)
TRESET
Reset
T RECOVERY
Electrical Signal
(OLT)
4/8
PLT12-C+
Optical Signal During Time TONT EN_DUR 525 ns For RSSI Measurement
ONT 1 Optical
Input to OLT
TONT EN_DUR
ONT 2 Optical
Input to OLT
TD TW
RSSI_ Trigger
2
I2C Reading I C Access Prohibited I2C Access Acceptable
EEPROM INFORMATION
5/8
PLT12-C+
2 02 01 SC Connector Values
SD,TX_FAULT and
65 41 1C Option Values
TX_DISABLE
SFF-8472 Rev 9.4 A2 (HEX) ADDRESS TABLE FOR ALARM AND WARNING DATA
Alarm Threshold Data Warning Threshold Data Alarm Bit Warning Bit
Measured
8472 Address + Address +
High Value Low Value High Value Low Value Values
Parameter Position Position
MSB LSB MSB LSB MSB LSB MSB LSB MSB LSB HIGH Low HIGH Low
TX Bias 16 17 18 19 20 21 22 23 100 101 112 (3) 112 (2) 116( 3) 116 (2)
TX Power 24 25 26 27 28 29 30 31 102 103 112 (1) 112 (0) 116 (1) 116 (0)
RX Power 32 33 34 35 36 37 38 39 104 105 113 (7) 113 (6) 117 (7) 117 (6)
6/8
PLT12-C+
PIN ASSIGNMENT
2 TX_Fault LVTTL TX Fault TX Fault Alarm, TX Fault State: High; TX Normal State:
Low
19 TD- LVPECL TX Data- Inv. TX data input, internally AC coupled with 100ohm
terminated
7/8
PLT12-C+
8/8