Professional Documents
Culture Documents
Standard Abbreviations: Kec Hub
Standard Abbreviations: Kec Hub
10. THE CONTRACTOR AND HIS SUB-TRADES SHALL PROVIDE THE OWNER FF&A PLAN NOTES:
G R QUANTITY REQUIREMENTS FOR WALL COVERINGS, CARPETS, CARPET
R RESILIENT FLOORING 01 ISSUED FOR CONSTRUCTION 30/04/2023
G GLASS UNDERPADS, ETC., IN AMPLE TIME PRIOR TO OWNER'S NECESSITY TO PLACE 1. NUMBERS OF FURNISHINGS ARE FOR REFERENCE ONLY AND REFER TO
RAD RADIUS 00 ISSUED FOR CONSTRUCTION 09/03/2023
GA GAGE, GAUGE ORDERS. QUANTITY REQUIREMENTS SHALL INCLUDE AVERAGES FF&A SPECIFICATIONS. (AVAILABLE FROM OWNER UPON REQUEST) Revision
RCP REFLECTED CEILING Rev. No. Description
PLAN
STIPULATED BY THE OWNER. Date
2. CUSTOM BUILT BOOTHS/BANQUETTES TO BE SUPPLIED BY OWNER.
11. ALL DIMENSIONS ARE CLEAR DIMENSIONS UNLESS NOTED OTHERWISE. SEE OWNER NAME
ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS OF SUBSTRATE. 3. WHERE (CUSTOM) BOOTHS/BANQUETTES MEET LOW PARTITIONS, ETC.,
GRAPHIC SYMBOLS INTERIOR GRAPHIC SYMBOLS/ MATERIALS NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DRAWINGS. FABRICATED BY CONTRACTOR, COORDINATION WILL BE REQUIRED
Knowledge Economic City
BETWEEN CONTRACTOR AND BOOTH/BANQUETTE MANUFACTURER FOR
ELEVATION NO.
INTERIOR ABBREVIATION LEGEND 12. ALL MODULAR DIMENSION MATERIALS (ACOUSTICAL CEILING PANELS, DIMENSIONS, HEIGHTS, FINISHES, ETC.
Knowledge Economic City
1 STONE, TILES, CERAMIC TILES, RESILIENT TILES, ETC.) SHALL BE LAID OUT
INTERIOR ELEVATION SYMBOL IN HARD FINISH FF&A AND INSTALLED IN A MANNER SO THAT ALL CUTTING OCCURS AT PERIMETER 4. F.F.& A. INSTALLER IS RESPONSIBLE FOR UNLOADING, UNPACKING, AND
4 I-100 2 MU,DD, ADND CD PHASE UNLESS NOTED OTHERWISE. SETTING IN PLACE OF ALL OWNER PROVIDED FURNISHINGS,
ELEV PLAN DESCRIPTION ELEV PLAN DESCRIPTION MASONRY
3 ACCESSORIES, AND EQUIPMENT AS SHOWN ON THESE DRAWINGS. DESIGN CONSULTANT:
SHEET NO. (MU,ID)
- SAN - - AC - 13. NEW GYPSUM WALLBOARD SUBSTRATES APPLIED OVER NEW STEEL STUDS
- SAN - BATH & PLUMBING ACCESORIES OR NEW WOOD STUDS SHALL BE SECURED WITH APPROPRIATE SCREW
CONCRETE FASTENERS. INSTALLATION SHALL BE IN ACCORDANCE WITH THE "GYPSUM Chapman Taylor LLP
10 Eastbourne Terrace
- BD - CONSTRUCTION HANDBOOK" BY U.S.G. ALL JOINTS SHALL BE TAPED AND REFLECTED CEILING PLAN NOTES: London
HEIGHT - PL -
10'-0" HEIGHT SYMBOL - PL - CEILING TILE BEDDING FINISHED AND APPROPRIATE METAL TRIM PROVIDED WHERE REQUIRED. W2 6LG
United Kingdom
A.F.F. HEIGHT REFER TO ARCHITECTURAL DRAWINGS. 1. INTERIOR DESIGN (ID) CEILING PLANS ARE INTENDED TO SHOW CEILING
EARTH FINISHES AND PROFILES ONLY.
REFERENCE - C -
- GL -
AOR CONSULTANT:
- GL - GLAZING - C - CARPET 14. ALL WOOD USED FOR STRUCTURAL FRAMING AND SHEATHING IN
CONCEALED SPACES SUCH AS FLOORS, CEILINGS, ETC., SHALL BE TREATED 2. REFER TO ELECTRICAL, HVAC, AND FIRE PROTECTION DRAWINGS FOR
10'-0" -
HEIGHT SYMBOL LEADER GROUT WITH FIRE-RETARDANT CHEMICALS (F.R.T.) (KOPPERS OR EQUAL) SWITCHING, EXIT SIGNS, EMERGENCY LIGHTING, DUCT, GRILLE, Consulting Engineers & Partners
A.F.F. - H - - CH -
- H - HARDWARE SEATING COMPATIBLE WITH FINISHES SPECIFIED AND TO MEET APPROPRIATE DIFFUSER LOCATIONS, AND COORDINATION OF SPRINKLER HEAD Al-Jemaiah Commercial Center
King Fahd Rd & King Abdullah Rd Junction
BUILDING CODES. LOCATIONS. ANY CONFLICT WITH LIGHTING FIXTURE LOCATIONS SHALL Riyadh
- DL -
METALS BE BROUGHT TO THE ATTENTION OF THE OWNER AND COORDINATE. Kingdom of Saudi Arabia
OFFICE STAMP
WALL TYPE
1i
3.5 0 WALL TYPE TAG
STRUCTURE THICKNESS
FIRE RATING