Professional Documents
Culture Documents
For RTU-300: 100G Test Module
For RTU-300: 100G Test Module
for RTU-300
Remote Test Unit
RTU-600 Module 2
INTERFACES
Test Interfaces
100GE V-SAM test results with 8 services. RTU-600 Optical
is able to perform up to 32 services QSFP28 Module
• 100GE
• OTU4
QSFP+ Module
• 40GE
• OTU3
Physical Layer
RX Optical Power Measurements
• Per-lane input power measurement
• ± 2 dB accuracy, 0.01 dB resolution
• Aggregated (total) power in dBm
• LOS and Saturation indication
TX Optical Power Monitoring
• Per-lane output power in dBm
• Aggregated (total) power in dBm
RX Frequency Measurements
• RX Frequency (1 kHz resolution)
100GE-LR4 PCS analysis for alarms and errors
• Offset (ppm): Current, Minimum, Maximum
TX Clock Source
Internal: Quartz, ± 3.5 ppm
Tx Frequency Offset
• ±150 ppm
• Steps of 0.1 ppm
Recovered: from incoming RX signal
External Clock Input
• Connector: 75 Ohm BNC
• 2.048 MHz, 1.544 MHz, 10 MHz
• 1.544 Mbps, 2.048 Mbps (AMI, HDB3, B8ZS)
• 1 PPS
RTU-600 Module 3
ETHERNET
Ethernet Testing
40GE and 100GE Functions 100G/40G PCS Layer Testing
Reliability, scalability and Quality of Service are the attributes PCS lane mapping: default, manually defined, random or shift
needed for Ethernet to turn into Carrier-grade Ethernet. With PCS Skew generation per lane pair (0 to 16000 bits)
standard features including RFC2544, VSAM, Throughput, MPLS Configurable Skew alarm threshold
and VLAN support, this test set has all the tools necessary to RX Skew tolerance up to 4000 bits
truly ensure end-to-end carrier-grade Ethernet services. RX PCS lane monitoring: skew measurement (bits and ps) and
lane mapping
Key Features PCS Error/Alarm injection per lane or all lanes
• Transmit frequency offset to stress the network up to ±150 ppm PCS Error injection (single, burst or rate): Invalid Sync Header,
• Optical Lane BERT Invalid Alignment Marker, BIP error
• CAUI-4/XLAUI Lane BERT PCS Alarm injection (continuous): Loss of Alignment Marker
• FEC Layer Testing with Skew generation/monitoring Lock, Loss of Block Lock, High BER
• PCS Layer Testing with Skew generation/monitoring PCS Lane Error counters (aggregate and per lane): Invalid Sync
• Service Disruption Measurements Header, Invalid Alignment Marker, BIP error
• Throughput, latency, jitter, frame loss, and back-to-back PCS Lane Alarm: Loss of Alignment, Loss of block label, High-BER
measurements per industry-standard RFC2544
• Multi-stream testing with up to 32 fully independent and Lane BERT
configurable streams Per CAUI-4/XLAUI lane or optical lane unframed BERT
• IPv4 and IPv6 traffic generation PRBS pattern: 231-1, 223-1, 215-1, 27-1
• MAC Flooding Error injection (single or burst) per lane or multiple lanes: Bit error
• Q-in-Q (VLAN stacking) and multiple MPLS tag support Alarm injection per optical lane or multiple optical lanes: Optical LOS
• BER testing at Layer 2 and Layer 3 with or without VLAN Per lane and aggregate Bit error count and rate and Pattern loss
and MPLS tags
• Smart Loop mode for Layer 2 and Layer 3 with all key Optical Power Measurement
measurements on received traffic provided on the Per wavelength TX and RX power measurements
loopback port QSFP28 vendor’s detailed register display: Vendor, part number,
• Line rate packet capture with Wireshark™ decode Serial number, standard compliance
Optical module status: Temperature, Voltage, Alarm status
Interfaces
100GE/40GE compliant with IEEE 802.3ba Framed Ethernet Traffic Generation
MSA compliant transceiver interfaces Layer 2 or Layer 3 traffic
QSFP28 Interface bit rates Test Frame Header
• 100GBase-R 103.125 Gbps • IEEE 802.3 and Ethernet II (DIX) frames
QSFP+ • Configurable Source and Destination MAC and Ethernet Type
• 40GBase-R 41.25 Gbps • VLAN stacking up to 3 VLAN tags w/configurable priority & type
Frequency offset: +/- 150ppm (0.1 ppm step) • MPLS-TP label with configurable LSP, PW and CW fields
External reference clock input: 2.048 Mbps, 2.048 MHz, 1.544 • Provider Backbone Bridge (PBB) support with
Mbps, 1.544 MHz, 10 MHz, Received signal configurable Backbone MAC Source and Destination,
I-SID, PBB-VLAN ID and priority
Operating Modes • EoE (Ethernet over Ethernet) support with configurable
Terminate EoE MAC Source and Destination, Ethernet Type, EoE
Loopback VLAN ID and Priority, TTL and EID
• Fully configurable IPv4 or IPv6 header
• MPLS up to 3 labels with configurable Label/S/CoS and TTL
Frame generation in fixed, random, increment, decrement modes
• Frame sizes from 64 to 1518 bytes and jumbo frames up
to 16000 bytes
MAC flooding feature generates test frames with up to 4096
incremental Source and/or Destination MAC addresses
Traffic Pattern: Constant, Ramp, Multi Bursts, Single Burst
Ethernet Error Injection: Bit, CRC, Pause, IP Checksum, runt (60 bytes)
PCS Error Injection (per lane or multiple lanes): Invalid Sync
Header, Invalid Alignment Marker, BIP error
Ethernet Alarm Injection: Local Fault, Remote Fault, Optical LOS
PCS Alarm Injection: Loss of Alignment Marker Lock, Loss of
Block Lock, High BER
RTU-600 Module 4
ETHERNET
Key Measurements Alarm Detection
Error Measurements: Bit/BER (BERT and single stream • 10GE: LOS, LOSync, Service disruption (current, total, last,
Throughput Test), CRC, PCS Errored Blocks, IP checksum, min/max, # of occurrences), Local Fault, Remote Fault,
jabber frames, runt frames, Frame loss (count and %), OSS PCS-HI-BER, PCS-LOBL, WAN SONET Alarms: LOF, AIS-L
Alarm Detection: LOS, Service Disruption, Local and Remote Fault and RDI-L WAN SDH Alarms: LOF, MS-AIS, MS-RDI
FEC Alarms and Errors: HiSER, LOA, LOAMPS, FEC Lane Swap, • 1GE: LOS, LOSync, Service disruption (current, total, last,
Uncorrected FEC, Corrected FEC errors, LOAMPS Event, LOA min/max, # of occurrences)
Event, Invalid Transcoded Block, and RX AM Sequence Frame/Packet Statistics
PCS Alarms and Errors: Loss of Alignment, Loss of block label, • Multicast, broadcast, unicast, pause frames, frame size
High-BER, Invalid Sync Header, Invalid Alignment Marker, BIP error distribution
Frame/Packet Statistics: Multicast, broadcast, unicast, pause Rates (min, max, average and current): frame rate, bandwidth
frames, frame size distribution utilization, frame rate, line rate, data rate
Rates (min, max, average and current): frame rate, bandwidth • Frame arrival time (min, max, average and current),
utilization, frame rate, line rate, data rate Frame Delay Variation
Delay (min, max, average and current): round trip delay, inter Service Disruption Time (SDT)
frame gap, jitter, one-way delay between remote devices • Per stream inter-packet gap based measurement
with GPS synchronization • Configurable SDT measurement trigger and SDT violation
threshold
Service Disruption Time (SDT)
Concurrent service disruption measurements are integrated to RFC2544 Compliance Testing
regular Ethernet tests, supporting simultaneous monitoring of Automated tests compliant with RFC2544 with configurable
multiple triggers at all layers. threshold values and maximum transmit bandwidth settings
Throughput, Latency, Jitter, Frame Loss, and Back-to-Back (burst) tests
Layer 2 BERT triggers Frame sizes: 64, 128, 256, 512, 1024, 1280, and 1518 bytes
• LOS, LOBL, LOAML, LOA, Local and Remote faults including 2 user configurable frames
• FCS error, Pattern loss
Layer 3 BERT triggers Loopback Mode
• LOS, LOBL, LOAML, LOA, Local and Remote faults Layer 2: all incoming traffic is looped back with MAC source and
• FCS error, IP check sum error, Pattern loss destination addresses swapped
Layer 2 Throughput triggers Layer 3: all incoming traffic is looped back with MAC and IP
• LOS, LOBL, LOAML, LOA, Local and Remote faults source and destination addresses swapped
• FCS error, Lost (Missing) frame, Out of sequence, Duplicate frames Loopback traffic filters with all MAC/VLAN/IP parameters
Layer 3 Throughput triggers configurable
• LOS, LOBL, LOAML, LOA, Local and Remote faults All key measurements on received traffic provided on the
• FCS error, IP check sum error, Lost (Missing) frame, Out of loopback port
sequence, Duplicate frames
Measurements IP Test Suite
• Disruption time: Current, Last, Minimum, Maximum, Total IP Configuration and validation (IPv4, IPv6, Static, DHCP, PPPoE)
• Number of occurrences MAC address (configurable or default)
• Resolution: 1 μs Ping and trace-route tests (IP address or URL)
Network discovery/ARP wizard
Multiple Streams Throughput Testing
Up to 32 independent traffic streams generation and analysis, IPv6
with configurable filters on 40GE and 100GE interfaces IPv6 compliant test traffic generation and analysis for all test
Up to 10 independent traffic streams generation and analysis, applications (Y.1564 V-SAM, RFC2544, BERT and Multi-stream
with configurable filters on 10GE interface Throughput)
Up to 8 independent traffic streams generation and analysis, IPv6 Loopback capability
with configurable filters on 1GE interface IPv6 Static or Stateless Auto Configuration and Ping function
Each stream can be set with independent frame size, bandwidth,
traffic profile, and QoS levels
MAC flooding feature: generates test frames with up to 4096
incrementing Source and/or Destination MAC addresses
Test Patterns: PRBS: 231-1, 223-1, 215-1, 211-1, normal and inverted
patterns, All 0s, All 1s and User Defined
Error Measurements: Bit/BER (Single Stream only), FCS/CRC,
Jabber/Runt frames, IP Checksum, TCP/UDP Checksum, Frame
Loss (count and %), Out of Sequence
RTU-600 Module 5
OTN
OTN Testing
The RTU-600 Module offers full range of OTN testing capabilities Single & Multi-step Mapping/Multiplex Options
for OTU3 and OTU4 interfaces, including service-activation These 40/100G options offer the most complete and flexible
(Bringing-into-Service), performance verification, maintenance, combinations of payload mappings and multiplexing structures
and troubleshooting. It offers Multi-Layer testing from Physical available for lab, manufacturing, advanced service-activation
layer (WDM), or QSFP28, CAUI-4/XLAUI, OTL, OTU/ODUk, to testing, maintenance, and troubleshooting environments,
bulk payloads, and Ethernet traffic generation up to 100% rate. without increasing complexity or requiring additional training.
OTN Functions
Test Interfaces
MSA compliant transceiver interfaces
QSFP28 Interface bit rates
• OTU4 111.810 Gbps
QSFP+
• OTU3 43.108 Gbps
Key Featuress
• Advanced Mapping/Multiplex Structures
• EoOTN testing with internally generated Ethernet payload OTU4 Single-step mapping/multiplex structures
mapped into OTU3 (up to 40 Gbps) or OTU4 (up to 100 Gbps) • OTU4-ODU4-ODU3
• OTU, ODU, OPU overhead manipulation and monitoring • OTU4-ODU4-ODU2e
• OTU, ODU, OPU layer alarms/errors generation and analysis • OTU4-ODU4-ODU2
• OTU, ODU, TCMi trace messages • OTU4-ODU4-ODU1
• Forward error correction (FEC) testing • OTU4-ODU4-ODU0
• Tandem Connection Monitoring OTU4 multi-step mapping/multiplex structures
• Frequency offset generation • OTU4-ODU4-ODU3-ODU2e
• OTU4-ODU4-ODU3-ODU2
Operating Modes • OTU4-ODU4-ODU3-ODU2-ODU1
Normal (terminal) • OTU4-ODU4-ODU3-ODU2-ODU1-ODU0
• The instrument terminates the line, serving as source and • OTU4-ODU4-ODU3-ODU2-ODU0
sink for the generated traffic • OTU4-ODU4-ODU3-ODU1
• Offers full access to Overhead and Payload alarms and • OTU4-ODU4-ODU3-ODU1-ODU0
error generation and monitoring • OTU4-ODU4-ODU3-ODU0
Payload Through • OTU4-ODU4-ODU2-ODU1
• Instrument retransmits the received Payload and allows • OTU4-ODU4-ODU2-ODU1-ODU0
access to Overhead manipulation • OTU4-ODU4-ODU2-ODU0
• Offers full access to Overhead alarms and error • OTU4-ODU4-ODU1-ODU0
generation as well as Payload monitoring • Flexible TS selection for each ODUk stage
Line Through OTU3 Single-step mapping/multiplex structures
• Instrument regenerates and retransmits the entire • OTU3-ODU3-ODU2e
received signal • OTU3-ODU3-ODU2
• Offers minimal interaction with the test signal • OTU3-ODU3-ODU1
• Provides full access to Overhead and Payload alarms and • OTU3-ODU3-ODU0
error monitoring OTU3 multi-step Mapping/Multiplex
• OTU3-ODU3-ODU2-ODU1
OTN Mappings • OTU3-ODU3-ODU2-ODU1-ODU0
Standards: ITU-T G.709, ITU-T G.798, ITU-T G.872 • OTU3-ODU3-ODU2-ODU0
Mapping Procedures: AMP, BMP and GMP • Flexible TS selection for each ODUk stage
ODU0 Tributary Slots
Direct OTN Mapping Options • ODTU4.1: N = 1 of 80 TS
Single-stage (direct) mapping options • ODTU3.1: N = 1 of 32 TS
• OTU4-ODU4-Bulk • ODTU2.1: N = 1 of 2 TS
• OTU4-ODU4-100GE • ODTU0.1: N = 1 of 2 TS
• OTU3-ODU3-Bulk • Flexible TS selection
• OTU3-ODU3-40GE Payload Types
• FE: Bulk (Test Pattern)
• 20: ODU Mux structure
• 21: 1.25G Slot Multiplexing
• 07: Transparent Ethernet
RTU-600 Module 6
OTN
Single-Step ODUflex Mapping/Multiplex Options OTL Layer
Adds ODUflex capabilities to the single-step OTN Mapping/ OTL4.10 (OTU4)
Multiplex options OTL3.4 (OTU3)
OTU4 ODUflex Mapping/Multiplex Structures (Nx1.25 Gbps) TX Lane Mapping and Skew Generation
• OTU4-ODU4-ODUflex • Lane ID, Lane #, and Channel assignments
OTU3 ODUflex Mapping/Multiplex Structures (Nx1.25 Gbps) Lane Mappings
• OTU3-ODU3-ODUflex
• Default (1 to 1)
ODUflex Tributary Slots
• Random assignment
• ODTU4.ts: N=1 to 80 TS
• Lane ID Shift
• ODTU3.ts: N=1 to 32 TS
Skew Settings
• Flexible TS selection
• Skew Range: 0 to 64000 bits
Payload Types
• Adjustable Increment/Decrement steps (0 to 200 bits)
• FE: Bulk (Test Pattern)
• Increase and Decrease control buttons and direct keypad entry
• 21: 1.25G Slot Multiplexing
• Alarm Threshold (1 to 4000 bits)
• Enable/Disable RX MFAS Deskew
Multi-step ODUflex Mapping/Multiplex Options
Per-Lane Alarm and Error Monitoring
OTU4 ODUflex Mapping/Multiplex (Nx1.25 Gbps)
• Alarms: OTL-LOL, OTL-OOL, OTL-LOF, OTL-OOF, OTL-LOR,
• OTU4-ODU4-ODU3-ODUflex
OTL-OOR, OTL-OOLLM, OTL-OOMFAS, High Skew
• OTU4-ODU4-ODU3-ODU2-ODUflex
• Errors: OTL-LLM, OTL-MFAS, OTL-FAS
• OTU4-ODU4-ODU2-ODUflex
• Soft LED overview and individual event counters
OTU3 ODUflex Mapping/Multiplex (Nx1.25 Gbps)
• Per-lane Skew measurements in bits and picoseconds
• OTU3-ODU3-ODU2-ODUflex
• Independent OTL events log with time stamp
ODUflex Tributary Slots
• ODTU4.ts: N = 1 to 80 TS
OTU Layer
• ODTU3.ts: N = 1 to 32 TS
Alarm and Error Monitoring
• ODTU2.ts: N = 1 to 8 TS
• Alarms: LOM, OOM, SM-IAE, SM-BDI, SM-BIAE, SM-TIM
• Flexible TS selection for each ODU stage
• Errors: MFAS, SM-BIP, SM-BEI, Correctable FEC,
Payload Types
Uncorrectable FEC
• FE: Bulk (Test Pattern)
• 21: 1.25G Slot Multiplexing
ODU Layer
ODTUG Multiplexing Alarm and Error Monitoring
• Alarms: AIS, OCI, LCK, PM-BDI, PM-TIM
Payload Types supported
• Errors: PM-BIP, PM-BEI
• FE – ODU4-PRBS, ODU3-PRBS
• 07 – OTU4-100GE, OTU3-40GE
OPU Layer
• 20 – ODU Multiplex Structure
• 21 – 1.25G Slot Multiplexing Payload Type (PT): Generates and displays received PT value
Expected Payload label setting
Test Setup Enable/Disable PLM monitoring
Test configuration, menus, and results are presented in VeEX’s Alarm and Error Monitoring
intuitive GUI, requiring little or no training for new or existing • Alarms: PLM, LO-OMFI, OO-OMFI
VePAL™ users, maintaining a consistent user experience from • Errors: OMFI (ODTU4.M)
the lab to the field.
GMP Stuffing
Layer-based graphical configuration interface allow users to build TX Settings
the test signal in a logical layer by layer sequence • Extended Offset support (Enable/Disable)
• CAUI-4/XLAUI • Effective Cm Value
• OTL Lanes TX Values
• OTN Signal • Nominal Cm Value, Nominal Bit Rate (kbps), Effective Bit
• ODUk (Mapping and Multiplexing) Rate (kbps), Offset (ppm)
• Payload (Bulk or Ethernet) Alarm and Error Monitoring
• Test Pattern (CBR) or Traffic (Packets) • Alarms: GMP Loss of Sync, GMP Cm=0; in seconds
• Errors: CRC-5, CRC-8; count and ratio
RX Statistics
• Effective Cm Value, Minimum Cm Value, Maximum Cm Value
• Nominal Bit Rate (kbps), Effective Bit Rate (kbps), Offset (ppm)
• No Change, Single Increments, Double Increments, Single
Decrements, Double Decrements, New Values
RTU-600 Module 7
OTN
AMP Stuffing Alarm Generation
TX Settings Physical Layer
• Offset (ppm) • LOS
• Stuffing Method: +1/0/-1 (PJO2 not used), +2/0/-1 (PJO2 used) • Affected Optical Lanes: Single or Multiple
RX Statistics • Modes: Continuous (manual)
• Offset (ppm) OTL Layer
• Positive, Double Positive, Negative, Total • LOF, OOF, OOLLM, OOMFAS
• Affected Lanes: Single or Multiple
BER Test (Alarm and Error Monitoring) • Modes: Continuous (manual), Single Burst (# of ON
• Alarms: LOP (Loss of Pattern) frames), Continuous Burst (# of ON frames and # of OFF frames)
• Errors: Bit (Test Sequence Error) OTU/ODU/OPU
• OTU-LOM, OTU-OOM, SM-IAE, SM-BDI, SM-BIAE, SM-
Test Patterns TIM, ODU-AIS, ODU-OCI, ODU-LCK, ODU-LOF, ODU-OOF,
The following test sequences can be generated in Bulk mode PM-BDI, PM-TIM, TCMi-AIS, TCMi-OCI, TCMi-LCK, TCMi-
• PRBS: 231-1 , 223-1, 215-1, 29-1 BDI, TCMi-TIM, TCMi-BIAE, TCMi-LTC, OPU-PLM, GMP
• Normal or Inverted LO-Sync, GMP Cm=0
• ODTU4.M: LO-OMFI, OO-OMFI
Service Disruption Measurementss • Modes: Continuous (manual), Single Burst (# of ON
Service disruption measurements are integrated to the regular frames), Continuous Burst (# of ON frames and # of OFF frames)
OTN BER test, supporting simultaneous monitoring of multiple
Physical, OTL, OTU, ODU alarm and error sensors. Each layer OTN Overhead Analysis and Generation
is monitored independently, including all the ODU layers in Multi-stage support: Provides access to OTU and ODUk
multi-stage mapping/multiplexing configurations. overheads for all the layers present in complex mapping/
Alarm Sensors multiplex structures
• Physical layer: LOS • OTU4, ODU4, ODUk
• OTL layer: LOF, OOF, LOL, OOL • OTU3, ODU3, ODUk
• OTN layers: OTU-LOM, OTU-OOM, SM-IAE, SM-BDI, SM- Analysis – Decode and Display
BIAE, ODU-LOF, ODU-OOF, ODU-LOM, ODU-OOM, ODU- Multiframe selection modes
LCK, ODU-OCI, ODU-AIS, PM-BDI • Display bytes can be locked to specific multi-fame (0 to 255)
Error Sensors • Free running
• OTL layer: FAS, MFAS Byte Decoding
• OTN layers: OTU-MFAS, SM-BIP, SM-BEI, ODU-FAS, ODU- • On-screen Decode of all bytes and strings
MFAS,PM-BIP, PM-BEI, Bit Error/Pattern Loss • Byte Capture (raw data): 256 bytes (Hex)
Event Separation: 0 to 10000 ms ODUk bytes in hexadecimal, binary or ASCII formats
Pass/Fail Limit: 1 to 1000 ms • SM-TTI (SAPI, DAPI, User), SM-BIP, SM-BEI (BEI/BIAE, BDI, IAE)
Results Summary • PM-TTI (SAPI, DAPI, User), PM-BIP, PM-BEI (BEI/BIAE, BDI, IAE)
• Total number of Service Disruptions • TC, TCMi-TTI (SAPI, DAPI, User), TCMi-BIP, TCMi-BEI (BEI/
• Current Service Disruption (μs) BIAE, BDI, IAE)
• Last Service Disruption (μs) • GCC0, CCC1, GCC2 bytes
• Longest Service Disruption (μs) • PCC/APS bytes
• Shortest Service Disruption (μs) • Reserved bytes
• Time stamped with 1 μs resolution OPUk bytes in hexadecimal and binary formats
Disruption Events Tables • JC1, JC2, JC3, JC4, JC5, JC6, PSI, NJO/OMFI
• Track every Service Disruption event for each layer Generation - Programmable Bytes and sequences
• Time stamp with 1 μs resolution OTU and ODU Trace Generation
• Duration with 1 μs resolution • SAPI (15 characters)
• Pass/Fail Verdict • DAPI (15 characters)
• Tracks individual sensor events that occurred during the • User (31 characters)
disruption period with time stamp and duration (1 μs resolution) TCMi Trace Generation
• SAPI (15 characters)
Error Insertion • DAPI (15 characters)
OTL Layer • User (31 characters)
• FAS, MFAS, LLM Set TCMi Status
• Affected Lanes: Single or Multiple • No source TC, In use without IAE, In use with IAE,
• Modes: Single, Single Burst, Rate Reserved, ODUk-LCK, ODUk-OCI, ODUk-AIS
OTU/ODU/OPU • Enable/Disable TC monitoring
• MFAS, SM-BIP, SM-BEI, Correctable FEC, Uncorrectable OTU/ODU Trace Analysis and Generation
FEC, ODU-FAS, ODU-MFAS, PM-BIP, PM-BEI, TCMi-BIP, • Programmable Transmit and Expected OTU and ODUk Traces
TCMi-BEI, GMP CRC-5, GMP CRC-8, OMFI (ODTU.M) • OTU and ODU SAPI, DAPI, and User
• Modes: Single, Single Burst, Rate • Enable/Disable OTU/ODU TIM monitoring
Payload
• Bit (Test Sequence Error)
• Modes: Single, Single Burst, Rate
RTU-600 Module 8
OTN/SDH/SONET
Common Functions &
Measurements
Tandem Connection Monitoring (TCM) Service Disruption
TCMi Monitoring (1 through 6) Service disruption time (SDT) measurements are integrated
• Alarms: AIS, OCI, LCK, BDI, BIAE, LTC, TIM to the regular BER tests, supporting multi-layer sensor
• Errors: BIP, BEI monitoring for OTN and SDH/SONET
Trace Identifier Monitoring and Generation OTN Sensors
• Programmable Transmit and Expected SAPI, DAPI and User traces • LOS, OTU-AIS
• Copy trace from RX • OTU-LOF, OTU-LOM, OTU-IAE, OTU-BDI, SM-BIAE, ODU-
• Enable/Disable TIM monitoring AIS, ODU-LCK, ODU-OCI
• FAS, MFAS, OTU-BIP, OTU-BEI, ODU-BIP, ODU-BEI
Ethernet over OTN Testing* Pass/Fail range: 15 to 200 ms
Internally generated Ethernet Payloads Gate Time: 20 to 4000 ms
• Layer 2 SDT Results Summary
• Layer 3 (IPv4 and IPv6) • Last Service Disruption Time
• VLAN: Up to 3 tags • Longest Service Disruption Time
• MPLS: Up to 3 tags • Shortest Service Disruption Time
Ethernet Testing • Time stamps
• BERT • Resolution: 10 μs
• Throughput • Total number of Service Disruptions events observed
Traffic Flows Disruption Events Table
• Programmable test bandwidth up to 100% • Tracks every Service Disruption event for all layers
• Constant Bandwidth • Time stamp with 10 μs resolution
• Ramp (Start BW, Stop BW, BW steps, Ramp time, Repetitions) • Duration with 10 μs resolution
• Burst (Two traffic levels - Burst 1 BW, Burst 2 BW, Burst 1 • Individual Pass/Fail Verdicts
time, Bust 2 time) • Tracks individual sensor events that occurred during the
• Single Burst (1 to 10000 frames) disruption period with time stamp and duration (10 μs
• Unless otherwise specified, traffic (BW) values can be resolution)
entered in % of line rate, # of IPG Bytes, Frames per
Second, and Mbit/s Signal Level and Frequency Measurement
Test Patterns (payload) Available for Optical Interfaces
• PRBS: 231-1 Signal level
• Normal or Inverted • Optical power in dBm and Loss/Saturation graph
Test Traffic RX Filter Frequency (Line and Payloads)
• MAC Source, MAC Destination, Frame Type, DSCP, • Resolution: 1 bit/s (bps)
Protocol Type, IP Source, IP Destination Frequency Offset
• Resolution: 0.1 ppm Current, Minimum and Maximum
*Refer to the Ethernet Testing section for more details on Ethernet
test results. Round Trip Delay
(Available for all interfaces & mappings)
Events Log Measurement Range: 1 μs to 10 seconds Resolution: ±0.1 μs
Date and time stamped record of all events occurred during a
test, presented in tabular format Event Logging
Includes event name, time, duration and count/severity Date and time stamped records of all error and alarm events
Individual event logs for OTL, OTN, BERT and Ethernet occurred during a test, presented in tabular format
RTU-600 Module 9
GENERAL
Additional Functions
Test Results Management
Local and remote web-based interface provides easy access
and manipulation to OTN and Ethernet Test Results
Save, View, Rename, Lock and Delete functions