Orbital Tech Catalogue
Orbital Tech Catalogue
com
PRODUCT
External Lightning Protection
CATALOGUE
ORBTECH® Earthing & Bonding Equipment
LIGHTNING&SURGE
PROTECTION TECHNOLOGIES
INTRODUCTION TO ORBITAL TECHNOLOGY
ABOUT ORBITAL
ORBITAL Lightning Protection Technologies is a fully compatible and competitive manufacturer and
supplier of external direct strike lightning instruments,grounding/bonding equipments under ORBTech®
brand, surge protection devices(SPDs) and all kinds of Lightning protection side products. For long
successfull years, ORBITAL has been providing expertise for lightning protection insights to its customers
in some of the most lightning prone areas of the world. Each of our personnel have extensive experience
in risk management, system designings, training, installation, certification, qualifications, production and
commissioning of all systems in a wide variety of industry groups like manufacturing, transportation,
security and military zones.
ORBITAL also maintains a third party Quality Management System to AS/NZS ISO 9001:2015, ISO
14001:2015, ISO 29001:2010, OHSAS 9001:2007 and CE European Conformity certificates. ORBITAL ’s most
range of products and services are exported from its head Office, manufacture and research facility in
Izmir, Turkey and via regional/local offices and branches worldwide in 4 continents.
Russia
Serbia Turkey
Azerbaijan
Morocco Israel Taiwan
Iran India
Philippines
Brazil
Our company has been recognised in Turkey in a very respectful aspect by Ministry of Industry, Exporters
Agencies and Trade Chambers. ORBITAL’s fascinating production and export successes has been awarded
by government and export agencies with many prestigious awards.
5 | www.orbitaltechs.com
INTRODUCTION TO ORBITAL TECHNOLOGY
This infographic are prepared by ORBITAL LIGHTNING PROTECTION Co. It cannot be used out of permission. All rights reserved. 2019
Please contact via info@orbitaltechs.com through OR +905433974497 by phone. www.orbitaltechs.com
8 | www.orbitaltechs.com
HOW TO INSTALL?
Down-Conducting
Down-conductors should
have a cross-section of at least
50 mm2.bSince lightning
current needs to be driven, flat
conductors (tape)
are preferable to round
conductors as they have a
larger exterior surface area
for the same amount of
material. Tin-plated copper
is recommended due to its
physical, mechanical and
electrical characteristics
(conductivity, malleability,
corrosion resistance and so on).
Down-conductors should be
protected by installing guard
tubes up to a height of 2 m
above ground level.
Earthing
Each down-conductor must
have an earth termination
system. Earth termination
systems should be located
outside the building, except
where this is absolutely
impossible. The resistance of
the earth termination system
measured by conventional
means must be lower than 10
Ω, when separated from other
conductive elements.
13 | www.orbitaltechs.com
EXTERNAL LIGHTNING PROTECTION
GENERAL DESCRIPTIONS
ZERU Early Streamer Emission (ESE) lightning terminal can anticipate all other elements and items
within its protectable range according to its protection level radius by intercepting the lightning
strikes and conducting these strikes into the earth through the safest and projected ways. ZERU
ESE Terminal work as to principle of creating IONs by its internal ION GENERATION channels. This
structure itself allows the terminal to conduct the high voltage lightning strikes, even up to 200kA, to
the earthing system then to the earth at the safest way.
ZERU ESE Lightning Terminal is specially suitable to install for solar and wind panels,
telecommunication towers, hospitals, schools and transportation stations.
Tested and certified according to NFC 17- > High Salt mist treatment
102/2011 Early Streamer Emission > Humid sulphurous atmosphere treatment
Standard including DeltaT (ΔT) advance
time test, current withstanding test to > Current withstanding test: 200kA (10/350μs).
determine ZERU’s protection levels. > Advance time DeltaT (ΔT) test
TECHNICAL CHARACTERISTICS
Material Stainless Steel
Weight 3.60 kg
IP Code IP67
2 31 35 39 43
4 63 69 78 85
5 79 86 97 107
10 79 88 99 109
30% more efficient than passive systems Fully compatible with the standards
20 | www.orbitaltechs.com
EXTERNAL LIGHTNING PROTECTION
GENERAL DESCRIPTIONS
HELIA Early Streamer Emission (ESE) lightning terminal can anticipate all other elements and items
within its protectable range according to its protection level radius by intercepting the lightning
strikes and conducting these strikes into the earth through the safest and projected ways. HELIA
ESE Terminal work as to principle of creating IONs by its internal ION GENERATION channels. This
structure itself allows the terminal to conduct the high voltage lightning strikes, even up to 200kA, to
the earthing system then to the earth at the safest way.
HELIA ESE Lightning Terminal is exclusively suitable to install for high-rise buildings,
airports, naval bases, open areas, critical military zones, stadiums and highways.
Tested and certified according to NFC 17- > High Salt mist treatment
102/2011 Early Streamer Emission > Humid sulphurous atmosphere treatment
Standard including DeltaT (ΔT) advance
time test, current withstanding test to > Current withstanding test: 200kA (10/350μs).
determine HELIA’s protection levels. > Advance time DeltaT (ΔT) test
TECHNICAL CHARACTERISTICS
Material Stainless Steel
Weight 4.40 kg
IP Code IP67
2 35 38 44 47
4 19 77 85 89
5 81 90 99 110
10 83 91 101 112
30% more efficient than passive systems Fully compatible with the standards
21 | www.orbitaltechs.com
EXTERNAL LIGHTNING PROTECTION
GENERAL DESCRIPTIONS
CONTRA30 Controlled Early Streamer Emission (CESE) lightning terminal can anticipate all
other elements and items within its protectable range according to its protection level radius by
intercepting the lightning strikes and conducting these strikes into the earth through the safest and
projected ways. CONTRA30 CESE Terminal work as to principle of creating IONs by its internal ION
GENERATION channels. This structure itself allows the terminal to conduct the high voltage lightning
strikes, even up to 200kA, to the earthing system then to the earth at the safest way.
Tested and certified according to NFC > High Salt mist treatment
17-102/2011 EControlled Early Streamer
> Humid sulphurous atmosphere treatment
Emission Standard including DeltaT (ΔT)
advance time test, current withstanding > Current withstanding test: 200kA (10/350μs).
test to determine CONTRA30’s protection
levels. > Advance time DeltaT (ΔT) test
TECHNICAL CHARACTERISTICS
Material Stainless Steel
Weight 2.90 kg
IP Code IP67
2 19 22 25 28
4 38 44 31 57
5 48 55 63 71
10 49 75 66 75
30% more efficient than passive systems Fully compatible with the standards
22 | www.orbitaltechs.com
LIGHTNING STRIKE COUNTERS & TESTERS
GENERAL DESCRIPTIONS
VIRTU Electromechanical Lightning Strike Counter is designed for counting and
recording lightning strikes arrested by ORBITAL Lightning Protection Systems.
Durable and long-living components make VIRTU a perfect complementary for
lightning protection systems.
TECHNICAL CHARACTERISTICS
Weight 0.67 kg
CONDUCTING OPTIONS
Flat Tape: 50 x 5 mm
26 | www.orbitaltechs.com
LIGHTNING STRIKE COUNTERS & TESTERS
GENERAL DESCRIPTIONS
TECHNICAL CHARACTERISTICS
Weight 0.9 kg
CONDUCTING OPTIONS
Flat Tape: 50 x 5 mm
28 | www.orbitaltechs.com