Self WT of Post 4.0kg /M X 2.0m 8.0 KG 0.10 KN Self WT of Chain Link Mesh 3.1 KG/M X 3.0 X 2.75 25.6 KG 0.26 KN Other Accessories 10 KG 0.1 KN Total
Self WT of Post 4.0kg /M X 2.0m 8.0 KG 0.10 KN Self WT of Chain Link Mesh 3.1 KG/M X 3.0 X 2.75 25.6 KG 0.26 KN Other Accessories 10 KG 0.1 KN Total
Self WT of Post 4.0kg /M X 2.0m 8.0 KG 0.10 KN Self WT of Chain Link Mesh 3.1 KG/M X 3.0 X 2.75 25.6 KG 0.26 KN Other Accessories 10 KG 0.1 KN Total
factors Kz = 0.57 upto 4.6 m (15') ht & exposure B,case 2 .. Table 6-3
Kzt = 1
I = 0.87 importance factor , category I .. Table 6-1
blockage due to chain link = 19 % ( 50x50 mesh, I.e.40 wires of 1 m length of 4.75 mm coated dia)
say 20% blockage = 40x1x0.00475= 0.19 m2 /m² area)
Mc = 1.2 Py Z
= 1.2 x 275 x 5297 section modulus, Z= 5297 mm³
= 1748132.348 Nmm
= 1.75 kNm > design moment
hence safe