Technical Information

Page 1 of 7 Universal Control Board III Info-No.


Item no. 130 120 360’-10-00
15/09/2021
2021-P1
(207 - 507 V / 50 - 60 Hz)

1 PARAMETERIZATION
Default settings
# 1 „Mode“ 3
# 2 „Pump“ 0 / 1 / 3*
# 3 „Brush“ 6
# 4 „Fade out time“ 0
*Runtime depends on
length of sole brushes:
500 mm = 0
1000 mm = 1
1600 mm = 3
Note down the set parameters of
your control board!!

Universal control board III

For information on connecting the inputs and outputs, please refer to the circuit diagram.
The control board is equipped with a 7-segment display and various LED indicators for the fault analysis
(see chap. 2.1 and 2.2).
Two rotary encoder switches (Hex switches) are used to set the parameters:

Function selection
1 = # 1 „Mode“ Operating mode in entrance direction (see chap.1.1)
2 = # 2 „Pump“ Runtime of chemical pump (see chap.1.2)
3 = # 3 „Brush“ Runtime of brushes (see chap.1.3)
4 = # 4 „Fade out time“ Reflection light scanner blanking time (see chap. 1.4)
F = Test operation Test of service and empty messages (see chap.1.5)

Setting of the respective parameter (see chap. 1.1 to 1.5)

1. Use the left-hand hex switch to select the function.


The 7-segment display shows the selected function (1, 2 ,3, 4 or F, see table above).
2. Use the right-hand hex switch to set the parameter.
The 7-segment display shows the set parameter an (0 - F, see chap. 1.1 to 1.5).
3. Save the parameter by moving the left-hand hex switch to another (any) position (e.g. turn one
notch further).
4. Finally, set both hex switches to “0” (otherwise no function is possible).

Edited by: FA EN_Universalplatine_3


Technical Information

Page 2 of 7 Universal Control Board III Info-No.


Item no. 130 120 360’-10-00
15/09/2021
2021-P1
(207 - 507 V / 50 - 60 Hz)

1.1 Function # 1 “Mode” (operating mode in entrance direction)

Setting Function
1 The machine starts, when a light scanner is occupied.
The pump runtime is set with “Pump”.
The brushes and the water valve run as long as the light scanner is occupied.

2 The machine starts, when both light scanners are occupied.


The pump runtime is set with “Pump”.
The brushes and the water valve run as long as the light scanners are occupied.
3 The machine starts at an impulse given by the light scanner.
The pump runtime is set with “Pump”.
The brush runtime and the water valve are set with “Brush”.

4 The machine starts at an impulse given by the light scanner.


The pump runtime is set with “Pump”.
The pump runs only at every third signal.
The brush runtime and the water valve are set with “Brush”.

5 The machine starts, when a light scanner is occupied.


The pump runtime is set with “Pump”.
The runtime of the water valve is set with “Brush”.
The brushes run as long as the light scanner is occupied.

6 The machine starts at an impulse given by the light scanner.


The pump runtime is set with “Pump”.
The pump runs only at a signal given by light scanner LT1 (no chemical with signal from
light scanner LT2).
The brush runtime and the water valve are set with “Brush”.

7 The machine starts at an impulse given by the light scanner.


The pump runtime is set with “Pump”.
The pump runs only at every third signal given by light scanner LT1 (no chemical with
signal from LT2).The brush runtime and the water valve are set with “Brush”

8 An impulse given by light scanner 1 starts the machine.


The pump runtime is set with “Pump”.
The brush runtime and the water valve are set with “Brush”.
At an impulse given by light scanner 2, only the brushes start.

9 An impulse given by light scanner LT1 starts the machine.


The pump runtime is set with “Pump”.
The brush runtime and the water valve are set with “Brush”.
The machine does not start at an impulse given by light scanner LT2.

0 Not used
A Special software

Edited by: FA EN_Universalplatine_3


Technical Information

Page 3 of 7 Universal Control Board III Info-No.


Item no. 130 120 360’-10-00
15/09/2021
2021-P1
(207 - 507 V / 50 - 60 Hz)

Setting Function
B An impulse given by light scanner 1 starts the machine.
The pump runtime is set with “Pump”.
The brush runtime and the water valve are set with “Brush”.
The light scanner 2 is faded out.
The blanking time is set at # 4 (applies to both directions).
The relay switches when the light scanner is active.

C-F Not used

1.2 Function # 2 “Pump” (pump runtime)

Setting Function
1 = 2s
2 = 3s
Pump runtime in operating modes 1 and 2 as well as 5 to 9
… = …
Each step = 1 second, max. 10 seconds
9 = 10 s
0 = 1s
1 = 1s
2 = 1.5 s
Pump runtime in operating modes 3 and 4
… = …
Each step = 0.5 seconds, max. 5 seconds
9 = 5s
0 = 0.5 s
A-F Not used

1.3 Function # 3 “Brush” (brush runtime)

Setting Function
1 = 1s
2 = 2s Brush runtime
… = … Each step = 1 second
0 = 10 s
A = 15 s
B = 20 s
C = 25 s
Each step = 5 seconds
D = 30 s
E = 35 s
F = 40 s

Edited by: FA EN_Universalplatine_3


Technical Information

Page 4 of 7 Universal Control Board III Info-No.


Item no. 130 120 360’-10-00
15/09/2021
2021-P1
(207 - 507 V / 50 - 60 Hz)

1.4 Function # 4 “Fade out time”

Setting Function
1 = 0s
Fade out time
2 = 1s
… = … Each step = 1 second
9 = 9s
A = 10 s
B = 15 s
C = 20 s
Each step = 5 seconds
D = 25 s
E = 30 s
F = 35 s
0 Not used

1.5 Function F „Test operation” of service LED (if available)

Setting Function
1 Test operation of canister empty message:
- when the canister is empty (lance pulled out), the LED lights up yellow

- after 3 seconds pump running time the LED flashes yellow

Test operation of service requirement message:

- after 12 seconds brush running time the LED lights red

- after 18 seconds brush running time the LED flashes red

NOTE
RESET required:
To reset the test mode, the LT1 and LT2 light scanners must be occupied
simultaneously for 3 seconds.

Edited by: FA EN_Universalplatine_3


Technical Information

Page 5 of 7 Universal Control Board III Info-No.


Item no. 130 120 360’-10-00
15/09/2021
2021-P1
(207 - 507 V / 50 - 60 Hz)

2 TROUBLESHOOTING
2.1 Fault analysis on the basis of the 7-segment display
The control board has a 7-segment display.
On the basis of this display, various operating and fault states can be analyzed. In
normal operation, the display shows the current program number. The decimal point
flashes when one or more actuators (outputs switched) are active.
If the segment display flashes, there is a fault, which you can analyze using the
following table.

7-segment display

Display Fault Possible cause Remedy


0 Canister is empty (lance on) Cleaning agent canister is empty Fill the canister
2 Photoelectric sensor 1 Dirt, deadlock, wrong connection, Check LT1,
permanently used … check path LT1 to
(> 60 seconds) terminal

3 Photoelectric sensor 2 Dirt, deadlock, wrong connection, Check LT2,


permanently used … Check path LT2 to
(> 60 seconds) terminal

4 Brushes: Path phase L1 Phase is missing, Check L1, fuse L1 and


fault fuse is defective / missing, alternistor L1
alternistor is defective
5 Brushes: Path phase L2 Phase is missing, Check L2, fuse L2 and
fault fuse is defective / missing, alternistor L2
alternistor is defective

6 Brushes: Path phase L3 Phase is missing, Check L3, fuse L3 and


fault fuse is defective / missing, alternistor L3
alternistor is defective
9 24V out of tolerance Power supply fault Check measuring point 1
(± 10%) for 24V
A Read or write error EEPROM (IC9) cannot be Replace the control
EEPROM addressed
b No pump No pump is connected, circuit Check connection on 16-
(consumer) was detected breaker is defective pin header,
if OK, check BTS716

C No valve No valve is connected, Check connection to 16-


(consumer) was detected circuit breaker is defective pin header,
if OK, check BTS716

Edited by: FA EN_Universalplatine_3


Technical Information

Page 6 of 7 Universal Control Board III Info-No.


Item no. 130 120 360’-10-00
15/09/2021
2021-P1
(207 - 507 V / 50 - 60 Hz)

Display Fault Possible cause Remedy


d No turnstile (consumer) was RX or TX line is interrupted Check the cable,
detected (J1, Pin1 or Pin2) check the plug
E Emergency stop Emergency stop button is actuated Check / unlock the
emergency stop button
P Proximity switch Proximity switch (grate grid) is not Close the grate grid,
closed check the proximity switch
U Fault in the USB USB functionality (USB device is Check the USB slot
functionality not compatible)

2.2 Fault analysis on the basis of the LED displays


The control board contains various LED indicators.

8
1 9
2
3

4 10
6

5 12 11
7

Universal control board III

Edited by: FA EN_Universalplatine_3


Technical Information

Page 7 of 7 Universal Control Board III Info-No.


Item no. 130 120 360’-10-00
15/09/2021
2021-P1
(207 - 507 V / 50 - 60 Hz)

On the basis of the LED indicators, various operating and fault states can be analyzed:

Input LED Input signal and switching state


Emergency stop LD1 yellow on 1 not actuated
off 0 actuated
Light scanner 1 LD2 yellow on 1 actuated
(LT1)
off 0 not actuated
Light scanner 2 LD3 yellow on 1 actuated
(LT2)
off 0 not actuated
Proximity switch LD4 yellow on 1 actuated
off 0 not actuated
Suction lance LD7 yellow on 1 actuated (empty)
off 0 not actuated (not empty)

Output LED Output signal and switching state


Water valve LD5 green on 1 switched on
off 0 switched off
Chemical pump LD6 green on 1 switched on
off 0 switched off
Brushes LD8 green on 1 switched on
off 0 switched off
Potential-free LD9 green on 1 switched on
contact
off 0 switched off

State LED Signal function


Life LD10 blue 10 Hz flashing Self-test when switching on (about 2 s)
1 Hz flashing Normal operation
5 Hz flashing Defective (possibly also other flashing
frequency)
off Defective
5V LD11 green on 5 V present
off 5 V faulty
24 V LD12 green on 24 V present
off 24 V faulty

Edited by: FA EN_Universalplatine_3