5.2 5.

3
5.1
Zone: AGUA AMARGA CORRIENTE 5 Zone: AGUA AMARGA CORRIENTE 5
Zone: AGUA AMARGA CORRIENTE 5
Ø: 6 in Ø: 6 in
Ø: 6 in
Flow: 295 gpm Flow: 295 gpm
Flow: 295 gpm
P in Total: 25.81 psi g P in Total: -0.05688 psi g
P in Total: 32.12 psi g
P out Total: 24.94 psi g P out Total: 0 psi g
P out Total: 31.4 psi g

4 2 7 2

Descarga GA-01 Orifice Meter 1 FB-01


Op: Flow Rate @ 295 gpm Ø: 2.454 in Control Valve 1
Op: P Total @ 0 psi g
Type: Flow in Flow: 295 gpm Op: dP Total @ 25 psi
Flow: 295 gpm
Flow: 295 gpm dP Total: 5.587 psi Flow: 295 gpm
P Total: 0 psi g
P Total: 32.12 psi g P in Total: 31.4 psi g dP Total: 25 psi
P Static: -0.0864 psi g
P Static: 32.04 psi g P out Total: 25.81 psi g P in Total: 24.94 psi g
P Dynamic: 0.0864 psi
P Dynamic: 0.0864 psi Beta: 0.426 P out Total: -0.05688 psi g
Cd: 0.6028 Flow Coefficient: 58.22 Cv
PR: -- Position: 50.44%

PIPE-FLO Advantage Student Edition Units Project Information


Program Version: 18.2 Area: ft² Flow rate: gpm Heat Transfer Rate: BTU/h Company: YM
Calculation Method: Darcy-Weisbach Length: ft Pressure: psi Heat Transfer Coefficient: BTU/h*ft²°F Project: Valvula de control y Placa orificio
Maximum Iterations: 1000 Elevation: ft Power: hp Specific Heat Capacity: BTU/lb°F Drawn by: MSAL
Percent Tolerance: 0.01 % Diameter: in Temperature: °F Thermal Capacitance: BTU/h°F File Name: Valvula control y placa de orificio GA_01.pipe
Laminar Cutoff Re: 2100 Velocity: ft/s Density: lb/ft³ Thermal Insulance: h*ft²°F/BTU Lineup: <Design Case>
Allowable Deviation: 1 % Volume: gal Viscosity: cP Atmospheric Pressure: 14.7 psi a Print Date: miércoles, noviembre 15, 2023 11:29 P. M.