Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

INDUSTRIAL FLOORING

MONNELI EPOFLOOR E250


High Performance Epoxy Floor CoaƟng

Product DescripƟon InstrucƟons for Use

A two component high performance solvent free epoxy Surface Treatment


system consis ng of a colored base resin, hardener. It is
suitable for chemical protec on coverings of industrial Concrete Substrates
pavements and reinforced concrete.
The surface of the concrete to be prepared shall be
EPOFLOOR E250 adheres perfectly to a variety of sound, clean and uncontaminated.
supports like: concrete, wood, stoneware, etc. Once
This prepara on shall be such as to leave a sound exposed
cured, the product transforms to an an -dust, chemical
concrete surface free from dust, loose par cles and any
resistant con nuous membrane. The applied coa ng
deleterious ma er. If the concrete surface is defec ve or
is characterized excellent abrasive resistance and
has laitance, it must be cut back to a sound base. Excess
mechanical strength.
laitance deposits are best removed by light mechanical
scrabbling, grinding or grit/cap ve blas ng followed by
Uses vacuum cleaning to remove dust debris.
Any blowholes, chipping or similar surface imperfec ons
EPOFLOOR E250 is used as a resistant coa ng against shall be repaired using EPOFINISH, a solvent free epoxy
chemicals and as an abrasion protec ve covering for resin repair mortar. Allow the repair material to harden.
floors.
Expansion joints shall be repaired using EPOMORT HS, a
EPOFLOOR E250 is an ideal system for heavy duty floor High strength solvent free epoxy mortar.
coa ng such as:
New concrete or cemen ous surfaces should be allowed
 Car parks to cure and have moisture content not exceeding 5%. Old
 Industrial floors or exis ng floor should be refurbished mechanically to
ensure clear sound substrate.
 Laboratories, loading docks ramps
 Showers Priming
 Aircra hangers Highly porous concrete must be treated with PRIMER
POXY FF, a Solvent-free high performance Epoxy primer.
Advantages In that case the primer should be applied by brush or
roller on to the cleaned surface area (par cularly hidden
 Solvent free and odorless surfaces) at a rate of 5-6 m²/Liter.

 Durable and low maintenance cost The primer should be le to achieve a tack-free condi on
before applying the top coat. A second coat of primer
 Excellent resistance to a wide range of chemicals may be required if the substrate is excessively porous.
 High mechanical strength, with excellent abrasion
resistance Mixing
 Excellent adhesion to the substrate. Bonding EPOFLOOR E250 is supplied in two pre-weighed packs
strength is greater than cohesive strength of (Component A – Base and Component B – Hardener)
concrete which are ready for immediate in-situ use. S r in both
 Less labour cost to achieve the required thickness components before use.
(250 micron per coat)
Transfer the en re contents of component B (Hardener)
into the component A (Base) can and mix with low
Technical Data
speed drill and paddle (200 – 300 rpm) for 2-3 minutes
ll obtaining a mix with uniform consistency. Scrape the
sides and bo om of the can during mixing to ensure ProperƟes Results
homogeneity.
Appearance Liquid coa ng
ApplicaƟon Refer Colmef
Color
Color Chart
Apply two coats of EPOFLOOR E250 with a roller,
squeegee or airless spray to the primed tack free surface Viscosity at 25°C 1500 cps
at a consump on rate of 4-5 m²/Liter.
Density at 25°C 1.61 kg /L
Each coat will be a minimum of 200-250 microns thick.
VOC 20.0 g/L
The second coat shall be applied a er the first coat is
completely dry. Solid content 100 %

The total dry film thickness of the coa ng shall be a Pot-life me at 25°C 60 minutes
minimum of 400-500 microns. Bond strength 2.0 N / mm²
For an -slip flooring, silica sand (with suitable size) (ASTM D 4541) Concrete failure
can be broadcasted on first coat in order to achieve Compressive strength
leathere e like finish. 72 N / mm²
(ASTM C 579)
For heavy traffic areas such as drive lanes, ramps, turn Flexural strength
36 N / mm²
areas, or other areas subjected to high abrasive traffic, (ASTM C 580)
apply a third coat EPOFLOOR E 250. Tensile strength
20 N / mm²
(ASTM C 307)
Cleaning
Abrasion resistance
68 mg, 1000 cycles
Tools and equipment should be cleaned with SOLVENTE (ASTM D 4060)
10 immediately a er use. Hardened material should be
removed mechanically. Water absorp on
0.05%
(BS EN 12390)
Spillages should be absorbed with sand or sawdust and
disposed of in accordance with local regula ons. Cri cal radiant flux
Class I
(ASTM E648)
RecommendaƟons Open to vehicular traffic
48 hours
 EPOFLOOR E250 should not be applied onto at 25°C
surfaces likely to suffer from rising dampness or Open to foot traffic
rela ve humidity > 70% 24 hours
at 25°C
 EPOFLOOR E250 should not be applied at Service temperature -5°C to +80°C
temperature below +5°C
All values are subject to 5-10 % tolerance
 EPOFLOOR E250 should not be applied at asphalt
floors or PVC les
 EPOFLOOR E250 should be applied internally. If used
exteriors it is strongly recommended to cover with
one or two coats of EPOFLOOR UV2
Chemical Resistance Storage

Fully cured EPOFLOOR E250 samples have been tested Keep in ghtly closed containers and in sheltered and
in a wide range of aggressive chemicals commonly found dry place with a temperature between +5°C and +35°C.
in industrial environments. Tests were performed in Shelf life is 12 months from date of produc on if stored
accordance to ASTM D543 standards over 7 days at +25°C. properly.

Material Resistance Health & Safety

Hydrochloric acid (20%) Resistant During applica on, wear appropriate protec ve cloth-
Sulphuric acid (20%) Resistant ing, goggles, gloves and respiratory equipment if neces-
sary. In case of contact with skin, rinse with water and
Sodium hydroxide (50%) Resistant again wash thoroughly with soap and water.
Ammonia (10%) Resistant
In case of contact with eyes, rinse with plenty of water
Petrol Resistant and seek medical advice accordingly.
Oil Resistant
If ingested, obtain medical a en on immediately. Do
Kerosene Resistant not induce vomi ng.
Butanol Resistant
Skydrol Resistant
Industrial methylated
Resistant
spirits
Saturated sugar solu on Resistant
Urea (saturated) Resistant
Bleach (5%) Resistant

ConsumpƟon

4-5 m² / liter according to the porosity of support

Packaging

EPOFLOOR E250 is supplied 4 and 15 Liter Kits

The informa on in this Technical Data Sheet is based on Colmef Monneli’s experience. Colmef Monneli does not accept any liability arising from the use of its products as it
has no direct or con nuous control over where or how its products are applied. All Colmef Monneli’s Data Sheets are updated on regular basis. It is the user’s responsibility to
obtain the latest version.

EPOFLOOR E250