Professional Documents
Culture Documents
Precision 32 CT Product Recommendation, Campo Imaging
Precision 32 CT Product Recommendation, Campo Imaging
Product Recommendation
7. After-sale Services...................................................................... 14
Liaoning Campo Imaging Medical Co., Ltd (Campo Imaging) is an innovator in the
equipment such as CT, DR and so on. The company has the top talents in medical
We have the core R&D team headed by Dr. Yu Zou, as chief scientist, he received a
bachelor degree in nuclear physics from Peking University and a Ph.D. degree from
the Chinese Academy of Sciences. He also did postdoctoral research work in both
scientist and the chief scientist at Toshiba Medical Research Institute USA, Inc.; He has
34 filed patents at the University of Chicago and the Toshiba American Research
Institute, 8 public patents in the U.S. The core of research & development team, led
by chief scientist
The R&D team includes nearly 100 overseas experts and industrial elites, distributed
not only in China's headquarters but also in the U.S. R&D center.
Adhere to the truth, Benefit for the society. Campo Imaging actively promotes
tomography technology, P-Axial, provides the thinnest and finest CT image in the
industry of 0.275mm, which has obvious advantages in the application of inner ear
image and lung nodule. For the first time, dual-energy imaging technology has been
and accurate diagnosis with high-quality image and stable performance, and become
b) Multi-pixel HD algorithm;
c) Dual-energy platform;
3. Characters of Precision 32
Apply to:
labyrinth, ear bones, ligaments and nerves of ear bones all can be seen
measurement
2) Multi-pixel HD algorithm
with 1024x1024m image matrix, the human body and lesion structure could be
The conventional thin-slice CT image shows a GGN in the right lung. The image
3) Dual-energy platform
Precision 32 equipped the maturest sequence tomography technique, that is, the CT
imaging system does not change, but adopts two rotatory scanning imaging, one
rotation with higher kVp (e.g.,140 kVp) and one with lower kVp (e.g.,80 kVp). The
two-domain spatial registration of two-time imaging data in data domain and image
dual-energy.
avoided.
b) Homodomain: The bed is stationary during the X-ray data collection of high
and low kV energy, ensure accurate matching of high and low kV data
technique, to make sure the radiation dose of dual-energy scan lower than normal
scan, while obtain excellent images. In addition, there will be no tube overheating
Case presentation: This patient was a 67-year-old man with many years of bladder
calculi. Image showed two large (1) small (2) stones in the bladder, and the main
components of the stones were determined as uric acid by scatter plot. At the same
time, calculi were found in the water diagram but not in the bone diagram, which was
In order to minimize the radiation dose to patients, Precision 32 includes the low
dose control system such as P-Dose, P-IR and so on, also provides scanning solution
dose of different parts of human body according to the density and shape of different
mode which is the lowest in the industry, reduce the damage of CT radiation to
reduction in the original and image data Fields, enhance image quality
standard, realizes to obtain, process, analyze, manage, archive, query, browse, print,
Virtual endoscope;
Wuhan, Hubei Province, China. COVID-19 is not the same as the coronaviruses that
commonly circulate among humans and cause mild illness, like the common cold.
Fever, cough, and dyspnea were the most common symptoms in patients with
disease.
traditional CT imaging, which can provide 0.275mm precise CT images for detecting
margins and other COVID-19 CT findings. Precision CT will fully facilitate the early and
A B
Figure A: CT image without P-Axial technique Figure B: CT image with P-Axial technique
and diagnosis of the pneumonia, and thinner scanning slices clearer the lesions
showed.
With the patent of 0.275mm ultra-thin precise tomography, the detection rate of
minor lesions can be significantly increased by breaking the limit of the thickness of
common CT images, with 60 kV /70 kV ultra-low energy scanning, which can reduce
1 Gantry 1 Standard
3 Console 1 Standard
6. Product Parameter
5 Min-dose 60kV
7 Tilt ±30°
10 FOV 506mm
7. After-sale Services
We will provide you with a full range of pre-sales and after-sales services.
· Reduce downtime
We can customize the service solution for you: The modular performance solution
ensures that the system has excellent flexibility to meet the specific requirements; we
will also regularly maintain the CT system to optimize availability, so that improve
(3)About installation:
installation process.
(4)About training:
After installation, our senior product training experts provide professional application
training and support to help consumers master the operation application of the new
system.
(5):About maintenance:
Note: This is for reference only, not as a legal offer. The final contract will prevail!